Skip to main content
Erschienen in: International Orthopaedics 4/2005

01.08.2005 | Original Paper

Periprosthetic fractures around cementless hydroxyapatite-coated femoral stems

Erschienen in: International Orthopaedics | Ausgabe 4/2005

Einloggen, um Zugang zu erhalten

Abstract

We studied 14 periprosthetic femoral fractures out of a series of 619 hydroxyapatite coated hip implants and compared the outcome to published treatment algorithms using the Vancouver classification. There were five type A fractures, six B1, two B2, and one type B3 fracture. All but one type A fractures were treated conservatively. Compared with the Vancouver classification, we observed a different fracture type in the type B fractures. No fractures at the tip of the stem were seen, as in cemented implants. Three B1 fractures were treated operatively due to fracture displacement, and three were treated conservatively. The B2 and B3 fractures were managed with long, uncemented, revision stems because of a disrupted bone–prosthesis interface. All fractures healed well. This study confirms that the modified algorithm of management of periprosthetic fractures, using the Vancouver classification, is a simple, reproducible, classification system for uncemented prostheses. Conservative treatment is a valid option if the implant is stable whilst surgical intervention is mandatory if the implant is loose.
Literatur
1.
Zurück zum Zitat Beals RK, Tower SS (1996) Periprosthetic fractures of the femur. An analysis of 93 fractures. Clin Orthop 327:238–246 Beals RK, Tower SS (1996) Periprosthetic fractures of the femur. An analysis of 93 fractures. Clin Orthop 327:238–246
2.
Zurück zum Zitat Berry DJ (1999) Epidemiology: hip and knee. Orthop Clin North Am 30:183–190PubMed Berry DJ (1999) Epidemiology: hip and knee. Orthop Clin North Am 30:183–190PubMed
3.
Zurück zum Zitat Brady OH, Garbuz DS, Masri BA, Duncan CP (1999) The treatment of periprosthetic fractures of the femur using cortical onlay allograft struts. Orthop Clin North Am 30:249–257PubMed Brady OH, Garbuz DS, Masri BA, Duncan CP (1999) The treatment of periprosthetic fractures of the femur using cortical onlay allograft struts. Orthop Clin North Am 30:249–257PubMed
4.
Zurück zum Zitat Cooke PH, Newman JH (1982) Fractures of the femur in relation to cemented hip prostheses. J Bone Joint Surg Br 70:368–369 Cooke PH, Newman JH (1982) Fractures of the femur in relation to cemented hip prostheses. J Bone Joint Surg Br 70:368–369
5.
Zurück zum Zitat Duncan CP, Masri BA (1995) Fractures of the femur after hip replacement. Instr Course Lect 44:293–304PubMed Duncan CP, Masri BA (1995) Fractures of the femur after hip replacement. Instr Course Lect 44:293–304PubMed
6.
Zurück zum Zitat Duwelius PJ, Schmidt AH, Kyle RF, Talbott V, Ellis TJ, Butler JB (2004) A prospective, modernized treatment protocol for periprosthetic femur fractures. Orthop Clin North Am 35:485–492PubMed Duwelius PJ, Schmidt AH, Kyle RF, Talbott V, Ellis TJ, Butler JB (2004) A prospective, modernized treatment protocol for periprosthetic femur fractures. Orthop Clin North Am 35:485–492PubMed
7.
Zurück zum Zitat Gill TJ, Sledge JB, Orler R, Ganz R (1999) Lateral insufficiency fractures of the femur caused by osteopenia and varus angulation: a complication of total hip arthroplasty. J Arthroplasty 14:982–987CrossRefPubMed Gill TJ, Sledge JB, Orler R, Ganz R (1999) Lateral insufficiency fractures of the femur caused by osteopenia and varus angulation: a complication of total hip arthroplasty. J Arthroplasty 14:982–987CrossRefPubMed
8.
Zurück zum Zitat Heekin RD, Engh CA, Herzwurm PJ (1996) Fractures through cystic lesions of the greater trochanter. A cause of late pain after cementless total hip arthroplasty. J Arthroplasty 11:757–760CrossRefPubMed Heekin RD, Engh CA, Herzwurm PJ (1996) Fractures through cystic lesions of the greater trochanter. A cause of late pain after cementless total hip arthroplasty. J Arthroplasty 11:757–760CrossRefPubMed
9.
Zurück zum Zitat Johansson JE, McBroom R, Barrington TW, Hunter GA (1981) Fractures of the ipsilateral femur in patients with total hip replacement. J Bone Joint Surg Am 63:1435–1442PubMed Johansson JE, McBroom R, Barrington TW, Hunter GA (1981) Fractures of the ipsilateral femur in patients with total hip replacement. J Bone Joint Surg Am 63:1435–1442PubMed
10.
Zurück zum Zitat Learmonth ID (2004) The management of periprosthetic fractures around the femoral stem J Bone Joint Surg Br 86:13–19PubMed Learmonth ID (2004) The management of periprosthetic fractures around the femoral stem J Bone Joint Surg Br 86:13–19PubMed
11.
Zurück zum Zitat Lotke PA, Wong RY, Ecker ML (1986) Stress fracture as a cause of chronic pain following revision total hip arthroplasty. Report of two cases. Clin Orthop 206:147–150PubMed Lotke PA, Wong RY, Ecker ML (1986) Stress fracture as a cause of chronic pain following revision total hip arthroplasty. Report of two cases. Clin Orthop 206:147–150PubMed
12.
Zurück zum Zitat Masri BA, Meek RM, Duncan CP (2004) Periprosthetic fractures evaluation and treatment. Clin Orthop 420:80–95 Masri BA, Meek RM, Duncan CP (2004) Periprosthetic fractures evaluation and treatment. Clin Orthop 420:80–95
13.
Zurück zum Zitat Mont MA, Maar DC (1994) Fractures of the ipsilateral femur after hip arthroplasty. A statistical analysis of outcome based on 487 patients. J Arthroplasty 9:511–519CrossRefPubMed Mont MA, Maar DC (1994) Fractures of the ipsilateral femur after hip arthroplasty. A statistical analysis of outcome based on 487 patients. J Arthroplasty 9:511–519CrossRefPubMed
14.
Zurück zum Zitat Oosterbos CJ, Rahmy AI, Tonino AJ, Witpeerd W (2004) High survival rate of hydroxyapatite-coated hip prostheses: 100 consecutive hips followed for 10 years. Acta Orthop Scand 75:127–133CrossRefPubMed Oosterbos CJ, Rahmy AI, Tonino AJ, Witpeerd W (2004) High survival rate of hydroxyapatite-coated hip prostheses: 100 consecutive hips followed for 10 years. Acta Orthop Scand 75:127–133CrossRefPubMed
15.
Zurück zum Zitat Rahmy AI, Gosens T, Blake GM, Tonino A, Fogelman I (2004) Periprosthetic bone remodelling of two types of uncemented femoral implant with proximal hydroxyapatite coating: a 3-year follow-up study addressing the influence of prosthesis design and preoperative bone density on periprosthetic bone loss. Osteoporos Int 15:281–289CrossRefPubMed Rahmy AI, Gosens T, Blake GM, Tonino A, Fogelman I (2004) Periprosthetic bone remodelling of two types of uncemented femoral implant with proximal hydroxyapatite coating: a 3-year follow-up study addressing the influence of prosthesis design and preoperative bone density on periprosthetic bone loss. Osteoporos Int 15:281–289CrossRefPubMed
16.
Zurück zum Zitat Tadross TS, Nanu AM, Buchanan MJ, Checketts RG (2000) Dall–Miles plating for periprosthetic B1 fractures of the femur. J Arthroplasty 15:47–51CrossRefPubMed Tadross TS, Nanu AM, Buchanan MJ, Checketts RG (2000) Dall–Miles plating for periprosthetic B1 fractures of the femur. J Arthroplasty 15:47–51CrossRefPubMed
17.
Zurück zum Zitat Tonino AJ, Rahmy AI (2000) The hydroxyapatite-ABG hip system: 5- to 7-year results from an international multicentre study. The International ABG Study Group. J Arthroplasty 15:274–282CrossRefPubMed Tonino AJ, Rahmy AI (2000) The hydroxyapatite-ABG hip system: 5- to 7-year results from an international multicentre study. The International ABG Study Group. J Arthroplasty 15:274–282CrossRefPubMed
18.
Zurück zum Zitat Tonino AJ, Therin M, Doyle C (1999) Hydroxyapatite-coated femoral stems. Histology and histomorphometry around five components retrieved at post mortem, J Bone Joint Surg Br 81:148–154CrossRefPubMed Tonino AJ, Therin M, Doyle C (1999) Hydroxyapatite-coated femoral stems. Histology and histomorphometry around five components retrieved at post mortem, J Bone Joint Surg Br 81:148–154CrossRefPubMed
19.
Zurück zum Zitat Tower SS, Beals RK (1999) Fractures of the femur after hip replacement: the Oregon experience. Orthop Clin North Am 30:235–247PubMed Tower SS, Beals RK (1999) Fractures of the femur after hip replacement: the Oregon experience. Orthop Clin North Am 30:235–247PubMed
20.
Zurück zum Zitat van Rietbergen B, Huiskes R (2001) Load transfer and stress shielding of the hydroxyapatite-ABG hip: a study of stem length and proximal fixation. J Arthroplasty 16:55–63CrossRef van Rietbergen B, Huiskes R (2001) Load transfer and stress shielding of the hydroxyapatite-ABG hip: a study of stem length and proximal fixation. J Arthroplasty 16:55–63CrossRef
21.
Zurück zum Zitat Wu CC, Au MK, Wu SS, Lin LC (1999) Risk factors for postoperative femoral fracture in cementless hip arthroplasty. J Formos Med Assoc 98:190–194PubMed Wu CC, Au MK, Wu SS, Lin LC (1999) Risk factors for postoperative femoral fracture in cementless hip arthroplasty. J Formos Med Assoc 98:190–194PubMed
Metadaten
Titel
Periprosthetic fractures around cementless hydroxyapatite-coated femoral stems
Publikationsdatum
01.08.2005
Erschienen in
International Orthopaedics / Ausgabe 4/2005
Print ISSN: 0341-2695
Elektronische ISSN: 1432-5195
DOI
https://doi.org/10.1007/s00264-005-0657-3

Weitere Artikel der Ausgabe 4/2005

International Orthopaedics 4/2005 Zur Ausgabe

Arthropedia

Grundlagenwissen der Arthroskopie und Gelenkchirurgie. Erweitert durch Fallbeispiele, Videos und Abbildungen. 
» Jetzt entdecken

Update Orthopädie und Unfallchirurgie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.