Purpose

Percutaneous vertebroplasty (PVP) is a common procedure in spine surgery. Bone cement leakage is the most common complication related to this procedure. The purpose of this study was to assess the incidence and risk factors for cement leakage after PVP.

Methods

A total of 485 patients who underwent PVP between August 2003 and August 2013 were enrolled in the study. Clinical and radiological characteristics, including age, gender, diagnosis, operated level, surgical approach, type of anesthesia, volume of bone cement, fracture type, and fracture severity, were considered as potential risk factors. Cement leakage was assessed based on post-operative imaging examination. Six types of leakage were defined and risk factors for each type were analyzed.

Results

The incidence of leakage was 58.2 %. Binary logistic analysis revealed that larger volume of bone cement (P < 0.001) and higher fracture severity grade (P < 0.001) were the strongest independent risk factors. Univariate analysis and multinomial logistic analysis showed that surgical approach (P < 0.001), gender (P = 0.016), and operated level (P = 0.032) were additional risk factors for leakage. Further analysis showed that more bone cement was used in bilateral than unilateral approaches, that men had larger volumes of bone cement injected than women, and that more bone cement was injected into lumbar vertebrae than thoracic vertebrae. Therefore, these risk factors (surgical approach, gender, and operated level) could be attributed to excess bone cement usage.

Conclusions

Cement leakage is very common with PVP. Higher fracture severity grade and larger volume of bone cement were the two strongest independent risk factors for leakage.
Literatur
1.
Zurück zum Zitat Galibert P, Deramond H, Rosat P, Le Gars D (1987) Preliminary note on the treatment of vertebral angioma by percutaneous acrylic vertebroplasty. Neurochirurgie 33:166–168PubMed Galibert P, Deramond H, Rosat P, Le Gars D (1987) Preliminary note on the treatment of vertebral angioma by percutaneous acrylic vertebroplasty. Neurochirurgie 33:166–168PubMed
2.
Zurück zum Zitat McDonald RJ, Trout AT, Gray LA, Dispenzieri A, Thielen KR, Kallmes DF (2008) Vertebroplasty in multiple myeloma: outcomes in a large patient series. AJNR Am J Neuroradiol 29:642–648CrossRefPubMed McDonald RJ, Trout AT, Gray LA, Dispenzieri A, Thielen KR, Kallmes DF (2008) Vertebroplasty in multiple myeloma: outcomes in a large patient series. AJNR Am J Neuroradiol 29:642–648CrossRefPubMed
3.
Zurück zum Zitat Saracen A, Kotwica Z (2014) Treatment of multiple osteoporotic vertebral compression fractures by percutaneous cement augmentation. Int Orthop 38(11):2309–2312CrossRefPubMed Saracen A, Kotwica Z (2014) Treatment of multiple osteoporotic vertebral compression fractures by percutaneous cement augmentation. Int Orthop 38(11):2309–2312CrossRefPubMed
4.
Zurück zum Zitat Chang X, Lv YF, Chen B, Li HY, Han XB, Yang K, Zhang W, Zhou Y, Li CQ (2015) (2015) Vertebroplasty versus kyphoplasty in osteoporotic vertebral compression fracture: a meta-analysis of prospective comparative studies. Int Orthop 39(3):491–500CrossRefPubMed Chang X, Lv YF, Chen B, Li HY, Han XB, Yang K, Zhang W, Zhou Y, Li CQ (2015) (2015) Vertebroplasty versus kyphoplasty in osteoporotic vertebral compression fracture: a meta-analysis of prospective comparative studies. Int Orthop 39(3):491–500CrossRefPubMed
5.
Zurück zum Zitat Dong R, Chen L, Tang T, Gu Y, Luo Z, Shi Q, Li X, Zhou Q, Yang H (2013) Pain reduction following vertebroplasty and kyphoplasty. Int Orthop 37(1):83–87CrossRefPubMed Dong R, Chen L, Tang T, Gu Y, Luo Z, Shi Q, Li X, Zhou Q, Yang H (2013) Pain reduction following vertebroplasty and kyphoplasty. Int Orthop 37(1):83–87CrossRefPubMed
6.
Zurück zum Zitat Lee BJ, Lee SR, Yoo TY (2002) Paraplegia as a complication of percutaneous vertebroplasty with polymethylmethacrylate: a case report. Spine (Phila Pa 1976) 27:E419–E422CrossRef Lee BJ, Lee SR, Yoo TY (2002) Paraplegia as a complication of percutaneous vertebroplasty with polymethylmethacrylate: a case report. Spine (Phila Pa 1976) 27:E419–E422CrossRef
7.
Zurück zum Zitat Patel AA, Vaccaro AR, Martyak GG, Harrop JS, Albert TJ, Ludwig SC et al (2007) Neurologic deficit following percutaneous vertebral stabilization. Spine (Phila Pa 1976) 32:1728–1734CrossRef Patel AA, Vaccaro AR, Martyak GG, Harrop JS, Albert TJ, Ludwig SC et al (2007) Neurologic deficit following percutaneous vertebral stabilization. Spine (Phila Pa 1976) 32:1728–1734CrossRef
8.
Zurück zum Zitat Ryu KS, Park CK, Kim MC, Kang JK (2002) Dose-dependent epidural leakage of polymethylmethacrylate after percutaneous vertebroplasty in patients with osteoporotic vertebral compression fractures. J Neurosurg 96:56–61PubMed Ryu KS, Park CK, Kim MC, Kang JK (2002) Dose-dependent epidural leakage of polymethylmethacrylate after percutaneous vertebroplasty in patients with osteoporotic vertebral compression fractures. J Neurosurg 96:56–61PubMed
9.
Zurück zum Zitat Geraci G, Lo IG, Lo NC, Cannizzaro F, Cajozzo M, Modica G (2013) Asymptomatic bone cement pulmonary embolism after vertebroplasty: case report and literature review. Case Rep Surg 2013:591432PubMedPubMedCentral Geraci G, Lo IG, Lo NC, Cannizzaro F, Cajozzo M, Modica G (2013) Asymptomatic bone cement pulmonary embolism after vertebroplasty: case report and literature review. Case Rep Surg 2013:591432PubMedPubMedCentral
10.
Zurück zum Zitat Puri AS, Colen RR, Reddy AS, Groff MW, DiNobile D, Killoran T et al (2011) Lumbar artery pseudoaneurysm after percutaneous vertebroplasty: a unique vascular complication. J Neurosurg Spine 14:296–299CrossRefPubMed Puri AS, Colen RR, Reddy AS, Groff MW, DiNobile D, Killoran T et al (2011) Lumbar artery pseudoaneurysm after percutaneous vertebroplasty: a unique vascular complication. J Neurosurg Spine 14:296–299CrossRefPubMed
11.
Zurück zum Zitat Krueger A, Bliemel C, Zettl R, Ruchholtz S (2009) Management of pulmonary cement embolism after percutaneous vertebroplasty and kyphoplasty: a systematic review of the literature. Eur Spine J 18:1257–1265CrossRefPubMedPubMedCentral Krueger A, Bliemel C, Zettl R, Ruchholtz S (2009) Management of pulmonary cement embolism after percutaneous vertebroplasty and kyphoplasty: a systematic review of the literature. Eur Spine J 18:1257–1265CrossRefPubMedPubMedCentral
12.
Zurück zum Zitat Muijs SP, Nieuwenhuijse MJ, Van Erkel AR, Dijkstra PD (2009) Percutaneous vertebroplasty for the treatment of osteoporotic vertebral compression fractures: evaluation after 36 months. J Bone Joint Surg (Br) 91:379–384CrossRef Muijs SP, Nieuwenhuijse MJ, Van Erkel AR, Dijkstra PD (2009) Percutaneous vertebroplasty for the treatment of osteoporotic vertebral compression fractures: evaluation after 36 months. J Bone Joint Surg (Br) 91:379–384CrossRef
13.
Zurück zum Zitat Schmidt R, Cakir B, Mattes T, Wegener M, Puhl W, Richter M (2005) Cement leakage during vertebroplasty: an underestimated problem? Eur Spine J 14:466–473CrossRefPubMedPubMedCentral Schmidt R, Cakir B, Mattes T, Wegener M, Puhl W, Richter M (2005) Cement leakage during vertebroplasty: an underestimated problem? Eur Spine J 14:466–473CrossRefPubMedPubMedCentral
14.
Zurück zum Zitat Genant HK, Wu CY, van Kuijk C, Nevitt MC (1993) Vertebral fracture assessment using a semiquantitative technique. J Bone Miner Res 8:1137–1148CrossRefPubMed Genant HK, Wu CY, van Kuijk C, Nevitt MC (1993) Vertebral fracture assessment using a semiquantitative technique. J Bone Miner Res 8:1137–1148CrossRefPubMed
15.
Zurück zum Zitat Wang HL, Jiang ZG, Wang ZG, Zhu J, Zhao HT (2009) Analysis of the complication and prevention on treatment of osteoporotic vertebral compressive fractures by percutaneous vertebroplasty (PVP). Zhongguo Gu Shang 22:783–784PubMed Wang HL, Jiang ZG, Wang ZG, Zhu J, Zhao HT (2009) Analysis of the complication and prevention on treatment of osteoporotic vertebral compressive fractures by percutaneous vertebroplasty (PVP). Zhongguo Gu Shang 22:783–784PubMed
16.
Zurück zum Zitat Yeom JS, Kim WJ, Choy WS, Lee CK, Chang BS, Kang JW (2003) Leakage of cement in percutaneous transpedicular vertebroplasty for painful osteoporotic compression fractures. J Bone Joint Surg (Br) 85:83–89CrossRef Yeom JS, Kim WJ, Choy WS, Lee CK, Chang BS, Kang JW (2003) Leakage of cement in percutaneous transpedicular vertebroplasty for painful osteoporotic compression fractures. J Bone Joint Surg (Br) 85:83–89CrossRef
17.
Zurück zum Zitat Fribourg D, Tang C, Sra P, Delamarter R, Bae H (2004) Incidence of subsequent vertebral fracture after kyphoplasty. Spine (Phila Pa 1976) 29(2270–6):2277 Fribourg D, Tang C, Sra P, Delamarter R, Bae H (2004) Incidence of subsequent vertebral fracture after kyphoplasty. Spine (Phila Pa 1976) 29(2270–6):2277
18.
Zurück zum Zitat Lee MJ, Dumonski M, Cahill P, Stanley T, Park D, Singh K (2009) Percutaneous treatment of vertebral compression fractures: a meta-analysis of complications. Spine (Phila Pa 1976) 34:1228–1232CrossRef Lee MJ, Dumonski M, Cahill P, Stanley T, Park D, Singh K (2009) Percutaneous treatment of vertebral compression fractures: a meta-analysis of complications. Spine (Phila Pa 1976) 34:1228–1232CrossRef
19.
Zurück zum Zitat Nieuwenhuijse MJ, Bollen L, van Erkel AR, Dijkstra PD (2012) Optimal intravertebral cement volume in percutaneous vertebroplasty for painful osteoporotic vertebral compression fractures. Spine (Phila Pa 1976) 37:1747–1755CrossRef Nieuwenhuijse MJ, Bollen L, van Erkel AR, Dijkstra PD (2012) Optimal intravertebral cement volume in percutaneous vertebroplasty for painful osteoporotic vertebral compression fractures. Spine (Phila Pa 1976) 37:1747–1755CrossRef
20.
Zurück zum Zitat Kruger A, Baroud G, Noriega D, Figiel J, Dorschel C, Ruchholtz S et al (2013) Height restoration and maintenance after treating unstable osteoporotic vertebral compression fractures by cement augmentation is dependent on the cement volume used. Clin Biomech (Bristol, Avon) 28:725–730CrossRef Kruger A, Baroud G, Noriega D, Figiel J, Dorschel C, Ruchholtz S et al (2013) Height restoration and maintenance after treating unstable osteoporotic vertebral compression fractures by cement augmentation is dependent on the cement volume used. Clin Biomech (Bristol, Avon) 28:725–730CrossRef
21.
Zurück zum Zitat Nieuwenhuijse MJ, Van Erkel AR, Dijkstra PD (2011) Cement leakage in percutaneous vertebroplasty for osteoporotic vertebral compression fractures: identification of risk factors. Spine J 11(9):839–848CrossRefPubMed Nieuwenhuijse MJ, Van Erkel AR, Dijkstra PD (2011) Cement leakage in percutaneous vertebroplasty for osteoporotic vertebral compression fractures: identification of risk factors. Spine J 11(9):839–848CrossRefPubMed
22.
Zurück zum Zitat Nieuwenhuijse MJ, Muijs SP, van Erkel AR, Dijkstra SP (2010) A clinical comparative study on low versus medium viscosity polymethylmetacrylate bone cement in percutaneous vertebroplasty: viscosity associated with cement leakage. Spine (Phila Pa 1976) 35:E1037–E1044CrossRef Nieuwenhuijse MJ, Muijs SP, van Erkel AR, Dijkstra SP (2010) A clinical comparative study on low versus medium viscosity polymethylmetacrylate bone cement in percutaneous vertebroplasty: viscosity associated with cement leakage. Spine (Phila Pa 1976) 35:E1037–E1044CrossRef
23.
Zurück zum Zitat Limthongkul W, Karaikovic EE, Savage JW, Markovic A (2010) Volumetric analysis of thoracic and lumbar vertebral bodies. Spine J 10:153–158CrossRefPubMed Limthongkul W, Karaikovic EE, Savage JW, Markovic A (2010) Volumetric analysis of thoracic and lumbar vertebral bodies. Spine J 10:153–158CrossRefPubMed
24.
Zurück zum Zitat Baroud G, Crookshank M, Bohner M (2006) High-viscosity cement significantly enhances uniformity of cement filling in vertebroplasty: an experimental model and study on cement leakage. Spine (Phila Pa 1976) 31:2562–2568CrossRef Baroud G, Crookshank M, Bohner M (2006) High-viscosity cement significantly enhances uniformity of cement filling in vertebroplasty: an experimental model and study on cement leakage. Spine (Phila Pa 1976) 31:2562–2568CrossRef
25.
Zurück zum Zitat Bohner M, Gasser B, Baroud G, Heini P (2003) Theoretical and experimental model to describe the injection of a polymethylmethacrylate cement into a porous structure. Biomaterials 24:2721–2730CrossRefPubMed Bohner M, Gasser B, Baroud G, Heini P (2003) Theoretical and experimental model to describe the injection of a polymethylmethacrylate cement into a porous structure. Biomaterials 24:2721–2730CrossRefPubMed
26.
Zurück zum Zitat Loeffel M, Ferguson SJ, Nolte LP, Kowal JH (2008) Vertebroplasty: experimental characterization of polymethylmethacrylate bone cement spreading as a function of viscosity, bone porosity, and flow rate. Spine (Phila Pa 1976) 33:1352–1359CrossRef Loeffel M, Ferguson SJ, Nolte LP, Kowal JH (2008) Vertebroplasty: experimental characterization of polymethylmethacrylate bone cement spreading as a function of viscosity, bone porosity, and flow rate. Spine (Phila Pa 1976) 33:1352–1359CrossRef
27.
Zurück zum Zitat Tanigawa N, Komemushi A, Kariya S, Kojima H, Shomura Y, Omura N et al (2007) Relationship between cement distribution pattern and new compression fracture after percutaneous vertebroplasty. AJR Am J Roentgenol 189:W348–W352CrossRefPubMed Tanigawa N, Komemushi A, Kariya S, Kojima H, Shomura Y, Omura N et al (2007) Relationship between cement distribution pattern and new compression fracture after percutaneous vertebroplasty. AJR Am J Roentgenol 189:W348–W352CrossRefPubMed
28.
Zurück zum Zitat Gstottner M, Angerer A, Rosiek R, Bach CM (2012) Quantitative volumetry of cement leakage in viscosity-controlled vertebroplasty. J Spinal Disord Tech 25:E150–E154CrossRefPubMed Gstottner M, Angerer A, Rosiek R, Bach CM (2012) Quantitative volumetry of cement leakage in viscosity-controlled vertebroplasty. J Spinal Disord Tech 25:E150–E154CrossRefPubMed
Metadaten
Titel
Risk factors for bone cement leakage in percutaneous vertebroplasty: a retrospective study of four hundred and eighty five patients
verfasst von
Si-Yuan Zhu
Zhao-Ming Zhong
Qian Wu
Jian-Ting Chen
Publikationsdatum
12.01.2016
Verlag
Springer Berlin Heidelberg
Erschienen in
International Orthopaedics / Ausgabe 6/2016
Print ISSN: 0341-2695
Elektronische ISSN: 1432-5195
DOI
https://doi.org/10.1007/s00264-015-3102-2

Weitere Artikel der Ausgabe 6/2016

International Orthopaedics 6/2016 Zur Ausgabe

Arthropedia

Grundlagenwissen der Arthroskopie und Gelenkchirurgie. Erweitert durch Fallbeispiele, Videos und Abbildungen. 
» Jetzt entdecken

Update Orthopädie und Unfallchirurgie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.