Vitamin E diffused, highly crosslinked UHMWPE: a review

verfasst von: Ebru Oral, Orhun K. Muratoglu

Erschienen in: International Orthopaedics | Ausgabe 2/2011

Einloggen, um Zugang zu erhalten

Abstract

Highly crosslinked UHMWPE has become the bearing surface of choice in total hip arthroplasty. First generation crosslinked UHMWPEs, clinically introduced in the 1990s, show significant improvements compared to gamma sterilised, conventional UHMWPE in decreasing wear and osteolysis. These crosslinked UHMWPEs were thermally treated (annealed or melted) after irradiation to improve their oxidation resistance. While annealing resulted in the retention of some oxidation potential, post-irradiation melted UHMWPEs had reduced fatigue strength due to the crystallinity loss during melting. Thus, the stabilisation of radiation crosslinked UHMWPEs by the diffusion of the antioxidant vitamin E was developed to obtain oxidation resistance with improved fatigue strength by avoiding post-irradiation melting. A two-step process was developed to incorporate vitamin E into irradiated UHMWPE by diffusion to obtain a uniform concentration profile. Against accelerated and real-time aging in vitro, this material showed superior oxidation resistance to UHMWPEs with residual free radicals. The fatigue strength was improved compared to irradiated and melted UHMWPEs crosslinked using the same irradiation dose. Several adverse testing schemes simulating impingement showed satisfactory behaviour. Peri-prosthetic tissue reaction to vitamin E was evaluated in rabbits and any effects of vitamin E on device fixation were evaluated in a canine model, both of which showed no detrimental effects of the inclusion of vitamin E in crosslinked UHMWPE. Irradiated, vitamin E-diffused, and gamma sterilised UHMWPEs have been in clinical use in hips since 2007 and in knees since 2008. The clinical outcome of this material will be apparent from the results of prospective, randomised clinical studies.
Literatur
1.
Zurück zum Zitat Al-Malaika S (1993) Autoxidation. Atmospheric oxidation and antioxidants. Scott G. Amsterdam, Elsevier Science Publishers B.V., pp 45–82 Al-Malaika S (1993) Autoxidation. Atmospheric oxidation and antioxidants. Scott G. Amsterdam, Elsevier Science Publishers B.V., pp 45–82
2.
Zurück zum Zitat Al-Malaika S (2004) Perspectives in stabilisation of polyolefins. Adv Polym Sci 169:121–150 Al-Malaika S (2004) Perspectives in stabilisation of polyolefins. Adv Polym Sci 169:121–150
3.
Zurück zum Zitat Assink R, Celina M, Dunbar T, Alam T, Clough R, Gillen K (2000) Analysis of hydroperoxides in solid polyethylene by MAS 13 C NMR and EPR. Macromolecules 33:4023–4029CrossRef Assink R, Celina M, Dunbar T, Alam T, Clough R, Gillen K (2000) Analysis of hydroperoxides in solid polyethylene by MAS 13 C NMR and EPR. Macromolecules 33:4023–4029CrossRef
4.
Zurück zum Zitat ASTM (2008) E647-08 Standard test method for measurement of fatigue crack growth rates. American Society for Testing and Materials, PA, USA ASTM (2008) E647-08 Standard test method for measurement of fatigue crack growth rates. American Society for Testing and Materials, PA, USA
5.
Zurück zum Zitat Baker DA, Bellare A, Pruitt L (2003) The effect of degree of crosslinking on the fatigue crack initiation and propagation resistance of orthopedic-grade polyethylene. J Biomed Mater Res 66A:146–154CrossRef Baker DA, Bellare A, Pruitt L (2003) The effect of degree of crosslinking on the fatigue crack initiation and propagation resistance of orthopedic-grade polyethylene. J Biomed Mater Res 66A:146–154CrossRef
6.
Zurück zum Zitat Birman M, Noble P, Conditt M, Li S, Mathis K (2005) Cracking and impingement in ultra-high molecular weight polyethylene acetabular liners. J Arthroplasty 20(7):87–92CrossRefPubMed Birman M, Noble P, Conditt M, Li S, Mathis K (2005) Cracking and impingement in ultra-high molecular weight polyethylene acetabular liners. J Arthroplasty 20(7):87–92CrossRefPubMed
7.
Zurück zum Zitat Bozic K, Kurtz S, Lau E, Ong K, Vail T, Berry D (2009) The epidemiology of revision total hip arthroplasty in the United States. J Bone Joint Surg 91:128–133CrossRefPubMed Bozic K, Kurtz S, Lau E, Ong K, Vail T, Berry D (2009) The epidemiology of revision total hip arthroplasty in the United States. J Bone Joint Surg 91:128–133CrossRefPubMed
8.
Zurück zum Zitat Bracco P, Brunella V, Zanetti M, Luda MP, Costa L (2007) Stabilisation of ultra-high molecular weight polyethylene with vitamin E. Polym Degrad Stab 92:2155–2162CrossRef Bracco P, Brunella V, Zanetti M, Luda MP, Costa L (2007) Stabilisation of ultra-high molecular weight polyethylene with vitamin E. Polym Degrad Stab 92:2155–2162CrossRef
9.
Zurück zum Zitat Burton G, Ingold K (1981) Autoxidation of biological molecules. 1. The antioxidant activity of vitamin E and related chain-breaking phenolic antioxidants in vitro. J Am Chem Soc 103:6472–6477CrossRef Burton G, Ingold K (1981) Autoxidation of biological molecules. 1. The antioxidant activity of vitamin E and related chain-breaking phenolic antioxidants in vitro. J Am Chem Soc 103:6472–6477CrossRef
10.
Zurück zum Zitat Burton GW, Traber MG (1990) Vitamin E: Antioxidant activity, biokinetics, and bioavailability. Annu Rev Nutr 10:357–382CrossRefPubMed Burton GW, Traber MG (1990) Vitamin E: Antioxidant activity, biokinetics, and bioavailability. Annu Rev Nutr 10:357–382CrossRefPubMed
11.
Zurück zum Zitat Carlsson D, Chmela S, Lacoste J (1990) On the structures and yields of the first peroxyl radicals in g-irradiated polyolefins. Macromolecules 23:4934–4938CrossRef Carlsson D, Chmela S, Lacoste J (1990) On the structures and yields of the first peroxyl radicals in g-irradiated polyolefins. Macromolecules 23:4934–4938CrossRef
12.
Zurück zum Zitat Carlsson D, Dobbin C, Wiles D (1985) Direct observations of macroperoxyl radical propagation and termination by electron spin resonance and infrared spectroscopies. Macromolecules 18:2092–2094CrossRef Carlsson D, Dobbin C, Wiles D (1985) Direct observations of macroperoxyl radical propagation and termination by electron spin resonance and infrared spectroscopies. Macromolecules 18:2092–2094CrossRef
13.
Zurück zum Zitat Carlsson DJ, Brousseau R, Zhang C, Wiles DM (1987) Polyolefin oxidation: quantification of alcohol and hydroperoxide products by nitric oxide reactions. Polym Degrad Stab 17:303–318CrossRef Carlsson DJ, Brousseau R, Zhang C, Wiles DM (1987) Polyolefin oxidation: quantification of alcohol and hydroperoxide products by nitric oxide reactions. Polym Degrad Stab 17:303–318CrossRef
14.
Zurück zum Zitat Collier J, Sutula L, Currier B, John H, Wooding R, Williams I, Farber K, Mayor M (1996) Overview of polyethylene as a bearing material: Comparison of sterilization methods. Clin Orthop 333:76–86PubMed Collier J, Sutula L, Currier B, John H, Wooding R, Williams I, Farber K, Mayor M (1996) Overview of polyethylene as a bearing material: Comparison of sterilization methods. Clin Orthop 333:76–86PubMed
15.
Zurück zum Zitat Costa L, Bracco P, Brach del Prever E (2007) Physicochemical and mechanical properties of UHMWPE: 45 years' experience. Interact Surg 2(3–4):169–173CrossRef Costa L, Bracco P, Brach del Prever E (2007) Physicochemical and mechanical properties of UHMWPE: 45 years' experience. Interact Surg 2(3–4):169–173CrossRef
16.
Zurück zum Zitat Costa L, Luda MP, Trossarelli L (1997) Ultra-high molecular weight polyethylene: I. Mechano-oxidative degradation. Polym Degrad Stab 55:329–338CrossRef Costa L, Luda MP, Trossarelli L (1997) Ultra-high molecular weight polyethylene: I. Mechano-oxidative degradation. Polym Degrad Stab 55:329–338CrossRef
17.
Zurück zum Zitat Costa L, Luda MP, Trossarelli L (1997) Ultra high molecular weight polyethylene-II. Thermal-and photo-oxidation. Polym Degrad Stab 58:41–54CrossRef Costa L, Luda MP, Trossarelli L (1997) Ultra high molecular weight polyethylene-II. Thermal-and photo-oxidation. Polym Degrad Stab 58:41–54CrossRef
18.
Zurück zum Zitat Costa L, Luda MP, Trossarelli L, Brach del Prever EM, Crova M, Gallinaro P (1998) In vivo UHMWPE biodegradation of retrieved prosthesis. Biomaterials 19:1371–1385CrossRefPubMed Costa L, Luda MP, Trossarelli L, Brach del Prever EM, Crova M, Gallinaro P (1998) In vivo UHMWPE biodegradation of retrieved prosthesis. Biomaterials 19:1371–1385CrossRefPubMed
19.
Zurück zum Zitat Costa L, Luda MP, Trossarelli L, Brach del Prever EM, Crova M, Gallinaro P (1998) Oxidation in orthopaedic UHMWPE sterilized by gamma radiation and ethylene oxide. Biomaterials 19:659–668CrossRefPubMed Costa L, Luda MP, Trossarelli L, Brach del Prever EM, Crova M, Gallinaro P (1998) Oxidation in orthopaedic UHMWPE sterilized by gamma radiation and ethylene oxide. Biomaterials 19:659–668CrossRefPubMed
20.
Zurück zum Zitat Cuckler J, Moore K, Lombardi A Jr, McPherson E, Emerson R (2004) Large versus small femoral heads in metal-on-metal total hip arthroplasty. J Arthroplast 19(8 suppl 3):41–44CrossRef Cuckler J, Moore K, Lombardi A Jr, McPherson E, Emerson R (2004) Large versus small femoral heads in metal-on-metal total hip arthroplasty. J Arthroplast 19(8 suppl 3):41–44CrossRef
21.
Zurück zum Zitat Currier BH, Currier JH, Mayor MB, Lyford K, Collier JP, Van Citters DW (2007) Evaluation of oxidation and fatigue damage of retrieved Crossfire polyethylene acetabular cups. J Bone Joint Surg 89A:2023–2029CrossRef Currier BH, Currier JH, Mayor MB, Lyford K, Collier JP, Van Citters DW (2007) Evaluation of oxidation and fatigue damage of retrieved Crossfire polyethylene acetabular cups. J Bone Joint Surg 89A:2023–2029CrossRef
22.
Zurück zum Zitat Digas G, Karrholm J, Thanner J, Herberts P (2007) 5-year experience of highly crosslinked polyethylene in cemented and uncemented sockets: Two randomized studies using radiostereometric analysis. Acta Orthop 78(6):746–754CrossRefPubMed Digas G, Karrholm J, Thanner J, Herberts P (2007) 5-year experience of highly crosslinked polyethylene in cemented and uncemented sockets: Two randomized studies using radiostereometric analysis. Acta Orthop 78(6):746–754CrossRefPubMed
23.
Zurück zum Zitat Dole M (1972) Free radicals in irradiated polyethylene. The radiation chemistry of macromolecules. Academic Press, New York, pp 335–348 Dole M (1972) Free radicals in irradiated polyethylene. The radiation chemistry of macromolecules. Academic Press, New York, pp 335–348
24.
Zurück zum Zitat Esterbauer H, Gebicki J, Puhl H, Jurgens G (1992) The role of lipid peroxidation and antioxidants in oxidative modification of LDL. Free Radic Biol Med 13:341–390CrossRefPubMed Esterbauer H, Gebicki J, Puhl H, Jurgens G (1992) The role of lipid peroxidation and antioxidants in oxidative modification of LDL. Free Radic Biol Med 13:341–390CrossRefPubMed
25.
Zurück zum Zitat FDA DoHaHS (2004) Code of Federal Regulations 184.1890: Direct food substances affirmed as generally recognized as safe-[alpha]-tocopherols. US Food and Drug Administration, Title 21, vol 3 FDA DoHaHS (2004) Code of Federal Regulations 184.1890: Direct food substances affirmed as generally recognized as safe-[alpha]-tocopherols. US Food and Drug Administration, Title 21, vol 3
26.
Zurück zum Zitat Gallo J, Havranek V, Zapletalova J (2010) Risk factors for accelerated polyethylene wear and osteolysis in ABG I total hip arthroplasty. Int Orthop 34:19–26CrossRefPubMed Gallo J, Havranek V, Zapletalova J (2010) Risk factors for accelerated polyethylene wear and osteolysis in ABG I total hip arthroplasty. Int Orthop 34:19–26CrossRefPubMed
27.
Zurück zum Zitat Halley D, Glassman A, Crowninshield R (2004) Recurrent dislocation after revision total hip replacement with a large prosthetic femoral head. J Bone Joint Surg 86A(4):827–830 Halley D, Glassman A, Crowninshield R (2004) Recurrent dislocation after revision total hip replacement with a large prosthetic femoral head. J Bone Joint Surg 86A(4):827–830
28.
Zurück zum Zitat Hodrick J, Severson E, McAlister D, Dahl B, Hofmann A (2008) Highly crosslinked polyethylene is safe fro use in total knee arthroplasty. Clin Orthop Relat Res 466:2806–2812CrossRefPubMed Hodrick J, Severson E, McAlister D, Dahl B, Hofmann A (2008) Highly crosslinked polyethylene is safe fro use in total knee arthroplasty. Clin Orthop Relat Res 466:2806–2812CrossRefPubMed
29.
Zurück zum Zitat Jahan MS, King MC, Haggard WO, Sevo KL, Parr JE (2001) A study of long-lived free radicals in gamma-irradiated medical grade polyethlene. Radiat Phys Chem 62:141–144CrossRef Jahan MS, King MC, Haggard WO, Sevo KL, Parr JE (2001) A study of long-lived free radicals in gamma-irradiated medical grade polyethlene. Radiat Phys Chem 62:141–144CrossRef
30.
Zurück zum Zitat Jarrett B, Cofske J, Rosenberg A, Oral E, Muratoglu O, Malchau H (2010) In vivo biological response to vitamin E and vitamin E-doped polyethylene. J Bone Joint Surg 92(13) (in press) Jarrett B, Cofske J, Rosenberg A, Oral E, Muratoglu O, Malchau H (2010) In vivo biological response to vitamin E and vitamin E-doped polyethylene. J Bone Joint Surg 92(13) (in press)
31.
Zurück zum Zitat Kamal-Eldin A, Appelqvist L (1996) The chemistry and antioxidant properties of tocopherols and tocotrienols. Lipids 31(7):671–701CrossRefPubMed Kamal-Eldin A, Appelqvist L (1996) The chemistry and antioxidant properties of tocopherols and tocotrienols. Lipids 31(7):671–701CrossRefPubMed
32.
Zurück zum Zitat Kashiwabara H, Seguchi T (1992) Radiation induced oxidation of plastics. In Singh A, Silverman J (eds) Radiation processing of polymers. Munich, Carl Hanser Verlag, pp 221–254 Kashiwabara H, Seguchi T (1992) Radiation induced oxidation of plastics. In Singh A, Silverman J (eds) Radiation processing of polymers. Munich, Carl Hanser Verlag, pp 221–254
33.
Zurück zum Zitat Kashiwabara H, Shimada S, Hori Y (1991) Free radicals and crosslinking in irradiated polyethylene. Radiat Phys Chem 37(1):43–46 Kashiwabara H, Shimada S, Hori Y (1991) Free radicals and crosslinking in irradiated polyethylene. Radiat Phys Chem 37(1):43–46
34.
Zurück zum Zitat Kurtz S (ed) (2009) UHMWPE biomaterials handbook. London, Elsevier Kurtz S (ed) (2009) UHMWPE biomaterials handbook. London, Elsevier
35.
Zurück zum Zitat Kurtz S, Austin M, Azzam K, Sharkey P, MacDonald D, Medel F, Hozack W (2010) Mechanical properties, oxidation and clinical performance of retrieved highly crosslinked Crossfire liners after intermediate-term implantation. J Arthroplasty 25(4):614–625CrossRefPubMed Kurtz S, Austin M, Azzam K, Sharkey P, MacDonald D, Medel F, Hozack W (2010) Mechanical properties, oxidation and clinical performance of retrieved highly crosslinked Crossfire liners after intermediate-term implantation. J Arthroplasty 25(4):614–625CrossRefPubMed
36.
Zurück zum Zitat Kurtz S, Dumbleton J, Siskey R, Wang A, Manley M (2008) Trace concentrations of vitamin E protect radiation crosslinked UHMWPE from oxidative degradation. J Biomed Mater Res 90A:549–563CrossRef Kurtz S, Dumbleton J, Siskey R, Wang A, Manley M (2008) Trace concentrations of vitamin E protect radiation crosslinked UHMWPE from oxidative degradation. J Biomed Mater Res 90A:549–563CrossRef
37.
Zurück zum Zitat Kurtz S, Hozack WJ, Marcolongo M, Turner J, Rimnac CM, Edidin A (2003) Degradation of mechanical properties of UHMWPE acetabular liners following long-term implantation. J Arthroplast 18(7 Supp 1):68–78CrossRef Kurtz S, Hozack WJ, Marcolongo M, Turner J, Rimnac CM, Edidin A (2003) Degradation of mechanical properties of UHMWPE acetabular liners following long-term implantation. J Arthroplast 18(7 Supp 1):68–78CrossRef
38.
Zurück zum Zitat Kuzuya M, Kondo S, Sugito M, Yamashiro T (1998) Peroxy radical formation from plasma-induced surface free radicals of polyethylene as studied by electron spin resonance. Macromolecules 31:3230–3234CrossRef Kuzuya M, Kondo S, Sugito M, Yamashiro T (1998) Peroxy radical formation from plasma-induced surface free radicals of polyethylene as studied by electron spin resonance. Macromolecules 31:3230–3234CrossRef
39.
Zurück zum Zitat Lerf R, Zurbrugg D, Delfosse D (2010) Use of vitamin E to protect cross-linked UHMWPE from oxidation. Biomaterials 31:3643–3648CrossRefPubMed Lerf R, Zurbrugg D, Delfosse D (2010) Use of vitamin E to protect cross-linked UHMWPE from oxidation. Biomaterials 31:3643–3648CrossRefPubMed
40.
Zurück zum Zitat Livermore J, Ilstrup D, Morrey B (1990) Effect of femoral head size on wear of the polyethylene acetabular component. J Bone Joint Surg 72-A:518–528 Livermore J, Ilstrup D, Morrey B (1990) Effect of femoral head size on wear of the polyethylene acetabular component. J Bone Joint Surg 72-A:518–528
41.
Zurück zum Zitat Mallegol J, Carlsson D, Deschenes L (2001) Post-gamma irradiation reactions in vitamin E stabilized and unstabilised HDPE. Nucl Instrum Meth Phys Res B 185:283–293CrossRef Mallegol J, Carlsson D, Deschenes L (2001) Post-gamma irradiation reactions in vitamin E stabilized and unstabilised HDPE. Nucl Instrum Meth Phys Res B 185:283–293CrossRef
42.
Zurück zum Zitat Manning DW, Chiang PP, Martell JM, Galante JO, Harris WH (2005) In vivo comparative wear study of traditional and highly cross-linked polyethylene in total hip arthroplasty. J Arthroplasty 20(7):880–886CrossRefPubMed Manning DW, Chiang PP, Martell JM, Galante JO, Harris WH (2005) In vivo comparative wear study of traditional and highly cross-linked polyethylene in total hip arthroplasty. J Arthroplasty 20(7):880–886CrossRefPubMed
43.
Zurück zum Zitat Martell JM, Verner JJ, Incavo SJ (2003) Clinical performance of a highly cross-linked polyethylene at two years in total hip arthroplasty: a randomized prospective trial. J Arthroplasty 18(7 Suppl 1):9 Martell JM, Verner JJ, Incavo SJ (2003) Clinical performance of a highly cross-linked polyethylene at two years in total hip arthroplasty: a randomized prospective trial. J Arthroplasty 18(7 Suppl 1):9
44.
Zurück zum Zitat McKellop H, Shen F-W, Lu B, Campbell P, Salovey R (1999) Development of an extremely wear resistant ultra-high molecular weight polyethylene for total hip replacements. J Orthop Res 17(2):157–167CrossRefPubMed McKellop H, Shen F-W, Lu B, Campbell P, Salovey R (1999) Development of an extremely wear resistant ultra-high molecular weight polyethylene for total hip replacements. J Orthop Res 17(2):157–167CrossRefPubMed
45.
Zurück zum Zitat Mu Z, Tian J, Wu T, Yang J, Pei F (2009) A systematic review of radiological outcomes of highly crosslinked polyethylene versus conventional polyethylene in total hip arthroplasty. Int Orthop 33:599–604CrossRefPubMed Mu Z, Tian J, Wu T, Yang J, Pei F (2009) A systematic review of radiological outcomes of highly crosslinked polyethylene versus conventional polyethylene in total hip arthroplasty. Int Orthop 33:599–604CrossRefPubMed
46.
Zurück zum Zitat Muratoglu OK, Bragdon CR, O'Connor DO, Jasty M, Harris WH (2001) A novel method of crosslinking UHMWPE to improve wear, reduce oxidation and retain mechanical properties. J Arthroplasty 16(2):149–160CrossRefPubMed Muratoglu OK, Bragdon CR, O'Connor DO, Jasty M, Harris WH (2001) A novel method of crosslinking UHMWPE to improve wear, reduce oxidation and retain mechanical properties. J Arthroplasty 16(2):149–160CrossRefPubMed
47.
Zurück zum Zitat Muratoglu OK, Bragdon CR, O'Connor DO, Jasty M, Harris WH, Gul R, McGarry F (1999) Unified wear model for highly crosslinked ultra-high molecular weight polyethylenes (UHMWPE). Biomaterials 20(16):1463–1470CrossRefPubMed Muratoglu OK, Bragdon CR, O'Connor DO, Jasty M, Harris WH, Gul R, McGarry F (1999) Unified wear model for highly crosslinked ultra-high molecular weight polyethylenes (UHMWPE). Biomaterials 20(16):1463–1470CrossRefPubMed
48.
Zurück zum Zitat Muratoglu OK, Bragdon CR, O'Connor DO, Perinchief RS, Estok DM, Jasty M, Harris WH (2001) Larger diameter femoral heads used in conjunction with a highly cross-linked ultra-high molecular weight polyethylene: A new concept. J Arthroplasty 16(8 Suppl):24–30CrossRefPubMed Muratoglu OK, Bragdon CR, O'Connor DO, Perinchief RS, Estok DM, Jasty M, Harris WH (2001) Larger diameter femoral heads used in conjunction with a highly cross-linked ultra-high molecular weight polyethylene: A new concept. J Arthroplasty 16(8 Suppl):24–30CrossRefPubMed
49.
Zurück zum Zitat Muratoglu OK, Merrill EW, Bragdon CR, O'Connor DO, Hoeffel D, Burroughs B, Jasty M, Harris WH (2003) Effect of radiation, heat, and aging on in vitro wear resistance of polyethylene. Clin Orthop Relat Res 417:253–262PubMed Muratoglu OK, Merrill EW, Bragdon CR, O'Connor DO, Hoeffel D, Burroughs B, Jasty M, Harris WH (2003) Effect of radiation, heat, and aging on in vitro wear resistance of polyethylene. Clin Orthop Relat Res 417:253–262PubMed
50.
Zurück zum Zitat Oral E, Christensen S, Malhi A, Wannomae K, Muratoglu O (2006) Wear resistance and mechanical properties of highly crosslinked UHMWPE doped with vitamin E. J Arthroplasty 21(4):580–591CrossRefPubMed Oral E, Christensen S, Malhi A, Wannomae K, Muratoglu O (2006) Wear resistance and mechanical properties of highly crosslinked UHMWPE doped with vitamin E. J Arthroplasty 21(4):580–591CrossRefPubMed
51.
Zurück zum Zitat Oral E, Godleski Beckos C, Malhi A, Muratoglu O (2008) The effects of high dose irradiation on the cross-linking of vitamin E-blended UHMWPE. Biomaterials 29:3557–3560CrossRefPubMed Oral E, Godleski Beckos C, Malhi A, Muratoglu O (2008) The effects of high dose irradiation on the cross-linking of vitamin E-blended UHMWPE. Biomaterials 29:3557–3560CrossRefPubMed
52.
Zurück zum Zitat Oral E, Greenbaum ES, Malhi AS, Harris WH, Muratoglu OK (2005) Characterization of irradiated blends of alpha-tocopherol and UHMWPE. Biomaterials 26(33):6657–6663CrossRefPubMed Oral E, Greenbaum ES, Malhi AS, Harris WH, Muratoglu OK (2005) Characterization of irradiated blends of alpha-tocopherol and UHMWPE. Biomaterials 26(33):6657–6663CrossRefPubMed
53.
Zurück zum Zitat Oral E, Malhi A, Muratoglu O (2006) Mechanisms of decrease in fatigue crack propagation resistance in irradiated and melted UHMWPE. Biomaterials 27:917–925CrossRefPubMed Oral E, Malhi A, Muratoglu O (2006) Mechanisms of decrease in fatigue crack propagation resistance in irradiated and melted UHMWPE. Biomaterials 27:917–925CrossRefPubMed
54.
Zurück zum Zitat Oral E, Rowell S, Muratoglu O (2006) The effect of alpha-tocopherol on the oxidation and free radical decay in irradiated UHMWPE. Biomaterials 27:5580–5587CrossRefPubMed Oral E, Rowell S, Muratoglu O (2006) The effect of alpha-tocopherol on the oxidation and free radical decay in irradiated UHMWPE. Biomaterials 27:5580–5587CrossRefPubMed
55.
Zurück zum Zitat Oral E, Wannomae KK, Hawkins NE, Harris WH, Muratoglu OK (2004) a-Tocopherol doped irradiated UHMWPE for high fatigue resistance and low wear. Biomaterials 25(24):5515–5522CrossRefPubMed Oral E, Wannomae KK, Hawkins NE, Harris WH, Muratoglu OK (2004) a-Tocopherol doped irradiated UHMWPE for high fatigue resistance and low wear. Biomaterials 25(24):5515–5522CrossRefPubMed
56.
Zurück zum Zitat Oral E, Wannomae KK, Rowell SL, Muratoglu OK (2007) Diffusion of vitamin E in ultra-high molecular weight polyethylene. Biomaterials 28(35):5225–5237CrossRefPubMed Oral E, Wannomae KK, Rowell SL, Muratoglu OK (2007) Diffusion of vitamin E in ultra-high molecular weight polyethylene. Biomaterials 28(35):5225–5237CrossRefPubMed
57.
Zurück zum Zitat Packer L, Kagan VE (1993) Vitamin E: The antioxidant harvesting center of membranes and lipoproteins. In Packer L, Fuchs J (eds) Vitamin E in health and disease. Marcel Dekker, Inc., New York, pp 179–192 Packer L, Kagan VE (1993) Vitamin E: The antioxidant harvesting center of membranes and lipoproteins. In Packer L, Fuchs J (eds) Vitamin E in health and disease. Marcel Dekker, Inc., New York, pp 179–192
58.
Zurück zum Zitat Parth M, Aust N, Lederer K (2002) Studies on the effect of electron beam radiation on the molecular structure of ultra-high molecular weight polyethylene under the influence of alpha-tocopherol with respect to its application in medical implants. J Mater Sci Mater Med 13(10):917–921CrossRefPubMed Parth M, Aust N, Lederer K (2002) Studies on the effect of electron beam radiation on the molecular structure of ultra-high molecular weight polyethylene under the influence of alpha-tocopherol with respect to its application in medical implants. J Mater Sci Mater Med 13(10):917–921CrossRefPubMed
59.
Zurück zum Zitat Premnath V, Harris W, Jasty M, Merrill E (1996) Gamma sterilization of UHMWPE articular implants: an analysis of the oxidation problem. Ultra high molecular weight poly ethylene. Biomaterials 17:1741–1753CrossRefPubMed Premnath V, Harris W, Jasty M, Merrill E (1996) Gamma sterilization of UHMWPE articular implants: an analysis of the oxidation problem. Ultra high molecular weight poly ethylene. Biomaterials 17:1741–1753CrossRefPubMed
60.
Zurück zum Zitat Rabek J, Ranby B (1973) Photochemical oxidation reactions of synthetic polymers. In Kinell P, Ranby B (eds) ESR applications to polymer research. Almqvist-Wiksell Forlag AB, Stockholm Rabek J, Ranby B (1973) Photochemical oxidation reactions of synthetic polymers. In Kinell P, Ranby B (eds) ESR applications to polymer research. Almqvist-Wiksell Forlag AB, Stockholm
61.
Zurück zum Zitat CJRR (2008) Hip and knee replacements in Canada. 2008 annual report. Canadian Joint Replacement Registry CJRR (2008) Hip and knee replacements in Canada. 2008 annual report. Canadian Joint Replacement Registry
62.
Zurück zum Zitat Reno F, Bracco P, Lombardi F, Boccafoschi F, Costa L, Cannas M (2004) The induction of MMP-9 release from granulocytes by vitamin E in UHMWPE. Biomaterials 25(6):1001CrossRef Reno F, Bracco P, Lombardi F, Boccafoschi F, Costa L, Cannas M (2004) The induction of MMP-9 release from granulocytes by vitamin E in UHMWPE. Biomaterials 25(6):1001CrossRef
63.
Zurück zum Zitat Ries M, Pruitt L (2005) Effect of crosslinking on the microstructure and mechanical properties of ultra-high molecular weight polyethylene. Clin Orthop Relat Res 440:149–156CrossRefPubMed Ries M, Pruitt L (2005) Effect of crosslinking on the microstructure and mechanical properties of ultra-high molecular weight polyethylene. Clin Orthop Relat Res 440:149–156CrossRefPubMed
64.
Zurück zum Zitat Rohrl S, Li M, Nilsson K, Nivbrant B (2007) Very low wear of non-remelted highly crosslinked polyethylene cups: An RSA study lasting up to 6 years. Acta Orthop 78(6):739–745CrossRefPubMed Rohrl S, Li M, Nilsson K, Nivbrant B (2007) Very low wear of non-remelted highly crosslinked polyethylene cups: An RSA study lasting up to 6 years. Acta Orthop 78(6):739–745CrossRefPubMed
65.
Zurück zum Zitat Rowell S, Oral E, Muratoglu O (2010) Comparison of the oxidative stability of vitamin E-stabilized UHMWPE by blending and diffusion. J Orthop Res (in press) Rowell S, Oral E, Muratoglu O (2010) Comparison of the oxidative stability of vitamin E-stabilized UHMWPE by blending and diffusion. J Orthop Res (in press)
66.
Zurück zum Zitat Scott G (1993) Antioxidants: Chain breaking mechanisms. In Scott G (ed) Atmospheric oxidation and antioxidants. Elsevier Science Publishers B.V., pp 121–160 Scott G (1993) Antioxidants: Chain breaking mechanisms. In Scott G (ed) Atmospheric oxidation and antioxidants. Elsevier Science Publishers B.V., pp 121–160
67.
Zurück zum Zitat Sheppard AJ, Pennington JA, Weihrauch JL (1993) Analysis and distribution of vitamin E in vegetable oils and foods. In Packer L, Fuchs J (eds) Vitamin E in health and disease. Marcel Dekker, Inc., New York, pp 9–31 Sheppard AJ, Pennington JA, Weihrauch JL (1993) Analysis and distribution of vitamin E in vegetable oils and foods. In Packer L, Fuchs J (eds) Vitamin E in health and disease. Marcel Dekker, Inc., New York, pp 9–31
68.
Zurück zum Zitat Sochart DH (1999) Relationship of acetabular wear to osteolysis and loosening in total hip arthroplasty. Clin Orthop Relat Res 363:135–150CrossRefPubMed Sochart DH (1999) Relationship of acetabular wear to osteolysis and loosening in total hip arthroplasty. Clin Orthop Relat Res 363:135–150CrossRefPubMed
69.
Zurück zum Zitat Stea S, Antonietti B, Baruffaldi F, Visentin M, Bordini B, Sudanese A, Toni A (2006) Behavior of Hylamer polyethylene in hip arthroplasty: comparison of two gamma sterilization techniques. Int Orthop 30(1):35–38CrossRefPubMed Stea S, Antonietti B, Baruffaldi F, Visentin M, Bordini B, Sudanese A, Toni A (2006) Behavior of Hylamer polyethylene in hip arthroplasty: comparison of two gamma sterilization techniques. Int Orthop 30(1):35–38CrossRefPubMed
70.
Zurück zum Zitat Tower SS, Currier JH, Currier BH, Lyford KA, Van Citters DW, Mayor MB (2007) Rim cracking of the cross-linked longevity polyethylene acetabular liner after total hip arthroplasty. J Bone Joint Surg Am 89(10):2212–2217CrossRefPubMed Tower SS, Currier JH, Currier BH, Lyford KA, Van Citters DW, Mayor MB (2007) Rim cracking of the cross-linked longevity polyethylene acetabular liner after total hip arthroplasty. J Bone Joint Surg Am 89(10):2212–2217CrossRefPubMed
71.
Zurück zum Zitat Tudos F, Iring M (1988) Polyolefine oxidation. Acta Polym 39(1/2):19–26CrossRef Tudos F, Iring M (1988) Polyolefine oxidation. Acta Polym 39(1/2):19–26CrossRef
72.
Zurück zum Zitat Wannomae K, Bhattacharyya S, Freiberg A, Estok D, Harris W, Muratoglu O (2006) In vivo oxidation of retrieved crosslinked UHMWPE acetabular components with residual free radicals. J Arthroplasty 21(7):1005–1011CrossRefPubMed Wannomae K, Bhattacharyya S, Freiberg A, Estok D, Harris W, Muratoglu O (2006) In vivo oxidation of retrieved crosslinked UHMWPE acetabular components with residual free radicals. J Arthroplasty 21(7):1005–1011CrossRefPubMed
73.
Zurück zum Zitat Wolf C, Lederer K, Muller U (2002) Tests of biocompatibility of a-tocopherol with respect to the use as a stabilizer in ultrahigh molecular weight polyethylene for articulating surfaces in joint endoprostheses. J Mater Sci Mater Med 13:701–703CrossRefPubMed Wolf C, Lederer K, Muller U (2002) Tests of biocompatibility of a-tocopherol with respect to the use as a stabilizer in ultrahigh molecular weight polyethylene for articulating surfaces in joint endoprostheses. J Mater Sci Mater Med 13:701–703CrossRefPubMed
74.
Zurück zum Zitat Wolf C, Maninger J, Lederer K, Fruhwirth-Smounig H, Gamse T, Marr R (2006) Stabilisation of crosslinked ultra-high molecular weight polyethylene (UHMW-PE)-acetabular components with alpha-tocopherol. J Mater Sci Mater Med 17:1323–1331CrossRefPubMed Wolf C, Maninger J, Lederer K, Fruhwirth-Smounig H, Gamse T, Marr R (2006) Stabilisation of crosslinked ultra-high molecular weight polyethylene (UHMW-PE)-acetabular components with alpha-tocopherol. J Mater Sci Mater Med 17:1323–1331CrossRefPubMed
75.
Zurück zum Zitat Yamamoto K, Yamaguchi M, Tani M, Hangyo M, Teramura S, Isu T, Tomita N (2004) Degradation diagnosis of UHMWPE with terahertz-time-domain spectroscopy. Appl Phys Lett 85(22):5194–5196CrossRef Yamamoto K, Yamaguchi M, Tani M, Hangyo M, Teramura S, Isu T, Tomita N (2004) Degradation diagnosis of UHMWPE with terahertz-time-domain spectroscopy. Appl Phys Lett 85(22):5194–5196CrossRef
Metadaten
Titel
Vitamin E diffused, highly crosslinked UHMWPE: a review
verfasst von
Ebru Oral
Orhun K. Muratoglu
Publikationsdatum
01.02.2011
Verlag
Springer-Verlag
Erschienen in
International Orthopaedics / Ausgabe 2/2011
Print ISSN: 0341-2695
Elektronische ISSN: 1432-5195
DOI
https://doi.org/10.1007/s00264-010-1161-y

Weitere Artikel der Ausgabe 2/2011

International Orthopaedics 2/2011 Zur Ausgabe

Arthropedia

Grundlagenwissen der Arthroskopie und Gelenkchirurgie. Erweitert durch Fallbeispiele, Videos und Abbildungen. 
» Jetzt entdecken

Update Orthopädie und Unfallchirurgie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.