Skip to main content
Erschienen in: International Orthopaedics 6/2013

01.06.2013 | Original Paper

Evaluation of the accuracy of femoral component orientation by the CT-based fluoro-matched navigation system

verfasst von: Shinya Hayashi, Takayuki Nishiyama, Takaaki Fujishiro, Shingo Hashimoto, Noriyuki Kanzaki, Kotaro Nishida, Ryosuke Kuroda, Masahiro Kurosaka

Erschienen in: International Orthopaedics | Ausgabe 6/2013

Einloggen, um Zugang zu erhalten

Abstract

Purpose

Accurate orientation of acetabular and femoral components are important during THA. However, no study has assessed the use of the CT-based fluoro-matched navigation system during THA. Therefore, we have evaluated the accuracy of stem orientation by CT-based fluoro-matched navigation.

Methods

The accuracy of stem orientation by CT-based fluoro-matched navigation was assessed by postoperative CT data. Furthermore, we compared the postoperative stem orientation with the intraoperative registration errors.

Results

The average antetorsion error of the stem (navigation records − postoperative CT) was −0.5° ± 5.2°. The stem valgus error was 0.4° ± 2.7°. The accuracy of the navigation record for the orientation of the stem valgus was dependent on the intraoperative registration errors.

Conclusions

The clinical accuracy of CT-based fluoro-matched navigation is adequate for stem alignment orientation, and the intraoperative verification of registration errors is valuable for checking the accuracy of stem orientation by navigation.
Literatur
1.
Zurück zum Zitat Lewinnek GE, Lewis JL, Tarr R, Compere CL, Zimmerman JR (1978) Dislocations after total hip-replacement arthroplasties. J Bone Joint Surg Am 60(2):217–220PubMed Lewinnek GE, Lewis JL, Tarr R, Compere CL, Zimmerman JR (1978) Dislocations after total hip-replacement arthroplasties. J Bone Joint Surg Am 60(2):217–220PubMed
2.
Zurück zum Zitat Sariali E, Mouttet A, Pasquier G, Durante E, Catone Y (2009) Accuracy of reconstruction of the hip using computerised three-dimensional pre-operative planning and a cementless modular neck. J Bone Joint Surg Br 91(3):333–340PubMed Sariali E, Mouttet A, Pasquier G, Durante E, Catone Y (2009) Accuracy of reconstruction of the hip using computerised three-dimensional pre-operative planning and a cementless modular neck. J Bone Joint Surg Br 91(3):333–340PubMed
3.
Zurück zum Zitat Jerosch J, von Hasselbach C, Filler T, Peuker E, Rahgozar M, Lahmer A (1998) Increasing the quality of preoperative planning and intraoperative application of computer-assisted systems and surgical robots—an experimental study. Chirurg 69(9):973–976PubMedCrossRef Jerosch J, von Hasselbach C, Filler T, Peuker E, Rahgozar M, Lahmer A (1998) Increasing the quality of preoperative planning and intraoperative application of computer-assisted systems and surgical robots—an experimental study. Chirurg 69(9):973–976PubMedCrossRef
4.
Zurück zum Zitat Wines AP, McNicol D (2006) Computed tomography measurement of the accuracy of component version in total hip arthroplasty. J Arthroplasty 21(5):696–701PubMedCrossRef Wines AP, McNicol D (2006) Computed tomography measurement of the accuracy of component version in total hip arthroplasty. J Arthroplasty 21(5):696–701PubMedCrossRef
5.
Zurück zum Zitat Dorr LD, Malik A, Dastane M, Wan Z (2009) Combined anteversion technique for total hip arthroplasty. Clin Orthop Relat Res 467(1):119–127PubMedCrossRef Dorr LD, Malik A, Dastane M, Wan Z (2009) Combined anteversion technique for total hip arthroplasty. Clin Orthop Relat Res 467(1):119–127PubMedCrossRef
6.
Zurück zum Zitat Wixson RL, MacDonald MA (2005) Total hip arthroplasty through a minimal posterior approach using imageless computer-assisted hip navigation. J Arthroplasty 20(7 Suppl 3):51–56PubMedCrossRef Wixson RL, MacDonald MA (2005) Total hip arthroplasty through a minimal posterior approach using imageless computer-assisted hip navigation. J Arthroplasty 20(7 Suppl 3):51–56PubMedCrossRef
7.
Zurück zum Zitat Najarian BC, Kilgore JE, Markel DC (2009) Evaluation of component positioning in primary total hip arthroplasty using an imageless navigation device compared with traditional methods. J Arthroplasty 24(1):15–21PubMedCrossRef Najarian BC, Kilgore JE, Markel DC (2009) Evaluation of component positioning in primary total hip arthroplasty using an imageless navigation device compared with traditional methods. J Arthroplasty 24(1):15–21PubMedCrossRef
8.
Zurück zum Zitat Kitada M, Nakamura N, Iwana D, Kakimoto A, Nishii T, Sugano N (2011) Evaluation of the accuracy of computed tomography-based navigation for femoral stem orientation and leg length discrepancy. J Arthroplasty 26(5):674–679PubMedCrossRef Kitada M, Nakamura N, Iwana D, Kakimoto A, Nishii T, Sugano N (2011) Evaluation of the accuracy of computed tomography-based navigation for femoral stem orientation and leg length discrepancy. J Arthroplasty 26(5):674–679PubMedCrossRef
9.
Zurück zum Zitat Ryan JA, Jamali AA, Bargar WL (2010) Accuracy of computer navigation for acetabular component placement in THA. Clin Orthop Relat Res 468(1):169–177PubMedCrossRef Ryan JA, Jamali AA, Bargar WL (2010) Accuracy of computer navigation for acetabular component placement in THA. Clin Orthop Relat Res 468(1):169–177PubMedCrossRef
10.
Zurück zum Zitat Kalteis T, Handel M, Bathis H, Perlick L, Tingart M, Grifka J (2006) Imageless navigation for insertion of the acetabular component in total hip arthroplasty: is it as accurate as CT-based navigation? J Bone Joint Surg Br 88(2):163–167PubMed Kalteis T, Handel M, Bathis H, Perlick L, Tingart M, Grifka J (2006) Imageless navigation for insertion of the acetabular component in total hip arthroplasty: is it as accurate as CT-based navigation? J Bone Joint Surg Br 88(2):163–167PubMed
11.
Zurück zum Zitat Hohmann E, Bryant A, Tetsworth K (2012) Anterior pelvic soft tissue thickness influences acetabular cup positioning with imageless navigation. J Arthroplasty 27(6):945–952PubMedCrossRef Hohmann E, Bryant A, Tetsworth K (2012) Anterior pelvic soft tissue thickness influences acetabular cup positioning with imageless navigation. J Arthroplasty 27(6):945–952PubMedCrossRef
12.
Zurück zum Zitat Tsukada S, Wakui M (2010) Decreased accuracy of acetabular cup placement for imageless navigation in obese patients. J Orthop Sci 15(6):758–763PubMedCrossRef Tsukada S, Wakui M (2010) Decreased accuracy of acetabular cup placement for imageless navigation in obese patients. J Orthop Sci 15(6):758–763PubMedCrossRef
13.
Zurück zum Zitat Hasart O, Perka C, Christian K, Asbach P, Janz V, Wassilew GI (2010) Influence of body mass index and thickness of soft tissue on accuracy of ultrasound and pointer based registration in navigation of cup in hip arthroplasty. Technol Health Care 18(4–5):341–351PubMed Hasart O, Perka C, Christian K, Asbach P, Janz V, Wassilew GI (2010) Influence of body mass index and thickness of soft tissue on accuracy of ultrasound and pointer based registration in navigation of cup in hip arthroplasty. Technol Health Care 18(4–5):341–351PubMed
14.
Zurück zum Zitat Lee YS, Yoon TR (2008) Error in acetabular socket alignment due to the thick anterior pelvic soft tissues. J Arthroplasty 23(5):699–706PubMedCrossRef Lee YS, Yoon TR (2008) Error in acetabular socket alignment due to the thick anterior pelvic soft tissues. J Arthroplasty 23(5):699–706PubMedCrossRef
15.
Zurück zum Zitat Jerosch J, Peuker E, von Hasselbach C, Lahmer A, Filler T, Witzel U (1999) Computer assisted implantation of the femoral stem in THA—an experimental study. Int Orthop 23(4):224–226PubMedCrossRef Jerosch J, Peuker E, von Hasselbach C, Lahmer A, Filler T, Witzel U (1999) Computer assisted implantation of the femoral stem in THA—an experimental study. Int Orthop 23(4):224–226PubMedCrossRef
16.
Zurück zum Zitat Zheng G, Marx A, Langlotz U, Widmer KH, Buttaro M, Nolte LP (2002) A hybrid CT-free navigation system for total hip arthroplasty. Comput Aided Surg 7(3):129–145PubMedCrossRef Zheng G, Marx A, Langlotz U, Widmer KH, Buttaro M, Nolte LP (2002) A hybrid CT-free navigation system for total hip arthroplasty. Comput Aided Surg 7(3):129–145PubMedCrossRef
Metadaten
Titel
Evaluation of the accuracy of femoral component orientation by the CT-based fluoro-matched navigation system
verfasst von
Shinya Hayashi
Takayuki Nishiyama
Takaaki Fujishiro
Shingo Hashimoto
Noriyuki Kanzaki
Kotaro Nishida
Ryosuke Kuroda
Masahiro Kurosaka
Publikationsdatum
01.06.2013
Verlag
Springer-Verlag
Erschienen in
International Orthopaedics / Ausgabe 6/2013
Print ISSN: 0341-2695
Elektronische ISSN: 1432-5195
DOI
https://doi.org/10.1007/s00264-013-1852-2

Weitere Artikel der Ausgabe 6/2013

International Orthopaedics 6/2013 Zur Ausgabe

Arthropedia

Grundlagenwissen der Arthroskopie und Gelenkchirurgie. Erweitert durch Fallbeispiele, Videos und Abbildungen. 
» Jetzt entdecken

Update Orthopädie und Unfallchirurgie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.