Skip to main content
Erschienen in: International Orthopaedics 5/2018

02.12.2017 | Original Paper

Comparison of dual mobility cup and other surgical construts used for three hundred and sixty two first time hip revisions due to recurrent dislocations: five year results from Lithuanian arthroplasty register

verfasst von: Justinas Stucinskas, Tomas Kalvaitis, Alfredas Smailys, Otto Robertsson, Sarunas Tarasevicius

Erschienen in: International Orthopaedics | Ausgabe 5/2018

Einloggen, um Zugang zu erhalten

Abstract

Purpose

Recently, there has been increasing interest in the use of dual mobility systems in the treatment of hip instability. The aim of this study was to investigate the re-revision rate of dual mobility cup compared to different surgical concepts when used for first-time hip revisions due to recurrent dislocations.

Methods

The data were derived from the Lithuanian Arthroplasty Register. For survival analysis, we used both re-revision for all reasons and for dislocations as an end-point. Cox proportional hazards models were used to analyze the influence of various covariates (age, gender, and implant concept).

Results

A total of 1388 revisions were recorded from 2011 to 2015, of which 362 were performed due to recurrent dislocation. Of the revisions, 247 were performed using dual mobility cups, while 115 were performed using a variety of other surgical constructs including constrained acetabular cups, conventional cups, femoral head exchanges, stem exchanges or anti-luxation rings. There were 27 re-revisions of which 15 were for additional dislocations. There were only 2% re-revisions due to dislocation with dual mobility vs 9% when using other surgical constructs. Cox regression adjusting for age and gender showed that in the short-term, dual mobility cup had a lower risk of revision due to dislocation as well as for all reasons compared to the other surgical constructs.

Conclusion

In revision of total hip arthroplasties for dislocation, significantly lower short-term re-revision rate was observed for patients revised with dual mobility cup.
Literatur
1.
Zurück zum Zitat Parvizi J, Picinic E, Sharkey PF (2008) Revision total hip arthroplasty for instability: surgical techniques and principles. J Bone Joint Surg Am 90(5):1134–1142PubMed Parvizi J, Picinic E, Sharkey PF (2008) Revision total hip arthroplasty for instability: surgical techniques and principles. J Bone Joint Surg Am 90(5):1134–1142PubMed
2.
Zurück zum Zitat Enocson A, Hedbeck CJ, Tidermark J, Pettersson H, Ponzer S, Lapidus LJ (2009) Dislocation of total hip replacement in patients with fractures of the femoral neck. Acta Orthop 80:184–189CrossRefPubMedPubMedCentral Enocson A, Hedbeck CJ, Tidermark J, Pettersson H, Ponzer S, Lapidus LJ (2009) Dislocation of total hip replacement in patients with fractures of the femoral neck. Acta Orthop 80:184–189CrossRefPubMedPubMedCentral
3.
Zurück zum Zitat Zagra L, Caboni E (2017) Total hip arthroplasty instability treatment without dual mobility cups: brief overview and experience of other options. Int Orthop 41(3):661–668CrossRefPubMed Zagra L, Caboni E (2017) Total hip arthroplasty instability treatment without dual mobility cups: brief overview and experience of other options. Int Orthop 41(3):661–668CrossRefPubMed
4.
Zurück zum Zitat Bousquet G, Argenson C, Godeneche JL, Cisterne JP, Gazielly DF, Girardin P, Debiesse JL (1986) Recovery after aseptic loosening of cemented total hip arthroplasties with Bousquet’s cementless prosthesis. Apropos of 136 cases. Rev Chir Orthop Reparatrice Appar Mot 72(2):70–74PubMed Bousquet G, Argenson C, Godeneche JL, Cisterne JP, Gazielly DF, Girardin P, Debiesse JL (1986) Recovery after aseptic loosening of cemented total hip arthroplasties with Bousquet’s cementless prosthesis. Apropos of 136 cases. Rev Chir Orthop Reparatrice Appar Mot 72(2):70–74PubMed
6.
Zurück zum Zitat Philippot R, Adam P, Reckhaus M, Delangle F, Verdot F, Curvale G, Farizon F (2009) Prevention of dislocation in total hip revision surgery using a dual mobility design. Orthop Traumatol Surg Res 95:407CrossRefPubMed Philippot R, Adam P, Reckhaus M, Delangle F, Verdot F, Curvale G, Farizon F (2009) Prevention of dislocation in total hip revision surgery using a dual mobility design. Orthop Traumatol Surg Res 95:407CrossRefPubMed
7.
Zurück zum Zitat Guyen O, Pibarot V, Vaz G, Chevillotte C, Béjui-Hugues J (2009) Use of a dual mobility socket to manage total hip arthroplasty instability. Clin Orthop Relat Res 467:465CrossRefPubMed Guyen O, Pibarot V, Vaz G, Chevillotte C, Béjui-Hugues J (2009) Use of a dual mobility socket to manage total hip arthroplasty instability. Clin Orthop Relat Res 467:465CrossRefPubMed
8.
Zurück zum Zitat Massin P, Besnier L (2010) Acetabular revision of total hip arthroplasty using a press-fit dual mobility cup. Orthop Traumatol Surg Res 96:9CrossRefPubMed Massin P, Besnier L (2010) Acetabular revision of total hip arthroplasty using a press-fit dual mobility cup. Orthop Traumatol Surg Res 96:9CrossRefPubMed
9.
Zurück zum Zitat Civinini R, Carulli C, Matassi F, Nistri L, Innocenti M (2012) A dual-mobility cup reduces risk of dislocation in isolated acetabular revisions. Clin Orthop Relat Res 470:3542CrossRefPubMedPubMedCentral Civinini R, Carulli C, Matassi F, Nistri L, Innocenti M (2012) A dual-mobility cup reduces risk of dislocation in isolated acetabular revisions. Clin Orthop Relat Res 470:3542CrossRefPubMedPubMedCentral
10.
Zurück zum Zitat Hailer NP, Weiss RJ, Stark A, Kärrholm J (2012) Dual-mobility cups for revision to instability are associated with a low rate of re-revisions due to dislocation. 228 patients from the Swedish hip Arthroplasty register. Acta Orthop 83:566CrossRefPubMedPubMedCentral Hailer NP, Weiss RJ, Stark A, Kärrholm J (2012) Dual-mobility cups for revision to instability are associated with a low rate of re-revisions due to dislocation. 228 patients from the Swedish hip Arthroplasty register. Acta Orthop 83:566CrossRefPubMedPubMedCentral
11.
Zurück zum Zitat Vasukutty NL, Middleton RG, Matthews EC, Young PS, Uzoigwe CE, Minhas TH (2012) The double-mobility acetabular component in revision total hip replacement. The United Kingdom experience. J Bone Joint Surg Br 94:603–608 Vasukutty NL, Middleton RG, Matthews EC, Young PS, Uzoigwe CE, Minhas TH (2012) The double-mobility acetabular component in revision total hip replacement. The United Kingdom experience. J Bone Joint Surg Br 94:603–608
12.
Zurück zum Zitat Wegrzyn J, Tebaa E, Jacquel A, Carret JP, Béjui-Hugues J, Pibarot V (2015) Can dual mobility cups prevent dislocation in all situations after revision Total hip Arthroplasty? J Arthroplast 30(4):631–640CrossRef Wegrzyn J, Tebaa E, Jacquel A, Carret JP, Béjui-Hugues J, Pibarot V (2015) Can dual mobility cups prevent dislocation in all situations after revision Total hip Arthroplasty? J Arthroplast 30(4):631–640CrossRef
13.
Zurück zum Zitat Caton JH, Ferreira A (2017) Dual-mobility cup: a new French revolution. Int Orthop 41(3):433–437CrossRefPubMed Caton JH, Ferreira A (2017) Dual-mobility cup: a new French revolution. Int Orthop 41(3):433–437CrossRefPubMed
14.
Zurück zum Zitat Prudhon JL, Steffann F, Ferreira A, Verdier R, Aslanian T, Caton J (2014) Cementless dual-mobility cup in total hip arthroplasty revision. Int Orthop 38(12):2463–2468CrossRefPubMed Prudhon JL, Steffann F, Ferreira A, Verdier R, Aslanian T, Caton J (2014) Cementless dual-mobility cup in total hip arthroplasty revision. Int Orthop 38(12):2463–2468CrossRefPubMed
15.
Zurück zum Zitat Hamadouche M, Ropars M, Rodaix C, Musset T, Gaucher F, Biau D, Courpied JP, Huten D (2017) Five to thirteen year results of a cemented dual mobility socket to treat recurrent dislocation. Int Orthop 41(3):513–519CrossRefPubMed Hamadouche M, Ropars M, Rodaix C, Musset T, Gaucher F, Biau D, Courpied JP, Huten D (2017) Five to thirteen year results of a cemented dual mobility socket to treat recurrent dislocation. Int Orthop 41(3):513–519CrossRefPubMed
16.
Zurück zum Zitat Viste A, Desmarchelier R, Fessy MH (2017) Dual mobility cups in revision total hip arthroplasty. Int Orthop 41(3):535–542CrossRefPubMed Viste A, Desmarchelier R, Fessy MH (2017) Dual mobility cups in revision total hip arthroplasty. Int Orthop 41(3):535–542CrossRefPubMed
17.
Zurück zum Zitat Mohaddes M, Cnudde P, Rolfson O, Wall A, Kärrholm J (2017) Use of dual-mobility cup in revision hip arthroplasty reduces the risk for further dislocation: analysis of seven hundred and ninety one first-time revisions performed due to dislocation, reported to the Swedish hip Arthroplasty register. Int Orthop 41(3):583–588CrossRefPubMed Mohaddes M, Cnudde P, Rolfson O, Wall A, Kärrholm J (2017) Use of dual-mobility cup in revision hip arthroplasty reduces the risk for further dislocation: analysis of seven hundred and ninety one first-time revisions performed due to dislocation, reported to the Swedish hip Arthroplasty register. Int Orthop 41(3):583–588CrossRefPubMed
18.
Zurück zum Zitat Sadoghi P, Leithner A, Labek G (2013) Overcoming boundaries of worldwide joint arthroplasty registers: the European Arthroplasty register minimal dataset. J Arthroplast 28(8):1327–1328CrossRef Sadoghi P, Leithner A, Labek G (2013) Overcoming boundaries of worldwide joint arthroplasty registers: the European Arthroplasty register minimal dataset. J Arthroplast 28(8):1327–1328CrossRef
19.
Zurück zum Zitat Tarasevičius S, Čebatorius A, Valavičienė R, Stučinskas J, Leonas L, Robertsson O (2014) First outcome results after total knee and hip replacement from the Lithuanian arthroplasty register. Medicina (Kaunas) 50(2):87–91CrossRef Tarasevičius S, Čebatorius A, Valavičienė R, Stučinskas J, Leonas L, Robertsson O (2014) First outcome results after total knee and hip replacement from the Lithuanian arthroplasty register. Medicina (Kaunas) 50(2):87–91CrossRef
20.
Zurück zum Zitat Dorey F, Nasser S, Amstutz H (1993) The need for confidence intervals in the presentation of orthopaedic data. J Bone Joint Surg Am 75(12):1844–1852CrossRefPubMed Dorey F, Nasser S, Amstutz H (1993) The need for confidence intervals in the presentation of orthopaedic data. J Bone Joint Surg Am 75(12):1844–1852CrossRefPubMed
21.
Zurück zum Zitat StataCorp (2013) Stata statistical software: release 13. StataCorp LP, College Station StataCorp (2013) Stata statistical software: release 13. StataCorp LP, College Station
22.
Zurück zum Zitat Saragaglia D, Ruatti S, Refaie R (2013) Relevance of a press-fit dual mobility cup to deal with recurrent dislocation of conventional total hip arthroplasty: a 29-case series. Eur J Orthop Surg Traumatol 23(4):431–436CrossRefPubMed Saragaglia D, Ruatti S, Refaie R (2013) Relevance of a press-fit dual mobility cup to deal with recurrent dislocation of conventional total hip arthroplasty: a 29-case series. Eur J Orthop Surg Traumatol 23(4):431–436CrossRefPubMed
23.
Zurück zum Zitat Leiber-Wackenheim F, Brunschweiler B, Ehlinger M, Gabrion A, Mertl P (2011) Treatment of recurrent THR dislocation using of a cementless dual-mobility cup: a 59 cases series with a mean 8 years’ follow-up. Orthop Traumatol Surg Res 97(1):8–13CrossRefPubMed Leiber-Wackenheim F, Brunschweiler B, Ehlinger M, Gabrion A, Mertl P (2011) Treatment of recurrent THR dislocation using of a cementless dual-mobility cup: a 59 cases series with a mean 8 years’ follow-up. Orthop Traumatol Surg Res 97(1):8–13CrossRefPubMed
24.
Zurück zum Zitat Stedman RC, Lim D, Husain A, Courtney PM, Nelson CL (2016) Single-component revisions are associated with dislocation after revision total hip arthroplasty at intermediate-term follow-up. Hip Int 26(3):233–236CrossRefPubMed Stedman RC, Lim D, Husain A, Courtney PM, Nelson CL (2016) Single-component revisions are associated with dislocation after revision total hip arthroplasty at intermediate-term follow-up. Hip Int 26(3):233–236CrossRefPubMed
25.
Zurück zum Zitat Berend KR, Lombardi AV Jr, Mallory TH, Adams JB, Russell JH, Groseth KL (2005) The long-term outcome of 755 consecutive constrained acetabular components in total hip arthroplasty examining the successes and failures. J Arthroplasty (Suppl 3) 20(7):93–102CrossRef Berend KR, Lombardi AV Jr, Mallory TH, Adams JB, Russell JH, Groseth KL (2005) The long-term outcome of 755 consecutive constrained acetabular components in total hip arthroplasty examining the successes and failures. J Arthroplasty (Suppl 3) 20(7):93–102CrossRef
26.
Zurück zum Zitat Della Valle CJ, Chang D, Sporer S, Berger RA, Rosenberg AG, Paprosky WG (2005) High failure rate of a constrained acetabular liner in revision total hip arthroplasty. J Arthroplasty (Suppl 3) 20(7):103–107CrossRef Della Valle CJ, Chang D, Sporer S, Berger RA, Rosenberg AG, Paprosky WG (2005) High failure rate of a constrained acetabular liner in revision total hip arthroplasty. J Arthroplasty (Suppl 3) 20(7):103–107CrossRef
27.
Zurück zum Zitat Yun AG, Padgett D, Pellicci P, Dorr LD (2005) Constrained acetabular liners: mechanisms of failure. J Arthroplast 20(4):536–541CrossRef Yun AG, Padgett D, Pellicci P, Dorr LD (2005) Constrained acetabular liners: mechanisms of failure. J Arthroplast 20(4):536–541CrossRef
28.
Zurück zum Zitat Williams JT Jr, Ragland PS, Clarke S (2007) Constrained components for the unstable hip following total hip arthroplasty: a literature review. Int Orthop 31(3):273–277CrossRefPubMed Williams JT Jr, Ragland PS, Clarke S (2007) Constrained components for the unstable hip following total hip arthroplasty: a literature review. Int Orthop 31(3):273–277CrossRefPubMed
29.
Zurück zum Zitat Boyer B, Philippot R, Geringer J, Farizon F (2012) Primary total hip arthroplasty with dual mobility socket to prevent dislocation: a 22-year follow-up of 240 hips. Int Orthop 36(3):511–518CrossRefPubMed Boyer B, Philippot R, Geringer J, Farizon F (2012) Primary total hip arthroplasty with dual mobility socket to prevent dislocation: a 22-year follow-up of 240 hips. Int Orthop 36(3):511–518CrossRefPubMed
30.
Zurück zum Zitat Hailer NP, Weiss RJ, Stark A, Kärrholm J (2012) The risk of revision due to dislocation after total hip arthroplasty depends on surgical approach, femoral head size, sex, and primary diagnosis. An analysis of 78,098 operations in the Swedish Hip Arthroplasty register. Acta Orthop 83(5):442–448CrossRefPubMedPubMedCentral Hailer NP, Weiss RJ, Stark A, Kärrholm J (2012) The risk of revision due to dislocation after total hip arthroplasty depends on surgical approach, femoral head size, sex, and primary diagnosis. An analysis of 78,098 operations in the Swedish Hip Arthroplasty register. Acta Orthop 83(5):442–448CrossRefPubMedPubMedCentral
31.
Zurück zum Zitat Berry DJ (2017) Joint registries: what can we learn in 2016. Bone Joint J 99-B(1 supple a):3–7CrossRefPubMed Berry DJ (2017) Joint registries: what can we learn in 2016. Bone Joint J 99-B(1 supple a):3–7CrossRefPubMed
Metadaten
Titel
Comparison of dual mobility cup and other surgical construts used for three hundred and sixty two first time hip revisions due to recurrent dislocations: five year results from Lithuanian arthroplasty register
verfasst von
Justinas Stucinskas
Tomas Kalvaitis
Alfredas Smailys
Otto Robertsson
Sarunas Tarasevicius
Publikationsdatum
02.12.2017
Verlag
Springer Berlin Heidelberg
Erschienen in
International Orthopaedics / Ausgabe 5/2018
Print ISSN: 0341-2695
Elektronische ISSN: 1432-5195
DOI
https://doi.org/10.1007/s00264-017-3702-0

Weitere Artikel der Ausgabe 5/2018

International Orthopaedics 5/2018 Zur Ausgabe

Arthropedia

Grundlagenwissen der Arthroskopie und Gelenkchirurgie. Erweitert durch Fallbeispiele, Videos und Abbildungen. 
» Jetzt entdecken

Update Orthopädie und Unfallchirurgie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.