Skip to main content
Erschienen in: International Orthopaedics 8/2014

01.08.2014 | Original Paper

A biomechanical comparison of fixed angle locking compression plate osteosynthesis and cement augmented screw osteosynthesis in the management of intra articular calcaneal fractures

verfasst von: Sascha Rausch, Kajetan Klos, Uwe Wolf, Marc Gras, Paul Simons, Steffen Brodt, Markus Windolf, Boyko Gueorguiev

Erschienen in: International Orthopaedics | Ausgabe 8/2014

Einloggen, um Zugang zu erhalten

Abstract

Purpose

The purpose of this study was to investigate whether cement-augmented screw osteosynthesis results in stability comparable to conventional fixed-angle locking plate osteosynthesis using cadaveric bones to model a Sanders type 2B fracture.

Methods

Seven pairs of fresh frozen human calcanei and the corresponding tali were used. The specimens were assigned pairwise to two study groups in a randomised manner. In order to determine the initial quasi-static stiffness of the bone-implant construct, testing commenced with quasi-static compression ramp loading; subsequently, sinusoidal cyclic compression loading at 2 Hz was performed until construct failure occurred. Initial dynamic stiffness (cycle 1), range of motion (ROM), cycles to failure and load to failure were determined from the machine data during the cyclic test. In addition, at 250-cycle intervals, Böhler’s angle and the critical angle of Gissane were determined on mediolateral X-rays shot with a triggered C-arm; 5° angle flattening was arbitrarily defined as a failure criterion.

Results

Bone mineral density was normally distributed without significant differences between the groups. The augmented screw osteosynthesis resulted in higher stiffness values compared to the fixed-angle locking plate osteosynthesis. The fracture fragment motion in the locking plate group was significantly higher compared to the group with augmented screw osteosynthesis.

Conclusions

The results of this study indicate that in our selected test set-up augmented screw osteosynthesis was significantly superior to the conventional fixed-angle locking plate osteosynthesis with respect to primary stability and ROM during cyclic testing.
Literatur
4.
Zurück zum Zitat Abidi NA, Dhawan S, Gruen GS, Vogt MT, Conti SF (1998) Wound-healing risk factors after open reduction and internal fixation of calcaneal fractures. Foot Ankle Int 19:856–861PubMedCrossRef Abidi NA, Dhawan S, Gruen GS, Vogt MT, Conti SF (1998) Wound-healing risk factors after open reduction and internal fixation of calcaneal fractures. Foot Ankle Int 19:856–861PubMedCrossRef
5.
Zurück zum Zitat Bajammal S, Tornetta P 3rd, Sanders D, Bhandari M (2005) Displaced intra-articular calcaneal fractures. J Orthop Trauma 19:360–364PubMed Bajammal S, Tornetta P 3rd, Sanders D, Bhandari M (2005) Displaced intra-articular calcaneal fractures. J Orthop Trauma 19:360–364PubMed
9.
Zurück zum Zitat Rammelt S, Gavlik JM, Barthel S, Zwipp H (2002) The value of subtalar arthroscopy in the management of intra-articular calcaneus fractures. Foot Ankle Int 23:906–916PubMed Rammelt S, Gavlik JM, Barthel S, Zwipp H (2002) The value of subtalar arthroscopy in the management of intra-articular calcaneus fractures. Foot Ankle Int 23:906–916PubMed
10.
Zurück zum Zitat Andermahr J, Helling HJ, Rehm KE, Koebke Z (1999) The vascularization of the os calcaneum and the clinical consequences. Clin Orthop Relat Res 363:212–218PubMed Andermahr J, Helling HJ, Rehm KE, Koebke Z (1999) The vascularization of the os calcaneum and the clinical consequences. Clin Orthop Relat Res 363:212–218PubMed
11.
Zurück zum Zitat Richter M, Gosling T, Zech S, Allami M, Geerling J, Droste P, Krettek C (2005) A comparison of plates with and without locking screws in a calcaneal fracture model. Foot Ankle Int 26:309–319PubMed Richter M, Gosling T, Zech S, Allami M, Geerling J, Droste P, Krettek C (2005) A comparison of plates with and without locking screws in a calcaneal fracture model. Foot Ankle Int 26:309–319PubMed
12.
Zurück zum Zitat Schildhauer TA, Bauer TW, Josten C, Muhr G (2000) Open reduction and augmentation of internal fixation with an injectable skeletal cement for the treatment of complex calcaneal fractures. J Orthop Trauma 14:309–317PubMedCrossRef Schildhauer TA, Bauer TW, Josten C, Muhr G (2000) Open reduction and augmentation of internal fixation with an injectable skeletal cement for the treatment of complex calcaneal fractures. J Orthop Trauma 14:309–317PubMedCrossRef
13.
Zurück zum Zitat Chen L, Zhang G, Hong J, Lu X, Yuan W (2011) Comparison of percutaneous screw fixation and calcium sulfate cement grafting versus open treatment of displaced intra-articular calcaneal fractures. Foot Ankle Int 32:979–985PubMedCrossRef Chen L, Zhang G, Hong J, Lu X, Yuan W (2011) Comparison of percutaneous screw fixation and calcium sulfate cement grafting versus open treatment of displaced intra-articular calcaneal fractures. Foot Ankle Int 32:979–985PubMedCrossRef
14.
Zurück zum Zitat Brodt S, Gisep A, Schwieger K, Suhm N, Appelt A (2007) Solid body augmentation for comminuted calcaneal fractures: development and biomechanical testing of a hybrid osteosynthesis technique. Unfallchirurg 110:1013–1020. doi:10.1007/s00113-007-1362-z PubMedCrossRef Brodt S, Gisep A, Schwieger K, Suhm N, Appelt A (2007) Solid body augmentation for comminuted calcaneal fractures: development and biomechanical testing of a hybrid osteosynthesis technique. Unfallchirurg 110:1013–1020. doi:10.​1007/​s00113-007-1362-z PubMedCrossRef
15.
Zurück zum Zitat Thordarson DB, Bollinger M (2005) SRS cancellous bone cement augmentation of calcaneal fracture fixation. Foot Ankle Int 26:347–352PubMed Thordarson DB, Bollinger M (2005) SRS cancellous bone cement augmentation of calcaneal fracture fixation. Foot Ankle Int 26:347–352PubMed
16.
Zurück zum Zitat Thordarson DB, Hedman TP, Yetkinler DN, Eskander E, Lawrence TN, Poser RD (1999) Superior compressive strength of a calcaneal fracture construct augmented with remodelable cancellous bone cement. J Bone Joint Surg Am 81:239–246PubMed Thordarson DB, Hedman TP, Yetkinler DN, Eskander E, Lawrence TN, Poser RD (1999) Superior compressive strength of a calcaneal fracture construct augmented with remodelable cancellous bone cement. J Bone Joint Surg Am 81:239–246PubMed
17.
Zurück zum Zitat Gueorguiev B, Ockert B, Schwieger K, Wähnert D, Lawson-Smith M, Windolf M, Stoffel K (2011) Angular stability potentially permits fewer locking screws compared with conventional locking in intramedullary nailed distal tibia fractures: a biomechanical study. J Orthop Trauma 25:340–346. doi:10.1097/BOT.0b013e3182163345 PubMedCrossRef Gueorguiev B, Ockert B, Schwieger K, Wähnert D, Lawson-Smith M, Windolf M, Stoffel K (2011) Angular stability potentially permits fewer locking screws compared with conventional locking in intramedullary nailed distal tibia fractures: a biomechanical study. J Orthop Trauma 25:340–346. doi:10.​1097/​BOT.​0b013e3182163345​ PubMedCrossRef
18.
19.
Zurück zum Zitat Smerek JP, Kadakia A, Belkoff SM, Knight TA, Myerson MS, Jeng CL (2008) Percutaneous screw configuration versus perimeter plating of calcaneus fractures: a cadaver study. Foot Ankle Int 29:931–935. doi:10.3113/FAI.2008.0931 PubMedCrossRef Smerek JP, Kadakia A, Belkoff SM, Knight TA, Myerson MS, Jeng CL (2008) Percutaneous screw configuration versus perimeter plating of calcaneus fractures: a cadaver study. Foot Ankle Int 29:931–935. doi:10.​3113/​FAI.​2008.​0931 PubMedCrossRef
21.
Zurück zum Zitat Zech S, Goesling T, Hankemeier S, Knobloch K, Geerling J, Schultz-Brunn K, Krettek C, Richter M (2006) Differences in the mechanical properties of calcaneal artificial specimens, fresh frozen specimens, and embalmed specimens in experimental testing. Foot Ankle Int 27:1126–1136PubMed Zech S, Goesling T, Hankemeier S, Knobloch K, Geerling J, Schultz-Brunn K, Krettek C, Richter M (2006) Differences in the mechanical properties of calcaneal artificial specimens, fresh frozen specimens, and embalmed specimens in experimental testing. Foot Ankle Int 27:1126–1136PubMed
23.
25.
Zurück zum Zitat Elsner A, Jubel A, Prokop A, Koebke J, Rehm KE, Andermahr J (2005) Augmentation of intraarticular calcaneal fractures with injectable calcium phosphate cement: densitometry, histology, and functional outcome of 18 patients. J Foot Ankle Surg 44:390–395. doi:10.1053/j.jfas.2005.07.003 PubMedCrossRef Elsner A, Jubel A, Prokop A, Koebke J, Rehm KE, Andermahr J (2005) Augmentation of intraarticular calcaneal fractures with injectable calcium phosphate cement: densitometry, histology, and functional outcome of 18 patients. J Foot Ankle Surg 44:390–395. doi:10.​1053/​j.​jfas.​2005.​07.​003 PubMedCrossRef
26.
Zurück zum Zitat Johal HS, Buckley RE, Le IL, Leighton RK (2009) A prospective randomized controlled trial of a bioresorbable calcium phosphate paste (alpha-BSM) in treatment of displaced intra-articular calcaneal fractures. J Trauma 67:875–882. doi:10.1097/TA.0b013e3181ae2d50 PubMedCrossRef Johal HS, Buckley RE, Le IL, Leighton RK (2009) A prospective randomized controlled trial of a bioresorbable calcium phosphate paste (alpha-BSM) in treatment of displaced intra-articular calcaneal fractures. J Trauma 67:875–882. doi:10.​1097/​TA.​0b013e3181ae2d50​ PubMedCrossRef
Metadaten
Titel
A biomechanical comparison of fixed angle locking compression plate osteosynthesis and cement augmented screw osteosynthesis in the management of intra articular calcaneal fractures
verfasst von
Sascha Rausch
Kajetan Klos
Uwe Wolf
Marc Gras
Paul Simons
Steffen Brodt
Markus Windolf
Boyko Gueorguiev
Publikationsdatum
01.08.2014
Verlag
Springer Berlin Heidelberg
Erschienen in
International Orthopaedics / Ausgabe 8/2014
Print ISSN: 0341-2695
Elektronische ISSN: 1432-5195
DOI
https://doi.org/10.1007/s00264-014-2334-x

Weitere Artikel der Ausgabe 8/2014

International Orthopaedics 8/2014 Zur Ausgabe

Arthropedia

Grundlagenwissen der Arthroskopie und Gelenkchirurgie. Erweitert durch Fallbeispiele, Videos und Abbildungen. 
» Jetzt entdecken