Skip to main content
Erschienen in: International Orthopaedics 12/2012

01.12.2012 | Original Paper

What is the risk of stress risers for interprosthetic fractures of the femur? A biomechanical analysis

verfasst von: Wolfgang Lehmann, Martin Rupprecht, Jacob Nuechtern, Daniel Melzner, Kai Sellenschloh, Jan Kolb, Florian Fensky, Michael Hoffmann, Klaus Püschel, Michael Morlock, Johannes M. Rueger

Erschienen in: International Orthopaedics | Ausgabe 12/2012

Einloggen, um Zugang zu erhalten

Abstract

Purpose

Due to increasing life expectancy we see a rising number of joint replacements. Along with the proximal prosthesis in the femur, more and more people have a second implant on the distal ipsilateral side. This might be a retrograde nail or a locking plate to treat distal femur fractures or a constrained knee prosthesis in the case of severe arthrosis. All these constructs can lead to fractures between the implants. The goal of this study was to evaluate the risk of stress risers for interprosthetic fractures of the femur.

Methods

Thirty human cadaveric femurs were divided into five groups: (1) femurs with a prosthesis on the proximal side only, (2) hip prosthesis on the proximal end and a distal femur nail, (3) femurs with both a hip prosthesis and a constrained knee prosthesis, (4) femurs with a hip prosthesis on the proximal side and a 4.5-mm distal femur locking plate; the locking plate was 230 mm in length, with ten holes in the shaft, and (5) femurs with a proximal hip prosthesis and a 4.5-mm distal femur locking plate; the locking plate was 342 mm in length, with 16 holes in the shaft.

Results

Femurs with a hip prosthesis and knee prosthesis showed significantly higher required fracture force compared to femurs with a hip prosthesis and a distal retrograde nail. Femurs with a distal locking plate of either length showed a higher required fracture force than those with the retrograde nail.

Conclusions

The highest risk for a fracture in the femur with an existing hip prosthesis comes with a retrograde nail. A distal locking plate for the treatment of supracondylar fractures leads to a higher required fracture force. The implantation of a constrained knee prosthesis that is not loosened on the ipsilateral side does not increase the risk for a fracture.
Literatur
1.
Zurück zum Zitat Appleton P, Moran M, Houshian S, Robinson CM (2006) Distal femoral fractures treated by hinged total knee replacement in elderly patients. J Bone Joint Surg Br 88:1065–1070PubMedCrossRef Appleton P, Moran M, Houshian S, Robinson CM (2006) Distal femoral fractures treated by hinged total knee replacement in elderly patients. J Bone Joint Surg Br 88:1065–1070PubMedCrossRef
2.
Zurück zum Zitat Fink B, Fuerst M, Singer J (2005) Periprosthetic fractures of the femur associated with hip arthroplasty. Arch Orthop Trauma Surg 125:433–442PubMedCrossRef Fink B, Fuerst M, Singer J (2005) Periprosthetic fractures of the femur associated with hip arthroplasty. Arch Orthop Trauma Surg 125:433–442PubMedCrossRef
3.
Zurück zum Zitat Hou Z, Moore B, Bowen TR, Irgit K, Matzko ME, Strohecker KA, Smith WR (2011) Treatment of interprosthetic fractures of the femur. J Trauma 71:1715–1719PubMedCrossRef Hou Z, Moore B, Bowen TR, Irgit K, Matzko ME, Strohecker KA, Smith WR (2011) Treatment of interprosthetic fractures of the femur. J Trauma 71:1715–1719PubMedCrossRef
4.
Zurück zum Zitat Iesaka K, Kummer FJ, Di Cesare PE (2005) Stress risers between two ipsilateral intramedullary stems: a finite-element and biomechanical analysis. J Arthroplasty 20:386–391PubMedCrossRef Iesaka K, Kummer FJ, Di Cesare PE (2005) Stress risers between two ipsilateral intramedullary stems: a finite-element and biomechanical analysis. J Arthroplasty 20:386–391PubMedCrossRef
5.
Zurück zum Zitat Kenny P, Rice J, Quinlan W (1998) Interprosthetic fracture of the femoral shaft. J Arthroplasty 13:361–364PubMedCrossRef Kenny P, Rice J, Quinlan W (1998) Interprosthetic fracture of the femoral shaft. J Arthroplasty 13:361–364PubMedCrossRef
6.
Zurück zum Zitat Lachiewicz PF, Soileau ES (2011) Results of a second-generation constrained condylar prosthesis in primary total knee arthroplasty. J Arthroplasty 26:1228–1231PubMedCrossRef Lachiewicz PF, Soileau ES (2011) Results of a second-generation constrained condylar prosthesis in primary total knee arthroplasty. J Arthroplasty 26:1228–1231PubMedCrossRef
7.
Zurück zum Zitat Lehmann W, Rupprecht M, Hellmers N, Sellenschloh K, Briem D, Puschel K, Amling M, Morlock M, Rueger JM (2010) Biomechanical evaluation of peri- and interprosthetic fractures of the femur. J Trauma 68:1459–1463PubMedCrossRef Lehmann W, Rupprecht M, Hellmers N, Sellenschloh K, Briem D, Puschel K, Amling M, Morlock M, Rueger JM (2010) Biomechanical evaluation of peri- and interprosthetic fractures of the femur. J Trauma 68:1459–1463PubMedCrossRef
8.
Zurück zum Zitat Lenz M, Windolf M, Muckley T, Hofmann GO, Wagner M, Richards RG, Schwieger K, Gueorguiev B (2012) The locking attachment plate for proximal fixation of periprosthetic femur fractures-a biomechanical comparison of two techniques. Int Orthop 36:1915–1921PubMedCrossRef Lenz M, Windolf M, Muckley T, Hofmann GO, Wagner M, Richards RG, Schwieger K, Gueorguiev B (2012) The locking attachment plate for proximal fixation of periprosthetic femur fractures-a biomechanical comparison of two techniques. Int Orthop 36:1915–1921PubMedCrossRef
9.
Zurück zum Zitat Mamczak CN, Gardner MJ, Bolhofner B, Borrelli J Jr, Streubel PN, Ricci WM (2010) Interprosthetic femoral fractures. J Orthop Trauma 24:740–744PubMedCrossRef Mamczak CN, Gardner MJ, Bolhofner B, Borrelli J Jr, Streubel PN, Ricci WM (2010) Interprosthetic femoral fractures. J Orthop Trauma 24:740–744PubMedCrossRef
10.
Zurück zum Zitat Mukundan C, Rayan F, Kheir E, Macdonald D (2010) Management of late periprosthetic femur fractures: a retrospective cohort of 72 patients. Int Orthop 34:485–489PubMedCrossRef Mukundan C, Rayan F, Kheir E, Macdonald D (2010) Management of late periprosthetic femur fractures: a retrospective cohort of 72 patients. Int Orthop 34:485–489PubMedCrossRef
11.
Zurück zum Zitat Rupprecht M, Grossterlinden L, Barvencik F, Gebauer M, Briem D, Rueger JM, Lehmann W (2008) Periprosthetic fractures. Long-term results after plate osteosynthesis stabilization. Unfallchirurg 111:812–820PubMedCrossRef Rupprecht M, Grossterlinden L, Barvencik F, Gebauer M, Briem D, Rueger JM, Lehmann W (2008) Periprosthetic fractures. Long-term results after plate osteosynthesis stabilization. Unfallchirurg 111:812–820PubMedCrossRef
12.
Zurück zum Zitat Rupprecht M, Grossterlinden L, Ruecker AH, de Oliveira AN, Sellenschloh K, Nuchtern J, Puschel K, Morlock M, Rueger JM, Lehmann W (2011) A comparative biomechanical analysis of fixation devices for unstable femoral neck fractures: the Intertan versus cannulated screws or a dynamic hip screw. J Trauma 71:625–634PubMedCrossRef Rupprecht M, Grossterlinden L, Ruecker AH, de Oliveira AN, Sellenschloh K, Nuchtern J, Puschel K, Morlock M, Rueger JM, Lehmann W (2011) A comparative biomechanical analysis of fixation devices for unstable femoral neck fractures: the Intertan versus cannulated screws or a dynamic hip screw. J Trauma 71:625–634PubMedCrossRef
13.
Zurück zum Zitat Rupprecht M, Grossterlinden L, Sellenschloh K, Hoffmann M, Puschel K, Morlock M, Rueger JM, Lehmann W (2011) Internal fixation of femoral neck fractures with posterior comminution: a biomechanical comparison of DHS(R) and Intertan nail(R). Int Orthop 35:1695–1701PubMedCrossRef Rupprecht M, Grossterlinden L, Sellenschloh K, Hoffmann M, Puschel K, Morlock M, Rueger JM, Lehmann W (2011) Internal fixation of femoral neck fractures with posterior comminution: a biomechanical comparison of DHS(R) and Intertan nail(R). Int Orthop 35:1695–1701PubMedCrossRef
14.
Zurück zum Zitat Rupprecht M, Sellenschloh K, Grossterlinden L, Puschel K, Morlock M, Amling M, Rueger JM, Lehmann W (2011) Biomechanical evaluation for mechanisms of periprosthetic femoral fractures. J Trauma 70:E62–E66PubMedCrossRef Rupprecht M, Sellenschloh K, Grossterlinden L, Puschel K, Morlock M, Amling M, Rueger JM, Lehmann W (2011) Biomechanical evaluation for mechanisms of periprosthetic femoral fractures. J Trauma 70:E62–E66PubMedCrossRef
Metadaten
Titel
What is the risk of stress risers for interprosthetic fractures of the femur? A biomechanical analysis
verfasst von
Wolfgang Lehmann
Martin Rupprecht
Jacob Nuechtern
Daniel Melzner
Kai Sellenschloh
Jan Kolb
Florian Fensky
Michael Hoffmann
Klaus Püschel
Michael Morlock
Johannes M. Rueger
Publikationsdatum
01.12.2012
Verlag
Springer-Verlag
Erschienen in
International Orthopaedics / Ausgabe 12/2012
Print ISSN: 0341-2695
Elektronische ISSN: 1432-5195
DOI
https://doi.org/10.1007/s00264-012-1697-0

Weitere Artikel der Ausgabe 12/2012

International Orthopaedics 12/2012 Zur Ausgabe

Arthropedia

Grundlagenwissen der Arthroskopie und Gelenkchirurgie. Erweitert durch Fallbeispiele, Videos und Abbildungen. 
» Jetzt entdecken

Update Orthopädie und Unfallchirurgie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.