Abstract

Augmentation mammaplasty is one of the most common aesthetic procedures performed. Early complications of the procedure are hematoma and infection, and late complications include capsular contracture and device failure or its displacement. Failure of saline implants is readily identifiable, whereas rupture of silicon gel implants can occur without symptoms due to lack of volume loss. Autoinflation of the breast caused by intracapsular and intraprosthetic collection of sterile pus has been reported. A series of five consecutive breast autoinflations with sterile pus is presented. All the patients presented with acute swelling of the breast 2–10 years after prostheses implantation. Intracapsular sterile pus with macroscopic shell tear was seen in four cases. In the remaining case, an intracapsular and intraprosthetic collection of sterile pus with a tear in an otherwise intact implant was seen under the microscope. All five cases showed no microbial growth on culture or sensitivity, and all were treated using a single-stage procedure. The follow-up periods ranged from 8 weeks to 1 year without recurrence of symptoms.
Literatur
1.
Zurück zum Zitat Ann CY, Ko CY, Wager EA, Wong RS, Shah WW (1995) Clinical significance of intracapsular fluid in patients’ breast implants. Ann Plast Surg 35:455–457CrossRef Ann CY, Ko CY, Wager EA, Wong RS, Shah WW (1995) Clinical significance of intracapsular fluid in patients’ breast implants. Ann Plast Surg 35:455–457CrossRef
2.
Zurück zum Zitat Ann CY, Ko CY, Wager EA, Wong RS, Shah WW (1996) Microbial evaluation: 139 implants removed from symptomatic patients. Plast Reconstr Surg 98:1225–1229CrossRef Ann CY, Ko CY, Wager EA, Wong RS, Shah WW (1996) Microbial evaluation: 139 implants removed from symptomatic patients. Plast Reconstr Surg 98:1225–1229CrossRef
3.
Zurück zum Zitat Netscher DT, Welzer G, Wigoda P, Walker LE, Thomby J, Bowen D (1995) Clinical relevance of positive breast periprosthetic cultures without overt infection. Plast Reconstr Surg 96:1125–1229PubMed Netscher DT, Welzer G, Wigoda P, Walker LE, Thomby J, Bowen D (1995) Clinical relevance of positive breast periprosthetic cultures without overt infection. Plast Reconstr Surg 96:1125–1229PubMed
4.
Zurück zum Zitat Nahebedian MY, Tsangaris T, Momen B, Manson PN (2003) Infectious complications following breast reconstruction with expanders and implants. Plast Reconstr Surg 112:467–476CrossRef Nahebedian MY, Tsangaris T, Momen B, Manson PN (2003) Infectious complications following breast reconstruction with expanders and implants. Plast Reconstr Surg 112:467–476CrossRef
5.
Zurück zum Zitat Cholnoky T (1970) Augmentation mammaplasty: survey of complications in 10,941 patients by 265 surgeons. Plast Reconstr Surg 45:573PubMedCrossRef Cholnoky T (1970) Augmentation mammaplasty: survey of complications in 10,941 patients by 265 surgeons. Plast Reconstr Surg 45:573PubMedCrossRef
6.
Zurück zum Zitat Courtiss EH, Goldwyn RM, Anastasi GW (1979) The fate of breast implants with infections around them. Plast Reconstr Surg 63:812PubMedCrossRef Courtiss EH, Goldwyn RM, Anastasi GW (1979) The fate of breast implants with infections around them. Plast Reconstr Surg 63:812PubMedCrossRef
7.
Zurück zum Zitat Cronin TD, Greenberg RL (1970) Our experience with the silastic gel breast prosthesis. Plast Reconstr Surg 46:1–7PubMedCrossRef Cronin TD, Greenberg RL (1970) Our experience with the silastic gel breast prosthesis. Plast Reconstr Surg 46:1–7PubMedCrossRef
8.
Zurück zum Zitat Spear SL, Howard MA, Boehmler JH, Ducic I, Low M, Abbruzzesse MR (2004) The infected or exposed implant: management and treatment strategies. Plast Reconstr Surg 113:1634–1644 Spear SL, Howard MA, Boehmler JH, Ducic I, Low M, Abbruzzesse MR (2004) The infected or exposed implant: management and treatment strategies. Plast Reconstr Surg 113:1634–1644
9.
Zurück zum Zitat Tatla T, Ho-Asjoe M, Shibu M (2005) Sudden onset breast swelling: an unusual presentation of ruptured prosthesis 10 years postimplantation. Eur J Plast Surg 27:391–393CrossRef Tatla T, Ho-Asjoe M, Shibu M (2005) Sudden onset breast swelling: an unusual presentation of ruptured prosthesis 10 years postimplantation. Eur J Plast Surg 27:391–393CrossRef
10.
Zurück zum Zitat Robinson OG Jr, Benos DJ, Mazzochi C (2005) Spontaneous autoinfaltion of saline mammary implants: further studies. Aesth Surg J 25:582–586CrossRef Robinson OG Jr, Benos DJ, Mazzochi C (2005) Spontaneous autoinfaltion of saline mammary implants: further studies. Aesth Surg J 25:582–586CrossRef
11.
Zurück zum Zitat Khan UD (2008) Unilateral breast autoinflation and intraprosthetic collection of sterile pus. An unusual operative finding of silicon gel bleed with silicone lymphadenitis. Aesth Plast Surg 32:684–687CrossRef Khan UD (2008) Unilateral breast autoinflation and intraprosthetic collection of sterile pus. An unusual operative finding of silicon gel bleed with silicone lymphadenitis. Aesth Plast Surg 32:684–687CrossRef
12.
Zurück zum Zitat Khan UD (2007) Muscle-splitting breast augmentation: a new pocket in a different plane. Aesth Plast Surg 31:553–558CrossRef Khan UD (2007) Muscle-splitting breast augmentation: a new pocket in a different plane. Aesth Plast Surg 31:553–558CrossRef
13.
Zurück zum Zitat Khan UD (2008) Use of rectus sternalis in augmentation mammaplasty: case report and literature search. Aesth Plast Surg 32:21–24CrossRef Khan UD (2008) Use of rectus sternalis in augmentation mammaplasty: case report and literature search. Aesth Plast Surg 32:21–24CrossRef
14.
Zurück zum Zitat Spears SL, Little JW III (1988) Breast capsulorraphy. Plast Reconstr Surg 81:274–279CrossRef Spears SL, Little JW III (1988) Breast capsulorraphy. Plast Reconstr Surg 81:274–279CrossRef
15.
Zurück zum Zitat Macadam SA, Mehling BM, Fanning A, Dufton JA, Kowalewska-Grochowska KT, Lennox P, Anzarut A, Rodrigues M (2007) Nontuberculous mycobacterial breast implant infections. Plast Reconstr Surg 119:337–344PubMedCrossRef Macadam SA, Mehling BM, Fanning A, Dufton JA, Kowalewska-Grochowska KT, Lennox P, Anzarut A, Rodrigues M (2007) Nontuberculous mycobacterial breast implant infections. Plast Reconstr Surg 119:337–344PubMedCrossRef
16.
Zurück zum Zitat Heistein JB, Mangino JE, Ruberg RL, Bergese JJ (2000) A prosthetic breast implant infected with mycobacterium fortuitm. Ann Plast Surg 44:330–333PubMedCrossRef Heistein JB, Mangino JE, Ruberg RL, Bergese JJ (2000) A prosthetic breast implant infected with mycobacterium fortuitm. Ann Plast Surg 44:330–333PubMedCrossRef
17.
Zurück zum Zitat Holmich LB, Jon F, Kjoller K, Breiting VB, Jorgensen A, Krag C, McLaughlin JK (2005) The diagnosis of silicon breast implant rupture: clinical findings compare with findings as magnetic resonance imaging. Ann Plast Surg 54:583–589PubMedCrossRef Holmich LB, Jon F, Kjoller K, Breiting VB, Jorgensen A, Krag C, McLaughlin JK (2005) The diagnosis of silicon breast implant rupture: clinical findings compare with findings as magnetic resonance imaging. Ann Plast Surg 54:583–589PubMedCrossRef
18.
Zurück zum Zitat Holmich LR, Friis S, Fryzek JP, Vejborg IM, Conrad C, Sletting S, Kjoller K, McLaughlin JK, Olsen JH (2003) Incidence of silicon breast implant rupture. Arch Surg 138:801–806PubMedCrossRef Holmich LR, Friis S, Fryzek JP, Vejborg IM, Conrad C, Sletting S, Kjoller K, McLaughlin JK, Olsen JH (2003) Incidence of silicon breast implant rupture. Arch Surg 138:801–806PubMedCrossRef
19.
Zurück zum Zitat Marotta J, Goldberg EP, Habel MB, Amery DP, Martin PJ, Urbaniak DJ, Widenhouse CW (2002) Silicon gel breast implant failure: evaluation of properties of shells and gels for explanted prosthesis and meta-analysis of literature rupture data. Ann Plast Surg 49:227–247PubMedCrossRef Marotta J, Goldberg EP, Habel MB, Amery DP, Martin PJ, Urbaniak DJ, Widenhouse CW (2002) Silicon gel breast implant failure: evaluation of properties of shells and gels for explanted prosthesis and meta-analysis of literature rupture data. Ann Plast Surg 49:227–247PubMedCrossRef
20.
Zurück zum Zitat Brandon HJ, Young VL, Jerina KL, Wolf CJ (2001) Scanning electron microscopy characterization of surgical instrument damage to breast implants. Plast Reconstr Surg 108:52–61PubMedCrossRef Brandon HJ, Young VL, Jerina KL, Wolf CJ (2001) Scanning electron microscopy characterization of surgical instrument damage to breast implants. Plast Reconstr Surg 108:52–61PubMedCrossRef
Metadaten
Titel
Breast Autoinflation with Sterile Pus as a Marker of Implant Rupture: Single-Stage Treatment and Outcome for Five Consecutive Cases
verfasst von
Umar Daraz Khan
Publikationsdatum
01.01.2009
Verlag
Springer-Verlag
Erschienen in
Aesthetic Plastic Surgery / Ausgabe 1/2009
Print ISSN: 0364-216X
Elektronische ISSN: 1432-5241
DOI
https://doi.org/10.1007/s00266-008-9225-8

Weitere Artikel der Ausgabe 1/2009

Aesthetic Plastic Surgery 1/2009 Zur Ausgabe

Update Chirurgie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.

S3-Leitlinie „Diagnostik und Therapie des Karpaltunnelsyndroms“

CME: 2 Punkte

Prof. Dr. med. Gregor Antoniadis Das Karpaltunnelsyndrom ist die häufigste Kompressionsneuropathie peripherer Nerven. Obwohl die Anamnese mit dem nächtlichen Einschlafen der Hand (Brachialgia parästhetica nocturna) sehr typisch ist, ist eine klinisch-neurologische Untersuchung und Elektroneurografie in manchen Fällen auch eine Neurosonografie erforderlich. Im Anfangsstadium sind konservative Maßnahmen (Handgelenksschiene, Ergotherapie) empfehlenswert. Bei nicht Ansprechen der konservativen Therapie oder Auftreten von neurologischen Ausfällen ist eine Dekompression des N. medianus am Karpaltunnel indiziert.

Prof. Dr. med. Gregor Antoniadis
Berufsverband der Deutschen Chirurgie e.V.

S2e-Leitlinie „Distale Radiusfraktur“

CME: 2 Punkte

Dr. med. Benjamin Meyknecht, PD Dr. med. Oliver Pieske Das Webinar S2e-Leitlinie „Distale Radiusfraktur“ beschäftigt sich mit Fragen und Antworten zu Diagnostik und Klassifikation sowie Möglichkeiten des Ausschlusses von Zusatzverletzungen. Die Referenten erläutern, welche Frakturen konservativ behandelt werden können und wie. Das Webinar beantwortet die Frage nach aktuellen operativen Therapiekonzepten: Welcher Zugang, welches Osteosynthesematerial? Auf was muss bei der Nachbehandlung der distalen Radiusfraktur geachtet werden?

PD Dr. med. Oliver Pieske
Dr. med. Benjamin Meyknecht
Berufsverband der Deutschen Chirurgie e.V.

S1-Leitlinie „Empfehlungen zur Therapie der akuten Appendizitis bei Erwachsenen“

CME: 2 Punkte

Dr. med. Mihailo Andric
Inhalte des Webinars zur S1-Leitlinie „Empfehlungen zur Therapie der akuten Appendizitis bei Erwachsenen“ sind die Darstellung des Projektes und des Erstellungswegs zur S1-Leitlinie, die Erläuterung der klinischen Relevanz der Klassifikation EAES 2015, die wissenschaftliche Begründung der wichtigsten Empfehlungen und die Darstellung stadiengerechter Therapieoptionen.

Dr. med. Mihailo Andric
Berufsverband der Deutschen Chirurgie e.V.