Skip to main content
Erschienen in: International Orthopaedics 5/2009

01.10.2009 | Original Paper

Intramedullary screw fixation for midshaft fractures of the clavicle

verfasst von: Ayman Khalil

Erschienen in: International Orthopaedics | Ausgabe 5/2009

Einloggen, um Zugang zu erhalten

Abstract

Open intramedullary fixation of 37 fresh midshaft clavicular fractures in 35 patients was performed using a 6.5 partially threaded cancellous screw. Mean age was 38 years (range 18–65). The screw was inserted from the medial fragment after retrograde drilling of that fragment. Average follow-up period was 21 months (range 9–36). Radiological evidence of union was apparent in all cases within six to eight weeks after surgery (mean 7.8). Two cases had intraoperative failure of fixation, nine complained of subcutaneous prominence of the screw head, five experienced decreased sensation over the site of incision, and three had symptoms of frozen shoulder. In conclusion, the technique is simple, affordable and it does not require special instrumentation or implants. It allows intramedullary compression, stability, stress sharing, minimal periosteal stripping, and early recovery after surgery.
Literatur
1.
Zurück zum Zitat Grassi FA, Tajana MS, D’Angelo F (2001) Management of midclavicular fractures: comparison between nonoperative treatment and open intramedullary fixation in 80 patients. J Trauma 50(6):1096–1100PubMedCrossRef Grassi FA, Tajana MS, D’Angelo F (2001) Management of midclavicular fractures: comparison between nonoperative treatment and open intramedullary fixation in 80 patients. J Trauma 50(6):1096–1100PubMedCrossRef
2.
Zurück zum Zitat Denard PJ, Koval KJ, Cantu RV, Weinstein JN (2005) Management of midshaft clavicle fractures in adults. Am J Orthop 34(11):527–536PubMed Denard PJ, Koval KJ, Cantu RV, Weinstein JN (2005) Management of midshaft clavicle fractures in adults. Am J Orthop 34(11):527–536PubMed
3.
Zurück zum Zitat Gossard JM (1998) Closed treatment of displaced middle-third fractures of the clavicle gives poor results. J Bone Joint Surg Br 80(3):558PubMed Gossard JM (1998) Closed treatment of displaced middle-third fractures of the clavicle gives poor results. J Bone Joint Surg Br 80(3):558PubMed
4.
Zurück zum Zitat Enneking TJMQ, Hartlief MT, Fontijne WPJ (1999) Rush pin fixation for midshaft clavicular nonunions: good results in 13/14 cases. Acta Orthop Scand 70:514–516PubMedCrossRef Enneking TJMQ, Hartlief MT, Fontijne WPJ (1999) Rush pin fixation for midshaft clavicular nonunions: good results in 13/14 cases. Acta Orthop Scand 70:514–516PubMedCrossRef
5.
Zurück zum Zitat Wick M, Müller EJ, Kollig E, Muhr G (2001) Midshaft fractures of the clavicle with a shortening of more than 2 cm predispose to nonunion. Arch Orthop Trauma Surg 121(4):207–211PubMedCrossRef Wick M, Müller EJ, Kollig E, Muhr G (2001) Midshaft fractures of the clavicle with a shortening of more than 2 cm predispose to nonunion. Arch Orthop Trauma Surg 121(4):207–211PubMedCrossRef
6.
Zurück zum Zitat Chu CM, Wang SJ, Lin LC (2002) Fixation of mid-third clavicular fractures with knowles pins: 78 patients followed for 2–7 years. Acta Orthop Scand 73(2):134–139PubMedCrossRef Chu CM, Wang SJ, Lin LC (2002) Fixation of mid-third clavicular fractures with knowles pins: 78 patients followed for 2–7 years. Acta Orthop Scand 73(2):134–139PubMedCrossRef
7.
Zurück zum Zitat Ripstein CB (1948) Kirschner wire fixation in fractures of the clavicle. Can Med Assoc J 59(3):255–257PubMed Ripstein CB (1948) Kirschner wire fixation in fractures of the clavicle. Can Med Assoc J 59(3):255–257PubMed
8.
Zurück zum Zitat Ngarmukos C, Parkpian V, Patradul A (1998) Fixation of fractures of the midshaft of the clavicle with Kirschner wires. Results in 108 patients. J Bone Joint Surg Br 80(1):106–108PubMedCrossRef Ngarmukos C, Parkpian V, Patradul A (1998) Fixation of fractures of the midshaft of the clavicle with Kirschner wires. Results in 108 patients. J Bone Joint Surg Br 80(1):106–108PubMedCrossRef
9.
Zurück zum Zitat Capicotto PN, Heiple KG, Wilbur JH (1994) Midshaft clavicle nonunions treated with intramedullary Steinman pin fixation and onlay bone graft. J Orthop Trauma 8(2):88–93PubMedCrossRef Capicotto PN, Heiple KG, Wilbur JH (1994) Midshaft clavicle nonunions treated with intramedullary Steinman pin fixation and onlay bone graft. J Orthop Trauma 8(2):88–93PubMedCrossRef
10.
Zurück zum Zitat Strauss EJ, Egol KA, France MA, Koval KJ, Zuckerman JD (2007) Complications of intramedullary Hagie pin fixation for acute midshaft clavicle fractures. J Shoulder Elbow Surg 16(3):280–284PubMedCrossRef Strauss EJ, Egol KA, France MA, Koval KJ, Zuckerman JD (2007) Complications of intramedullary Hagie pin fixation for acute midshaft clavicle fractures. J Shoulder Elbow Surg 16(3):280–284PubMedCrossRef
11.
Zurück zum Zitat Jubel A, Andermahr J, Schiffer G, Tsironis K, Rehm KE (2003) Elastic stable intramedullary nailing of midclavicular fractures with a titanium nail. Clin Orthop Relat Res 408:279–285PubMedCrossRef Jubel A, Andermahr J, Schiffer G, Tsironis K, Rehm KE (2003) Elastic stable intramedullary nailing of midclavicular fractures with a titanium nail. Clin Orthop Relat Res 408:279–285PubMedCrossRef
12.
Zurück zum Zitat Schuind F, Pay-Pay E, Andrianne Y, Donkerwolcke M, Rasquin C, Burny F (1988) External fixation of the clavicle for fracture or non-union in adults. J Bone Joint Surg Am 70(5):692–695PubMed Schuind F, Pay-Pay E, Andrianne Y, Donkerwolcke M, Rasquin C, Burny F (1988) External fixation of the clavicle for fracture or non-union in adults. J Bone Joint Surg Am 70(5):692–695PubMed
13.
Zurück zum Zitat Shen WJ, Liu TJ, Shen YS (1999) Plate fixation of fresh displaced midshaft clavicle fractures. Injury 30(7):497–500PubMedCrossRef Shen WJ, Liu TJ, Shen YS (1999) Plate fixation of fresh displaced midshaft clavicle fractures. Injury 30(7):497–500PubMedCrossRef
14.
Zurück zum Zitat Beaton DE, Wright JG, Katz JN (2005) Development of the quick DASH: complication of three item approaches. J Bone Joint Surg Am 87:1038–1046PubMedCrossRef Beaton DE, Wright JG, Katz JN (2005) Development of the quick DASH: complication of three item approaches. J Bone Joint Surg Am 87:1038–1046PubMedCrossRef
15.
Zurück zum Zitat Böstman O, Manninen M, Pihlajamäki H (1997) Complications of plate fixation in fresh displaced midclavicular fractures. Trauma 43(5):778–783CrossRef Böstman O, Manninen M, Pihlajamäki H (1997) Complications of plate fixation in fresh displaced midclavicular fractures. Trauma 43(5):778–783CrossRef
16.
Zurück zum Zitat Liu PC, Hsieh CH, Chen JC, Lu CC, Chuo CY, Chien SH (2008) Infection after surgical reconstruction of a clavicle fracture using a reconstruction plate: a report of seven cases. Kaohsiung J Med Sci 24(1):45–49PubMedCrossRef Liu PC, Hsieh CH, Chen JC, Lu CC, Chuo CY, Chien SH (2008) Infection after surgical reconstruction of a clavicle fracture using a reconstruction plate: a report of seven cases. Kaohsiung J Med Sci 24(1):45–49PubMedCrossRef
17.
Zurück zum Zitat Leppilahti J, Jalovaara P (1999) Migration of Kirschner wires following fixation of the clavicle–a report of 2 cases. Acta Orthop Scand 70(5):517–509PubMed Leppilahti J, Jalovaara P (1999) Migration of Kirschner wires following fixation of the clavicle–a report of 2 cases. Acta Orthop Scand 70(5):517–509PubMed
18.
Zurück zum Zitat Regel JP, Pospiech J, Aalders TA, Ruchholtz S (2002) Intraspinal migration of a Kirschner wire 3 months after clavicular fracture fixation. Neurosurg Rev 25(1–2):110–112PubMed Regel JP, Pospiech J, Aalders TA, Ruchholtz S (2002) Intraspinal migration of a Kirschner wire 3 months after clavicular fracture fixation. Neurosurg Rev 25(1–2):110–112PubMed
19.
Zurück zum Zitat Papagelopoulos PJ, Papadopoulos ECh, Savvidou OD, Kaseta MA, Themistocleous GS, Milas FG (2005) Acute thoracic outlet syndrome after internal fixation of a clavicle pseudarthrosis. Orthopedics 28(6):606–608PubMed Papagelopoulos PJ, Papadopoulos ECh, Savvidou OD, Kaseta MA, Themistocleous GS, Milas FG (2005) Acute thoracic outlet syndrome after internal fixation of a clavicle pseudarthrosis. Orthopedics 28(6):606–608PubMed
20.
Zurück zum Zitat Fransen P, Bourgeois S, Rommens J (2007) Kirschner wire migration causing spinal cord injury one year after internal fixation of a clavicle fracture. Acta Orthop Belg 73(3):390–392PubMed Fransen P, Bourgeois S, Rommens J (2007) Kirschner wire migration causing spinal cord injury one year after internal fixation of a clavicle fracture. Acta Orthop Belg 73(3):390–392PubMed
Metadaten
Titel
Intramedullary screw fixation for midshaft fractures of the clavicle
verfasst von
Ayman Khalil
Publikationsdatum
01.10.2009
Verlag
Springer-Verlag
Erschienen in
International Orthopaedics / Ausgabe 5/2009
Print ISSN: 0341-2695
Elektronische ISSN: 1432-5195
DOI
https://doi.org/10.1007/s00264-009-0724-2

Weitere Artikel der Ausgabe 5/2009

International Orthopaedics 5/2009 Zur Ausgabe

Arthropedia

Grundlagenwissen der Arthroskopie und Gelenkchirurgie. Erweitert durch Fallbeispiele, Videos und Abbildungen. 
» Jetzt entdecken

Update Orthopädie und Unfallchirurgie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.