Skip to main content
Erschienen in: International Orthopaedics 3/2011

01.03.2011 | Original Paper

Imageless computer assisted versus conventional total knee replacement. A Bayesian meta-analysis of 23 comparative studies

verfasst von: Yaron S. Brin, Vassilios S. Nikolaou, Lawrence Joseph, David J. Zukor, John Antoniou

Erschienen in: International Orthopaedics | Ausgabe 3/2011

Einloggen, um Zugang zu erhalten

Abstract

We have undertaken a meta-analysis of the English literature, to assess the component alignment outcomes after imageless computer assisted (CAOS) total knee arthroplasty (TKA) versus conventional TKA. We reviewed 23 publications that met the inclusion criteria. Results were summarised via a Bayesian hierarchical random effects meta-analysis model. Separate analyses were conducted for prospective randomised trials alone, as well as for all randomised and observational studies. In 20 papers (4,199 TKAs) we found a reduction in outliers rate of approximately 80% in limb mechanical axis when operated with the CAOS. For the coronal femoral and tibial implants positions, the analysis included 3,058 TKAs. The analysis for the femoral implant showed a reduction in outliers rate of approximately 87% and for the tibial implant a reduction in outliers rate of approximately 80%. Imageless navigation when performing TKA improves component orientation and postoperative limb alignment. The clinical significance of these findings though has to be proven in the future.
Literatur
1.
Zurück zum Zitat Dawson J, Linsell L, Zondervan K, Rose P, Randall T, Carr A, Fitzpatrick R (2004) Epidemiology of hip and knee pain and its impact on overall health status in older adults. Rheumatology (Oxford) 43:497–504CrossRef Dawson J, Linsell L, Zondervan K, Rose P, Randall T, Carr A, Fitzpatrick R (2004) Epidemiology of hip and knee pain and its impact on overall health status in older adults. Rheumatology (Oxford) 43:497–504CrossRef
2.
Zurück zum Zitat Jinks C, Jordan K, Ong BN, Croft P (2004) A brief screening tool for knee pain in primary care (KNEST). 2. Results from a survey in the general population aged 50 and over. Rheumatology (Oxford) 43:55–61CrossRef Jinks C, Jordan K, Ong BN, Croft P (2004) A brief screening tool for knee pain in primary care (KNEST). 2. Results from a survey in the general population aged 50 and over. Rheumatology (Oxford) 43:55–61CrossRef
3.
Zurück zum Zitat McAlindon T, Zucker NV, Zucker MO (2008) 2007 OARSI recommendations for the management of hip and knee osteoarthritis: towards consensus? Osteoarthr Cartil 16:636–637PubMedCrossRef McAlindon T, Zucker NV, Zucker MO (2008) 2007 OARSI recommendations for the management of hip and knee osteoarthritis: towards consensus? Osteoarthr Cartil 16:636–637PubMedCrossRef
4.
Zurück zum Zitat Kurtz S, Mowat F, Ong K, Chan N, Lau E, Halpern M (2005) Prevalence of primary and revision total hip and knee arthroplasty in the United States from 1990 through 2002. J Bone Joint Surg Am 87:1487–1497PubMedCrossRef Kurtz S, Mowat F, Ong K, Chan N, Lau E, Halpern M (2005) Prevalence of primary and revision total hip and knee arthroplasty in the United States from 1990 through 2002. J Bone Joint Surg Am 87:1487–1497PubMedCrossRef
5.
Zurück zum Zitat Stulberg SD, Loan P, Sarin V (2002) Computer-assisted navigation in total knee replacement: results of an initial experience in thirty-five patients. J Bone Joint Surg Am 84-A(Suppl 2):90–98PubMed Stulberg SD, Loan P, Sarin V (2002) Computer-assisted navigation in total knee replacement: results of an initial experience in thirty-five patients. J Bone Joint Surg Am 84-A(Suppl 2):90–98PubMed
6.
Zurück zum Zitat Lotke PA, Ecker ML (1977) Influence of positioning of prosthesis in total knee replacement. J Bone Joint Surg Am 59:77–79PubMed Lotke PA, Ecker ML (1977) Influence of positioning of prosthesis in total knee replacement. J Bone Joint Surg Am 59:77–79PubMed
7.
Zurück zum Zitat Ritter MA, Faris PM, Keating EM, Meding JB (1994) Postoperative alignment of total knee replacement. Its effect on survival. Clin Orthop Relat Res 299:153–156 Ritter MA, Faris PM, Keating EM, Meding JB (1994) Postoperative alignment of total knee replacement. Its effect on survival. Clin Orthop Relat Res 299:153–156
8.
Zurück zum Zitat Jeffery RS, Morris RW, Denham RA (1991) Coronal alignment after total knee replacement. J Bone Joint Surg Br 73:709–714PubMed Jeffery RS, Morris RW, Denham RA (1991) Coronal alignment after total knee replacement. J Bone Joint Surg Br 73:709–714PubMed
9.
Zurück zum Zitat Hvid I, Nielsen S (1984) Total condylar knee arthroplasty. Prosthetic component positioning and radiolucent lines. Acta Orthop Scand 55:160–165PubMedCrossRef Hvid I, Nielsen S (1984) Total condylar knee arthroplasty. Prosthetic component positioning and radiolucent lines. Acta Orthop Scand 55:160–165PubMedCrossRef
10.
Zurück zum Zitat Berend ME, Ritter MA, Meding JB, Faris PM, Keating EM, Redelman R, Faris GW, Davis KE (2004) Tibial component failure mechanisms in total knee arthroplasty. Clin Orthop Relat Res 428:26–34 Berend ME, Ritter MA, Meding JB, Faris PM, Keating EM, Redelman R, Faris GW, Davis KE (2004) Tibial component failure mechanisms in total knee arthroplasty. Clin Orthop Relat Res 428:26–34
11.
Zurück zum Zitat Krackow KA, Bayers-Thering M, Phillips MJ, Mihalko WM (1999) A new technique for determining proper mechanical axis alignment during total knee arthroplasty: progress toward computer-assisted TKA. Orthopedics 22:698–702PubMed Krackow KA, Bayers-Thering M, Phillips MJ, Mihalko WM (1999) A new technique for determining proper mechanical axis alignment during total knee arthroplasty: progress toward computer-assisted TKA. Orthopedics 22:698–702PubMed
12.
Zurück zum Zitat Stiehl JB (2009) Comparison of tibial rotation in fixed and mobile bearing total knee arthroplasty using computer navigation. Int Orthop 33:679–685PubMedCrossRef Stiehl JB (2009) Comparison of tibial rotation in fixed and mobile bearing total knee arthroplasty using computer navigation. Int Orthop 33:679–685PubMedCrossRef
13.
Zurück zum Zitat Luring C, Oczipka F, Grifka J, Perlick L (2008) The computer-assisted sequential lateral soft-tissue release in total knee arthroplasty for valgus knees. Int Orthop 32:229–235PubMedCrossRef Luring C, Oczipka F, Grifka J, Perlick L (2008) The computer-assisted sequential lateral soft-tissue release in total knee arthroplasty for valgus knees. Int Orthop 32:229–235PubMedCrossRef
14.
Zurück zum Zitat Merloz P (2008) Computer-assisted knee replacement. European Instructional Course Lectures 8:154–159 Merloz P (2008) Computer-assisted knee replacement. European Instructional Course Lectures 8:154–159
15.
Zurück zum Zitat Kim YH, Kim JS, Yoon SH (2007) Alignment and orientation of the components in total knee replacement with and without navigation support: a prospective, randomised study. J Bone Joint Surg Br 89:471–476PubMedCrossRef Kim YH, Kim JS, Yoon SH (2007) Alignment and orientation of the components in total knee replacement with and without navigation support: a prospective, randomised study. J Bone Joint Surg Br 89:471–476PubMedCrossRef
16.
Zurück zum Zitat Yau WP, Chiu KY, Zuo JL, Tang WM, Ng TP (2008) Computer navigation did not improve alignment in a lower-volume total knee practice. Clin Orthop Relat Res 466:935–945PubMedCrossRef Yau WP, Chiu KY, Zuo JL, Tang WM, Ng TP (2008) Computer navigation did not improve alignment in a lower-volume total knee practice. Clin Orthop Relat Res 466:935–945PubMedCrossRef
17.
Zurück zum Zitat Malik MH, Wadia F, Porter ML (2007) Preliminary radiological evaluation of the Vector Vision CT-free knee module for implantation of the LCS knee prosthesis. Knee 14:19–21PubMedCrossRef Malik MH, Wadia F, Porter ML (2007) Preliminary radiological evaluation of the Vector Vision CT-free knee module for implantation of the LCS knee prosthesis. Knee 14:19–21PubMedCrossRef
18.
Zurück zum Zitat Kamat YD, Aurakzai KM, Adhikari AR, Matthews D, Kalairajah Y, Field RE (2009) Does computer navigation in total knee arthroplasty improve patient outcome at midterm follow-up? Int Orthop 33:1567–1570PubMedCrossRef Kamat YD, Aurakzai KM, Adhikari AR, Matthews D, Kalairajah Y, Field RE (2009) Does computer navigation in total knee arthroplasty improve patient outcome at midterm follow-up? Int Orthop 33:1567–1570PubMedCrossRef
19.
Zurück zum Zitat Bejek Z, Solyom L, Szendroi M (2007) Experiences with computer navigated total knee arthroplasty. Int Orthop 31:617–622PubMedCrossRef Bejek Z, Solyom L, Szendroi M (2007) Experiences with computer navigated total knee arthroplasty. Int Orthop 31:617–622PubMedCrossRef
20.
Zurück zum Zitat Mombert M, Van Den Daelen L, Gunst P, Missinne L (2007) Navigated total knee arthroplasty: a radiological analysis of 42 randomised cases. Acta Orthop Belg 73:49–54PubMed Mombert M, Van Den Daelen L, Gunst P, Missinne L (2007) Navigated total knee arthroplasty: a radiological analysis of 42 randomised cases. Acta Orthop Belg 73:49–54PubMed
21.
Zurück zum Zitat Stockl B, Nogler M, Rosiek R, Fischer M, Krismer M, Kessler O (2004) Navigation improves accuracy of rotational alignment in total knee arthroplasty. Clin Orthop Relat Res 426:180–186. Stockl B, Nogler M, Rosiek R, Fischer M, Krismer M, Kessler O (2004) Navigation improves accuracy of rotational alignment in total knee arthroplasty. Clin Orthop Relat Res 426:180–186.
22.
Zurück zum Zitat Decking R, Markmann Y, Fuchs J, Puhl W, Scharf HP (2005) Leg axis after computer-navigated total knee arthroplasty: a prospective randomized trial comparing computer-navigated and manual implantation. J Arthroplasty 20:282–288PubMedCrossRef Decking R, Markmann Y, Fuchs J, Puhl W, Scharf HP (2005) Leg axis after computer-navigated total knee arthroplasty: a prospective randomized trial comparing computer-navigated and manual implantation. J Arthroplasty 20:282–288PubMedCrossRef
23.
Zurück zum Zitat Sparmann M, Wolke B, Czupalla H, Banzer D, Zink A (2003) Positioning of total knee arthroplasty with and without navigation support. A prospective, randomised study. J Bone Joint Surg Br 85:830–835PubMed Sparmann M, Wolke B, Czupalla H, Banzer D, Zink A (2003) Positioning of total knee arthroplasty with and without navigation support. A prospective, randomised study. J Bone Joint Surg Br 85:830–835PubMed
24.
Zurück zum Zitat Bathis H, Perlick L, Tingart M, Luring C, Zurakowski D, Grifka J (2004) Alignment in total knee arthroplasty. A comparison of computer-assisted surgery with the conventional technique. J Bone Joint Surg Br 86:682–687PubMedCrossRef Bathis H, Perlick L, Tingart M, Luring C, Zurakowski D, Grifka J (2004) Alignment in total knee arthroplasty. A comparison of computer-assisted surgery with the conventional technique. J Bone Joint Surg Br 86:682–687PubMedCrossRef
25.
Zurück zum Zitat Chauhan SK, Scott RG, Breidahl W, Beaver RJ (2004) Computer-assisted knee arthroplasty versus a conventional jig-based technique. A randomised, prospective trial. J Bone Joint Surg Br 86:372–377PubMedCrossRef Chauhan SK, Scott RG, Breidahl W, Beaver RJ (2004) Computer-assisted knee arthroplasty versus a conventional jig-based technique. A randomised, prospective trial. J Bone Joint Surg Br 86:372–377PubMedCrossRef
26.
Zurück zum Zitat Matsumoto T, Tsumura N, Kurosaka M, Muratsu H, Kuroda R, Ishimoto K, Tsujimoto K, Shiba R, Yoshiya S (2004) Prosthetic alignment and sizing in computer-assisted total knee arthroplasty. Int Orthop 28:282–285PubMedCrossRef Matsumoto T, Tsumura N, Kurosaka M, Muratsu H, Kuroda R, Ishimoto K, Tsujimoto K, Shiba R, Yoshiya S (2004) Prosthetic alignment and sizing in computer-assisted total knee arthroplasty. Int Orthop 28:282–285PubMedCrossRef
27.
Zurück zum Zitat Ensini A, Catani F, Leardini A, Romagnoli M, Giannini S (2007) Alignments and clinical results in conventional and navigated total knee arthroplasty. Clin Orthop Relat Res 457:156–162PubMed Ensini A, Catani F, Leardini A, Romagnoli M, Giannini S (2007) Alignments and clinical results in conventional and navigated total knee arthroplasty. Clin Orthop Relat Res 457:156–162PubMed
28.
Zurück zum Zitat Matziolis G, Krocker D, Weiss U, Tohtz S, Perka C (2007) A prospective, randomized study of computer-assisted and conventional total knee arthroplasty. Three-dimensional evaluation of implant alignment and rotation. J Bone Joint Surg Am 89:236–243PubMedCrossRef Matziolis G, Krocker D, Weiss U, Tohtz S, Perka C (2007) A prospective, randomized study of computer-assisted and conventional total knee arthroplasty. Three-dimensional evaluation of implant alignment and rotation. J Bone Joint Surg Am 89:236–243PubMedCrossRef
29.
Zurück zum Zitat Martin A, Wohlgenannt O, Prenn M, Oelsch C, von Strempel A (2007) Imageless navigation for TKA increases implantation accuracy. Clin Orthop Relat Res 460:178–184PubMed Martin A, Wohlgenannt O, Prenn M, Oelsch C, von Strempel A (2007) Imageless navigation for TKA increases implantation accuracy. Clin Orthop Relat Res 460:178–184PubMed
30.
Zurück zum Zitat Mullaji A, Kanna R, Marawar S, Kohli A, Sharma A (2007) Comparison of limb and component alignment using computer-assisted navigation versus image intensifier-guided conventional total knee arthroplasty: a prospective, randomized, single-surgeon study of 467 knees. J Arthroplasty 22:953–959PubMedCrossRef Mullaji A, Kanna R, Marawar S, Kohli A, Sharma A (2007) Comparison of limb and component alignment using computer-assisted navigation versus image intensifier-guided conventional total knee arthroplasty: a prospective, randomized, single-surgeon study of 467 knees. J Arthroplasty 22:953–959PubMedCrossRef
31.
Zurück zum Zitat Oberst M, Bertsch C, Konrad G, Lahm A, Holz U (2008) CT analysis after navigated versus conventional implantation of TKA. Arch Orthop Trauma Surg 128:561–566PubMedCrossRef Oberst M, Bertsch C, Konrad G, Lahm A, Holz U (2008) CT analysis after navigated versus conventional implantation of TKA. Arch Orthop Trauma Surg 128:561–566PubMedCrossRef
32.
Zurück zum Zitat Jenny JY, Boeri C (2001) Computer-assisted implantation of total knee prostheses: a case-control comparative study with classical instrumentation. Comput Aided Surg 6:217–220PubMedCrossRef Jenny JY, Boeri C (2001) Computer-assisted implantation of total knee prostheses: a case-control comparative study with classical instrumentation. Comput Aided Surg 6:217–220PubMedCrossRef
33.
Zurück zum Zitat Haaker RG, Stockheim M, Kamp M, Proff G, Breitenfelder J, Ottersbach A (2005) Computer-assisted navigation increases precision of component placement in total knee arthroplasty. Clin Orthop Relat Res 433:152–159 Haaker RG, Stockheim M, Kamp M, Proff G, Breitenfelder J, Ottersbach A (2005) Computer-assisted navigation increases precision of component placement in total knee arthroplasty. Clin Orthop Relat Res 433:152–159
34.
Zurück zum Zitat Daubresse F, Vajeu C, Loquet J (2005) Total knee arthroplasty with conventional or navigated technique: comparison of the learning curves in a community hospital. Acta Orthop Belg 71:710–713PubMed Daubresse F, Vajeu C, Loquet J (2005) Total knee arthroplasty with conventional or navigated technique: comparison of the learning curves in a community hospital. Acta Orthop Belg 71:710–713PubMed
35.
Zurück zum Zitat Zorman D, Etuin P, Jennart H, Scipioni D, Devos S (2005) Computer-assisted total knee arthroplasty: comparative results in a preliminary series of 72 cases. Acta Orthop Belg 71:696–702PubMed Zorman D, Etuin P, Jennart H, Scipioni D, Devos S (2005) Computer-assisted total knee arthroplasty: comparative results in a preliminary series of 72 cases. Acta Orthop Belg 71:696–702PubMed
36.
Zurück zum Zitat Kim SJ, MacDonald M, Hernandez J, Wixson RL (2005) Computer assisted navigation in total knee arthroplasty: improved coronal alignment. J Arthroplasty 20:123–131PubMedCrossRef Kim SJ, MacDonald M, Hernandez J, Wixson RL (2005) Computer assisted navigation in total knee arthroplasty: improved coronal alignment. J Arthroplasty 20:123–131PubMedCrossRef
37.
Zurück zum Zitat Jenny JY, Clemens U, Kohler S, Kiefer H, Konermann W, Miehlke RK (2005) Consistency of implantation of a total knee arthroplasty with a non-image-based navigation system: a case-control study of 235 cases compared with 235 conventionally implanted prostheses. J Arthroplasty 20:832–839PubMedCrossRef Jenny JY, Clemens U, Kohler S, Kiefer H, Konermann W, Miehlke RK (2005) Consistency of implantation of a total knee arthroplasty with a non-image-based navigation system: a case-control study of 235 cases compared with 235 conventionally implanted prostheses. J Arthroplasty 20:832–839PubMedCrossRef
38.
Zurück zum Zitat Macule-Beneyto F, Hernandez-Vaquero D, Segur-Vilalta JM, Colomina-Rodriguez R, Hinarejos-Gomez P, Garcia-Forcada I, Seral Garcia B (2006) Navigation in total knee arthroplasty. A multicenter study. Int Orthop 30:536–540PubMedCrossRef Macule-Beneyto F, Hernandez-Vaquero D, Segur-Vilalta JM, Colomina-Rodriguez R, Hinarejos-Gomez P, Garcia-Forcada I, Seral Garcia B (2006) Navigation in total knee arthroplasty. A multicenter study. Int Orthop 30:536–540PubMedCrossRef
39.
Zurück zum Zitat Tingart M, Luring C, Bathis H, Beckmann J, Grifka J, Perlick L (2008) Computer-assisted total knee arthroplasty versus the conventional technique: how precise is navigation in clinical routine? Knee Surg Sports Traumatol Arthrosc 16:44–50PubMedCrossRef Tingart M, Luring C, Bathis H, Beckmann J, Grifka J, Perlick L (2008) Computer-assisted total knee arthroplasty versus the conventional technique: how precise is navigation in clinical routine? Knee Surg Sports Traumatol Arthrosc 16:44–50PubMedCrossRef
40.
Zurück zum Zitat Rosenberger RE, Hoser C, Quirbach S, Attal R, Hennerbichler A, Fink C (2008) Improved accuracy of component alignment with the implementation of image-free navigation in total knee arthroplasty. Knee Surg Sports Traumatol Arthrosc 16:249–257PubMedCrossRef Rosenberger RE, Hoser C, Quirbach S, Attal R, Hennerbichler A, Fink C (2008) Improved accuracy of component alignment with the implementation of image-free navigation in total knee arthroplasty. Knee Surg Sports Traumatol Arthrosc 16:249–257PubMedCrossRef
41.
Zurück zum Zitat Jenny JY (2008) The current status of computer-assisted high tibial osteotomy, unicompartmental knee replacement, and revision total knee replacement. Instr Course Lect 57:721–726PubMed Jenny JY (2008) The current status of computer-assisted high tibial osteotomy, unicompartmental knee replacement, and revision total knee replacement. Instr Course Lect 57:721–726PubMed
42.
Zurück zum Zitat Graydon AJ, Malak S, Anderson IA, Pitto RP (2009) Evaluation of accuracy of an electromagnetic computer-assisted navigation system in total knee arthroplasty. Int Orthop 33:975–979PubMedCrossRef Graydon AJ, Malak S, Anderson IA, Pitto RP (2009) Evaluation of accuracy of an electromagnetic computer-assisted navigation system in total knee arthroplasty. Int Orthop 33:975–979PubMedCrossRef
43.
Zurück zum Zitat Seon JK, Park SJ, Lee KB, Li G, Kozanek M, Song EK (2009) Functional comparison of total knee arthroplasty performed with and without a navigation system. Int Orthop 33:987–990PubMedCrossRef Seon JK, Park SJ, Lee KB, Li G, Kozanek M, Song EK (2009) Functional comparison of total knee arthroplasty performed with and without a navigation system. Int Orthop 33:987–990PubMedCrossRef
44.
Zurück zum Zitat Mason JB, Fehring TK, Estok R, Banel D, Fahrbach K (2007) Meta-analysis of alignment outcomes in computer-assisted total knee arthroplasty surgery. J Arthroplasty 22:1097–1106PubMedCrossRef Mason JB, Fehring TK, Estok R, Banel D, Fahrbach K (2007) Meta-analysis of alignment outcomes in computer-assisted total knee arthroplasty surgery. J Arthroplasty 22:1097–1106PubMedCrossRef
45.
Zurück zum Zitat Bauwens K, Matthes G, Wich M, Gebhard F, Hanson B, Ekkernkamp A, Stengel D (2007) Navigated total knee replacement. A meta-analysis. J Bone Joint Surg Am 89:261–269PubMedCrossRef Bauwens K, Matthes G, Wich M, Gebhard F, Hanson B, Ekkernkamp A, Stengel D (2007) Navigated total knee replacement. A meta-analysis. J Bone Joint Surg Am 89:261–269PubMedCrossRef
46.
Zurück zum Zitat Rand JA, Coventry MB (1988) Ten-year evaluation of geometric total knee arthroplasty. Clin Orthop Relat Res 232:168–173 Rand JA, Coventry MB (1988) Ten-year evaluation of geometric total knee arthroplasty. Clin Orthop Relat Res 232:168–173
47.
Zurück zum Zitat Spencer JM, Chauhan SK, Sloan K, Taylor A, Beaver RJ (2007) Computer navigation versus conventional total knee replacement: no difference in functional results at two years. J Bone Joint Surg Br 89:477–480PubMedCrossRef Spencer JM, Chauhan SK, Sloan K, Taylor A, Beaver RJ (2007) Computer navigation versus conventional total knee replacement: no difference in functional results at two years. J Bone Joint Surg Br 89:477–480PubMedCrossRef
48.
Zurück zum Zitat Anderson KC, Buehler KC, Markel DC (2005) Computer assisted navigation in total knee arthroplasty: comparison with conventional methods. J Arthroplasty 20:132–138PubMedCrossRef Anderson KC, Buehler KC, Markel DC (2005) Computer assisted navigation in total knee arthroplasty: comparison with conventional methods. J Arthroplasty 20:132–138PubMedCrossRef
49.
Zurück zum Zitat Bolognesi M, Hofmann A (2005) Computer navigation versus standard instrumentation for TKA: a single-surgeon experience. Clin Orthop Relat Res 440:162–169PubMedCrossRef Bolognesi M, Hofmann A (2005) Computer navigation versus standard instrumentation for TKA: a single-surgeon experience. Clin Orthop Relat Res 440:162–169PubMedCrossRef
Metadaten
Titel
Imageless computer assisted versus conventional total knee replacement. A Bayesian meta-analysis of 23 comparative studies
verfasst von
Yaron S. Brin
Vassilios S. Nikolaou
Lawrence Joseph
David J. Zukor
John Antoniou
Publikationsdatum
01.03.2011
Verlag
Springer-Verlag
Erschienen in
International Orthopaedics / Ausgabe 3/2011
Print ISSN: 0341-2695
Elektronische ISSN: 1432-5195
DOI
https://doi.org/10.1007/s00264-010-1008-6

Weitere Artikel der Ausgabe 3/2011

International Orthopaedics 3/2011 Zur Ausgabe

Arthropedia

Grundlagenwissen der Arthroskopie und Gelenkchirurgie. Erweitert durch Fallbeispiele, Videos und Abbildungen. 
» Jetzt entdecken

Update Orthopädie und Unfallchirurgie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.