Abstract

Purpose

Open reductions and internal fixations are currently being used the most in surgeries of humeral shaft fractures. However, there are some limitations such as invasive techniques and formation of many operation scars. To overcome these limitations, a minimally invasive plate osteosynthesis has been recently introduced. However, this has technical limitations such as deep dissections of the distal portion and narrowness of the fixation space. To address these problems, we designed another introductory technique of a minimally invasive osteosynthesis and we have examined the clinical usefulness of that.

Methods

The results were retrospectively analyzed with 83 patients who visited INHA hospital due to a humeral shaft fractures and who had undergone the above said surgery from the beginning of 2010 to the end of 2012. The patients were divided into two groups: patients treated by the MIPO technique using the newly designed dual approaches (group A) and patients treated by open reduction and plating internal fixation (group B).

Results

There was no significant difference in mean duration of injury, the mean fracture union time, range of motion and MEPI for group A and B. There was no statistical significance between the two groups. However, the occurrence of iatrogenic radial nerve palsy in group B, was significantly higher than in group A.

Conclusions

MIPOs using the dual approaches on the adult humerus shaft fracture show an excellent bony union without nerve injury which is clinically useful.
Anhänge
Nur mit Berechtigung zugänglich
Literatur
1.
Zurück zum Zitat Apivatthakakul T, Arpornchayanon O, Bavornratanavech S (2005) Minimally invasive plate osteosynthesis (MIPO) of the humeral shaft fracture. Is it possible? A cadavericstudy and preliminary report. Injury 36:530–538CrossRefPubMed Apivatthakakul T, Arpornchayanon O, Bavornratanavech S (2005) Minimally invasive plate osteosynthesis (MIPO) of the humeral shaft fracture. Is it possible? A cadavericstudy and preliminary report. Injury 36:530–538CrossRefPubMed
2.
Zurück zum Zitat Apivatthakakul T, Patiyasikan S, Luevitoonvechkit S (2010) Danger zone for locking screw placement in minimally invasive plate osteosynthesis (MIPO) of humeral shaft fractures: a cadaveric study. Injury 41(2):169–172CrossRefPubMed Apivatthakakul T, Patiyasikan S, Luevitoonvechkit S (2010) Danger zone for locking screw placement in minimally invasive plate osteosynthesis (MIPO) of humeral shaft fractures: a cadaveric study. Injury 41(2):169–172CrossRefPubMed
3.
Zurück zum Zitat Gerwin M, Hotchkiss RN, Weiland AJ (1996) Alternative operative exposures of the posterior aspect of the humeral diaphysis with reference to the radial nerve. J Bone Joint Surg Am 78-A:1690–1695CrossRef Gerwin M, Hotchkiss RN, Weiland AJ (1996) Alternative operative exposures of the posterior aspect of the humeral diaphysis with reference to the radial nerve. J Bone Joint Surg Am 78-A:1690–1695CrossRef
4.
Zurück zum Zitat Yin P, Zhang L, Mao Z et al (2014) Comparison of lateral and posterior surgical approach in management of extra-articular distal humeral shaft fractures. Injury 45(7):1121–1125CrossRefPubMed Yin P, Zhang L, Mao Z et al (2014) Comparison of lateral and posterior surgical approach in management of extra-articular distal humeral shaft fractures. Injury 45(7):1121–1125CrossRefPubMed
5.
Zurück zum Zitat Lee TJ, Kwon DG, Na SI et al (2013) Modified combined approach for distal humerus shaft fracture: anterolateral and lateral bimodal approach. Clin Orthop Surg 5:209–215CrossRefPubMedPubMedCentral Lee TJ, Kwon DG, Na SI et al (2013) Modified combined approach for distal humerus shaft fracture: anterolateral and lateral bimodal approach. Clin Orthop Surg 5:209–215CrossRefPubMedPubMedCentral
6.
Zurück zum Zitat Hee HT, Low BY, See HF (1998) Surgical results of open reduction and plating of humeral shaft fractures. Ann Acad Med Singap 27:772–775PubMed Hee HT, Low BY, See HF (1998) Surgical results of open reduction and plating of humeral shaft fractures. Ann Acad Med Singap 27:772–775PubMed
7.
Zurück zum Zitat Jawa A, McCarty P, Doornberg J et al (2006) Extra-articular distal-third diaphyseal fractures of the humerus. A comparison of functional bracing and plate fixation. J Bone Joint Surg Am 88(11):2343–2347PubMed Jawa A, McCarty P, Doornberg J et al (2006) Extra-articular distal-third diaphyseal fractures of the humerus. A comparison of functional bracing and plate fixation. J Bone Joint Surg Am 88(11):2343–2347PubMed
8.
Zurück zum Zitat Pailhé R, Mesquida V, Rubens-Duval B, Saragaglia D (2015) Plate osteosynthesis of humeral diaphyseal fractures associated with radial palsy: twenty cases. Int Orthop 39(8):1653–7CrossRefPubMed Pailhé R, Mesquida V, Rubens-Duval B, Saragaglia D (2015) Plate osteosynthesis of humeral diaphyseal fractures associated with radial palsy: twenty cases. Int Orthop 39(8):1653–7CrossRefPubMed
9.
Zurück zum Zitat Chen X, Liu T (2015) Does emergency surgical treatment allow good nerve recovery in humeral diaphyseal fractures associated with radial palsy? Int Orthop. doi:10.1007/s00264-015-3037-7 Chen X, Liu T (2015) Does emergency surgical treatment allow good nerve recovery in humeral diaphyseal fractures associated with radial palsy? Int Orthop. doi:10.​1007/​s00264-015-3037-7
10.
Zurück zum Zitat Kim SJ, Lee SH, Son H, Lee BG (2015) Surgical result of plate osteosynthesis using a locking plate system through an anterior humeral approach for distal shaft fracture of the humerus that occurred during a throwing motion. Int Orthop. doi:10.1007/s00264-015-2895-3 PubMedCentral Kim SJ, Lee SH, Son H, Lee BG (2015) Surgical result of plate osteosynthesis using a locking plate system through an anterior humeral approach for distal shaft fracture of the humerus that occurred during a throwing motion. Int Orthop. doi:10.​1007/​s00264-015-2895-3 PubMedCentral
11.
Zurück zum Zitat McCormack RG, Brien D, Buckley RE et al (2000) Fixation of fractures of the shaft of the humerus by dynamic compression plate or intramedullary nail. A prospective, randomised trial. J Bone Joint Surg (Br) 82(3):336–339CrossRef McCormack RG, Brien D, Buckley RE et al (2000) Fixation of fractures of the shaft of the humerus by dynamic compression plate or intramedullary nail. A prospective, randomised trial. J Bone Joint Surg (Br) 82(3):336–339CrossRef
12.
Zurück zum Zitat Baltov A, Mihail R, Dian E (2013) Complications after interlocking intramedullary nailing of humeral shaft fractures. Injury 45:S9–15CrossRefPubMed Baltov A, Mihail R, Dian E (2013) Complications after interlocking intramedullary nailing of humeral shaft fractures. Injury 45:S9–15CrossRefPubMed
13.
Zurück zum Zitat Orthopaedic Trauma Association (1996) Fracture and dislocation compendium. J Orthop Trauma 10(Suppl 1):1–55 Orthopaedic Trauma Association (1996) Fracture and dislocation compendium. J Orthop Trauma 10(Suppl 1):1–55
14.
Zurück zum Zitat An Z, Zeng B, He X et al (2010) Plating osteosynthesis of mid-distal humeral shaft fractures: minimally invasive versus conventional open reduction technique. Int Orthop 34:131–135CrossRefPubMed An Z, Zeng B, He X et al (2010) Plating osteosynthesis of mid-distal humeral shaft fractures: minimally invasive versus conventional open reduction technique. Int Orthop 34:131–135CrossRefPubMed
15.
Zurück zum Zitat Concha JM, Sandoval A, Streubel PN (2010) Minimally invasive plate osteosynthesis for humeral shaft fractures: are results reproducible? Int Orthop 34:1297–1305CrossRefPubMed Concha JM, Sandoval A, Streubel PN (2010) Minimally invasive plate osteosynthesis for humeral shaft fractures: are results reproducible? Int Orthop 34:1297–1305CrossRefPubMed
16.
Zurück zum Zitat Jiang R, Luo CF, Zeng BF et al (2007) Minimally invasive plating for complex humeral shaft fractures. Arch Orthop Trauma Surg 127:531–535CrossRefPubMed Jiang R, Luo CF, Zeng BF et al (2007) Minimally invasive plating for complex humeral shaft fractures. Arch Orthop Trauma Surg 127:531–535CrossRefPubMed
17.
Zurück zum Zitat Niall DM, O’Mahony J, McElwain JP (2004) Plating of humeral shaft fractures—has the pendulum swung back? Injury 35(6):580–586CrossRefPubMed Niall DM, O’Mahony J, McElwain JP (2004) Plating of humeral shaft fractures—has the pendulum swung back? Injury 35(6):580–586CrossRefPubMed
18.
Zurück zum Zitat Changulani M, Jain UK, Keswani T (2007) Comparison of the use of the humerus intramedullary nail and dynamic compression plate for the management of diaphyseal fractures of the humerus. A randomised controlled study. Int Orthop 31(3):391–395CrossRefPubMed Changulani M, Jain UK, Keswani T (2007) Comparison of the use of the humerus intramedullary nail and dynamic compression plate for the management of diaphyseal fractures of the humerus. A randomised controlled study. Int Orthop 31(3):391–395CrossRefPubMed
19.
Zurück zum Zitat Ji F, Tong D, Tang H et al (2009) Minimally invasive percutaneous plate osteosynthesis (MIPPO) technique applied in the treatment of humeral shaft distal fractures through a lateral approach. Int Orthop 33:543–547CrossRefPubMed Ji F, Tong D, Tang H et al (2009) Minimally invasive percutaneous plate osteosynthesis (MIPPO) technique applied in the treatment of humeral shaft distal fractures through a lateral approach. Int Orthop 33:543–547CrossRefPubMed
Metadaten
Titel
Newly designed minimally invasive plating of a humerus shaft fracture; a different introduction of the plate
verfasst von
Tongjoo Lee
Jaesik Yoon
Publikationsdatum
21.01.2016
Verlag
Springer Berlin Heidelberg
Erschienen in
International Orthopaedics / Ausgabe 12/2016
Print ISSN: 0341-2695
Elektronische ISSN: 1432-5195
DOI
https://doi.org/10.1007/s00264-015-3097-8

Weitere Artikel der Ausgabe 12/2016

International Orthopaedics 12/2016 Zur Ausgabe

Arthropedia

Grundlagenwissen der Arthroskopie und Gelenkchirurgie. Erweitert durch Fallbeispiele, Videos und Abbildungen. 
» Jetzt entdecken

Update Orthopädie und Unfallchirurgie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.