Pulsed lavage reduces the incidence of radiolucent lines under the tibial tray of Oxford unicompartmental knee arthroplasty

Pulsed lavage versus syringe lavage

verfasst von: Michael Clarius, Christian Hauck, Joern B. Seeger, Andrew James, David W. Murray, Peter R. Aldinger

Erschienen in: International Orthopaedics | Ausgabe 6/2009

Einloggen, um Zugang zu erhalten

Abstract

The aim of the study was to determine whether the incidence of radiolucencies can be reduced using pulsed lavage before cementing the tibia in unicompartmental knee arthroplasty (UKA). We prospectively studied a consecutive series of 112 cemented Oxford UKA in 100 patients in two centres. In group A (n = 56) pulsed lavage and in group B (n = 56) conventional syringe lavage was used to clean the cancellous bone. The same standardised cementing technique was applied in all cases. At a minimum follow-up of one year patients were evaluated clinically and screened radiographs were obtained. The cement bone interface under the tibial plateau was divided into four zones and evaluated for the presence of radiolucent lines. All radiographs were evaluated (n = 112), and radiolucencies in all four zones were found in two cases in group A (4%) and in 12 cases in group B (22%) (p = 0.0149). Cement penetration showed a median of 2.6 mm (group A) and 1.5 mm (group B) (p < 0.0001). We recommend the routine use of pulsed lavage in Oxford UKA to reduce the incidence of radiolucency and to improve long-term fixation.
Literatur
1.
Zurück zum Zitat Askew MJ, Steege JW, Lewis JL et al (1984) Effect of cement pressure and bone strength on polymethylmethacrylate fixation. J Orthop Res 1:412–420CrossRefPubMed Askew MJ, Steege JW, Lewis JL et al (1984) Effect of cement pressure and bone strength on polymethylmethacrylate fixation. J Orthop Res 1:412–420CrossRefPubMed
2.
Zurück zum Zitat Breusch SJ, Norman TL, Schneider U et al (2000) Lavage technique in total hip arthroplasty: jet lavage produces better cement penetration than syringe lavage in the proximal femur. J Arthroplasty 15:921–927CrossRefPubMed Breusch SJ, Norman TL, Schneider U et al (2000) Lavage technique in total hip arthroplasty: jet lavage produces better cement penetration than syringe lavage in the proximal femur. J Arthroplasty 15:921–927CrossRefPubMed
3.
Zurück zum Zitat Breusch SJ, Schneider U, Reitzel T et al (2001) Significance of jet lavage for in vitro and in vivo cement penetration. Z Orthop Ihre Grenzgeb 139:52–63CrossRefPubMed Breusch SJ, Schneider U, Reitzel T et al (2001) Significance of jet lavage for in vitro and in vivo cement penetration. Z Orthop Ihre Grenzgeb 139:52–63CrossRefPubMed
4.
Zurück zum Zitat Duus BR, Boeckstyns M, Kjaer L et al (1987) Radionuclide scanning after total knee replacement: correlation with pain and radiolucent lines. A prospective study. Invest Radiol 22:891–894CrossRefPubMed Duus BR, Boeckstyns M, Kjaer L et al (1987) Radionuclide scanning after total knee replacement: correlation with pain and radiolucent lines. A prospective study. Invest Radiol 22:891–894CrossRefPubMed
5.
Zurück zum Zitat Ecker ML, Lotke PA, Windsor RE et al (1987) Long-term results after total condylar knee arthroplasty. Significance of radiolucent lines. Clin Orthop Relat Res 216:151–158PubMed Ecker ML, Lotke PA, Windsor RE et al (1987) Long-term results after total condylar knee arthroplasty. Significance of radiolucent lines. Clin Orthop Relat Res 216:151–158PubMed
6.
Zurück zum Zitat Garcia-Cimbrelo E, Diez-Vazquez V, Madero R et al (1997) Progression of radiolucent lines adjacent to the acetabular component and factors influencing migration after Charnley low-friction total hip arthroplasty. J Bone Joint Surg Am 79:1373–1380PubMed Garcia-Cimbrelo E, Diez-Vazquez V, Madero R et al (1997) Progression of radiolucent lines adjacent to the acetabular component and factors influencing migration after Charnley low-friction total hip arthroplasty. J Bone Joint Surg Am 79:1373–1380PubMed
7.
Zurück zum Zitat Gisep A, Curtis R, Flutsch S et al (2006) Augmentation of osteoporotic bone: effect of pulsed jet-lavage on injection forces, cement distribution, and push-out strength of implants. J Biomed Mater Res B Appl Biomater 78:83–88PubMed Gisep A, Curtis R, Flutsch S et al (2006) Augmentation of osteoporotic bone: effect of pulsed jet-lavage on injection forces, cement distribution, and push-out strength of implants. J Biomed Mater Res B Appl Biomater 78:83–88PubMed
8.
Zurück zum Zitat Goodfellow JW, O’Connor JJ, Dodd CAF et al (2006) Unicompartmental arthroplasty with the Oxford knee. Oxford University Press, UK Goodfellow JW, O’Connor JJ, Dodd CAF et al (2006) Unicompartmental arthroplasty with the Oxford knee. Oxford University Press, UK
9.
Zurück zum Zitat Guha AR, Debnath UK, Graham NM (2008) Radiolucent lines below the tibial component of a total knee replacement (TKR)—a comparison between single-and two-stage cementation techniques. Int Orthop 32:453–457CrossRefPubMed Guha AR, Debnath UK, Graham NM (2008) Radiolucent lines below the tibial component of a total knee replacement (TKR)—a comparison between single-and two-stage cementation techniques. Int Orthop 32:453–457CrossRefPubMed
10.
Zurück zum Zitat Halawa M, Lee AJ, Ling RS et al (1978) The shear strength of trabecular bone from the femur, and some factors affecting the shear strength of the cement-bone interface. Arch Orthop Trauma Surg 92:19–30CrossRefPubMed Halawa M, Lee AJ, Ling RS et al (1978) The shear strength of trabecular bone from the femur, and some factors affecting the shear strength of the cement-bone interface. Arch Orthop Trauma Surg 92:19–30CrossRefPubMed
11.
Zurück zum Zitat Iwaki H, Scott G, Freeman MA (2002) The natural history and significance of radiolucent lines at a cemented femoral interface. J Bone Joint Surg Br 84:550–555CrossRefPubMed Iwaki H, Scott G, Freeman MA (2002) The natural history and significance of radiolucent lines at a cemented femoral interface. J Bone Joint Surg Br 84:550–555CrossRefPubMed
12.
Zurück zum Zitat Krause WR, Krug W, Miller J (1982) Strength of the cement-bone interface. Clin Orthop Relat Res 163:290–299PubMed Krause WR, Krug W, Miller J (1982) Strength of the cement-bone interface. Clin Orthop Relat Res 163:290–299PubMed
13.
Zurück zum Zitat Lee C (2005) The importance of establishing the best bone-cement interface. In: Breusch S, Malchau H (ed) The well-cemented total hip arthroplasty—theory and practice. Springer Verlag, Heidelberg Lee C (2005) The importance of establishing the best bone-cement interface. In: Breusch S, Malchau H (ed) The well-cemented total hip arthroplasty—theory and practice. Springer Verlag, Heidelberg
14.
Zurück zum Zitat Ling RS (1986) Observations on the fixation of implants to the bony skeleton. Clin Orthop Relat Res 210:80–96PubMed Ling RS (1986) Observations on the fixation of implants to the bony skeleton. Clin Orthop Relat Res 210:80–96PubMed
15.
Zurück zum Zitat MacDonald W, Swarts E, Beaver R (1993) Penetration and shear strength of cement-bone interfaces in vivo. Clin Orthop Relat Res 286:283–288PubMed MacDonald W, Swarts E, Beaver R (1993) Penetration and shear strength of cement-bone interfaces in vivo. Clin Orthop Relat Res 286:283–288PubMed
16.
Zurück zum Zitat Mann KA, Ayers DC, Werner FW et al (1997) Tensile strength of the cement-bone interface depends on the amount of bone interdigitated with PMMA cement. J Biomech 30:339–346CrossRefPubMed Mann KA, Ayers DC, Werner FW et al (1997) Tensile strength of the cement-bone interface depends on the amount of bone interdigitated with PMMA cement. J Biomech 30:339–346CrossRefPubMed
17.
Zurück zum Zitat Pandit H, Jenkins C, Barker K et al (2006) The Oxford medial unicompartmental knee replacement using a minimally-invasive approach. J Bone Joint Surg Br 88:54–60CrossRefPubMed Pandit H, Jenkins C, Barker K et al (2006) The Oxford medial unicompartmental knee replacement using a minimally-invasive approach. J Bone Joint Surg Br 88:54–60CrossRefPubMed
18.
Zurück zum Zitat Price AJ, Waite JC, Svard U (2005) Long-term clinical results of the medial Oxford unicompartmental knee arthroplasty. Clin Orthop Relat Res 435:171–180CrossRefPubMed Price AJ, Waite JC, Svard U (2005) Long-term clinical results of the medial Oxford unicompartmental knee arthroplasty. Clin Orthop Relat Res 435:171–180CrossRefPubMed
19.
Zurück zum Zitat Ranawat CS, Peters LE, Umlas ME (1997) Fixation of the acetabular component. The case for cement. Clin Orthop Relat Res 344:207–215CrossRefPubMed Ranawat CS, Peters LE, Umlas ME (1997) Fixation of the acetabular component. The case for cement. Clin Orthop Relat Res 344:207–215CrossRefPubMed
20.
Zurück zum Zitat Rea P, Short A, Pandit H et al (2007) Radiolucency and migration after Oxford unicompartmental knee arthroplasty. Orthopedics 30:24–27PubMed Rea P, Short A, Pandit H et al (2007) Radiolucency and migration after Oxford unicompartmental knee arthroplasty. Orthopedics 30:24–27PubMed
21.
Zurück zum Zitat Reading AD, McCaskie AW, Barnes MR et al (2000) A comparison of 2 modern femoral cementing techniques: analysis by cement-bone interface pressure measurements, computerized image analysis, and static mechanical testing. J Arthroplasty 15:479–487CrossRefPubMed Reading AD, McCaskie AW, Barnes MR et al (2000) A comparison of 2 modern femoral cementing techniques: analysis by cement-bone interface pressure measurements, computerized image analysis, and static mechanical testing. J Arthroplasty 15:479–487CrossRefPubMed
22.
Zurück zum Zitat Ritter MA, Zhou H, Keating CM et al (1999) Radiological factors influencing femoral and acetabular failure in cemented Charnley total hip arthroplasties. J Bone Joint Surg Br 81:982–986CrossRefPubMed Ritter MA, Zhou H, Keating CM et al (1999) Radiological factors influencing femoral and acetabular failure in cemented Charnley total hip arthroplasties. J Bone Joint Surg Br 81:982–986CrossRefPubMed
23.
Zurück zum Zitat Smith S, Naima VS, Freeman MA (1999) The natural history of tibial radiolucent lines in a proximally cemented stemmed total knee arthroplasty. J Arthroplasty 14:3–8CrossRefPubMed Smith S, Naima VS, Freeman MA (1999) The natural history of tibial radiolucent lines in a proximally cemented stemmed total knee arthroplasty. J Arthroplasty 14:3–8CrossRefPubMed
24.
Zurück zum Zitat Stone JJ, Rand JA, Chiu EK et al (1996) Cement viscosity affects the bone-cement interface in total hip arthroplasty. J Orthop Res 14:834–837CrossRefPubMed Stone JJ, Rand JA, Chiu EK et al (1996) Cement viscosity affects the bone-cement interface in total hip arthroplasty. J Orthop Res 14:834–837CrossRefPubMed
25.
Zurück zum Zitat Tibrewal SB, Grant KA, Goodfellow JW (1984) The radiolucent line beneath the tibial components of the Oxford meniscal knee. J Bone Joint Surg Br 66:523–528PubMed Tibrewal SB, Grant KA, Goodfellow JW (1984) The radiolucent line beneath the tibial components of the Oxford meniscal knee. J Bone Joint Surg Br 66:523–528PubMed
26.
Zurück zum Zitat Weale AE, Murray DW, Crawford R et al (1999) Does arthritis progress in the retained compartments after ‘Oxford’ medial unicompartmental arthroplasty? A clinical and radiological study with a minimum ten-year follow-up. J Bone Joint Surg Br 81:783–789CrossRefPubMed Weale AE, Murray DW, Crawford R et al (1999) Does arthritis progress in the retained compartments after ‘Oxford’ medial unicompartmental arthroplasty? A clinical and radiological study with a minimum ten-year follow-up. J Bone Joint Surg Br 81:783–789CrossRefPubMed
27.
Zurück zum Zitat Wirtz D, Sellei RM, Portheine F et al (2001) Effect of femoral intramedullary irrigation on periprosthetic cement distribution: jet lavage versus syringe lavage. Z Orthop Ihre Grenzgeb 139:410–414CrossRefPubMed Wirtz D, Sellei RM, Portheine F et al (2001) Effect of femoral intramedullary irrigation on periprosthetic cement distribution: jet lavage versus syringe lavage. Z Orthop Ihre Grenzgeb 139:410–414CrossRefPubMed
Metadaten
Titel
Pulsed lavage reduces the incidence of radiolucent lines under the tibial tray of Oxford unicompartmental knee arthroplasty
Pulsed lavage versus syringe lavage
verfasst von
Michael Clarius
Christian Hauck
Joern B. Seeger
Andrew James
David W. Murray
Peter R. Aldinger
Publikationsdatum
01.12.2009
Verlag
Springer-Verlag
Erschienen in
International Orthopaedics / Ausgabe 6/2009
Print ISSN: 0341-2695
Elektronische ISSN: 1432-5195
DOI
https://doi.org/10.1007/s00264-009-0736-y

Weitere Artikel der Ausgabe 6/2009

International Orthopaedics 6/2009 Zur Ausgabe

Arthropedia

Grundlagenwissen der Arthroskopie und Gelenkchirurgie. Erweitert durch Fallbeispiele, Videos und Abbildungen. 
» Jetzt entdecken

Update Orthopädie und Unfallchirurgie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.