In a prospective clinical study, 59 patients with anteromedial osteoarthritis of the knee (61 knee joints) underwent minimally invasive medial Oxford unicompartmental arthroplasty phase 3. Clinical and radiographic examinations of 56 knees were carried out at five (4–7) years. American Knee Society (AKS) scores improved from mean 45.5 (20–80) points (knee score) and 55 (15–100) points (function score) before surgery to 90 (30–100) points in both scores after surgery. The position of each implant was determined on screened radiographs using an image intensifier. The implant position was analysed according to the Oxford X-ray rating system. We evaluated nine measures, and there was no detectable correlation between implant position and clinical result. However, long-term studies are needed before it is possible to elaborate an evidence-based guideline on positioning.
Literatur
1.
Zurück zum Zitat Aldinger PR, Clarius M, Murray DW et al (2004) Medial unicompartmental knee replacement using the “Oxford Uni” meniscal bearing knee. Orthopade 33(11):1277–1283PubMedCrossRef Aldinger PR, Clarius M, Murray DW et al (2004) Medial unicompartmental knee replacement using the “Oxford Uni” meniscal bearing knee. Orthopade 33(11):1277–1283PubMedCrossRef
2.
Zurück zum Zitat Aldinger PR, Gill HS, Schlegel U et al (2005) Is computer navigation a useful tool in unicompartmental knee arthroplasty? A pilot cadaver study. Orthopade 34(11):1096–1102 1094CrossRef Aldinger PR, Gill HS, Schlegel U et al (2005) Is computer navigation a useful tool in unicompartmental knee arthroplasty? A pilot cadaver study. Orthopade 34(11):1096–1102 1094CrossRef
3.
Zurück zum Zitat Bargren JH, Blaha JD, Freeman MA (1983) Alignment in total knee arthroplasty. Correlated biomechanical and clinical observations. Clin Orthop Relat Res 173:178–183PubMed Bargren JH, Blaha JD, Freeman MA (1983) Alignment in total knee arthroplasty. Correlated biomechanical and clinical observations. Clin Orthop Relat Res 173:178–183PubMed
4.
Zurück zum Zitat Benjamin J (2006) Component alignment in total knee arthroplasty. Instr Course Lect 55:405–412PubMed Benjamin J (2006) Component alignment in total knee arthroplasty. Instr Course Lect 55:405–412PubMed
5.
Zurück zum Zitat Clarius M, Hauck C, Seeger JB et al (2009) Pulsed lavage reduces the incidence of radiolucent lines under the tibial tray of Oxford unicompartmental knee arthroplasty : Pulsed lavage versus syringe lavage. Int Orthop Feb 14 (doi:10.1007/s00264-009-0736-y) Clarius M, Hauck C, Seeger JB et al (2009) Pulsed lavage reduces the incidence of radiolucent lines under the tibial tray of Oxford unicompartmental knee arthroplasty : Pulsed lavage versus syringe lavage. Int Orthop Feb 14 (doi:10.​1007/​s00264-009-0736-y)
6.
Zurück zum Zitat Fisher N, Agarwal M, Reuben SF et al (2006) Sporting and physical activity following Oxford medial unicompartmental knee arthroplasty. Knee 13(4):296–300PubMedCrossRef Fisher N, Agarwal M, Reuben SF et al (2006) Sporting and physical activity following Oxford medial unicompartmental knee arthroplasty. Knee 13(4):296–300PubMedCrossRef
7.
Zurück zum Zitat Goodfellow J, O’Connor J, Murray DW (2002) The Oxford meniscal unicompartmental knee. J Knee Surg 15(4):240–246PubMed Goodfellow J, O’Connor J, Murray DW (2002) The Oxford meniscal unicompartmental knee. J Knee Surg 15(4):240–246PubMed
8.
Zurück zum Zitat Insall JN, Dorr LD, Scott RD et al (1989) Rationale of the Knee Society clinical rating system. Clin Orthop Relat Res 248:13–14PubMed Insall JN, Dorr LD, Scott RD et al (1989) Rationale of the Knee Society clinical rating system. Clin Orthop Relat Res 248:13–14PubMed
9.
Zurück zum Zitat Jahromi I, Walton NP, Dobson PJ et al (2004) Patient-perceived outcome measures following unicompartmental knee arthroplasty with mini-incision. Int Orthop 28(5):286–289PubMedCrossRef Jahromi I, Walton NP, Dobson PJ et al (2004) Patient-perceived outcome measures following unicompartmental knee arthroplasty with mini-incision. Int Orthop 28(5):286–289PubMedCrossRef
10.
Zurück zum Zitat Jeer PJ, Keene GC, Gill P (2004) Unicompartmental knee arthroplasty: an intermediate report of survivorship after the introduction of a new system with analysis of failures. Knee 11(5):369–374PubMedCrossRef Jeer PJ, Keene GC, Gill P (2004) Unicompartmental knee arthroplasty: an intermediate report of survivorship after the introduction of a new system with analysis of failures. Knee 11(5):369–374PubMedCrossRef
11.
Zurück zum Zitat Jeffcote B, Shakespeare D (2003) Varus/valgus alignment of the tibial component in total knee arthroplasty. Knee 10(3):243–247PubMedCrossRef Jeffcote B, Shakespeare D (2003) Varus/valgus alignment of the tibial component in total knee arthroplasty. Knee 10(3):243–247PubMedCrossRef
12.
Zurück zum Zitat Kasodekar VB, Yeo SJ, Othman S (2006) Clinical outcome of unicompartmental knee arthroplasty and influence of alignment on prosthesis survival rate. Singapore Med J 47(9):796–802PubMed Kasodekar VB, Yeo SJ, Othman S (2006) Clinical outcome of unicompartmental knee arthroplasty and influence of alignment on prosthesis survival rate. Singapore Med J 47(9):796–802PubMed
13.
Zurück zum Zitat Keys GW, Ul-Abiddin Z, Toh EM (2004) Analysis of first forty Oxford medial unicompartmental knee replacement from a small district hospital in UK. Knee 11(5):375–377PubMedCrossRef Keys GW, Ul-Abiddin Z, Toh EM (2004) Analysis of first forty Oxford medial unicompartmental knee replacement from a small district hospital in UK. Knee 11(5):375–377PubMedCrossRef
14.
Zurück zum Zitat Lam LO, Shakespeare D (2003) Varus/valgus alignment of the femoral component in total knee arthroplasty. Knee 10(3):237–241PubMedCrossRef Lam LO, Shakespeare D (2003) Varus/valgus alignment of the femoral component in total knee arthroplasty. Knee 10(3):237–241PubMedCrossRef
15.
Zurück zum Zitat Luscombe KL, Lim J, Jones PW et al (2006) Minimally invasive Oxford medial unicompartmental knee arthroplasty: a note of caution! Int Orthop 3183:321–324 Luscombe KL, Lim J, Jones PW et al (2006) Minimally invasive Oxford medial unicompartmental knee arthroplasty: a note of caution! Int Orthop 3183:321–324
16.
Zurück zum Zitat Muller PE, Pellengahr C, Witt M et al (2004) Influence of minimally invasive surgery on implant positioning and the functional outcome for medial unicompartmental knee arthroplasty. J Arthroplasty 19(3):296–301PubMedCrossRef Muller PE, Pellengahr C, Witt M et al (2004) Influence of minimally invasive surgery on implant positioning and the functional outcome for medial unicompartmental knee arthroplasty. J Arthroplasty 19(3):296–301PubMedCrossRef
17.
Zurück zum Zitat Murray DW (2005) Mobile bearing unicompartmental knee replacement. Orthopedics 28(9):985–987PubMed Murray DW (2005) Mobile bearing unicompartmental knee replacement. Orthopedics 28(9):985–987PubMed
18.
Zurück zum Zitat Murray DW (2000) Unicompartmental knee replacement: now or never? Orthopedics 23(9):979–980PubMed Murray DW (2000) Unicompartmental knee replacement: now or never? Orthopedics 23(9):979–980PubMed
19.
Zurück zum Zitat Murray DW, Goodfellow JW, O'Connor JJ (1998) The Oxford medial unicompartmental arthroplasty: a ten-year survival study. J Bone Joint Surg Br 80(6):983–989PubMedCrossRef Murray DW, Goodfellow JW, O'Connor JJ (1998) The Oxford medial unicompartmental arthroplasty: a ten-year survival study. J Bone Joint Surg Br 80(6):983–989PubMedCrossRef
20.
Zurück zum Zitat Pandit H, Jenkins C, Barker K et al (2006) The Oxford medial unicompartmental knee replacement using a minimally-invasive approach. J Bone Joint Surg Br 88(1):54–60PubMedCrossRef Pandit H, Jenkins C, Barker K et al (2006) The Oxford medial unicompartmental knee replacement using a minimally-invasive approach. J Bone Joint Surg Br 88(1):54–60PubMedCrossRef
21.
Zurück zum Zitat Petersen TL, Engh GA (1988) Radiographic assessment of knee alignment after total knee arthroplasty. J Arthroplasty 3(1):67–72PubMedCrossRef Petersen TL, Engh GA (1988) Radiographic assessment of knee alignment after total knee arthroplasty. J Arthroplasty 3(1):67–72PubMedCrossRef
22.
Zurück zum Zitat Price AJ, Webb J, Topf H et al (2001) Rapid recovery after oxford unicompartmental arthroplasty through a short incision. J Arthroplasty 16(8):970–976PubMedCrossRef Price AJ, Webb J, Topf H et al (2001) Rapid recovery after oxford unicompartmental arthroplasty through a short incision. J Arthroplasty 16(8):970–976PubMedCrossRef
23.
Zurück zum Zitat Rajasekhar C, Das S, Smith A (2004) Unicompartmental knee arthroplasty. 2- to 12-year results in a community hospital. J Bone Joint Surg Br 86(7):983–985PubMedCrossRef Rajasekhar C, Das S, Smith A (2004) Unicompartmental knee arthroplasty. 2- to 12-year results in a community hospital. J Bone Joint Surg Br 86(7):983–985PubMedCrossRef
24.
Zurück zum Zitat Rees JL, Price AJ, Beard DJ et al (2004) Minimally invasive Oxford unicompartmental knee arthroplasty: functional results at 1 year and the effect of surgical inexperience. Knee 11(5):363–367PubMedCrossRef Rees JL, Price AJ, Beard DJ et al (2004) Minimally invasive Oxford unicompartmental knee arthroplasty: functional results at 1 year and the effect of surgical inexperience. Knee 11(5):363–367PubMedCrossRef
25.
Zurück zum Zitat Robertsson O, Knutson K, Lewold S et al (2001) The routine of surgical management reduces failure after unicompartmental knee arthroplasty. J Bone Joint Surg Br 83(1):45–49PubMedCrossRef Robertsson O, Knutson K, Lewold S et al (2001) The routine of surgical management reduces failure after unicompartmental knee arthroplasty. J Bone Joint Surg Br 83(1):45–49PubMedCrossRef
26.
Zurück zum Zitat Saragaglia D, Estour G, Nemer C et al (2009) Revision of 33 unicompartmental knee prostheses using total knee arthroplasty: strategy and results. Int Orthop 33(4):969–974PubMedCrossRef Saragaglia D, Estour G, Nemer C et al (2009) Revision of 33 unicompartmental knee prostheses using total knee arthroplasty: strategy and results. Int Orthop 33(4):969–974PubMedCrossRef
27.
Zurück zum Zitat Shakespeare D, Ledger M, Kinzel V (2005) Accuracy of implantation of components in the Oxford knee using the minimally invasive approach. Knee 12(6):405–409PubMedCrossRef Shakespeare D, Ledger M, Kinzel V (2005) Accuracy of implantation of components in the Oxford knee using the minimally invasive approach. Knee 12(6):405–409PubMedCrossRef
28.
Zurück zum Zitat Shakespeare D, Ledger M, Kinzel V (2005) The influence of the tibial sagittal cut on component position in the Oxford knee. Knee 12(3):169–176PubMedCrossRef Shakespeare D, Ledger M, Kinzel V (2005) The influence of the tibial sagittal cut on component position in the Oxford knee. Knee 12(3):169–176PubMedCrossRef
29.
Zurück zum Zitat Smith JL Jr, Tullos HS, Davidson JP (1989) Alignment of total knee arthroplasty. J Arthroplasty 4(Suppl):S55–S61PubMedCrossRef Smith JL Jr, Tullos HS, Davidson JP (1989) Alignment of total knee arthroplasty. J Arthroplasty 4(Suppl):S55–S61PubMedCrossRef
30.
Zurück zum Zitat Squire MW, Callaghan JJ, Goetz DD et al (1999) Unicompartmental knee replacement. A minimum 15 year followup study. Clin Orthop Relat Res 367:61–72PubMedCrossRef Squire MW, Callaghan JJ, Goetz DD et al (1999) Unicompartmental knee replacement. A minimum 15 year followup study. Clin Orthop Relat Res 367:61–72PubMedCrossRef
31.
Zurück zum Zitat Svard UC, Price AJ (2001) Oxford medial unicompartmental knee arthroplasty. A survival analysis of an independent series. J Bone Joint Surg Br 83(2):191–194PubMedCrossRef Svard UC, Price AJ (2001) Oxford medial unicompartmental knee arthroplasty. A survival analysis of an independent series. J Bone Joint Surg Br 83(2):191–194PubMedCrossRef
32.
Zurück zum Zitat Verdonk R, Cottenie D, Almqvist KF et al (2005) The Oxford unicompartmental knee prosthesis: a 2–14 year follow-up. Knee Surg Sports Traumatol Arthrosc 13(3):163–166PubMedCrossRef Verdonk R, Cottenie D, Almqvist KF et al (2005) The Oxford unicompartmental knee prosthesis: a 2–14 year follow-up. Knee Surg Sports Traumatol Arthrosc 13(3):163–166PubMedCrossRef
33.
Zurück zum Zitat Vorlat P, Putzeys G, Cottenie D et al (2006) The Oxford unicompartmental knee prosthesis: an independent 10-year survival analysis. Knee Surg Sports Traumatol Arthrosc 14(1):40–45PubMedCrossRef Vorlat P, Putzeys G, Cottenie D et al (2006) The Oxford unicompartmental knee prosthesis: an independent 10-year survival analysis. Knee Surg Sports Traumatol Arthrosc 14(1):40–45PubMedCrossRef
Metadaten
Titel
Correlation of positioning and clinical results in Oxford UKA
verfasst von
Michael Clarius
Christian Hauck
Joern B. Seeger
Maria Pritsch
Christian Merle
Peter R. Aldinger
Publikationsdatum
01.12.2010
Verlag
Springer-Verlag
Erschienen in
International Orthopaedics / Ausgabe 8/2010
Print ISSN: 0341-2695
Elektronische ISSN: 1432-5195
DOI
https://doi.org/10.1007/s00264-009-0881-3

Weitere Artikel der Ausgabe 8/2010

International Orthopaedics 8/2010 Zur Ausgabe

Arthropedia

Grundlagenwissen der Arthroskopie und Gelenkchirurgie. Erweitert durch Fallbeispiele, Videos und Abbildungen. 
» Jetzt entdecken

Update Orthopädie und Unfallchirurgie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.