Skip to main content
Erschienen in: International Orthopaedics 10/2014

01.10.2014 | Original Paper

Proximal humeral fractures: an understanding of the ideal plate positioning

verfasst von: Pedro José Labronici, Rodrigo Pires e Albuquerque, Vinícius Schott, Robinson Esteves Santos Pires, Willian Dias Belangero, José Sérgio Franco

Erschienen in: International Orthopaedics | Ausgabe 10/2014

Einloggen, um Zugang zu erhalten

Abstract

Purpose

The present study aims to evaluate if the bicipital groove can be used as a parameter for ideal plate positioning in proximal humeral fixation applying locking compression plate.

Method

The authors questioned whether the bicipital groove can be used as a parameter for ideal plate positioning applying locking compression plate for proximal humeral fractures. A method using the bicipital groove as the main parameter was developed using computed tomography scan (CT-scan). Seventy shoulders presenting fracture absence were used to calculate proper plate positioning, allowing the largest area for locked screw placement into the humeral head. Intraclass correlation coefficient and Bland and Altman graphics calculated intra-observer reliability for CT-scan evaluation.

Results

All observers presented satisfactory plate positioning using this method. The mean differences for observers were close to zero, suggesting high interobserver reproducibility. A significant (p <0.0001) intra-observer agreement existed for the three evaluators. Observer 2 agreement was the strongest (ICC = 0.98), showing almost perfect reproducibility measurement, followed by observer 3 (ICC = 0.84) with good reproducibility, and lastly observer 1 demonstrated moderate degree agreement (ICC = 0.47).

Conclusion

Considering the CT-scan analysis, the bicipital groove can be used as a parameter for ideal plate positioning in proximal humeral fractures. This method demonstrated satisfactory intra-observer reproducibility. Adopting this method, longer and better distributed screw placement provides more stable fixation for proximal humeral fractures.
Literatur
1.
Zurück zum Zitat Nayak NK, Schickendantz MS, Regan WD, Hawkins RJ (1995) Operative treatment of nonunion of surgical neck fractures of the humerus. Clin Orthop Relat Res 313:200–205PubMed Nayak NK, Schickendantz MS, Regan WD, Hawkins RJ (1995) Operative treatment of nonunion of surgical neck fractures of the humerus. Clin Orthop Relat Res 313:200–205PubMed
2.
Zurück zum Zitat Volgas DA, Stannard JP, Alonso JE (2004) Nonunions of the humerus. Clin Orthop Relat Res 419:46–50PubMedCrossRef Volgas DA, Stannard JP, Alonso JE (2004) Nonunions of the humerus. Clin Orthop Relat Res 419:46–50PubMedCrossRef
3.
Zurück zum Zitat Schlegel TF, Hawkins RJ (1994) Displaced proximal humeral fractures: evaluation and treatment. J Am Acad Orthop Surg 2:54–78PubMed Schlegel TF, Hawkins RJ (1994) Displaced proximal humeral fractures: evaluation and treatment. J Am Acad Orthop Surg 2:54–78PubMed
4.
Zurück zum Zitat Neer CS 2nd (1970) Displaced proximal humeral fractures I. Classification and evaluation. J Bone Joint Surg Am 52:1077–1089PubMed Neer CS 2nd (1970) Displaced proximal humeral fractures I. Classification and evaluation. J Bone Joint Surg Am 52:1077–1089PubMed
5.
Zurück zum Zitat Park MC, Murthi AM, Roth NS, Blaine TA, Levine WN, Bigliani LU (2003) Two-part and three-part fractures of the proximal humerus treated with suture fixation. J Orthop Trauma 17:319–325PubMedCrossRef Park MC, Murthi AM, Roth NS, Blaine TA, Levine WN, Bigliani LU (2003) Two-part and three-part fractures of the proximal humerus treated with suture fixation. J Orthop Trauma 17:319–325PubMedCrossRef
6.
Zurück zum Zitat Ogiwara N, Aoki M, Okamura K, Fukushima S (1996) Ender nailing for unstable surgical neck fractures of the humerus in elderly patients. Clin Orthop Relat Res 330:173–180PubMedCrossRef Ogiwara N, Aoki M, Okamura K, Fukushima S (1996) Ender nailing for unstable surgical neck fractures of the humerus in elderly patients. Clin Orthop Relat Res 330:173–180PubMedCrossRef
7.
Zurück zum Zitat Resch H, Povacz P, Fröhlich R, Wambacher M (1997) Percutaneous fixation of three- and four-part fractures of the proximal humerus. J Bone Joint Surg (Br) 79:295–300CrossRef Resch H, Povacz P, Fröhlich R, Wambacher M (1997) Percutaneous fixation of three- and four-part fractures of the proximal humerus. J Bone Joint Surg (Br) 79:295–300CrossRef
8.
Zurück zum Zitat Robinson CM, Page RS, Hill RM, Sanders DL, Court-Brown CM, Wakefield AE (2003) Primary hemiarthroplasty for treatment of proximal humeral fractures. J Bone Joint Surg Am 85:1215–1223PubMedCrossRef Robinson CM, Page RS, Hill RM, Sanders DL, Court-Brown CM, Wakefield AE (2003) Primary hemiarthroplasty for treatment of proximal humeral fractures. J Bone Joint Surg Am 85:1215–1223PubMedCrossRef
9.
Zurück zum Zitat Tamai K, Ishige N, Kuroda S, Ohno W, Itoh H, Hashiguchi H, Iizawa N, Mikasa M (2009) Four-segment classification of proximal humeral fractures revisited: a multicenter study on 509 cases. J Shoulder Elbow Surg 18(6):845–850PubMedCrossRef Tamai K, Ishige N, Kuroda S, Ohno W, Itoh H, Hashiguchi H, Iizawa N, Mikasa M (2009) Four-segment classification of proximal humeral fractures revisited: a multicenter study on 509 cases. J Shoulder Elbow Surg 18(6):845–850PubMedCrossRef
10.
Zurück zum Zitat Owsley KC, Gorczyca JT (2008) Fracture displacement and screw cutout after open reduction and locked plate fixation of proximal humeral fractures [corrected]. J Bone Joint Surg Am 90(2):233–240PubMedCrossRef Owsley KC, Gorczyca JT (2008) Fracture displacement and screw cutout after open reduction and locked plate fixation of proximal humeral fractures [corrected]. J Bone Joint Surg Am 90(2):233–240PubMedCrossRef
11.
Zurück zum Zitat Frigg R (2003) Development of the locking compression plate. Injury 34 Suppl 2:B6-10 Frigg R (2003) Development of the locking compression plate. Injury 34 Suppl 2:B6-10
12.
Zurück zum Zitat Lungershausen W, Bach O, Lorenz CO (2003) Locking plate osteosynthesis for fractures of the proximal humerus. Zentralbl Chir 128:28–33PubMedCrossRef Lungershausen W, Bach O, Lorenz CO (2003) Locking plate osteosynthesis for fractures of the proximal humerus. Zentralbl Chir 128:28–33PubMedCrossRef
13.
Zurück zum Zitat Lill H, Hepp P, Rose T et al (2004) The angle stable locking-proximal-humerus plate (LPHP) for proximal humeral fractures using a small anterior-lateral deltoid-splitting-approach technique and first results. Zentralbl Chir 129:43–48PubMedCrossRef Lill H, Hepp P, Rose T et al (2004) The angle stable locking-proximal-humerus plate (LPHP) for proximal humeral fractures using a small anterior-lateral deltoid-splitting-approach technique and first results. Zentralbl Chir 129:43–48PubMedCrossRef
14.
Zurück zum Zitat Bjorkenheim JM, Pajarinen J, Savolainen V (2004) Internal fixation of proximal humeral fractures with a locking compression plate: a retrospective evaluation of 72 patients followed for a minimum of 1 year. Acta Orthop Scand 750:741–745CrossRef Bjorkenheim JM, Pajarinen J, Savolainen V (2004) Internal fixation of proximal humeral fractures with a locking compression plate: a retrospective evaluation of 72 patients followed for a minimum of 1 year. Acta Orthop Scand 750:741–745CrossRef
15.
Zurück zum Zitat Seide K, Triebe J, Faschingbauer M et al (2007) Locked vs. unlocked plate osteosynthesis of the proximal humerus—a biomechanical study. Clin Biomech (Bristol, Avon) 22:176–182CrossRef Seide K, Triebe J, Faschingbauer M et al (2007) Locked vs. unlocked plate osteosynthesis of the proximal humerus—a biomechanical study. Clin Biomech (Bristol, Avon) 22:176–182CrossRef
16.
Zurück zum Zitat Edwards SL, Wilson NA, Zhang LQ (2006) Two-part surgical neck fractures of the proximal part of the humerus. A biomechanical evaluation of two fixation techniques. J Bone Joint Surg Am 88:2258–2264PubMedCrossRef Edwards SL, Wilson NA, Zhang LQ (2006) Two-part surgical neck fractures of the proximal part of the humerus. A biomechanical evaluation of two fixation techniques. J Bone Joint Surg Am 88:2258–2264PubMedCrossRef
17.
Zurück zum Zitat Hessler C, Schmucker U, Matthes G et al (2006) Results after treatment of unstable fractures of the proximal humerus using a fixed-angle plate. Unfallchirurg 109:867–874PubMedCrossRef Hessler C, Schmucker U, Matthes G et al (2006) Results after treatment of unstable fractures of the proximal humerus using a fixed-angle plate. Unfallchirurg 109:867–874PubMedCrossRef
18.
Zurück zum Zitat Koukakis A, Apostolou CD, Taneja T et al (2006) Fixation of proximal humerus fractures using the PHILOS plate: early experience. Clin Orthop Relat Res 442:115–120PubMedCrossRef Koukakis A, Apostolou CD, Taneja T et al (2006) Fixation of proximal humerus fractures using the PHILOS plate: early experience. Clin Orthop Relat Res 442:115–120PubMedCrossRef
19.
Zurück zum Zitat Siffri PC, Peindl RD, Coley ER et al (2006) Biomechanical analysis of blade plate versus locking plate fixation for a proximal humerus fracture: comparison using cadaveric and synthetic humeri. J Orthop Trauma 20:547–554PubMedCrossRef Siffri PC, Peindl RD, Coley ER et al (2006) Biomechanical analysis of blade plate versus locking plate fixation for a proximal humerus fracture: comparison using cadaveric and synthetic humeri. J Orthop Trauma 20:547–554PubMedCrossRef
20.
Zurück zum Zitat Agudelo J, Schürmann M, Stahel P, Helwig RP, Morgan SJ, Zechel W, Bahrs C, Parekh A, Ziran B, Williams A, Smith WR (2007) Analysis of efficacy and failure in proximal humerus fractures treated with locking plates. J Orthop Trauma 21(10):676–681PubMedCrossRef Agudelo J, Schürmann M, Stahel P, Helwig RP, Morgan SJ, Zechel W, Bahrs C, Parekh A, Ziran B, Williams A, Smith WR (2007) Analysis of efficacy and failure in proximal humerus fractures treated with locking plates. J Orthop Trauma 21(10):676–681PubMedCrossRef
21.
Zurück zum Zitat Egol KA, Ong CC, Walsh M et al (2008) Early complications in proximal humerus fractures OTA Types 11 treated with locked plates. J Orthop Trauma 22:159–164PubMedCrossRef Egol KA, Ong CC, Walsh M et al (2008) Early complications in proximal humerus fractures OTA Types 11 treated with locked plates. J Orthop Trauma 22:159–164PubMedCrossRef
22.
Zurück zum Zitat Lee CW, Shin SJ (2009) Prognostic factors for unstable proximal humeral fractures treated with locking-plate fixation. J Should Elb Surg 18:83–88CrossRef Lee CW, Shin SJ (2009) Prognostic factors for unstable proximal humeral fractures treated with locking-plate fixation. J Should Elb Surg 18:83–88CrossRef
23.
Zurück zum Zitat Rose PS, Adams CR, Torchia ME et al (2007) Locking plate fixation for proximal humeral fractures: initial results with a new implant. J Should Elb Surg 16:202–207CrossRef Rose PS, Adams CR, Torchia ME et al (2007) Locking plate fixation for proximal humeral fractures: initial results with a new implant. J Should Elb Surg 16:202–207CrossRef
24.
Zurück zum Zitat Solberg BD, Moon CN, Franco DP et al (2009) Locked plating of 3- and 4-part proximal humeral fractures in older patients: the effect of initial fracture pattern on outcome. J Orthop Trauma 23:113–119PubMedCrossRef Solberg BD, Moon CN, Franco DP et al (2009) Locked plating of 3- and 4-part proximal humeral fractures in older patients: the effect of initial fracture pattern on outcome. J Orthop Trauma 23:113–119PubMedCrossRef
25.
Zurück zum Zitat Gardner MJ, Weil Y, Barker JU et al (2007) The importance of medial support in locked plating of proximal humerus fractures. J Orthop Trauma 21:185–191PubMedCrossRef Gardner MJ, Weil Y, Barker JU et al (2007) The importance of medial support in locked plating of proximal humerus fractures. J Orthop Trauma 21:185–191PubMedCrossRef
26.
Zurück zum Zitat Balg F, Boulianne M, Boileau P (2006) Bicipital groove orientation: considerations for the retroversion of a prosthesis in fractures of the proximal humerus. J Should Elb Surg 15:195–198CrossRef Balg F, Boulianne M, Boileau P (2006) Bicipital groove orientation: considerations for the retroversion of a prosthesis in fractures of the proximal humerus. J Should Elb Surg 15:195–198CrossRef
27.
Zurück zum Zitat Christoforakis J, Kontakis GM, Maris T, Damilakis J, Katonis P, Prassopoulos P et al (2001) An individualized approach for the implantation of a humeral prosthesis with the proper retroversion in fractures. Arch Orthop Trauma Surg 121:227–229PubMedCrossRef Christoforakis J, Kontakis GM, Maris T, Damilakis J, Katonis P, Prassopoulos P et al (2001) An individualized approach for the implantation of a humeral prosthesis with the proper retroversion in fractures. Arch Orthop Trauma Surg 121:227–229PubMedCrossRef
28.
Zurück zum Zitat Greiner SH, Kaab MJ, Kroning I, Scheibel M, Perka C (2008) Reconstruction of humeral length and centering of the prosthetic head in hemiarthroplasty for proximal humeral fractures. J Should Elb Surg 17:709–714CrossRef Greiner SH, Kaab MJ, Kroning I, Scheibel M, Perka C (2008) Reconstruction of humeral length and centering of the prosthetic head in hemiarthroplasty for proximal humeral fractures. J Should Elb Surg 17:709–714CrossRef
29.
Zurück zum Zitat Hempfing A, Leunig M, Ballmer FT, Hertel R (2001) Surgical landmarks to determine humeral head retrotorsion for hemiarthroplasty in fractures. J Should Elb Surg 10:460–463CrossRef Hempfing A, Leunig M, Ballmer FT, Hertel R (2001) Surgical landmarks to determine humeral head retrotorsion for hemiarthroplasty in fractures. J Should Elb Surg 10:460–463CrossRef
30.
Zurück zum Zitat Itamura J, Dietrick T, Roidis N, Shean C, Chen F, Tibone J (2002) Analysis of the bicipital groove as a landmark for humeral head replacement. J Should Elb Surg 11:322–326CrossRef Itamura J, Dietrick T, Roidis N, Shean C, Chen F, Tibone J (2002) Analysis of the bicipital groove as a landmark for humeral head replacement. J Should Elb Surg 11:322–326CrossRef
31.
Zurück zum Zitat Kontakis GM, Damilakis J, Christoforakis J, Papadakis A, Katonis P, Prassopoulos P (2001) The bicipital groove as a landmark for orientation of the humeral prosthesis in cases of fracture. J Should Elb Surg 10:136–139CrossRef Kontakis GM, Damilakis J, Christoforakis J, Papadakis A, Katonis P, Prassopoulos P (2001) The bicipital groove as a landmark for orientation of the humeral prosthesis in cases of fracture. J Should Elb Surg 10:136–139CrossRef
32.
Zurück zum Zitat Murachovsky J, Ikemoto RY, Nascimento LG, Fujiki EN, Milani C, Warner JJ (2006) Pectoralis major tendon reference (PMT): a new method for accurate restoration of humeral length with hemiarthroplasty for fracture. J Should Elb Surg 15:675–678CrossRef Murachovsky J, Ikemoto RY, Nascimento LG, Fujiki EN, Milani C, Warner JJ (2006) Pectoralis major tendon reference (PMT): a new method for accurate restoration of humeral length with hemiarthroplasty for fracture. J Should Elb Surg 15:675–678CrossRef
33.
Zurück zum Zitat Torrens C, Corrales M, Melendo E, Solano A, Rodriguez-Baeza A, Caceres E (2008) The pectoralis major tendon as a reference for restoring humeral length and retroversion with hemiarthroplasty for fracture. J Should Elb Surg 17:947–950CrossRef Torrens C, Corrales M, Melendo E, Solano A, Rodriguez-Baeza A, Caceres E (2008) The pectoralis major tendon as a reference for restoring humeral length and retroversion with hemiarthroplasty for fracture. J Should Elb Surg 17:947–950CrossRef
34.
Zurück zum Zitat Tingart M, Lehtinen J, Zurakowski D (2006) Proximal humerus fractures: regional differences in bone mineral density of the humeral head affect fixation strength of cancellous screws. J Should Elb Surg 15:620–624CrossRef Tingart M, Lehtinen J, Zurakowski D (2006) Proximal humerus fractures: regional differences in bone mineral density of the humeral head affect fixation strength of cancellous screws. J Should Elb Surg 15:620–624CrossRef
35.
Zurück zum Zitat Barvencik F, Gebauer M, Beil FT et al (2010) Age and sex-related changes of the humeral head microarchitecture: Histomorphic analysis of 60 human specimens. J Orthop Res 28:18–26PubMed Barvencik F, Gebauer M, Beil FT et al (2010) Age and sex-related changes of the humeral head microarchitecture: Histomorphic analysis of 60 human specimens. J Orthop Res 28:18–26PubMed
36.
Zurück zum Zitat Sudkamp N, Bayer J, Hepp P et al (2009) Open reduction and internal fixation of proximal humerus fractures with use of the locking proximal humerus plate: results of a prospective, multicenter, observational study. J Bone Joint Surg Am 91:1320–1328PubMedCrossRef Sudkamp N, Bayer J, Hepp P et al (2009) Open reduction and internal fixation of proximal humerus fractures with use of the locking proximal humerus plate: results of a prospective, multicenter, observational study. J Bone Joint Surg Am 91:1320–1328PubMedCrossRef
37.
Zurück zum Zitat Schulte LM, Matteini LE, Neviaser RJ (2011) Proximal periarticular locking plates in proximal humeral fractures: functional outcomes. J Shoulder Elbow Surg 20:1234–1240PubMedCrossRef Schulte LM, Matteini LE, Neviaser RJ (2011) Proximal periarticular locking plates in proximal humeral fractures: functional outcomes. J Shoulder Elbow Surg 20:1234–1240PubMedCrossRef
38.
Zurück zum Zitat Nho SJ, Brophy RH, Barker JU, Cornell CN, MacGillivry JD (2007) Innovations in the management of displaced proximal humerus fractures. J Am Acad Orthop Surg 15:12–28PubMed Nho SJ, Brophy RH, Barker JU, Cornell CN, MacGillivry JD (2007) Innovations in the management of displaced proximal humerus fractures. J Am Acad Orthop Surg 15:12–28PubMed
39.
Zurück zum Zitat Robinson CM, Wylie JR, Ray AG et al (2010) Proximal humeral fractures with a severe varus deformity treated by fixation with a locking plate. J Bone Joint Surg (Br) 92:672–678CrossRef Robinson CM, Wylie JR, Ray AG et al (2010) Proximal humeral fractures with a severe varus deformity treated by fixation with a locking plate. J Bone Joint Surg (Br) 92:672–678CrossRef
40.
Zurück zum Zitat Gardner MJ, Boraiah S, Helfet DL, Lorich DG (2008) Indirect medial reduction and strut support of proximal humerus fractures using an endosteal implant. J Orthop Trauma 22:195–200PubMedCrossRef Gardner MJ, Boraiah S, Helfet DL, Lorich DG (2008) Indirect medial reduction and strut support of proximal humerus fractures using an endosteal implant. J Orthop Trauma 22:195–200PubMedCrossRef
41.
Zurück zum Zitat Clement ND (2013) Can we decipher indications and outcomes of the PHILOS plate for fractures of the proximal humerus? Int Orthop 37(6):1199–1200PubMedCrossRefPubMedCentral Clement ND (2013) Can we decipher indications and outcomes of the PHILOS plate for fractures of the proximal humerus? Int Orthop 37(6):1199–1200PubMedCrossRefPubMedCentral
42.
Zurück zum Zitat Röderer G, Erhardt J, Kuster M, Vegt P, Bahrs C, Kinzl L, Gebhard F (2011) Second generation locked plating of proximal humerus fractures—a prospective multicentre observational study. Int Orthop 35(3):425–432PubMedCrossRefPubMedCentral Röderer G, Erhardt J, Kuster M, Vegt P, Bahrs C, Kinzl L, Gebhard F (2011) Second generation locked plating of proximal humerus fractures—a prospective multicentre observational study. Int Orthop 35(3):425–432PubMedCrossRefPubMedCentral
43.
Zurück zum Zitat Zhang L, Zheng J, Wang W, Lin G, Huang Y, Zheng J, Edem Prince GA, Yang G (2011) The clinical benefit of medial support screws in locking plating of proximal humerus fractures: a prospective randomized study. Int Orthop 35(11):1655–1661PubMedCrossRefPubMedCentral Zhang L, Zheng J, Wang W, Lin G, Huang Y, Zheng J, Edem Prince GA, Yang G (2011) The clinical benefit of medial support screws in locking plating of proximal humerus fractures: a prospective randomized study. Int Orthop 35(11):1655–1661PubMedCrossRefPubMedCentral
Metadaten
Titel
Proximal humeral fractures: an understanding of the ideal plate positioning
verfasst von
Pedro José Labronici
Rodrigo Pires e Albuquerque
Vinícius Schott
Robinson Esteves Santos Pires
Willian Dias Belangero
José Sérgio Franco
Publikationsdatum
01.10.2014
Verlag
Springer Berlin Heidelberg
Erschienen in
International Orthopaedics / Ausgabe 10/2014
Print ISSN: 0341-2695
Elektronische ISSN: 1432-5195
DOI
https://doi.org/10.1007/s00264-014-2463-2

Weitere Artikel der Ausgabe 10/2014

International Orthopaedics 10/2014 Zur Ausgabe

Arthropedia

Grundlagenwissen der Arthroskopie und Gelenkchirurgie. Erweitert durch Fallbeispiele, Videos und Abbildungen. 
» Jetzt entdecken

Update Orthopädie und Unfallchirurgie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.