Skip to main content
Erschienen in: Abdominal Radiology 4/2004

01.07.2004 | Invited update

Liver tumors

verfasst von: D. Cosgrove, M. Blomley

Erschienen in: Abdominal Radiology | Ausgabe 4/2004

Einloggen, um Zugang zu erhalten

Abstract

The development and clinical introduction of microbubble contrast agents has had a particular impact on the detection and differential diagnosis of liver tumors. The first approach widely employed made use of high-transmission power ultrasound, which destroyed the microbubbles in the process of imaging them. It is particularly successful for those agents that have a liver-specific post-vascular phase because, like liver-specific agents used in other imaging modalities such as magnetic resonance imaging and nuclear medicine, malignancies do not retain the contrast, so they stand out with very high conspicuity. Used this way with color Doppler or variants of it, more subcentimeter lesions can be demonstrated with ultrasound than with computed tomography. However, the destructive nature of this approach meant that continuous real-time scanning was impossible. Two developments allowed this to be redressed: new classes of microbubbles with perfluoro gasses instead of air and the invention of multipulse scanning modes that are sensitive to the nonlinear (harmonic) responses of the microbubbles and suppresses tissue signals. This low-power approach is now used almost exclusively, and it has the advantage of displaying the arterial phase of blood supply to a mass and a later phase when the bubbles are trapped in the sinusoids so that the vascular volume of the tissue is depicted. Malignancies typically show a low signal intensity in this phase, regardless of whether they are hyper- or hypovascular in terms of their arterial supply. This allows them to be detected with high sensitivity and much more easily than the destructive modes allowed. In addition, the arterial supply that can be now depicted in real time has characteristics that allow most benign masses to be distinguished from each other and from malignancies, thus improving specificity. Microbubbles also can be used as tracers to provide functional information that can detect occult metastases and cirrhosis noninvasively.
Literatur
1.
Zurück zum Zitat Wernecke, K, Rummeney, E, Bongartz, G, et al. 1991Detection of hepatic masses in patients with carcinoma: comparative sensitivities of sonography, CT and MR imaging.AJR157731739PubMed Wernecke, K, Rummeney, E, Bongartz, G,  et al. 1991Detection of hepatic masses in patients with carcinoma: comparative sensitivities of sonography, CT and MR imaging.AJR157731739PubMed
2.
Zurück zum Zitat Blomley, MJ, Cooke, JC, Unger, EC, et al. 2001Microbubble contrast agents: a new era in ultrasound.BMJ32212221225CrossRefPubMed Blomley, MJ, Cooke, JC, Unger, EC,  et al. 2001Microbubble contrast agents: a new era in ultrasound.BMJ32212221225CrossRefPubMed
3.
Zurück zum Zitat de Jong, N, Ten Cate, FJ 1996New ultrasound contrast agents and technological innovations.Ultrasonics34587590CrossRefPubMed de Jong, N, Ten Cate, FJ 1996New ultrasound contrast agents and technological innovations.Ultrasonics34587590CrossRefPubMed
4.
Zurück zum Zitat Uhlendorf, V, Scholle, FD, Reinhardt, M 2000Acoustic behaviour of current ultrasound contrast agents.Ultrasonics388186CrossRefPubMed Uhlendorf, V, Scholle, FD, Reinhardt, M 2000Acoustic behaviour of current ultrasound contrast agents.Ultrasonics388186CrossRefPubMed
5.
Zurück zum Zitat Phillips P. Contrast pulse sequence imaging of non-linear microbubbles. In: Proceedings of the IEE Ultrasonics Symposium. 2001:1739–1745 Phillips P. Contrast pulse sequence imaging of non-linear microbubbles. In: Proceedings of the IEE Ultrasonics Symposium. 2001:1739–1745
6.
Zurück zum Zitat Wei, K, Jayaweera, A, Firoozan, S 2001Quantification of myocardial blood flow with ultrasound induced destruction of microbubbles administered as a constant venous infusion.Circulation97473483 Wei, K, Jayaweera, A, Firoozan, S 2001Quantification of myocardial blood flow with ultrasound induced destruction of microbubbles administered as a constant venous infusion.Circulation97473483
7.
Zurück zum Zitat Strobel, D, Krodel, U, Martus, P, et al. 2000Clinical evaluation of contrast-enhanced color Doppler sonography in the differential diagnosis of liver tumors.J Clin Ultrasound28113CrossRefPubMed Strobel, D, Krodel, U, Martus, P,  et al. 2000Clinical evaluation of contrast-enhanced color Doppler sonography in the differential diagnosis of liver tumors.J Clin Ultrasound28113CrossRefPubMed
8.
Zurück zum Zitat Blomley, M, Albrecht, T, Cosgrove, D, et al. 1998Stimulated acoustic emission in liver parenchyma with Levovist.Lancet351568 Blomley, M, Albrecht, T, Cosgrove, D,  et al. 1998Stimulated acoustic emission in liver parenchyma with Levovist.Lancet351568
9.
Zurück zum Zitat Blomley, MJ, Albrecht, T, Cosgrove, DO, et al. 1999Improved imaging of liver metastases with stimulated acoustic emission in the late phase of enhancement with the US contrast agent SH U 508A: early experience.Radiology210409416PubMed Blomley, MJ, Albrecht, T, Cosgrove, DO,  et al. 1999Improved imaging of liver metastases with stimulated acoustic emission in the late phase of enhancement with the US contrast agent SH U 508A: early experience.Radiology210409416PubMed
11.
Zurück zum Zitat Albrecht, T, Blomley, MJ, Burns, PN, et al. 2003Improved detection of hepatic metastases with pulse-inversion US during the liver-specific phase of SHU 508A: multicenter study.Radiology227361370PubMed Albrecht, T, Blomley, MJ, Burns, PN,  et al. 2003Improved detection of hepatic metastases with pulse-inversion US during the liver-specific phase of SHU 508A: multicenter study.Radiology227361370PubMed
12.
Zurück zum Zitat Uggowitzer, MM, Kugler, C, Mischinger, HJ, et al. 1999Echo-enhanced Doppler sonography of focal nodular hyperplasia of the liver.J Ultrasound Med18445451PubMed Uggowitzer, MM, Kugler, C, Mischinger, HJ,  et al. 1999Echo-enhanced Doppler sonography of focal nodular hyperplasia of the liver.J Ultrasound Med18445451PubMed
13.
Zurück zum Zitat Uggowitzer, M, Kugler, C, Stacher, R, et al. 1999New sonographic approaches to the evaluation of FNH.Ultrasound Med Biol2325 Uggowitzer, M, Kugler, C, Stacher, R,  et al. 1999New sonographic approaches to the evaluation of FNH.Ultrasound Med Biol2325
14.
Zurück zum Zitat Kim, JH, Kim, TK, Kim, BS, et al. 2002Enhancement of hepatic hemangiomas with Levovist on coded harmonic angiographic ultrasonography.J Ultrasound Med21141148PubMed Kim, JH, Kim, TK, Kim, BS,  et al. 2002Enhancement of hepatic hemangiomas with Levovist on coded harmonic angiographic ultrasonography.J Ultrasound Med21141148PubMed
15.
Zurück zum Zitat Wilson, SR, Burns, PN 2001Liver mass evaluation with ultrasound: the impact of microbubble contrast agents and pulse inversion imaging.Semin Liver Dis21147159CrossRefPubMed Wilson, SR, Burns, PN 2001Liver mass evaluation with ultrasound: the impact of microbubble contrast agents and pulse inversion imaging.Semin Liver Dis21147159CrossRefPubMed
16.
Zurück zum Zitat Meuwly, J-Y, Schnyder, P, Gudinchet, F, Denys, A 2003Pulse-inversion harmonic imaging improves lesion conspicuity during US-guided biopsy.J Vasc Interv Radiol14335341PubMed Meuwly, J-Y, Schnyder, P, Gudinchet, F, Denys, A 2003Pulse-inversion harmonic imaging improves lesion conspicuity during US-guided biopsy.J Vasc Interv Radiol14335341PubMed
17.
Zurück zum Zitat Raisinghani, A, DeMaria, A 2002Physical principles of microbubble ultrasound contrast agents.Am J Cardiol903J7JCrossRefPubMed Raisinghani, A, DeMaria, A 2002Physical principles of microbubble ultrasound contrast agents.Am J Cardiol903J7JCrossRefPubMed
18.
Zurück zum Zitat Hope-Simpson D, Chin C, Burns P. Pulse inversion Doppler: a new method for detecting non-linear echoes from microbubble contrast agent. In: IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control. 1999 Hope-Simpson D, Chin C, Burns P. Pulse inversion Doppler: a new method for detecting non-linear echoes from microbubble contrast agent. In: IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control. 1999
19.
Zurück zum Zitat Aube, C, Lebigiot, J 1999Ultrasound with microbubble contrast agents: diagnosis and characterisation of hepatic tumors.Gastroenterol Clin Biol276370 Aube, C, Lebigiot, J 1999Ultrasound with microbubble contrast agents: diagnosis and characterisation of hepatic tumors.Gastroenterol Clin Biol276370
20.
Zurück zum Zitat Hohmann, J, Albrecht, T, Hoffmann, C, Wolf, K 2003Ultrasonographic detection of focal liver lesions: increased sensitivity and specificity with microbubble contrast agents.Eur J Radiol46147159CrossRefPubMed Hohmann, J, Albrecht, T, Hoffmann, C, Wolf, K 2003Ultrasonographic detection of focal liver lesions: increased sensitivity and specificity with microbubble contrast agents.Eur J Radiol46147159CrossRefPubMed
21.
Zurück zum Zitat Solbiati, L, Cova, L, Ierace, L 2003Specificity of contrast-enhanced harmonic sonography for characterization of solid, incidentally detected focal liver lesions.Ultrasound Med Biol29S23CrossRef Solbiati, L, Cova, L, Ierace, L 2003Specificity of contrast-enhanced harmonic sonography for characterization of solid, incidentally detected focal liver lesions.Ultrasound Med Biol29S23CrossRef
22.
Zurück zum Zitat Leen, E, Becker, D, Bolondi, L, et al. 2003Prospective, open-label, multi-centre study evaluating the accuracy of unenhanced versus SonoVue® enhanced ultrasonography (US) in the characterisation of focal liver lesions.Ultrasound Med Biol29S23CrossRef Leen, E, Becker, D, Bolondi, L,  et al. 2003Prospective, open-label, multi-centre study evaluating the accuracy of unenhanced versus SonoVue® enhanced ultrasonography (US) in the characterisation of focal liver lesions.Ultrasound Med Biol29S23CrossRef
23.
Zurück zum Zitat Solbiati, L, Goldberg, S, Ierace, T, et al. 1999Radio-frequency ablation of hepatic metastases: postprocedural assessment with a US microbubble contrast agent.Radiology211643649PubMed Solbiati, L, Goldberg, S, Ierace, T,  et al. 1999Radio-frequency ablation of hepatic metastases: postprocedural assessment with a US microbubble contrast agent.Radiology211643649PubMed
24.
Zurück zum Zitat Numata, K, Isozaki, T, Ozawa, Y, Tanaka, K 2003Percutaneous ablation therapy guided by contrast-enhanced sonography for patients with hepatocellular carcinoma.AJR180143149PubMed Numata, K, Isozaki, T, Ozawa, Y, Tanaka, K 2003Percutaneous ablation therapy guided by contrast-enhanced sonography for patients with hepatocellular carcinoma.AJR180143149PubMed
25.
Zurück zum Zitat Blomley, MJ, Albrecht, T, Cosgrove, DO, Bamber, JC 1997Can relative contrast agent concentration be measured in vivo with color Doppler US?Radiology204279281 Blomley, MJ, Albrecht, T, Cosgrove, DO, Bamber, JC 1997Can relative contrast agent concentration be measured in vivo with color Doppler US?Radiology204279281
26.
Zurück zum Zitat Harvey, C, et al. 2001Can liver micrometastases be detected by hepatic vein transit times in colo-rectal cancer?Radiology.. Harvey, C,  et al. 2001Can liver micrometastases be detected by hepatic vein transit times in colo-rectal cancer?Radiology..
27.
Zurück zum Zitat Albrecht, T, Blomley, MJ, Cosgrove, DO, et al. 1999Non-invasive diagnosis of hepatic cirrhosis by transit-time analysis of an ultrasound contrast agent.Lancet35315791583CrossRefPubMed Albrecht, T, Blomley, MJ, Cosgrove, DO,  et al. 1999Non-invasive diagnosis of hepatic cirrhosis by transit-time analysis of an ultrasound contrast agent.Lancet35315791583CrossRefPubMed
28.
Zurück zum Zitat Blomley, M, Lim, A, Harvey, C, et al. 2003Liver microbubble transit time compared with histology and Child-Pugh score in diffuse liver disease.Gut5211881193CrossRefPubMed Blomley, M, Lim, A, Harvey, C,  et al. 2003Liver microbubble transit time compared with histology and Child-Pugh score in diffuse liver disease.Gut5211881193CrossRefPubMed
29.
Zurück zum Zitat Maruyama, H, Matsutani, S, Sato, G, et al. 2000Enhanced color flow images in small hepatocellular carcinoma.Abdom Imaging25164171CrossRefPubMed Maruyama, H, Matsutani, S, Sato, G,  et al. 2000Enhanced color flow images in small hepatocellular carcinoma.Abdom Imaging25164171CrossRefPubMed
30.
Zurück zum Zitat Eckersley R, Cosgrove D, Blomley M, Hashimoto H (1988) Functional imaging of tissue response to bolus injection of ultrasound contrast agent. In: Proceedings of the IEEE Ultrasonics Symposium, Piscataway, NJ. 2:1779–1782 Eckersley R, Cosgrove D, Blomley M, Hashimoto H (1988) Functional imaging of tissue response to bolus injection of ultrasound contrast agent. In: Proceedings of the IEEE Ultrasonics Symposium, Piscataway, NJ. 2:1779–1782
Metadaten
Titel
Liver tumors
verfasst von
D. Cosgrove
M. Blomley
Publikationsdatum
01.07.2004
Erschienen in
Abdominal Radiology / Ausgabe 4/2004
Print ISSN: 2366-004X
Elektronische ISSN: 2366-0058
DOI
https://doi.org/10.1007/s00261-003-0126-7

Weitere Artikel der Ausgabe 4/2004

Abdominal Radiology 4/2004 Zur Ausgabe

Update Radiologie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.