Skip to main content
Erschienen in: International Orthopaedics 5/2020

01.05.2020 | Review

O-arm navigation versus C-arm guidance for pedicle screw placement in spine surgery: a systematic review and meta-analysis

verfasst von: Weili Feng, Weihao Wang, Shubiao Chen, Kezhou Wu, Hu Wang

Erschienen in: International Orthopaedics | Ausgabe 5/2020

Einloggen, um Zugang zu erhalten

Abstract

Background

O-arm and C-arm are commonly used in spine surgery to guide pedicle screw placement. However, concerning the accuracy and efficiency of them, no systematical review and meta-analyses are available to help surgeons make comparisons.

Purposes

This study aims to investigate the accuracy and efficiency of O-arm-navigated versus C-arm-guided pedicle screw placement in thoracic and lumbar spine surgery. It would help surgeons choose the optimal technique for pedicle screw placement.

Patients and methods

A systematic review and meta-analyses were performed after searching the PubMed, Embase, and Cochrane databases to identify all studies that assessed the accuracy and efficiency of navigation coupled with O-arm and conventional C-arm fluoroscopy.

Results

Eight studies were finally recruited in this systematic review, all of which reported pedicle screw placement outcomes related to accuracy or efficiency in both C-arm and O-arm groups. Five studies showed higher screw insertion accuracy in the O-arm group, while one study showed no significant difference. And the pooled results also indicated that the incidence of screw misplacement in the C-arm groups is higher. Moreover, the pooled results from five studies indicated no significant difference in insertion time between C-arm and O-arm.

Conclusions

Navigation coupled with O-arm imaging displayed a lower efficiency outcome in pedicle screw placement compared to conventional C-arm fluoroscopy. However, in terms of accuracy, O-arm navigation had significant advantages in accuracy over conventional C-arm fluoroscopy.
Literatur
1.
Zurück zum Zitat Annoni E, Joedicke H, Barnett GS (2013) The 3D O-ARM surgical imaging system with navigation effectively and economically addresses the challenges of spinal stabilization procedures. Value Health 16:A556CrossRef Annoni E, Joedicke H, Barnett GS (2013) The 3D O-ARM surgical imaging system with navigation effectively and economically addresses the challenges of spinal stabilization procedures. Value Health 16:A556CrossRef
2.
Zurück zum Zitat Arand M, Schempf M, Kinzl L, Fleiter T, Pless D, Gebhard F (2001) Precision in standardized Iso-C-arm based navigated boring of the proximal femur. Unfallchirurg 104:1150–1156CrossRef Arand M, Schempf M, Kinzl L, Fleiter T, Pless D, Gebhard F (2001) Precision in standardized Iso-C-arm based navigated boring of the proximal femur. Unfallchirurg 104:1150–1156CrossRef
3.
Zurück zum Zitat Arand M, Hartwig E, Kinzl L, Gebhard F (2002) Spinal navigation in tumor surgery of the thoracic spine: first clinical results. Clin Orthop Relat Res 211–8 Arand M, Hartwig E, Kinzl L, Gebhard F (2002) Spinal navigation in tumor surgery of the thoracic spine: first clinical results. Clin Orthop Relat Res 211–8
4.
Zurück zum Zitat Boriani S, Bandiera S, Donthineni R, Amendola L, Cappuccio M, De Iure F (2010) Morbidity of en bloc resections in the spine. Eur Spine J 19:231–241CrossRef Boriani S, Bandiera S, Donthineni R, Amendola L, Cappuccio M, De Iure F (2010) Morbidity of en bloc resections in the spine. Eur Spine J 19:231–241CrossRef
5.
Zurück zum Zitat Epstein NE (2014) Commentary: utility of the O-arm in spinal surgery. Surg Neurol Int 5:S517–S519CrossRef Epstein NE (2014) Commentary: utility of the O-arm in spinal surgery. Surg Neurol Int 5:S517–S519CrossRef
6.
Zurück zum Zitat Gebhard F, Weidner A, Liener UC, Stockle U, Arand M (2004) Navigation at the spine. Injury 35(Suppl 1):S-A35–S-A45CrossRef Gebhard F, Weidner A, Liener UC, Stockle U, Arand M (2004) Navigation at the spine. Injury 35(Suppl 1):S-A35–S-A45CrossRef
7.
Zurück zum Zitat Gertzbein SD, Robbins SE (1990) Accuracy of pedicular screw placement in vivo. Spine (Phila Pa 1976) 15:11–14CrossRef Gertzbein SD, Robbins SE (1990) Accuracy of pedicular screw placement in vivo. Spine (Phila Pa 1976) 15:11–14CrossRef
8.
Zurück zum Zitat Grob D, Magerl F, McGowan DP (1990) Spinal pedicle fixation: reliability and validity of roentgenogram-based assessment and surgical factors on successful screw placement. Spine (Phila Pa 1976) 15:251CrossRef Grob D, Magerl F, McGowan DP (1990) Spinal pedicle fixation: reliability and validity of roentgenogram-based assessment and surgical factors on successful screw placement. Spine (Phila Pa 1976) 15:251CrossRef
9.
Zurück zum Zitat Kim YJ, Lenke LG, Bridwell KH, Cho YS, Riew KD (2004) Free hand pedicle screw placement in the thoracic spine: is it safe? Spine (Phila Pa 1976) 29:333–342 discussion 42CrossRef Kim YJ, Lenke LG, Bridwell KH, Cho YS, Riew KD (2004) Free hand pedicle screw placement in the thoracic spine: is it safe? Spine (Phila Pa 1976) 29:333–342 discussion 42CrossRef
10.
Zurück zum Zitat Knafo S, Mireau E, Bennis S, Baussart B, Aldea S, Gaillard S (2018) Operative and perioperative durations in O-arm vs C-arm fluoroscopy for lumbar instrumentation. Roy-Camille technique versus open-lamina technique. Oper Neurosurg (Hagerstown) 14(3):273–278CrossRef Knafo S, Mireau E, Bennis S, Baussart B, Aldea S, Gaillard S (2018) Operative and perioperative durations in O-arm vs C-arm fluoroscopy for lumbar instrumentation. Roy-Camille technique versus open-lamina technique. Oper Neurosurg (Hagerstown) 14(3):273–278CrossRef
11.
Zurück zum Zitat Lavallee S, Sautot P, Troccaz J, Cinquin P, Merloz P (1995) Computer-assisted spine surgery: a technique for accurate transpedicular screw fixation using CT data and a 3-D optical localizer. J Image Guid Surg 1:65–73CrossRef Lavallee S, Sautot P, Troccaz J, Cinquin P, Merloz P (1995) Computer-assisted spine surgery: a technique for accurate transpedicular screw fixation using CT data and a 3-D optical localizer. J Image Guid Surg 1:65–73CrossRef
12.
Zurück zum Zitat Liu H, Wang YM, Pi B, Qian ZL, Zhu XY, Yang HL (2017) Comparison of intraoperative O-arm- and conventional fluoroscopy (C-arm)-assisted insertion of pedicle screws in the treatment of fracture of thoracic vertebrae. J Orthop Surg 25(1):1–6CrossRef Liu H, Wang YM, Pi B, Qian ZL, Zhu XY, Yang HL (2017) Comparison of intraoperative O-arm- and conventional fluoroscopy (C-arm)-assisted insertion of pedicle screws in the treatment of fracture of thoracic vertebrae. J Orthop Surg 25(1):1–6CrossRef
13.
Zurück zum Zitat Merloz P, Tonetti J, Eid A, Faure C, Lavallee S, Troccaz J, (1997) Computer assisted spine surgery. Clin Orthop Relat Res 86–96 Merloz P, Tonetti J, Eid A, Faure C, Lavallee S, Troccaz J, (1997) Computer assisted spine surgery. Clin Orthop Relat Res 86–96
14.
Zurück zum Zitat Merloz P, Troccaz J, Vouaillat H, Vasile C, Tonetti J, Eid A (2007) Fluoroscopy-based navigation system in spine surgery. Proc Inst Mech Eng H 221:813–820CrossRef Merloz P, Troccaz J, Vouaillat H, Vasile C, Tonetti J, Eid A (2007) Fluoroscopy-based navigation system in spine surgery. Proc Inst Mech Eng H 221:813–820CrossRef
15.
Zurück zum Zitat Mirza SK, Wiggins GC, Kuntz C, York JE, Bellabarba C, Knonodi MA (2003) Accuracy of thoracic vertebral body screw placement using standard fluoroscopy, fluoroscopic image guidance, and computed tomographic image guidance: a cadaver study. Spine (Phila Pa 1976) 28:402–413 Mirza SK, Wiggins GC, Kuntz C, York JE, Bellabarba C, Knonodi MA (2003) Accuracy of thoracic vertebral body screw placement using standard fluoroscopy, fluoroscopic image guidance, and computed tomographic image guidance: a cadaver study. Spine (Phila Pa 1976) 28:402–413
16.
Zurück zum Zitat Moher D, Liberati A, Tetzlaff J, Altman DG (2009) Preferred reporting items for systematic reviews and meta-analyses: the PRISMA statement. PLoS Med 6:e1000097CrossRef Moher D, Liberati A, Tetzlaff J, Altman DG (2009) Preferred reporting items for systematic reviews and meta-analyses: the PRISMA statement. PLoS Med 6:e1000097CrossRef
17.
Zurück zum Zitat Nakagawa H, Kamimura M, Uchiyama S, Takahara K, Itsubo T, Miyasaka T (2003) The accuracy and safety of image-guidance system using intraoperative fluoroscopic images: an in vitro feasibility study. J Clin Neurosci 10:226–230CrossRef Nakagawa H, Kamimura M, Uchiyama S, Takahara K, Itsubo T, Miyasaka T (2003) The accuracy and safety of image-guidance system using intraoperative fluoroscopic images: an in vitro feasibility study. J Clin Neurosci 10:226–230CrossRef
18.
Zurück zum Zitat Rampersaud YR, Foley KT, Shen AC, Williams S, Solomito M (2000) Radiation exposure to the spine surgeon during fluoroscopically assisted pedicle screw insertion. Spine (Phila Pa 1976) 25:2637–2645CrossRef Rampersaud YR, Foley KT, Shen AC, Williams S, Solomito M (2000) Radiation exposure to the spine surgeon during fluoroscopically assisted pedicle screw insertion. Spine (Phila Pa 1976) 25:2637–2645CrossRef
19.
Zurück zum Zitat Schils F (2011) O-arm guided balloon kyphoplasty: preliminary experience of 16 consecutive patients. Acta Neurochir Suppl 109:175–178CrossRef Schils F (2011) O-arm guided balloon kyphoplasty: preliminary experience of 16 consecutive patients. Acta Neurochir Suppl 109:175–178CrossRef
20.
Zurück zum Zitat Schlenzka D, Laine T, Lund T (2000) Computer-assisted spine surgery. Eur Spine J 9(Suppl 1):S57–S64CrossRef Schlenzka D, Laine T, Lund T (2000) Computer-assisted spine surgery. Eur Spine J 9(Suppl 1):S57–S64CrossRef
21.
Zurück zum Zitat Sclafani JA, Regev GJ, Webb J, Garfin SR, Kim CW (2011) Use of a quantitative pedicle screw accuracy system to assess new technology: initial studies on O-arm navigation and its effect on the learning curve of percutaneous pedicle screw insertion. SAS J 5:57–62CrossRef Sclafani JA, Regev GJ, Webb J, Garfin SR, Kim CW (2011) Use of a quantitative pedicle screw accuracy system to assess new technology: initial studies on O-arm navigation and its effect on the learning curve of percutaneous pedicle screw insertion. SAS J 5:57–62CrossRef
22.
Zurück zum Zitat Shin MH, Ryu KS, Park CK (2012) Accuracy and safety in pedicle screw placement in the thoracic and lumbar spines: comparison study between conventional C-arm fluoroscopy and navigation coupled with O-arm® guided methods. J Korean Neurosurg Soc 52:204–209CrossRef Shin MH, Ryu KS, Park CK (2012) Accuracy and safety in pedicle screw placement in the thoracic and lumbar spines: comparison study between conventional C-arm fluoroscopy and navigation coupled with O-arm® guided methods. J Korean Neurosurg Soc 52:204–209CrossRef
23.
Zurück zum Zitat Shin MH, Hur JW, Ryu KS, Park CK (2015) Prospective comparison study between the fluoroscopy-guided and navigation coupled with O-arm - guided pedicle screw placement in the thoracic and lumbosacral spines. J Spinal Disord Tech 28:E347–EE51CrossRef Shin MH, Hur JW, Ryu KS, Park CK (2015) Prospective comparison study between the fluoroscopy-guided and navigation coupled with O-arm - guided pedicle screw placement in the thoracic and lumbosacral spines. J Spinal Disord Tech 28:E347–EE51CrossRef
24.
Zurück zum Zitat Tabaraee E, Gibson AG, Karahalios DG, Potts EA, Mobasser JP, Burch S (2013) Intraoperative cone beam-computed tomography with navigation (O-ARM) versus conventional fluoroscopy (C-ARM): a cadaveric study comparing accuracy, efficiency, and safety for spinal instrumentation. Spine (Phila Pa 1976) 38:1953–1958CrossRef Tabaraee E, Gibson AG, Karahalios DG, Potts EA, Mobasser JP, Burch S (2013) Intraoperative cone beam-computed tomography with navigation (O-ARM) versus conventional fluoroscopy (C-ARM): a cadaveric study comparing accuracy, efficiency, and safety for spinal instrumentation. Spine (Phila Pa 1976) 38:1953–1958CrossRef
25.
Zurück zum Zitat Tajsic T, Patel K, Farmer R, Mannion RJ, Trivedi RA (2018) Spinal navigation for minimally invasive thoracic and lumbosacral spine fixation: implications for radiation exposure, operative time, and accuracy of pedicle screw placement. Eur Spine J 27(8):1918–1924CrossRef Tajsic T, Patel K, Farmer R, Mannion RJ, Trivedi RA (2018) Spinal navigation for minimally invasive thoracic and lumbosacral spine fixation: implications for radiation exposure, operative time, and accuracy of pedicle screw placement. Eur Spine J 27(8):1918–1924CrossRef
26.
Zurück zum Zitat Talotta J (2012) Key to the future: O-arm. J Med Imaging Radiat Sci 43:S63 Talotta J (2012) Key to the future: O-arm. J Med Imaging Radiat Sci 43:S63
27.
Zurück zum Zitat Tian NF, Xu HZ (2009) Image-guided pedicle screw insertion accuracy: a meta-analysis. Int Orthop 33:895–903CrossRef Tian NF, Xu HZ (2009) Image-guided pedicle screw insertion accuracy: a meta-analysis. Int Orthop 33:895–903CrossRef
28.
Zurück zum Zitat Tjardes T, Shafizadeh S, Rixen D, Paffrath T, Bouillon B, Steinhausen ES (2010) Image-guided spine surgery: state of the art and future directions. Eur Spine J 19:25–45CrossRef Tjardes T, Shafizadeh S, Rixen D, Paffrath T, Bouillon B, Steinhausen ES (2010) Image-guided spine surgery: state of the art and future directions. Eur Spine J 19:25–45CrossRef
29.
Zurück zum Zitat Van Brussel K, Vander Sloten J, Van Audekercke R, Fabry G (1996) Internal fixation of the spine in traumatic and scoliotic cases. The potential of pedicle screws. Technol Health Care 4:365–384CrossRef Van Brussel K, Vander Sloten J, Van Audekercke R, Fabry G (1996) Internal fixation of the spine in traumatic and scoliotic cases. The potential of pedicle screws. Technol Health Care 4:365–384CrossRef
30.
Zurück zum Zitat Van de Kelft E, Costa F, Van der Planken D, Schils F (2012) A prospective multicenter registry on the accuracy of pedicle screw placement in the thoracic, lumbar, and sacral levels with the use of the O-arm imaging system and StealthStation navigation. Spine (Phila Pa 1976) 37:E1580–E1587CrossRef Van de Kelft E, Costa F, Van der Planken D, Schils F (2012) A prospective multicenter registry on the accuracy of pedicle screw placement in the thoracic, lumbar, and sacral levels with the use of the O-arm imaging system and StealthStation navigation. Spine (Phila Pa 1976) 37:E1580–E1587CrossRef
31.
Zurück zum Zitat Van de Kraats EB, Van Walsum T, Kendrick L, Noordhoek NJ, Niessen WJ (2006) Accuracy evaluation of direct navigation with an isocentric 3D rotational X-ray system. Med Image Anal 10:113–124CrossRef Van de Kraats EB, Van Walsum T, Kendrick L, Noordhoek NJ, Niessen WJ (2006) Accuracy evaluation of direct navigation with an isocentric 3D rotational X-ray system. Med Image Anal 10:113–124CrossRef
32.
Zurück zum Zitat Verma SK, Singh PK, Agrawal D, Sinha S, Gupta D, Satyarthee GD, Sharma BS (2016) O-arm with navigation versus C-arm: a review of screw placement over 3 years at a major trauma center. Br J Neurosurg 30(6):658–661CrossRef Verma SK, Singh PK, Agrawal D, Sinha S, Gupta D, Satyarthee GD, Sharma BS (2016) O-arm with navigation versus C-arm: a review of screw placement over 3 years at a major trauma center. Br J Neurosurg 30(6):658–661CrossRef
33.
Zurück zum Zitat Weinstein JN, Spratt KF, Spengler D, Brick C, Reid S (1988) Spinal pedicle fixation: reliability and validity of roentgenogram-based assessment and surgical factors on successful screw placement. Spine (Phila Pa 1976) 13:1012–1018CrossRef Weinstein JN, Spratt KF, Spengler D, Brick C, Reid S (1988) Spinal pedicle fixation: reliability and validity of roentgenogram-based assessment and surgical factors on successful screw placement. Spine (Phila Pa 1976) 13:1012–1018CrossRef
34.
Zurück zum Zitat Wood M, Mannion R (2011) A comparison of CT-based navigation techniques for minimally invasive lumbar pedicle screw placement. J Spinal Disord Tech 24:E1–E5CrossRef Wood M, Mannion R (2011) A comparison of CT-based navigation techniques for minimally invasive lumbar pedicle screw placement. J Spinal Disord Tech 24:E1–E5CrossRef
35.
Zurück zum Zitat Xu R, Ebraheim NA, Ou Y, Yeasting RA (1998) Anatomic considerations of pedicle screw placement in the thoracic spine. Roy-Camille technique versus open-lamina technique. Spine (Phila Pa 1976) 23:1065–1068CrossRef Xu R, Ebraheim NA, Ou Y, Yeasting RA (1998) Anatomic considerations of pedicle screw placement in the thoracic spine. Roy-Camille technique versus open-lamina technique. Spine (Phila Pa 1976) 23:1065–1068CrossRef
Metadaten
Titel
O-arm navigation versus C-arm guidance for pedicle screw placement in spine surgery: a systematic review and meta-analysis
verfasst von
Weili Feng
Weihao Wang
Shubiao Chen
Kezhou Wu
Hu Wang
Publikationsdatum
01.05.2020
Verlag
Springer Berlin Heidelberg
Erschienen in
International Orthopaedics / Ausgabe 5/2020
Print ISSN: 0341-2695
Elektronische ISSN: 1432-5195
DOI
https://doi.org/10.1007/s00264-019-04470-3

Weitere Artikel der Ausgabe 5/2020

International Orthopaedics 5/2020 Zur Ausgabe

Arthropedia

Grundlagenwissen der Arthroskopie und Gelenkchirurgie. Erweitert durch Fallbeispiele, Videos und Abbildungen. 
» Jetzt entdecken

Update Orthopädie und Unfallchirurgie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.