Skip to main content
Erschienen in: International Orthopaedics 9/2016

23.01.2016 | Original Paper

Pre-operative radiological measurement of femoral rotation for prosthetic positioning in total knee arthroplasty

verfasst von: Liliana Savin, Paul Botez, Dan Mihailescu, Vlad Predescu, Carmen Grierosu

Erschienen in: International Orthopaedics | Ausgabe 9/2016

Einloggen, um Zugang zu erhalten

Abstract

Purpose

This study outlines the benefits of the seated view radiograph of the knee in evaluation of the pre-operative individual distal femoral torsion (DFT) and for the follow-up of the post-operative rotational positioning of the femoral component in total knee arthroplasty.

Methods

Study on 20 patients who underwent total knee arthroplasty and the correlation between the DFT measured before surgery with this radiology view, the intra-operative external rotation (ER) necessary for the parallel positioning of the femoral component with the transepicondylar axis (TEA) and the post-operative femoral rotational alignment of the prosthesis on the same view.

Results

In 90 % of cases the values of internal DFT were between −10 and −80, while the mean value of the internal rotation (IR) was −4.450. The mean value of the ER applied to the posterior bone resection was 4.250 (00–70), showing a statistically significant correlation between the pre-operative measurement and the intra-operative one of the posterior condylar angle (PCA) (r = 0.890, p = 0.000). Residual internal femoral malrotation has been identified in four cases, its mean value being 0.40. In three patients the pre-operative value of the PCA was higher than the intra-operative one and an internal malrotation of the post-operative femoral component was observed.

Conclusions

The results are encouraging for the further use of this pre-operative view with the premises of increasing the accuracy of prosthetic positioning and reducing the mechanical complications.
Literatur
1.
Zurück zum Zitat Blumenfeld TJ (2013) CORR insights (R): is TKA using patient-specific instruments comparable to conventional TKA? A randomized controlled study of one system. Clin Orthop Relat Res 471(12):3996–3997CrossRefPubMedPubMedCentral Blumenfeld TJ (2013) CORR insights (R): is TKA using patient-specific instruments comparable to conventional TKA? A randomized controlled study of one system. Clin Orthop Relat Res 471(12):3996–3997CrossRefPubMedPubMedCentral
2.
Zurück zum Zitat Barrett WP, Mason JB, Moskal JT, Dalury DF, Oliashirazi A, Fisher DA (2011) Comparison of radiographic alignment of imageless computer assisted surgery vs conventional instrumentation in primary total knee arthroplasty. J Arthroplasty 26(8):1273–1284CrossRefPubMed Barrett WP, Mason JB, Moskal JT, Dalury DF, Oliashirazi A, Fisher DA (2011) Comparison of radiographic alignment of imageless computer assisted surgery vs conventional instrumentation in primary total knee arthroplasty. J Arthroplasty 26(8):1273–1284CrossRefPubMed
3.
Zurück zum Zitat D’Lima DD, Chen PC, Colwell CW Jr (2001) Polyethylene contact stresses, articular congruity, and knee alignment. Clin Orthop Relat Res 392(11):232–238CrossRefPubMed D’Lima DD, Chen PC, Colwell CW Jr (2001) Polyethylene contact stresses, articular congruity, and knee alignment. Clin Orthop Relat Res 392(11):232–238CrossRefPubMed
4.
Zurück zum Zitat Kotela A, Kotela I (2014) Patient-specific computed tomography based instrumentation in total knee arthroplasty: a prospective randomized controlled study. Int Orthop 38(10):2099–2107CrossRefPubMed Kotela A, Kotela I (2014) Patient-specific computed tomography based instrumentation in total knee arthroplasty: a prospective randomized controlled study. Int Orthop 38(10):2099–2107CrossRefPubMed
5.
Zurück zum Zitat Nagamine R, White SE, McCarthy DS, Whiteside LA (1995) Effect of rotational malposition of the femoral component on knee stability kinematics after total knee arthroplasty. J Arthroplasty 10(3):265–270CrossRefPubMed Nagamine R, White SE, McCarthy DS, Whiteside LA (1995) Effect of rotational malposition of the femoral component on knee stability kinematics after total knee arthroplasty. J Arthroplasty 10(3):265–270CrossRefPubMed
6.
Zurück zum Zitat Insall JN, Scuderi GR, Komistek RD, Math K, Dennis DA, Anderson DT (2002) Correlation between condylar lift-off and femoral component alignment. Clin Orthop Relat Res 403(10):143–152CrossRefPubMed Insall JN, Scuderi GR, Komistek RD, Math K, Dennis DA, Anderson DT (2002) Correlation between condylar lift-off and femoral component alignment. Clin Orthop Relat Res 403(10):143–152CrossRefPubMed
7.
Zurück zum Zitat Skolnick MD, Coventry MB, Ilstrup DM (1976) Geometric total knee arthroplasty. A two-year follow-up study. J Bone Joint Surg 58(6):749–753PubMed Skolnick MD, Coventry MB, Ilstrup DM (1976) Geometric total knee arthroplasty. A two-year follow-up study. J Bone Joint Surg 58(6):749–753PubMed
8.
Zurück zum Zitat Berger RA, Rubash HE, Seel MJ, Warren HT, Crosset LS (1993) Determining the rotational alignment of the femoral component in total knee arthroplasty using the epicondylar axis. Clin Orthop Relat Res 286(1):40–47PubMed Berger RA, Rubash HE, Seel MJ, Warren HT, Crosset LS (1993) Determining the rotational alignment of the femoral component in total knee arthroplasty using the epicondylar axis. Clin Orthop Relat Res 286(1):40–47PubMed
9.
Zurück zum Zitat Yoshioka Y, Siu D, Cooke TD (1987) The anatomy and functional axes of the femur. J Bone Joint Surg 69(6):873–880PubMed Yoshioka Y, Siu D, Cooke TD (1987) The anatomy and functional axes of the femur. J Bone Joint Surg 69(6):873–880PubMed
10.
Zurück zum Zitat Viel T, Casin C, Ducellier F, Steiger V, Bigorre N, Bizot P (2013) Is radiographic measurement of distal femoral torsion reliable? Orthop Traumatol Surg Res 99(5):517–522CrossRefPubMed Viel T, Casin C, Ducellier F, Steiger V, Bigorre N, Bizot P (2013) Is radiographic measurement of distal femoral torsion reliable? Orthop Traumatol Surg Res 99(5):517–522CrossRefPubMed
11.
Zurück zum Zitat Victor J (2009) Rotational alignment of the distal femur: a literature review. Orthop Traumatol Surg Res 95(5):365–372CrossRefPubMed Victor J (2009) Rotational alignment of the distal femur: a literature review. Orthop Traumatol Surg Res 95(5):365–372CrossRefPubMed
12.
Zurück zum Zitat Nagamine R, Miura H, Inoue Y et al (1998) Reliability of the anteroposterior axis and the posterior condylar axis for determining rotational alignment of the femoral component in total knee arthroplasty. J Orthop Sci 3(4):194–198CrossRefPubMed Nagamine R, Miura H, Inoue Y et al (1998) Reliability of the anteroposterior axis and the posterior condylar axis for determining rotational alignment of the femoral component in total knee arthroplasty. J Orthop Sci 3(4):194–198CrossRefPubMed
13.
Zurück zum Zitat Griffin FM, Math K, Scuderi GR et al (2000) Anatomy of the epicondyles of the distal femur: MRI analysis of normal knees. J Arthroplasty 15(3):354–359CrossRefPubMed Griffin FM, Math K, Scuderi GR et al (2000) Anatomy of the epicondyles of the distal femur: MRI analysis of normal knees. J Arthroplasty 15(3):354–359CrossRefPubMed
14.
Zurück zum Zitat Akagi M, Yamashita E, Nakagawa T, Asano T, Nakamura T (2001) Relationship between frontal knee alignment and reference axes in the distal femur. Clin Orthop Relat Res 388(7):147–156CrossRefPubMed Akagi M, Yamashita E, Nakagawa T, Asano T, Nakamura T (2001) Relationship between frontal knee alignment and reference axes in the distal femur. Clin Orthop Relat Res 388(7):147–156CrossRefPubMed
15.
Zurück zum Zitat Yoshino N, Takai S, Ohtsuki Y, Hirasawa Y (2001) Computed tomography measurement of the surgical and clinical transepicondylar axis of the distal femur in osteoarthritic knees. J Arthroplasty 16(4):493–497CrossRefPubMed Yoshino N, Takai S, Ohtsuki Y, Hirasawa Y (2001) Computed tomography measurement of the surgical and clinical transepicondylar axis of the distal femur in osteoarthritic knees. J Arthroplasty 16(4):493–497CrossRefPubMed
16.
Zurück zum Zitat Takai S, Yoshino N, Isshiki T, Hirasawa Y (2003) Kneeling view: a new roentgenographic technique to assess rotational deformity and alignment of the distal femur. J Arthroplasty 18(4):478–483CrossRefPubMed Takai S, Yoshino N, Isshiki T, Hirasawa Y (2003) Kneeling view: a new roentgenographic technique to assess rotational deformity and alignment of the distal femur. J Arthroplasty 18(4):478–483CrossRefPubMed
17.
Zurück zum Zitat Kanekasu K, Kondo M, Kadoya Y (2005) Axial radiography of the distal femur to assess rotational alignment in total knee arthroplasty. Clin Orthop Relat Res 434(5):193–197CrossRefPubMed Kanekasu K, Kondo M, Kadoya Y (2005) Axial radiography of the distal femur to assess rotational alignment in total knee arthroplasty. Clin Orthop Relat Res 434(5):193–197CrossRefPubMed
18.
Zurück zum Zitat Akagi M, Matsusue Y, Mata T et al (1999) Effect of rotational alignment on patellar tracking in total knee arthroplasty. Clin Orthop Relat Res 366(9):155–163CrossRefPubMed Akagi M, Matsusue Y, Mata T et al (1999) Effect of rotational alignment on patellar tracking in total knee arthroplasty. Clin Orthop Relat Res 366(9):155–163CrossRefPubMed
19.
Zurück zum Zitat Anouchi YS, Whiteside LA, Kaiser AD, Milliano MT (1993) The effects of axial rotational alignment of the femoral component on knee stability and patellar tracking in total knee arthroplasty demonstrated on autopsy specimens. Clin Orthop Relat Res 287(2):170–177PubMed Anouchi YS, Whiteside LA, Kaiser AD, Milliano MT (1993) The effects of axial rotational alignment of the femoral component on knee stability and patellar tracking in total knee arthroplasty demonstrated on autopsy specimens. Clin Orthop Relat Res 287(2):170–177PubMed
20.
Zurück zum Zitat Moreland JR, Bassett LW, Hanker GJ (1987) Radiographic analysis of the axial alignment of the lower extremity. J Bone Joint Surg Am 69(5):745–749PubMed Moreland JR, Bassett LW, Hanker GJ (1987) Radiographic analysis of the axial alignment of the lower extremity. J Bone Joint Surg Am 69(5):745–749PubMed
21.
Zurück zum Zitat Olcott CW, Scott RD (1999) The ranawat award. Femoral component rotation during total knee arthroplasty. Clin Orthop Relat Res 367(10):39–42PubMed Olcott CW, Scott RD (1999) The ranawat award. Femoral component rotation during total knee arthroplasty. Clin Orthop Relat Res 367(10):39–42PubMed
22.
Zurück zum Zitat Hananouchi T (2015) Sagittal gap balancing with the concept of a single radius femoral component in posterior cruciate sacrificing total knee arthroplasty with patient-specific instrumentation. Int Orthop 39(4):659–665CrossRefPubMed Hananouchi T (2015) Sagittal gap balancing with the concept of a single radius femoral component in posterior cruciate sacrificing total knee arthroplasty with patient-specific instrumentation. Int Orthop 39(4):659–665CrossRefPubMed
23.
Zurück zum Zitat Jerosch J, Peuker E, Philipps B, Filler T (2002) Interindividual reproducibility in perioperative rotational alignment of femoral components in knee prosthetic surgery using the transepicondylar axis. Knee Surg Sports Traumatol Arthrosc 10(3):194–197CrossRef Jerosch J, Peuker E, Philipps B, Filler T (2002) Interindividual reproducibility in perioperative rotational alignment of femoral components in knee prosthetic surgery using the transepicondylar axis. Knee Surg Sports Traumatol Arthrosc 10(3):194–197CrossRef
24.
Zurück zum Zitat Kinzel V, Ledger M, Shakespeare D (2005) Can the epicondylar axis be defined accurately in total knee arthroplasty? Knee 12(4):293–296CrossRefPubMed Kinzel V, Ledger M, Shakespeare D (2005) Can the epicondylar axis be defined accurately in total knee arthroplasty? Knee 12(4):293–296CrossRefPubMed
25.
Zurück zum Zitat Mantas JP, Bloebaum RD, Skedros JG, Hofmann AA (1992) Implications of reference axes used for rotational alignment of the femoral component in primary and revision knee arthroplasty. J Arthroplasty 7(4):531–535CrossRefPubMed Mantas JP, Bloebaum RD, Skedros JG, Hofmann AA (1992) Implications of reference axes used for rotational alignment of the femoral component in primary and revision knee arthroplasty. J Arthroplasty 7(4):531–535CrossRefPubMed
26.
Zurück zum Zitat Griffin FM, Insall JN, Scuderi GR (1998) The posterior condylar angle in osteoarthritic knees. J Arthroplasty 13(7):812–815CrossRefPubMed Griffin FM, Insall JN, Scuderi GR (1998) The posterior condylar angle in osteoarthritic knees. J Arthroplasty 13(7):812–815CrossRefPubMed
27.
Zurück zum Zitat Arima J, Whiteside LA, McCarthy DS, White S (1995) Femoral rotational alignment, based on the anteroposterior axis, in total knee arthroplasty in a valgus knee. J Bone Joint Surg 77(9):1331–1334PubMed Arima J, Whiteside LA, McCarthy DS, White S (1995) Femoral rotational alignment, based on the anteroposterior axis, in total knee arthroplasty in a valgus knee. J Bone Joint Surg 77(9):1331–1334PubMed
28.
Zurück zum Zitat Nowakowski AM, Kamphausen M, Pagenstert G, Valderrabano V, Müller-Gerbl M (2014) Influence of tibial slope on extension and flexion gaps in total knee arthroplasty: increasing the tibial slope affects both gaps. Int Orthop 38(10):2071–2077CrossRefPubMed Nowakowski AM, Kamphausen M, Pagenstert G, Valderrabano V, Müller-Gerbl M (2014) Influence of tibial slope on extension and flexion gaps in total knee arthroplasty: increasing the tibial slope affects both gaps. Int Orthop 38(10):2071–2077CrossRefPubMed
Metadaten
Titel
Pre-operative radiological measurement of femoral rotation for prosthetic positioning in total knee arthroplasty
verfasst von
Liliana Savin
Paul Botez
Dan Mihailescu
Vlad Predescu
Carmen Grierosu
Publikationsdatum
23.01.2016
Verlag
Springer Berlin Heidelberg
Erschienen in
International Orthopaedics / Ausgabe 9/2016
Print ISSN: 0341-2695
Elektronische ISSN: 1432-5195
DOI
https://doi.org/10.1007/s00264-015-3110-2

Weitere Artikel der Ausgabe 9/2016

International Orthopaedics 9/2016 Zur Ausgabe

Arthropedia

Grundlagenwissen der Arthroskopie und Gelenkchirurgie. Erweitert durch Fallbeispiele, Videos und Abbildungen. 
» Jetzt entdecken

Update Orthopädie und Unfallchirurgie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.