Erschienen in:
19.08.2021 | Original Article
The potential utility of [68 Ga]Ga-DOTA-FAPI-04 as a novel broad-spectrum oncological and non-oncological imaging agent—comparison with [18F]FDG
verfasst von:
Lianjun Lan, Hanxiang Liu, Yingwei Wang, Jia Deng, Dengsai Peng, Yue Feng, Li Wang, Yue Chen, Lin Qiu
Erschienen in:
European Journal of Nuclear Medicine and Molecular Imaging
|
Ausgabe 3/2022
Einloggen, um Zugang zu erhalten
Abstract
Purpose
This study aimed to compare the detection performance of [68 Ga]Ga-DOTA-FAPI-04 and [18F]FDG PET/CT in the patients with various oncological and non-oncological lesions.
Methods
A total of 123 patients underwent contemporaneous [68 Ga]Ga-DOTA-FAPI-04 and [18F]FDG PET/CT were included in this prospective study. The maximum standard uptake value (SUVmax) was measured to compare oncological and non-oncological lesion uptake. The sensitivity, specificity, predictive values, and accuracy of [18F]FDG and [68 Ga]Ga-DOTA-FAPI-04 PET/CT for detecting primary, metastatic, and non-oncological lesions were calculated and compared to evaluate the detection efficacy.
Results
The study subjects consisted of 123 patients (69 men and 54 women; mean age 56.11 ± 11.94 years). Among the 102 patients with either newly diagnosed (82 patients) or previously treated solid tumor (20 patients), a total of 88 solid primary malignant tumors in 84/102 patients were detected. Two patients had two primary tumors each and 1 patient had three primary tumors. Among them, 58/102 and 43/102 patients had nodal (376 lesions) and distant metastases (406 lesions), respectively. Eight patients had hematological neoplasm. No malignant oncological diseases were detected in the remaining 13 patients. A total of 145 non-oncological lesions and benign tumors in 52/123 patients were detected incidentally. [68 Ga]Ga-DOTA-FAPI-04 PET/CT demonstrated a significantly higher uptake and detection rate for the primary (SUVmax 10.98 ± 5.83 vs. 8.36 ± 6.43, p < 0.001; sensitivity 97.67 vs. 84.89%; and accuracy 96.59 vs. 82.95%, X2 = 0.538, p = 0.021), nodal (SUVmax 10.50 ± 5.98 vs. 8.20 ± 6.29, p = 0.011; sensitivity 97.59 vs. 84.72%; and accuracy 97.34 vs. 84.31%, X2 = 2.067, p < 0.001), and distant metastatic lesions (SUVmax 9.64 ± 6.45 vs. 6.74 ± 4.83; p < 0.001; sensitivity 98.01 vs. 65.59%; and accuracy 97.04 vs. 65.51%, X2 = 4.897, p < 0.001) of solid tumor than did [18F]FDG PET/CT. [68 Ga]Ga-DOTA-FAPI-04 PET/CT demonstrated a lower activity (SUVmax: 6.84 ± 4.67 vs. 13.09 ± 7.29, p < 0.001) and detection rate (sensitivity 50.65 vs. 96.75%, and accuracy 51.28 vs. 95.51%, X2 = 5.166, p < 0.001) for multiple myeloma and lymphoma compared to [18F]FDG PET/CT. [68 Ga]Ga-DOTA-FAPI-04 and [18F]FDG PET/CT PET/CT demonstrated a comparative activity (SUVmax 6.40 ± 3.95 vs. 5.74 ± 15.78, p = 0.729) and detection efficacy (sensitivity 86.52 vs. 72.34%, and accuracy 84.83 vs. 72.41%, X2 = 9.460, p = 0.007) for non-oncological lesion and benign tumor detection.
Conclusions
Except for myeloma and lymphoma, [68 Ga]Ga-DOTA-FAPI-04 PET/CT showed a superior detection efficacy for detecting various primary and metastatic lesions than [18F]FDG PET/CT. A comparative detection utility for non-oncological lesion was obtained with both tracers. [68 Ga]Ga-DOTA-FAPI-04 could be used as a broad-spectrum tumor and inflammatory imaging agent in the clinical especially for various solid tumors and non-oncological lesions.