Abstract

Purpose

The aim of this study was to compare the initial biomechanical characteristics of the angle-stable locking system for intramedullary nails using the new biodegradable sleeve with conventional locking in the treatment of unstable distal tibial fractures.

Methods

Eight pairs of fresh, frozen porcine tibiae were used for this study. The expert tibial nail (Synthes) was equipped with either conventional locking screws (CL) or the angle-stable locking system (AS). This system consists of a special ASLS screw with a biodegradable sleeve. For this investigation distal tibias (5.5 cm) were used and the nails were locked with three screws in both groups. Biomechanical testing included non-destructive torsional and axial loading.

Results

The AS group showed a significantly higher torsional stiffness (70%) compared to the CL group. The range of motion was 0.5 times smaller for the AS constructs. The neutral zone was eight times higher in the CL group (p < 0.001). In axial loading the AS group also showed a 10% higher axial stiffness and a 12% lower range of motion (p < 0.001).

Conclusion

The angle-stable locking system (ASLS) using a special screw and sleeve locking for intramedullary nails provides a significantly higher primary stability. The differences determined in this study may have clinical relevance particularly for torsional loads. For the new biodegradable angle-stable sleeve we found a comparable stability to the PEEK-based sleeve system. This system has the potential to decrease complications such as secondary loss of reduction and mal-/non-union.
Literatur
1.
Zurück zum Zitat Bedi A, Le TT, Karunakar MA (2006) Surgical treatment of nonarticular distal tibia fractures. J Am Acad Orthop Surg 14(7):406–416PubMed Bedi A, Le TT, Karunakar MA (2006) Surgical treatment of nonarticular distal tibia fractures. J Am Acad Orthop Surg 14(7):406–416PubMed
2.
Zurück zum Zitat Im GI, Tae SK (2005) Distal metaphyseal fractures of tibia: a prospective randomized trial of closed reduction and intramedullary nail versus open reduction and plate and screws fixation. J Trauma 59(5):1219–1223, discussion 1223PubMedCrossRef Im GI, Tae SK (2005) Distal metaphyseal fractures of tibia: a prospective randomized trial of closed reduction and intramedullary nail versus open reduction and plate and screws fixation. J Trauma 59(5):1219–1223, discussion 1223PubMedCrossRef
3.
Zurück zum Zitat Mohammed A, Saravanan R, Zammit J, King R (2008) Intramedullary tibial nailing in distal third tibial fractures: distal locking screws and fracture non-union. Int Orthop 32(4):547–549PubMedCrossRef Mohammed A, Saravanan R, Zammit J, King R (2008) Intramedullary tibial nailing in distal third tibial fractures: distal locking screws and fracture non-union. Int Orthop 32(4):547–549PubMedCrossRef
4.
Zurück zum Zitat Tyllianakis M, Megas P, Giannikas D, Lambiris E (2000) Interlocking intramedullary nailing in distal tibial fractures. Orthopedics 23(8):805–808PubMed Tyllianakis M, Megas P, Giannikas D, Lambiris E (2000) Interlocking intramedullary nailing in distal tibial fractures. Orthopedics 23(8):805–808PubMed
5.
Zurück zum Zitat Janssen KW, Biert J, van Kampen A (2007) Treatment of distal tibial fractures: plate versus nail: a retrospective outcome analysis of matched pairs of patients. Int Orthop 31(5):709–714PubMedCrossRef Janssen KW, Biert J, van Kampen A (2007) Treatment of distal tibial fractures: plate versus nail: a retrospective outcome analysis of matched pairs of patients. Int Orthop 31(5):709–714PubMedCrossRef
6.
Zurück zum Zitat Vallier HA, Le TT, Bedi A (2008) Radiographic and clinical comparisons of distal tibia shaft fractures (4 to 11 cm proximal to the plafond): plating versus intramedullary nailing. J Orthop Trauma 22(5):307–311PubMedCrossRef Vallier HA, Le TT, Bedi A (2008) Radiographic and clinical comparisons of distal tibia shaft fractures (4 to 11 cm proximal to the plafond): plating versus intramedullary nailing. J Orthop Trauma 22(5):307–311PubMedCrossRef
7.
Zurück zum Zitat Kuhn S, Hansen M, Rommens PM (2008) Extending the indications of intramedullary nailing with the Expert Tibial Nail. Acta Chir Orthop Traumatol Cech 75(2):77–87PubMed Kuhn S, Hansen M, Rommens PM (2008) Extending the indications of intramedullary nailing with the Expert Tibial Nail. Acta Chir Orthop Traumatol Cech 75(2):77–87PubMed
8.
Zurück zum Zitat Duda GN, Mandruzzato F, Heller M, Schutz M, Claes L, Haas NP (2003) Mechanical borderline indications in the treatment of unreamed tibial nailing. Unfallchirurg 106(8):683–689PubMedCrossRef Duda GN, Mandruzzato F, Heller M, Schutz M, Claes L, Haas NP (2003) Mechanical borderline indications in the treatment of unreamed tibial nailing. Unfallchirurg 106(8):683–689PubMedCrossRef
9.
Zurück zum Zitat Gueorguiev B, Wahnert D, Albrecht D, Ockert B, Windolf M, Schwieger K (2010) Effect on dynamic mechanical stability and interfragmentary movement of angle-stable locking of intramedullary nails in unstable distal tibia fractures: a biomechanical study. J Trauma 70(2):358–365 Gueorguiev B, Wahnert D, Albrecht D, Ockert B, Windolf M, Schwieger K (2010) Effect on dynamic mechanical stability and interfragmentary movement of angle-stable locking of intramedullary nails in unstable distal tibia fractures: a biomechanical study. J Trauma 70(2):358–365
10.
Zurück zum Zitat Horn J, Linke B, JHöntzsch D, Gueorguiev B, Schwieger K (2009) Angle stable interlocking screws improve construct stability of intramedullary nailing of distal tibia fractures: a biomechanical study. Injury 40(7):767–771PubMedCrossRef Horn J, Linke B, JHöntzsch D, Gueorguiev B, Schwieger K (2009) Angle stable interlocking screws improve construct stability of intramedullary nailing of distal tibia fractures: a biomechanical study. Injury 40(7):767–771PubMedCrossRef
11.
Zurück zum Zitat Gueorguiev B, Ockert B, Schwieger K, Wahnert D, Lawson-Smith M, Windolf M, Stoffel K (2011) Angular stability potentially permits fewer locking screws compared with conventional locking in intramedullary nailed distal tibia fractures: a biomechanical study. J Orthop Trauma 25(6):340–346PubMedCrossRef Gueorguiev B, Ockert B, Schwieger K, Wahnert D, Lawson-Smith M, Windolf M, Stoffel K (2011) Angular stability potentially permits fewer locking screws compared with conventional locking in intramedullary nailed distal tibia fractures: a biomechanical study. J Orthop Trauma 25(6):340–346PubMedCrossRef
12.
Zurück zum Zitat Wilke HJ, Wenger K, Claes L (1998) Testing criteria for spinal implants: recommendations for the standardization of in vitro stability testing of spinal implants. Eur Spine J 7(2):148–154PubMedCrossRef Wilke HJ, Wenger K, Claes L (1998) Testing criteria for spinal implants: recommendations for the standardization of in vitro stability testing of spinal implants. Eur Spine J 7(2):148–154PubMedCrossRef
13.
Zurück zum Zitat Kahn KM, Beals RK (2002) Malrotation after locked intramedullary tibial nailing: three case reports and review of the literature. J Trauma 53(3):549–552PubMedCrossRef Kahn KM, Beals RK (2002) Malrotation after locked intramedullary tibial nailing: three case reports and review of the literature. J Trauma 53(3):549–552PubMedCrossRef
14.
Zurück zum Zitat Zelle BA, Bhandari M, Espiritu M, Koval KJ, Zlowodzki M (2006) Treatment of distal tibia fractures without articular involvement: a systematic review of 1125 fractures. J Orthop Trauma 20(1):76–79PubMedCrossRef Zelle BA, Bhandari M, Espiritu M, Koval KJ, Zlowodzki M (2006) Treatment of distal tibia fractures without articular involvement: a systematic review of 1125 fractures. J Orthop Trauma 20(1):76–79PubMedCrossRef
15.
Zurück zum Zitat Schüller M, Weninger P, Tschegg E, Jamek M, Redl H, Stanzl-Tschegg S (2009) Micromotion at the fracture site after tibial nailing with four unreamed small-diameter nails—a biomechanical study using a distal tibia fracture model. J Trauma 66(5):1391–1397PubMedCrossRef Schüller M, Weninger P, Tschegg E, Jamek M, Redl H, Stanzl-Tschegg S (2009) Micromotion at the fracture site after tibial nailing with four unreamed small-diameter nails—a biomechanical study using a distal tibia fracture model. J Trauma 66(5):1391–1397PubMedCrossRef
16.
Zurück zum Zitat Epari DR, Kassi JP, Schell H, Duda GN (2007) Timely fracture-healing requires optimization of axial fixation stability. J Bone Joint Surg Am 89(7):1575–1585PubMedCrossRef Epari DR, Kassi JP, Schell H, Duda GN (2007) Timely fracture-healing requires optimization of axial fixation stability. J Bone Joint Surg Am 89(7):1575–1585PubMedCrossRef
17.
Zurück zum Zitat Kaspar K, Schell H, Seebeck P, Thompson MS, Schutz M, Haas NP, Duda GN (2005) Angle stable locking reduces interfragmentary movements and promotes healing after unreamed nailing. Study of a displaced osteotomy model in sheep tibiae. J Bone Joint Surg Am 87(9):2028–2037PubMedCrossRef Kaspar K, Schell H, Seebeck P, Thompson MS, Schutz M, Haas NP, Duda GN (2005) Angle stable locking reduces interfragmentary movements and promotes healing after unreamed nailing. Study of a displaced osteotomy model in sheep tibiae. J Bone Joint Surg Am 87(9):2028–2037PubMedCrossRef
18.
19.
Zurück zum Zitat Lenschow S, Schliemann B, Dressler K, Zampogna B, Vasta S, Raschke M, Zantop T (2011) Structural properties of a new fixation strategy in double bundle ACL reconstruction: the MiniShim. Arch Orthop Trauma Surg 131(8):1159–1165. doi:10.1007/s00402-011-1331-4 Lenschow S, Schliemann B, Dressler K, Zampogna B, Vasta S, Raschke M, Zantop T (2011) Structural properties of a new fixation strategy in double bundle ACL reconstruction: the MiniShim. Arch Orthop Trauma Surg 131(8):1159–1165. doi:10.​1007/​s00402-011-1331-4
21.
Zurück zum Zitat Kocis J, Navrat T, Florian Z, Wendsche P (2010) Biomechanical testing of spinal segment fixed by thoracolumbar spine locking plate on the swine lumbar spine. Biomed Pap 154(4):345–354 Kocis J, Navrat T, Florian Z, Wendsche P (2010) Biomechanical testing of spinal segment fixed by thoracolumbar spine locking plate on the swine lumbar spine. Biomed Pap 154(4):345–354
23.
Zurück zum Zitat Fuss FK (1991) Anatomy and function of the cruciate ligaments of the domestic pig (Sus scrofa domestica): a comparison with human cruciates. J Anat 178:11–20PubMed Fuss FK (1991) Anatomy and function of the cruciate ligaments of the domestic pig (Sus scrofa domestica): a comparison with human cruciates. J Anat 178:11–20PubMed
24.
Zurück zum Zitat Mariani PP, Margheritini F, Bellelli A (2005) Bone mineral density of the proximal metaphysis of tibia: clinical relevance in posterior cruciate ligament reconstruction. Knee Surg Sports Traumatol Arthrosc 13(4):263–267. doi:10.1007/s00167-004-0564-y PubMedCrossRef Mariani PP, Margheritini F, Bellelli A (2005) Bone mineral density of the proximal metaphysis of tibia: clinical relevance in posterior cruciate ligament reconstruction. Knee Surg Sports Traumatol Arthrosc 13(4):263–267. doi:10.​1007/​s00167-004-0564-y PubMedCrossRef
Metadaten
Titel
The primary stability of angle-stable versus conventional locked intramedullary nails
verfasst von
Dirk Wähnert
Yves Stolarczyk
Konrad L. Hoffmeier
Michael J. Raschke
Gunther O. Hofmann
Thomas Mückley
Publikationsdatum
01.05.2012
Verlag
Springer-Verlag
Erschienen in
International Orthopaedics / Ausgabe 5/2012
Print ISSN: 0341-2695
Elektronische ISSN: 1432-5195
DOI
https://doi.org/10.1007/s00264-011-1420-6

Weitere Artikel der Ausgabe 5/2012

International Orthopaedics 5/2012 Zur Ausgabe

Arthropedia

Grundlagenwissen der Arthroskopie und Gelenkchirurgie. Erweitert durch Fallbeispiele, Videos und Abbildungen. 
» Jetzt entdecken

Update Orthopädie und Unfallchirurgie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.