Abstract

Purpose

As worldwide use of reverse shoulder arthroplasty (RSA) increases, a range of implant sizes may be required to match regional and ethnic variation in patients’ height and bone size. The purpose of this study was to report the outcomes of RSA using a mini 25-mm-diameter glenoid baseplate in smaller patients with rotator cuff arthropathy.

Methods

Between 2009 and 2012, 28 patients underwent RSA for cuff-tear arthropathy using a 25-mm circular glenoid baseplate (Aequlais Reversed, Tornier, Bloomington, MN, USA). Twenty-four patients were able to return for comprehensive follow-up. The mean height of the entire cohort was 158 ± 10 cm (5 ft. 2 in.). The indication to use a smaller baseplate was a combination of preoperative templating using computed tomography (CT) and intraoperative measurements of glenoid width.

Results

At a mean of 36 ± 8 months’ follow-up, there were no revisions or glenoid-sided failures. The mean American Shoulder and Elbow Surgeons (ASES) score was 70 ± 10, the Simple Shoulder Test (SST) was 10 ± 2, the Constant was 60 ± 10 and the Disabilities of the Arm, Shoulder and Hand (DASH) was 18 ± 15. Mean active forward elevation was 140 ± 15°, active external rotation was 21 ± 15° and active internal rotation was to the sacroiliac joint. Mean shoulder strength in flexion was 5.2 ± 1.7 kg, in external rotation was 2.9 ± 1.4 kg and in internal rotation was 4.3 ± 1.2 kg. Radiographs demonstrated no evidence of glenoid loosening. There was, however, a 62 % rate of scapular notching.

Conclusions

Short-term outcomes of mini 25-mm baseplate RSA in proportionally smaller patients are good and demonstrate implant safety and effectiveness. Scapular notching rates are worrisome, and additional follow-up is necessary to determine if notching is progressive and becomes symptomatic.
Literatur
5.
Zurück zum Zitat De Biase CF, Ziveri G, Delcogliano M, de Caro F, Gumina S, Borroni M, Castagna A, Postacchini R (2013) The use of an eccentric glenosphere compared with a concentric glenosphere in reverse total shoulder arthroplasty: two-year minimum follow-up results. Int Orthop 37(10):1949–1955. doi:10.1007/s00264-013-1947-9 PubMedPubMedCentralCrossRef De Biase CF, Ziveri G, Delcogliano M, de Caro F, Gumina S, Borroni M, Castagna A, Postacchini R (2013) The use of an eccentric glenosphere compared with a concentric glenosphere in reverse total shoulder arthroplasty: two-year minimum follow-up results. Int Orthop 37(10):1949–1955. doi:10.​1007/​s00264-013-1947-9 PubMedPubMedCentralCrossRef
7.
Zurück zum Zitat Namdari S, Horneff JG, Baldwin K (2013) Comparison of hemiarthroplasty and reverse arthroplasty for treatment of proximal humeral fractures: a systematic review. J Bone Joint Surg Am 95(18):1701–1708. doi:10.2106/JBJS.L.01115 PubMedCrossRef Namdari S, Horneff JG, Baldwin K (2013) Comparison of hemiarthroplasty and reverse arthroplasty for treatment of proximal humeral fractures: a systematic review. J Bone Joint Surg Am 95(18):1701–1708. doi:10.​2106/​JBJS.​L.​01115 PubMedCrossRef
9.
Zurück zum Zitat Giurazza F, Del Vescovo R, Schena E, Cazzato RL, D’Agostino F, Grasso RF, Silvestri S, Zobel BB (2013) Stature estimation from scapular measurements by CT scan evaluation in an Italian population. Leg Med 15(4):202–208. doi:10.1016/j.legalmed.2013.01.002 CrossRef Giurazza F, Del Vescovo R, Schena E, Cazzato RL, D’Agostino F, Grasso RF, Silvestri S, Zobel BB (2013) Stature estimation from scapular measurements by CT scan evaluation in an Italian population. Leg Med 15(4):202–208. doi:10.​1016/​j.​legalmed.​2013.​01.​002 CrossRef
12.
Zurück zum Zitat Sirveaux F, Favard L, Oudet D, Huquet D, Walch G, Mole D (2004) Grammont inverted total shoulder arthroplasty in the treatment of glenohumeral osteoarthritis with massive rupture of the cuff. Results of a multicentre study of 80 shoulders. J Bone Joint Surg Br 86(3):388–395PubMedCrossRef Sirveaux F, Favard L, Oudet D, Huquet D, Walch G, Mole D (2004) Grammont inverted total shoulder arthroplasty in the treatment of glenohumeral osteoarthritis with massive rupture of the cuff. Results of a multicentre study of 80 shoulders. J Bone Joint Surg Br 86(3):388–395PubMedCrossRef
13.
Zurück zum Zitat Rahimtoola ZO, Finger S, Imrie S, Goodman SB (2000) Outcome of total hip arthroplasty in small-proportioned patients. J Arthroplasty 15(1):27–34PubMedCrossRef Rahimtoola ZO, Finger S, Imrie S, Goodman SB (2000) Outcome of total hip arthroplasty in small-proportioned patients. J Arthroplasty 15(1):27–34PubMedCrossRef
14.
Zurück zum Zitat Oh KJ, Imrie S, Hwang K, Ramachandran R, Shegog M, Goodman SB (2006) Total hip arthroplasty using the miniature Anatomic Medullary Locking stem. Clin Orthop Relat Res 447:85–91PubMedCrossRef Oh KJ, Imrie S, Hwang K, Ramachandran R, Shegog M, Goodman SB (2006) Total hip arthroplasty using the miniature Anatomic Medullary Locking stem. Clin Orthop Relat Res 447:85–91PubMedCrossRef
15.
Zurück zum Zitat Shang P, Zhang L, Hou Z, Bai X, Ye X, Xu Z, Huang X (2014) Morphometric measurement of the patella on 3D model reconstructed from CT scan images for the southern Chinese population. Chin Med J (Engl) 127(1):96–101 Shang P, Zhang L, Hou Z, Bai X, Ye X, Xu Z, Huang X (2014) Morphometric measurement of the patella on 3D model reconstructed from CT scan images for the southern Chinese population. Chin Med J (Engl) 127(1):96–101
16.
Zurück zum Zitat Chen IH, Hou CH, Huang CI, Lee LS (1994) Measurement of Chinese lumbar pedicles: with special reference to transpedicular screw fixation. Zhonghua Yi Xue Za Zhi 53(6):351–356PubMed Chen IH, Hou CH, Huang CI, Lee LS (1994) Measurement of Chinese lumbar pedicles: with special reference to transpedicular screw fixation. Zhonghua Yi Xue Za Zhi 53(6):351–356PubMed
Metadaten
Titel
Outcomes of reverse shoulder arthroplasty using a mini 25-mm glenoid baseplate
verfasst von
George S. Athwal
Kenneth J. Faber
Publikationsdatum
01.01.2016
Verlag
Springer Berlin Heidelberg
Erschienen in
International Orthopaedics / Ausgabe 1/2016
Print ISSN: 0341-2695
Elektronische ISSN: 1432-5195
DOI
https://doi.org/10.1007/s00264-015-2945-x

Weitere Artikel der Ausgabe 1/2016

International Orthopaedics 1/2016 Zur Ausgabe

Arthropedia

Grundlagenwissen der Arthroskopie und Gelenkchirurgie. Erweitert durch Fallbeispiele, Videos und Abbildungen. 
» Jetzt entdecken

Update Orthopädie und Unfallchirurgie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.