Skip to main content
Erschienen in: International Orthopaedics 4/2016

01.04.2016 | Original Paper

Is computed tomography an accurate and reliable method for measuring total knee arthroplasty component rotation?

verfasst von: José Figueroa, Juan Pablo Guarachi, José Matas, Magnus Arnander, Mario Orrego

Erschienen in: International Orthopaedics | Ausgabe 4/2016

Einloggen, um Zugang zu erhalten

Abstract

Purpose

Computed tomography (CT) is widely used to assess component rotation in patients with poor results after total knee arthroplasty (TKA). The purpose of this study was to simultaneously determine the accuracy and reliability of CT in measuring TKA component rotation.

Methods

TKA components were implanted in dry-bone models and assigned to two groups. The first group (n = 7) had variable femoral component rotations, and the second group (n = 6) had variable tibial tray rotations. CT images were then used to assess component rotation. Accuracy of CT rotational assessment was determined by mean difference, in degrees, between implanted component rotation and CT-measured rotation. Intraclass correlation coefficient (ICC) was applied to determine intra-observer and inter-observer reliability.

Results

Femoral component accuracy showed a mean difference of 2.5° and the tibial tray a mean difference of 3.2°. There was good intra- and inter-observer reliability for both components, with a femoral ICC of 0.8 and 0.76, and tibial ICC of 0.68 and 0.65, respectively.

Conclusions

CT rotational assessment accuracy can differ from true component rotation by approximately 3° for each component. It does, however, have good inter- and intra-observer reliability.
Literatur
1.
Zurück zum Zitat Rand JA, Trousdale RT, Ilstrup DM, Harmsen WS (2003) Factors affecting the durability of primary total knee prostheses. J Bone Joint Surg Am 85-A(2):259–265PubMed Rand JA, Trousdale RT, Ilstrup DM, Harmsen WS (2003) Factors affecting the durability of primary total knee prostheses. J Bone Joint Surg Am 85-A(2):259–265PubMed
3.
Zurück zum Zitat Robertsson O, Dunbar M, Pehrsson T, Knutson K, Lidgren L (2000) Patient satisfaction after knee arthroplasty: a report on 27,372 knees operated on between 1981 and 1995 in Sweden. Acta Orthop Scand 71(3):262–267. doi:10.1080/000164700317411852 CrossRefPubMed Robertsson O, Dunbar M, Pehrsson T, Knutson K, Lidgren L (2000) Patient satisfaction after knee arthroplasty: a report on 27,372 knees operated on between 1981 and 1995 in Sweden. Acta Orthop Scand 71(3):262–267. doi:10.​1080/​0001647003174118​52 CrossRefPubMed
4.
Zurück zum Zitat Baker PN, van der Meulen JH, Lewsey J, Gregg PJ (2007) National Joint Registry for England and Wales. The role of pain and function in determining patient satisfaction after total knee replacement. Data from the National Joint Registry for England and Wales. J Bone Joint Surg (Br) 89(7):893–900. doi:10.1302/0301-620x.89b7.19091 CrossRef Baker PN, van der Meulen JH, Lewsey J, Gregg PJ (2007) National Joint Registry for England and Wales. The role of pain and function in determining patient satisfaction after total knee replacement. Data from the National Joint Registry for England and Wales. J Bone Joint Surg (Br) 89(7):893–900. doi:10.​1302/​0301-620x.​89b7.​19091 CrossRef
9.
Zurück zum Zitat Tay KS, Lo NN, Yeo SJ, Chia SL, Tay DK, Chin PL (2013) Revision total knee arthroplasty: causes and outcomes. Ann Acad Med Singap 42(4):178–183PubMed Tay KS, Lo NN, Yeo SJ, Chia SL, Tay DK, Chin PL (2013) Revision total knee arthroplasty: causes and outcomes. Ann Acad Med Singap 42(4):178–183PubMed
13.
Zurück zum Zitat Schroer WC, Berend KR, Lombardi AV, Barnes CL, Bolognesi MP, Berend ME, Ritter MA, Nunley RM (2013) Why are total knees failing today? Etiology of total knee revision in 2010 and 2011. J Arthroplast 28(8 Suppl). doi: 10.1016/j.arth.2013.04.056 Schroer WC, Berend KR, Lombardi AV, Barnes CL, Bolognesi MP, Berend ME, Ritter MA, Nunley RM (2013) Why are total knees failing today? Etiology of total knee revision in 2010 and 2011. J Arthroplast 28(8 Suppl). doi: 10.​1016/​j.​arth.​2013.​04.​056
15.
Zurück zum Zitat Merkow RL, Soudry M, Insall JN (1985) Patellar dislocation following total knee replacement. J Bone Joint Surg Am 67(9):1321–1327PubMed Merkow RL, Soudry M, Insall JN (1985) Patellar dislocation following total knee replacement. J Bone Joint Surg Am 67(9):1321–1327PubMed
19.
Zurück zum Zitat Hirschmann MT, Konala P, Amsler F, Iranpour F, Friederich NF, Cobb JP (2011) The position and orientation of total knee replacement components: a comparison of conventional radiographs, transverse 2D-CT slices and 3D-CT reconstruction. J Bone Joint Surg (Br) 93(5):629–633. doi:10.1302/0301-620x.93b5.25893 CrossRef Hirschmann MT, Konala P, Amsler F, Iranpour F, Friederich NF, Cobb JP (2011) The position and orientation of total knee replacement components: a comparison of conventional radiographs, transverse 2D-CT slices and 3D-CT reconstruction. J Bone Joint Surg (Br) 93(5):629–633. doi:10.​1302/​0301-620x.​93b5.​25893 CrossRef
20.
Zurück zum Zitat White D, Chelule KL, Seedhom BB (2008) Accuracy of MRI vs CT imaging with particular reference to patient specific templates for total knee replacement surgery. Int J Med Robot 4(3):224–231. doi:10.1002/rcs.201 CrossRefPubMed White D, Chelule KL, Seedhom BB (2008) Accuracy of MRI vs CT imaging with particular reference to patient specific templates for total knee replacement surgery. Int J Med Robot 4(3):224–231. doi:10.​1002/​rcs.​201 CrossRefPubMed
21.
Zurück zum Zitat Jazrawi LM, Birdzell L, Kummer FJ, Di Cesare PE (2000) The accuracy of computed tomography for determining femoral and tibial total knee arthroplasty component rotation. J Arthroplasty 15(6):761–766. doi:10.1054/arth.2000.8193 CrossRefPubMed Jazrawi LM, Birdzell L, Kummer FJ, Di Cesare PE (2000) The accuracy of computed tomography for determining femoral and tibial total knee arthroplasty component rotation. J Arthroplasty 15(6):761–766. doi:10.​1054/​arth.​2000.​8193 CrossRefPubMed
23.
Zurück zum Zitat Zimmer® MIS Multi-Reference® 4 – in – 1 Femoral instrumentation. Surgical Technique. Rev. 6 5 ML Printed in USA 2003, 2005, 2008 Zimmer, Inc. Zimmer® MIS Multi-Reference® 4 – in – 1 Femoral instrumentation. Surgical Technique. Rev. 6 5 ML Printed in USA 2003, 2005, 2008 Zimmer, Inc.
24.
Zurück zum Zitat Vail T, Lang J (2006) Surgical techniques and instrumentation in total knee arthroplasty. In: Scott W, Insall J (eds) Insall & Scott surgery of the knee, 4th edn. Elsevier/Churchill Livingstone, Philadelphia Vail T, Lang J (2006) Surgical techniques and instrumentation in total knee arthroplasty. In: Scott W, Insall J (eds) Insall & Scott surgery of the knee, 4th edn. Elsevier/Churchill Livingstone, Philadelphia
28.
Zurück zum Zitat Chauhan SK, Clark GW, Lloyd S, Scott RG, Breidahl W, Sikorski JM (2004) Computer-assisted total knee replacement. A controlled cadaver study using a multi-parameter quantitative CT assessment of alignment (the Perth CT Protocol). J Bone Joint Surg (Br) 86(6):818–823. doi:10.1302/0301-620X.86B6.15456 CrossRef Chauhan SK, Clark GW, Lloyd S, Scott RG, Breidahl W, Sikorski JM (2004) Computer-assisted total knee replacement. A controlled cadaver study using a multi-parameter quantitative CT assessment of alignment (the Perth CT Protocol). J Bone Joint Surg (Br) 86(6):818–823. doi:10.​1302/​0301-620X.​86B6.​15456 CrossRef
Metadaten
Titel
Is computed tomography an accurate and reliable method for measuring total knee arthroplasty component rotation?
verfasst von
José Figueroa
Juan Pablo Guarachi
José Matas
Magnus Arnander
Mario Orrego
Publikationsdatum
01.04.2016
Verlag
Springer Berlin Heidelberg
Erschienen in
International Orthopaedics / Ausgabe 4/2016
Print ISSN: 0341-2695
Elektronische ISSN: 1432-5195
DOI
https://doi.org/10.1007/s00264-015-2917-1

Weitere Artikel der Ausgabe 4/2016

International Orthopaedics 4/2016 Zur Ausgabe

Arthropedia

Grundlagenwissen der Arthroskopie und Gelenkchirurgie. Erweitert durch Fallbeispiele, Videos und Abbildungen. 
» Jetzt entdecken

Update Orthopädie und Unfallchirurgie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.