Skip to main content
Erschienen in: Abdominal Radiology 1/2010

01.02.2010

Endoleaks after endovascular repair of abdominal aortic aneurysm: value of CEUS

verfasst von: R. Iezzi, A. R. Cotroneo, R. Basilico, A. Simeone, M. L. Storto, L. Bonomo

Erschienen in: Abdominal Radiology | Ausgabe 1/2010

Einloggen, um Zugang zu erhalten

Abstract

Endovascular repair (EVAR) is playing an increasingly role in the treatment of abdominal aortic aneurysm. A successful procedure depends on the complete sealing of the aneurysm sac from blood flow to achieve general pressure relief and avoid aneurysm rupture, with a shrinkage of the aneurysm sac. The most common complication of EVAR is endoleak that is the persistence of perigraft flow within the aneurysm sac, which has to be considered the major cause of enlargement and rupture of the aneurysm, and the main indication for surgical late conversion. For this reason, strict surveillance of these patients is mandatory for the early detection of endoleaks and the preferred method of follow-up is represented by CT angiography. However, CTA has limitations. The investigation is repeated several times, making radiation exposure a necessary concern. Therefore, it would be useful to have another reliable diagnostic examination during follow-up. Color duplex ultrasound is non-invasive, does not use radiation or contrast medium, is less expensive, easy to perform and widely available. However, this technique obtained poor results in terms of sensitivity in the detection of endoleaks. In the last years, the introduction of ultrasound contrast agents and contrast-specific imaging has, however, rekindled interest in this modality and its potential for replacing of CTA in routine surveillance. The purpose of this review is to highlight the diagnostic value of CEUS in the post-EVAR endoleaks detection.
Literatur
1.
Zurück zum Zitat Bush RL, Lumsden AB, Dodson TF, et al. Mid-term results after endovascular repair of abdominal aortic aneurysm. J Vasc Surg 2001;33(2 Suppl):S70-76.CrossRefPubMed Bush RL, Lumsden AB, Dodson TF, et al. Mid-term results after endovascular repair of abdominal aortic aneurysm. J Vasc Surg 2001;33(2 Suppl):S70-76.CrossRefPubMed
2.
Zurück zum Zitat May J, White GH, Waugh R, et al. Comparison of first- and second-generation prostheses for endoluminal repair of abdominal aortic aneurysms: a 6-year study with life table analysis. J Vasc Surg 2000;32:124-129.CrossRefPubMed May J, White GH, Waugh R, et al. Comparison of first- and second-generation prostheses for endoluminal repair of abdominal aortic aneurysms: a 6-year study with life table analysis. J Vasc Surg 2000;32:124-129.CrossRefPubMed
3.
Zurück zum Zitat Zarins CK, White RA, Hodgson KJ, Schwarten D, Fogarty TJ. Endoleak as a predictor of outcome after endovascular aneurysm repair: AneuRx multicenter clinical trial. J Vasc Surg 2000;32:90-107.CrossRefPubMed Zarins CK, White RA, Hodgson KJ, Schwarten D, Fogarty TJ. Endoleak as a predictor of outcome after endovascular aneurysm repair: AneuRx multicenter clinical trial. J Vasc Surg 2000;32:90-107.CrossRefPubMed
4.
Zurück zum Zitat Cuypers P, Buth J, Harris PL, Gevers E, Lahey R. Realistic expectations for patients with stent-graft treatment of abdominal aortic aneurysms. Results of a European multicentre registry. Eur J Vasc Endovasc Surg 1999; 17: 507–516.CrossRefPubMed Cuypers P, Buth J, Harris PL, Gevers E, Lahey R. Realistic expectations for patients with stent-graft treatment of abdominal aortic aneurysms. Results of a European multicentre registry. Eur J Vasc Endovasc Surg 1999; 17: 507–516.CrossRefPubMed
5.
Zurück zum Zitat Gilling-Smith G, Brennan J, Harris P, et al. Endotension after endovascular aneurysm repair: definition, classification, and strategies for surveillance and intervention. J Endovasc Surg 1999; 6: 305–307.CrossRefPubMed Gilling-Smith G, Brennan J, Harris P, et al. Endotension after endovascular aneurysm repair: definition, classification, and strategies for surveillance and intervention. J Endovasc Surg 1999; 6: 305–307.CrossRefPubMed
6.
Zurück zum Zitat Golzarian J, Struyven J, Abada HT et al. Endovascular aortic stent-grafts: transcatheter embolization of persistent perigraft leaks. Radiology 1997; 202: 731–734.PubMed Golzarian J, Struyven J, Abada HT et al. Endovascular aortic stent-grafts: transcatheter embolization of persistent perigraft leaks. Radiology 1997; 202: 731–734.PubMed
7.
Zurück zum Zitat Gorich J, Rilinger N, Sokiranski R et al. Leakages after endovascular repair of aortic aneurysms: classification based on findings at CT, angiography, and radiography. Radiology 1999; 213: 767–772.PubMed Gorich J, Rilinger N, Sokiranski R et al. Leakages after endovascular repair of aortic aneurysms: classification based on findings at CT, angiography, and radiography. Radiology 1999; 213: 767–772.PubMed
8.
Zurück zum Zitat Lumsden AB, Allen RC, Chaikof EL, et al. Delayed rupture of aortic aneurysms following endovascular stent grafting. Am J Surg 1995; 170: 174–178.CrossRefPubMed Lumsden AB, Allen RC, Chaikof EL, et al. Delayed rupture of aortic aneurysms following endovascular stent grafting. Am J Surg 1995; 170: 174–178.CrossRefPubMed
9.
Zurück zum Zitat Vallabhaneni SR, Harris PL. Lessons learnt from the EUROSTAR registry on endovascular repair of abdominal aneurysm repair. Eur J Radiol 2001; 39: 34–41.CrossRefPubMed Vallabhaneni SR, Harris PL. Lessons learnt from the EUROSTAR registry on endovascular repair of abdominal aneurysm repair. Eur J Radiol 2001; 39: 34–41.CrossRefPubMed
10.
Zurück zum Zitat Bown M.J. Fishwick G, et al. (2004) The postoperative complications of endovascular aortic aneurysm repair. J Cardiovascular Surg 45:335-47. Bown M.J. Fishwick G, et al. (2004) The postoperative complications of endovascular aortic aneurysm repair. J Cardiovascular Surg 45:335-47.
11.
Zurück zum Zitat Golzarian J, Dussaussois L, Abada HT, et al. Helical CT of aorta after endoluminal stent-graft therapy: value of biphasic acquisition. AJR Am J Roentgenol 1998;171:329-331.PubMed Golzarian J, Dussaussois L, Abada HT, et al. Helical CT of aorta after endoluminal stent-graft therapy: value of biphasic acquisition. AJR Am J Roentgenol 1998;171:329-331.PubMed
12.
Zurück zum Zitat Brenner DJ, Hall EJ. Computer Tomography – An increasing Source of Radiation Exposure. N Engl J Med 2007; 357(22): 2277-84.CrossRefPubMed Brenner DJ, Hall EJ. Computer Tomography – An increasing Source of Radiation Exposure. N Engl J Med 2007; 357(22): 2277-84.CrossRefPubMed
13.
Zurück zum Zitat Raman KG, Missig-Carrol N, Richardson T, Muluk SC, Makaroun MS. Color-flow duplex ultrasound versus computed tomographic scan in the surveillance of endovascular aneurysm repair. J Vasc Surg 2003;38:645-51.CrossRefPubMed Raman KG, Missig-Carrol N, Richardson T, Muluk SC, Makaroun MS. Color-flow duplex ultrasound versus computed tomographic scan in the surveillance of endovascular aneurysm repair. J Vasc Surg 2003;38:645-51.CrossRefPubMed
14.
Zurück zum Zitat Sato DT, Goff CD, Gregory RT, et al. Endoleak after aortic stent graft repair: diagnosis by color duplex ultrasound scan versus computed tomography scan. J Vasc Surg 1998;28:657-663.CrossRefPubMed Sato DT, Goff CD, Gregory RT, et al. Endoleak after aortic stent graft repair: diagnosis by color duplex ultrasound scan versus computed tomography scan. J Vasc Surg 1998;28:657-663.CrossRefPubMed
15.
Zurück zum Zitat Henao EA, Hodge MD, Felkai DD, et al. Contrast-enhanced duplex surveillance after endovascular abdominal aortic aneurysm repair: improved efficacy using a continuous infusion technique. J Vasc Surg 2006;43:259-264.CrossRefPubMed Henao EA, Hodge MD, Felkai DD, et al. Contrast-enhanced duplex surveillance after endovascular abdominal aortic aneurysm repair: improved efficacy using a continuous infusion technique. J Vasc Surg 2006;43:259-264.CrossRefPubMed
16.
Zurück zum Zitat Bargellini I, Napoli V, Petruzzi P, et al. Type II lumbar endoleaks: hemodynamic differentiation by contrast-enhanced ultrasound scanning and influence on aneurysm enlargement after endovascular aneurysm repair. J Vasc Surg 2005;41:10-18.CrossRefPubMed Bargellini I, Napoli V, Petruzzi P, et al. Type II lumbar endoleaks: hemodynamic differentiation by contrast-enhanced ultrasound scanning and influence on aneurysm enlargement after endovascular aneurysm repair. J Vasc Surg 2005;41:10-18.CrossRefPubMed
17.
Zurück zum Zitat Napoli V, Bargellini I, Sardella SG, et al. Abdominal aortic aneurysm: contrast-enhanced US for missed endoleaks after endoluminal repair. Radiology 2004;233:217-225.CrossRefPubMed Napoli V, Bargellini I, Sardella SG, et al. Abdominal aortic aneurysm: contrast-enhanced US for missed endoleaks after endoluminal repair. Radiology 2004;233:217-225.CrossRefPubMed
18.
Zurück zum Zitat Giannoni MF, Palombo G, Sbarigia E, et al. Contrast-enhanced ultrasound imaging for aortic stent-graft surveillance. J Endovasc Ther 2003;10:208-217.CrossRefPubMed Giannoni MF, Palombo G, Sbarigia E, et al. Contrast-enhanced ultrasound imaging for aortic stent-graft surveillance. J Endovasc Ther 2003;10:208-217.CrossRefPubMed
19.
Zurück zum Zitat Bendick PJ, Bove PG, Long GW, et al. Efficacy of ultrasound scan contrast agents in the noninvasive follow-up of aortic stent grafts. J Vasc Surg 2003;37(2):381-385.CrossRefPubMed Bendick PJ, Bove PG, Long GW, et al. Efficacy of ultrasound scan contrast agents in the noninvasive follow-up of aortic stent grafts. J Vasc Surg 2003;37(2):381-385.CrossRefPubMed
20.
Zurück zum Zitat Wei K, Skyba DM, Firschke C, et al. Interactions between microbubbles and ultrasound: in vitro and in vivo observations. J Am Coll Cardiol.1997; 29(5):1081-8.CrossRefPubMed Wei K, Skyba DM, Firschke C, et al. Interactions between microbubbles and ultrasound: in vitro and in vivo observations. J Am Coll Cardiol.1997; 29(5):1081-8.CrossRefPubMed
21.
Zurück zum Zitat McWilliams RG, Martin JM, White D, et al. Detection of endoleak with enhanced ultrasound imaging: comparison with biphasic computed tomography. J Endovasc Ther 2002;9:170-179.CrossRefPubMed McWilliams RG, Martin JM, White D, et al. Detection of endoleak with enhanced ultrasound imaging: comparison with biphasic computed tomography. J Endovasc Ther 2002;9:170-179.CrossRefPubMed
22.
Zurück zum Zitat McWilliams RG, Martin JM, White D, et al. Use of contrast-enhanced ultrasound in follow-up after endovascular aortic aneurysm repair. J Vasc Interv Radiol 1999;10:1107-1114.CrossRefPubMed McWilliams RG, Martin JM, White D, et al. Use of contrast-enhanced ultrasound in follow-up after endovascular aortic aneurysm repair. J Vasc Interv Radiol 1999;10:1107-1114.CrossRefPubMed
23.
Zurück zum Zitat Greis C. Technology overview: SonoVue (Bracco, Milan). Eur Radiol Suppl (2004) 14[suppl 8]:P11–P15. Greis C. Technology overview: SonoVue (Bracco, Milan). Eur Radiol Suppl (2004) 14[suppl 8]:P11–P15.
24.
Zurück zum Zitat Brannigan M, Burns PN, Wilson SR. Blood flow patterns in focal liver lesions at microbubble-enhanced US. Radiographics. 2004;24(4):921–935.CrossRefPubMed Brannigan M, Burns PN, Wilson SR. Blood flow patterns in focal liver lesions at microbubble-enhanced US. Radiographics. 2004;24(4):921–935.CrossRefPubMed
25.
Zurück zum Zitat Dill-Macky MJ, Burns PN, Khalili K, et al. Focal hepatic masses: enhancement patterns with SHU 508A and pulse-inversion US. Radiology 2002;222:95–102.CrossRefPubMed Dill-Macky MJ, Burns PN, Khalili K, et al. Focal hepatic masses: enhancement patterns with SHU 508A and pulse-inversion US. Radiology 2002;222:95–102.CrossRefPubMed
26.
Zurück zum Zitat Wilson SR, Burns PN. Liver mass evaluation with ultrasound: the impact of microbubble contrast agents and pulse inversion imaging. Semin Liver Dis. 2001;21(2):147–159.CrossRefPubMed Wilson SR, Burns PN. Liver mass evaluation with ultrasound: the impact of microbubble contrast agents and pulse inversion imaging. Semin Liver Dis. 2001;21(2):147–159.CrossRefPubMed
27.
Zurück zum Zitat Iezzi R, Basilico R, Giancristofaro D, et al. Contrast-enhanced ultrasound versus color duplex ultrasound imaging in the follow-up of patients after endovascular abdominal aortic aneurysm repair. J Vasc Surg. 2009;49(3):552-60.CrossRefPubMed Iezzi R, Basilico R, Giancristofaro D, et al. Contrast-enhanced ultrasound versus color duplex ultrasound imaging in the follow-up of patients after endovascular abdominal aortic aneurysm repair. J Vasc Surg. 2009;49(3):552-60.CrossRefPubMed
28.
Zurück zum Zitat Dill-Macky MJ, Wilson SR, Sternbach Y, Kachura J, Lindsay T. Detecting endoleaks in aortic endografts using contrast-enhanced sonography. AJR Am J Roentgenol. 2007;188(3):W262-8.CrossRefPubMed Dill-Macky MJ, Wilson SR, Sternbach Y, Kachura J, Lindsay T. Detecting endoleaks in aortic endografts using contrast-enhanced sonography. AJR Am J Roentgenol. 2007;188(3):W262-8.CrossRefPubMed
29.
Zurück zum Zitat Giannoni MF, Fanelli F, Citone M, et al. Contrast ultrasound imaging: the best method to detect type II endoleak during endovascular aneurysm repair follow-up. Interact Cardiovasc Thorac Surg 2007;6:359-362.CrossRefPubMed Giannoni MF, Fanelli F, Citone M, et al. Contrast ultrasound imaging: the best method to detect type II endoleak during endovascular aneurysm repair follow-up. Interact Cardiovasc Thorac Surg 2007;6:359-362.CrossRefPubMed
30.
Zurück zum Zitat Carrafiello G, Laganà D, Recaldini C, et al. Comparison of contrast-enhanced ultrasound and computed tomography in classifying endoleaks after endovascular treatment of abdominal aorta aneurysms: preliminary experience. Cardiovasc Intervent Radiol 2006;29:969-974.CrossRefPubMed Carrafiello G, Laganà D, Recaldini C, et al. Comparison of contrast-enhanced ultrasound and computed tomography in classifying endoleaks after endovascular treatment of abdominal aorta aneurysms: preliminary experience. Cardiovasc Intervent Radiol 2006;29:969-974.CrossRefPubMed
31.
Zurück zum Zitat White GH, Yu W, May J, Chaufour X, Stephen MS. Endoleak as a complication of endoluminal grafting of abdominal aortic aneurysms: classification, incidence, diagnosis, and management. J Endovasc Surg 1997;4:152-168.CrossRefPubMed White GH, Yu W, May J, Chaufour X, Stephen MS. Endoleak as a complication of endoluminal grafting of abdominal aortic aneurysms: classification, incidence, diagnosis, and management. J Endovasc Surg 1997;4:152-168.CrossRefPubMed
32.
Zurück zum Zitat White GH, May J, Waugh RC, Chaufour X, Yu W. Type III and type IV endoleak: toward a complete definition of blood flow in the sac after endoluminal AAA repair. J Endovasc Surg 1998;5:305-309.CrossRefPubMed White GH, May J, Waugh RC, Chaufour X, Yu W. Type III and type IV endoleak: toward a complete definition of blood flow in the sac after endoluminal AAA repair. J Endovasc Surg 1998;5:305-309.CrossRefPubMed
33.
Zurück zum Zitat White GH, May J, Petrasek P, et al. Endotension: an explanation for continued AAA growth after successful endoluminal repair. J Endovasc Surg 1999;6:308-315.CrossRefPubMed White GH, May J, Petrasek P, et al. Endotension: an explanation for continued AAA growth after successful endoluminal repair. J Endovasc Surg 1999;6:308-315.CrossRefPubMed
Metadaten
Titel
Endoleaks after endovascular repair of abdominal aortic aneurysm: value of CEUS
verfasst von
R. Iezzi
A. R. Cotroneo
R. Basilico
A. Simeone
M. L. Storto
L. Bonomo
Publikationsdatum
01.02.2010
Verlag
Springer-Verlag
Erschienen in
Abdominal Radiology / Ausgabe 1/2010
Print ISSN: 2366-004X
Elektronische ISSN: 2366-0058
DOI
https://doi.org/10.1007/s00261-009-9526-7

Weitere Artikel der Ausgabe 1/2010

Abdominal Radiology 1/2010 Zur Ausgabe

Update Radiologie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.