Skip to main content
Erschienen in: International Orthopaedics 4/2011

01.04.2011 | Original Paper

Comparison of mechanical rigidity between plate augmentation leaving the nail in situ and interlocking nail using cadaveric fracture model of the femur

verfasst von: Kyungho Park, Kwanwoo Kim, Y. S. Choi

Erschienen in: International Orthopaedics | Ausgabe 4/2011

Einloggen, um Zugang zu erhalten

Abstract

Thirteen matched pairs of cadaveric femurs were placed into two groups. In each group, a transverse fracture was created at a point 70% distal between the lesser trochanter and the adductor tubercle. One femur out of each matched pair was then stabilised with an interlocking intramedullary nail (nail only group) and the other femur was stabilised with plate augmentation after interlocking intramedullary nailing (plate augmentation group). The bending load to promote 5-mm displacement showed statistically significant differences between the plate augmentation group (mean 843.36 ± 409.13 N) and the nail only group (mean 315.02 ± 219.80 N) (p = 0.001). Torsional torque at the angle of 15 degrees showed statistically significant differences between the two groups; a mean of 2.09 ± 0.53 N·m for the plate augmentation group and a mean of 0.63 ± 0.46 N·m for the nail only group (p = 0.0001). We found a 2.6-fold increase in bending stiffness and a 3.3-fold increase in torsional stiffness in plate augmentation leaving a nail in situ compared to interlocking nailing only in the distal third fracture of femur.
Literatur
1.
Zurück zum Zitat Bankston AB, Keating DA, Simon FD (1992) The biomechanical evaluation of intramedullary nails in distal femoral shaft fractures. Clin Orthop 276:277–282PubMed Bankston AB, Keating DA, Simon FD (1992) The biomechanical evaluation of intramedullary nails in distal femoral shaft fractures. Clin Orthop 276:277–282PubMed
2.
Zurück zum Zitat Choi YS, Kim KS (2005) Plate augmentation leaving the nail in situ and bone grafting for nonunion of femoral shaft fractures. Int Orthop 29(5):287–290PubMedCrossRef Choi YS, Kim KS (2005) Plate augmentation leaving the nail in situ and bone grafting for nonunion of femoral shaft fractures. Int Orthop 29(5):287–290PubMedCrossRef
3.
Zurück zum Zitat Cole JD (1996) The vascular response of bone to internal fixation. In: Browner BD (ed) The science and practice of intramedullary nailing, 2nd edn. Willians and Wilkins, pp 43–69 Cole JD (1996) The vascular response of bone to internal fixation. In: Browner BD (ed) The science and practice of intramedullary nailing, 2nd edn. Willians and Wilkins, pp 43–69
4.
Zurück zum Zitat Finkemeier CG, Chapman MW (2002) Treatment of femoral diaphyseal nonunions. Clin Orthop 398:223–234PubMedCrossRef Finkemeier CG, Chapman MW (2002) Treatment of femoral diaphyseal nonunions. Clin Orthop 398:223–234PubMedCrossRef
5.
Zurück zum Zitat Hak DJ, Lee SS, Goulet JA (2000) Success of exchange reamed intramedullary nailing for femoral shaft nonunion or delayed union. J Orthop Trauma 14:178–182PubMedCrossRef Hak DJ, Lee SS, Goulet JA (2000) Success of exchange reamed intramedullary nailing for femoral shaft nonunion or delayed union. J Orthop Trauma 14:178–182PubMedCrossRef
6.
Zurück zum Zitat Johnson KD, Tencer AF, Blementhal S (1986) Biomechanical performance of locked intramedullary nailing system in comminuted femoral shaft fractures. Clin Orthop 206:151–161PubMed Johnson KD, Tencer AF, Blementhal S (1986) Biomechanical performance of locked intramedullary nailing system in comminuted femoral shaft fractures. Clin Orthop 206:151–161PubMed
7.
Zurück zum Zitat Kan WS, Zheng Q, Wang JW, Huang H, Chen PYH, XIe M, Li P (2006) Treatment of the ununited lower limb fracture with reamed intramedullary interlocking nail. Zhonghua Wai Ke Za Zhi 44(20):1417–1419PubMed Kan WS, Zheng Q, Wang JW, Huang H, Chen PYH, XIe M, Li P (2006) Treatment of the ununited lower limb fracture with reamed intramedullary interlocking nail. Zhonghua Wai Ke Za Zhi 44(20):1417–1419PubMed
8.
Zurück zum Zitat Kempf I, Grosse A, Beak GF (1985) Closed locked Intramedullary nailing. Its application to comminuted fractures of the femur. J Bone Joint Surg Am 67:709–720 Kempf I, Grosse A, Beak GF (1985) Closed locked Intramedullary nailing. Its application to comminuted fractures of the femur. J Bone Joint Surg Am 67:709–720
9.
Zurück zum Zitat Kuntscher G (1965) Intramedullary surgical technique and its place in orthopaedic surgery. J Bone Joint Surg Am 47:809–818 Kuntscher G (1965) Intramedullary surgical technique and its place in orthopaedic surgery. J Bone Joint Surg Am 47:809–818
10.
Zurück zum Zitat Kyle RF, Shcaffhausen JM, Bechtold JE (1991) Biomechanical characteristics of interlocking femoral nails in the treatment of complex femoral fractures. Clin Orthop 267:169–173PubMed Kyle RF, Shcaffhausen JM, Bechtold JE (1991) Biomechanical characteristics of interlocking femoral nails in the treatment of complex femoral fractures. Clin Orthop 267:169–173PubMed
11.
Zurück zum Zitat Nadkarni B, Srivastav S, Mittal V, Agarwal S (2008) Use of locking compression plates for long bone nonunions without removing existing intramedullary nail: review of literature and our experience. J Trauma 65(2):482–486PubMedCrossRef Nadkarni B, Srivastav S, Mittal V, Agarwal S (2008) Use of locking compression plates for long bone nonunions without removing existing intramedullary nail: review of literature and our experience. J Trauma 65(2):482–486PubMedCrossRef
12.
Zurück zum Zitat Pihlajamaki HK, Salminen ST, Bostman OM (2002) The treatment of nonunions following intramedullary nailing of femoral shaft fractures. J Orthop Trauma 16(6):394–402PubMedCrossRef Pihlajamaki HK, Salminen ST, Bostman OM (2002) The treatment of nonunions following intramedullary nailing of femoral shaft fractures. J Orthop Trauma 16(6):394–402PubMedCrossRef
13.
Zurück zum Zitat Steinberg EL, Keynan O, Sternheim A, Drexler M, Luger E (2009) Treatment of diaphyseal nonunion of the femur and tibia using an expandable nailing system. Injury 40(3):309–314PubMedCrossRef Steinberg EL, Keynan O, Sternheim A, Drexler M, Luger E (2009) Treatment of diaphyseal nonunion of the femur and tibia using an expandable nailing system. Injury 40(3):309–314PubMedCrossRef
14.
Zurück zum Zitat Tarr RR, Wiss DA (1986) The mechanics and biology of intramedullary fracture fixation. Clin Orthop 212:10–17PubMed Tarr RR, Wiss DA (1986) The mechanics and biology of intramedullary fracture fixation. Clin Orthop 212:10–17PubMed
15.
Zurück zum Zitat Ueng SWN, Chao EK, Lee SS, Shih CH (1995) Augmentative plate fixation for the management of femoral nonunion after intramedullary nailing. J Trauma 43:640–644CrossRef Ueng SWN, Chao EK, Lee SS, Shih CH (1995) Augmentative plate fixation for the management of femoral nonunion after intramedullary nailing. J Trauma 43:640–644CrossRef
16.
Zurück zum Zitat Weresh MJ, Hakanson R, Stover M, Sims SH, Kellam JK, Bosse MJ (2000) Failure of exchange reamed intramedullary nails for ununited femoral shaft fractures. J Orthop Trauma 14:335–338PubMedCrossRef Weresh MJ, Hakanson R, Stover M, Sims SH, Kellam JK, Bosse MJ (2000) Failure of exchange reamed intramedullary nails for ununited femoral shaft fractures. J Orthop Trauma 14:335–338PubMedCrossRef
17.
Zurück zum Zitat Wu CC (1997) The effect of dynamization on slowing the healing of femur shaft fractures after interlocking nailing. J Trauma 43(2):263–267PubMedCrossRef Wu CC (1997) The effect of dynamization on slowing the healing of femur shaft fractures after interlocking nailing. J Trauma 43(2):263–267PubMedCrossRef
18.
Zurück zum Zitat Zhang X, Zhong B, Sui S, Yu X, Jiang Y (2001) Treatment of distal femoral nonunion and delayed union by using a retrograde intramedullary interlocking nail. Chin J Traumatol 4(3):180–184PubMed Zhang X, Zhong B, Sui S, Yu X, Jiang Y (2001) Treatment of distal femoral nonunion and delayed union by using a retrograde intramedullary interlocking nail. Chin J Traumatol 4(3):180–184PubMed
Metadaten
Titel
Comparison of mechanical rigidity between plate augmentation leaving the nail in situ and interlocking nail using cadaveric fracture model of the femur
verfasst von
Kyungho Park
Kwanwoo Kim
Y. S. Choi
Publikationsdatum
01.04.2011
Verlag
Springer-Verlag
Erschienen in
International Orthopaedics / Ausgabe 4/2011
Print ISSN: 0341-2695
Elektronische ISSN: 1432-5195
DOI
https://doi.org/10.1007/s00264-010-0983-y

Weitere Artikel der Ausgabe 4/2011

International Orthopaedics 4/2011 Zur Ausgabe

Arthropedia

Grundlagenwissen der Arthroskopie und Gelenkchirurgie. Erweitert durch Fallbeispiele, Videos und Abbildungen. 
» Jetzt entdecken

Update Orthopädie und Unfallchirurgie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.