Improving the Longevity and Results of Mastopexy and Breast Reduction Procedures: Reconstructing an Internal Breast Support System with Biocompatible Mesh to Replace the Supporting Function of the Ligamentous Suspension

verfasst von: Petrus V. van Deventer, Frank R. Graewe, Elisabeth Würinger

Erschienen in: Aesthetic Plastic Surgery | Ausgabe 3/2012

Abstract

Background

The reasons for recurrent ptosis in mastopexy and breast reduction procedures are twofold. First, available surgical techniques do not reconstruct the normal breast anatomy responsible for maintaining breast shape. Second, in many instances the techniques rely on atrophied tissue to provide long-term support. The discovery in 1997 of the ligamentous suspension (the supporting system of the breast) gave rise to the concept that reconstruction of this anatomical structure was needed to ensure a sustained postoperative result. Applying the latest knowledge regarding the structural and vascular anatomy of the breast in the surgical technique and utilizing material other than atrophied breast tissue enabled us to prevent the recurrence of breast ptosis.

Methods

A surgical technique was developed to replace the supportive function of a failed ligamentous suspension in 112 patients with ptotic breasts. This was done by reconstructing an internal breast-supporting system (IBSS) with biocompatible mesh.

Results

Satisfactory breast shape, nipple projection, and upper breast fullness was obtained with this technique in mastopexy patients with moderate-sized ptotic breasts. In patients with larger breasts good results were obtained with a simultaneous breast reduction. The longest follow-up is 6 years 3 months.

Conclusions

With this technique recurrent breast ptosis can be prevented in mastopexy and breast reduction procedures. The results are such that it eliminates the need for silicone prostheses to obtain satisfactory upper-breast fullness. The surgical technique is especially indicated in patients with skin of poor quality or patients with high expectations.
Hinweise
Presented at the Annual General Meeting of the Association of Plastic and Reconstructive Surgeons of South Africa combined with the 5th Pan African Congress, Natal, South Africa, 22–26 October 2006; International Society of Aesthetic Plastic Surgery, Cape Town, South Africa, 17–19 March 2007; International Society of Aesthetic Plastic Surgery, Melbourne, Australia, 10–13 February 2008; and British Association of Aesthetic Plastic Surgeons, London, UK, 22–23 September 2010.
Breast ptosis is a result of weakening and lengthening of the supporting structures of the breast. In most instances current mastopexy procedures to correct ptosis rely on atrophied tissue for support. Understandably, this may result in recurrent ptosis and unsatisfactory long-term appearance. Previous attempts to prevent recurrent ptosis, utilizing materials other than atrophied tissue, did not stand the test of time [1, 2], probably because of the disregard of the normal breast anatomy.
In his personal mammaplasty technique, Goés [37] has used mesh as a support since 1988 and reported good results with minimal complications. His periareolar double-skin technique entails insertion of mesh that evokes connective tissue formation that functions as ligaments of Cooper. Recently, De Bruijn and Johannes [8, 9] used a preshaped polyester mesh for breast support. The disadvantage of their technique is the fixed shape of the mesh, available in only four sizes, which limits the cosmetic results otherwise obtainable.
With inferior pedicle techniques, the maintenance of the breast shape relies mainly on the skin envelope and postoperative stretching results in recurrent ptosis. Skin tension to maintain breast shape, transferred onto the suture lines, may result in obvious scars as well.
New concepts of the structural anatomy of the breast have opened the door to combat these complications effectively. The ligamentous suspension of the breast, discovered and described by Würinger [10, 11], acts as a hammock to support the breast and is of much greater importance than the ligaments of Cooper. Reinforcement of the failed ligamentous suspension in the ptotic breast using a nonabsorbable biocompatible material can offer a long-term solution to the ptotic breast.
The aim of this study was to show that replacement of the failed ligamentous suspension with an internal breast-supporting system (IBSS) consisting of biocompatible, nonabsorbable mesh will prevent recurrent ptosis. A second goal was to obtain optimal and long-lasting breast shape, nipple projection, adequate upper-breast fullness, and inconspicuous and well-located short scars.

Pertinent Anatomy

Blood Supply

Success of breast surgery depends on ensuring adequate blood supply. The most reliable source is the internal thoracic–anterior intercostal system by means of perforators 1–4 of the internal thoracic artery and the inferior mammary branches of the fourth to sixth anterior intercostal arteries, as described by van Deventer [12, 13] (Fig. 1).

Supporting System

The main supporting system of the breast is the ligamentous suspension as described by Würinger [10, 11]. This anatomical structure is U-shaped and attached to the thoracic cage. At its lower part it stretches from the fifth rib to the nipple as a horizontal septum and, in continuation, extends medially and laterally upward as vertical ligaments. It is attached medially to the sternum as high as the manubrium and laterally along the lateral border of the pectoralis minor muscle to the chest wall into the axilla; it supports the breast like a hammock (Fig. 1).
The neurovascular supply is guided by the ligamentous suspension, acting like a mesentery, as shown by Würinger [11]. The branches of the anterior intercostal arteries course in the horizontal septum. The medial and lateral vertical ligaments guide the perforating branches of the internal thoracic artery and the branches of the lateral thoracic artery, respectively [11].

Application of the Relevant Anatomy

It is the authors’ opinion that reliance on a postero-inferomedial pedicle with inclusion of the horizontal septum and medial vertical ligament is the optimal pedicle choice in mastopexy and breast reduction procedures (Fig. 2) [13, 14]. Meticulous surgery allows preservation of the perforating branches of the internal thoracic artery in the medial vertical ligament and the inferior mammary branches of the anterior intercostal arteries in the horizontal septum.

Materials and Methods

Approval for this study was obtained from the ethics committee of the Faculty of Health Sciences at the University of Stellenbosch, Western Cape, South Africa (project No. 04/03/053). The foundation to this work was laid in two stages. It consisted of anatomical studies followed by surgical procedures in a clinical trail in the human model.

Preoperative Research

Cadaver Study

The aim of the cadaver study was to develop a surgical technique for insertion and attachment of a mesh to the chest wall to replace the function of the ligamentous suspension. The technique should cause the least damage to the neurovascular supply and minimal scarring.
Four breasts were dissected. In two breasts the standard Wise-skin incision was used, and in the other two, an incision along the superolateral areolar margin and a 5-cm incision in the lateral submammary crease were used. From the incision sites, subcutaneous dissection planes were created to expose the anatomical areas where the ligamentous suspension attaches. The perforator branches of the internal thoracic artery, emerging one-finger-breadth lateral to the sternal border, could be kept intact, attached to the nipple-bearing pedicle. The branches of the lateral thoracic artery had to be transected to expose the superolateral thoracic wall adequately. It was possible to obtain adequate exposure for attachment of the mesh using the periareolar submammary incisions. However, it was easier with the standard Wise skin incision.
This technique ensured a robust blood supply to the pedicle and nipple–areola complex. A U-shaped mesh was utilized that created a cone on overlapping the arms. It was anchored to the chest wall on areas corresponding to the attachment of the ligamentous suspension. By exerting tension on the mesh and altering the amount of overlap, different breast shapes could be created.

Patient Pilot Study

The purpose of the study, including the risks and potential complications, was explained to 15 trial patients. They were all post-child-bearing, healthy patients without a history of bleeding tendencies or infection. Voluntary, informed, written consent was obtained from all the patients. The ages of the patients ranged from 27 to 62 years (mean = 37.8 years).
Biocompatible mesh was implanted in seven patients during a mastopexy procedure and in eight patients with reduction procedures, of which four were unilateral. Patients who underwent unilateral mesh implants had very large breasts with related symptoms and did not care about the cosmetic outcome of the procedure, they only wanted symptomatic relief.
The mesh consisted of equal amounts of nonabsorbable polypropylene and absorbable polyglactin (Johnson & Johnson, c/o European Logistics Centre, St-Stevens-Woluwe, Belgium).

Results

Patient data and results are given in Table 1. In the mastopexy group, two patients were very satisfied with the result and two were satisfied. Two patients were dissatisfied due to poor breast shape with minimal improvement and recurrent ptosis. Both patients had large hypertrophic breasts. One patient was dissatisfied because of bilateral loss of nipple sensation.
Table 1
Patient pilot study
No.
Age
Bra size
Preop measurements (cm)
Postop measurements (cm)
Complications
Patient satisfaction
SN-N
N-SF
SN-N
N-SF
R
L
R
L
R
L
R
L
A. Mastopexy patients with mesh implantations
 1
34
36C
27
27
8
9
23
23
9
9
None
Very satisfied
 2
32
34B
24
23
9
9
22
21
8
8
None
Satisfied
 3
40
36C
27
28
9
8
25
26
10
9
None
Satisfied
 4
39
36DD
30
30
13
12
28
29
12
12
Recurrent ptosis
Not satisfied
 5
32
36C
26
26
8
8
24
24
7
7
Bilateral loss of nipple sensation
Not satisfied
 6
31
38C
24
23
8
7
22
22
8
8
None
Very satisfied
 7
37
38C
28
28
10
10
26
26
10
10
Minimal improvement
Not satisfied
No.
Age
Bra size
Breast mass excised (g)
Preop measurements (cm)
Postop measurements (cm)
Complications
Patient satisfaction
SN-N
N-SF
SN-N
N-SF
R
L
R
L
R
L
R
L
R
L
B. Breast reduction patients with bilateral mesh implants
 1
39
34DD
260
270
28
28
10
10
21
21
9
9
Temporary loss of nipple sensation
Very satisfied
 2
39
38DD
550
500
29
30
10
10
23
22
10
10
Infection
Satisfied
 3
35
36D
250
250
27
27
9
9
21
21
8
8
None
Very satisfied
 4
38
38F
300
300
30
30
10
10
22
22
10
10
Fat necrosis
Very satisfied
No.
Age
Bra size
Breast mass excised (g)
Preop measurements (cm)
Postop measurements (cm)
Breast with mesh
Complications
Patient satisfaction
SN-N
N-SF
SN-N
N-SF
R
L
R
L
R
L
R
L
R
L
C. Breast reduction patients with unilateral mesh implanted
 1
23
42DD
1000
1000
32
33
14
14
22
22
11
11
L
None
Satisfied
 2
46
38C
450
425
28
28
11
11
22
22
9
11
R
None
Satisfied
 3
44
44DD
700
950
33
36
13
13
23
22
11
12
L
Fat necrosis
Satisfied
 4
62
38D
200
160
30
29
9
9
23
25
10
10
R
None
Satisfied
SN-N Supra-sternal notch to nipple distance, N-SF nipple to submammary fold distance, R right, and L left
In the reduction group with bilateral mesh implants, three patients were very satisfied and one was satisfied.
In the unilateral mesh-implanted breast reduction group, all four patients were satisfied. In two of them, 425 g or less of breast tissue was removed resulting in an improved breast shape in the mesh-implanted breast (Figs. 3, 4). In the other two patients, minimal improvement was observed in the mesh-implanted breast (Fig. 5). They had removal of 700 g or more of breast tissue per breast (Fig. 5).

Complications

The complications encountered were comparable to those of conventional mastopexy and breast reduction procedures, as seen in Table 2. One patient developed a Streptococcus milleri infection resulting in a sinus that was successfully treated by exploration and partial excision of the mesh. One patient developed a breast lump that was surgically removed and the histology confirmed fatty necrosis. Two patients developed bilateral loss of nipple sensation, one of which was only temporary.
Table 2
Complications of the pilot study of 15 patients (26 breasts)
Complications
Breasts
%
Loss of nipple sensation
2
7.6
Fat necrosis
2
7.6
Infection
1
3.8

Conclusions

Mesh implantation to function as a ligamentous suspension is successful in patients with moderate-sized ptotic breasts (B or C cup). In larger breasts (D cup or larger), simultaneous breast reduction is needed to obtain satisfactory results. Good results can be obtained if there is a need for excision of 550 g or less. In very large breasts (DD or larger), the results of mesh implantation are not ideal, and if more than 700 g needs to be excised, the procedure is of less benefit to the patient.

Operations Performed

From May 2004 to June 2009 a total of 112 patients were operated on (Table 3), including the 15 patients in initial pilot study. In two postmastectomy patients, the device was implanted in the opposite breast to match the reconstructed breast. In the pilot study group, four patients had breast reductions with unilateral implantation of the mesh. In total, 218 breasts were operated on (152 mastopexies and 66 reductions).
Table 3
Patient data
No. of patients operated
112
Age at operation
 Range
20–69 years
 Mean
42.6 years
Body mass index
 Range
20–39
 Mean
25.3
Indications for surgery
 Breast ptosis
76
 Breast hypertrophy and ptosis
34
 Contralateral symmetrization
2
Surgical procedures
 Total No. of breasts operated
218
 Mastopexy
156
 Breast reduction
62
Mean preoperative measurements (cm)
Right
Left
 Jugular notch to nipple
28.5
28.9
 Nipple to submammary fold
9.7
9.8
Mean postoperative measurements (cm)
Right
Left
 Jugular notch to nipple
21.7
21.8
 Nipple to submammary fold
8.8
8.9
Breast mass resected (g)
Right
Left
 Range
50–1,561
60–1,735
 Mean
285
307
Follow-up time after operation
 Longest follow-up
6 years 3 months
 Mean
2 years 2 months
The average operating time was 3 h 20 min. The age of the patients was between 20 and 69 years (mean = 42.6 years). The body mass index was in the range of 20–39 kg/m2 (mean = 25.3). All patients were healthy with no comorbidities. Exclusion criteria included bleeding disorders, infection of any kind, and breast disease. Smokers were instructed to stop smoking 3 months before surgery.

Surgical Technique

Preoperative Skin Markings

The new nipple position is identified with the patient in the upright position. The inferior areola border is marked on the level of the submammary fold, just lateral to the midclavicular line and the nipple 2 cm higher. A modified Wise-pattern approach is used. By displacing the breast tissue medially and laterally, the vertical arms of the “keyhole” are determined and the marks continued from the future nipple position inferiorly to meet at a point 2 cm above the submammary fold.

Exposure and Developing the Pedicle

In essence, the technique entails separation of the skin from the glandular component, exposing the anchoring points of the ligamentous suspension (Fig. 1). All the operations were performed with the patient under general anesthesia. Dissection planes were infiltrated with 10 ml 0.5% bupivacaine and 1:200,000 adrenalin diluted with 20 ml normal saline for each breast.
After deepithelialization, a medial flap approximately 1-cm thick is developed by incising the skin and subcutaneous tissue down to the anterior chest wall, extending from the submammary region to the level of the second sternochondral junction (Fig. 6a). A similar lateral flap is developed, exposing the lateral free border of the pectoralis major muscle (Fig. 6b). Superiorly, the dissection planes are then joined (Fig. 6c). Care must be taken that the medial vertical ligament remains attached to the anterior thoracic wall as part of the pedicle. The upper flap is beveled to become thicker until the pectoral fascia is reached. This thicker flap adds volume to the upper breast. Blunt dissection is performed superiorly, exposing the subclavicular pectoral fascia.
In the hypertrophied breast, the axillary tail and adequate breast tissue from the central mound are excised. A postero-inferomedial pedicle with an intact horizontal septum and medial vertical ligament is developed [13, 14] (Fig. 2). Meticulous hemostasis is obtained.

Applying the Mesh

The lower part of the U-shaped mesh is attached in the submammary region with a 3/0 nonabsorbable suture to the periosteum of the fifth rib. Tension is exerted on the vertical arms of the mesh to avoid folds, and sutures are applied circumferentially, superiorly, fixing the mesh to the lateral thoracic wall. On reaching the midaxillary line, a nonabsorbable 1/0 suture is used to anchor the mesh to the periosteum of the fourth rib behind the free inferolateral border of the pectoralis major muscle (Fig. 1). Due to the slant of the ribs, this level is well above the level of the normal nipple position.
The same procedure is followed on the medial side, and superomedially an anchoring suture of the same material is passed through the perichondrium of the second sternochondral junction (Fig. 1), creating a supporting hammock. The vertical arms of the mesh are overlapped until a satisfactory breast shape is obtained, and the mesh is attached to the subclavicular pectoral fascia for additional support. A cone of mesh-supported breast tissue, thus created with medial and lateral vertical vectors, is attached to the chest wall (Fig. 6d). The same procedure is repeated on the opposite breast and evaluated for symmetry.

Closure

The skin flaps are draped over the breast cone and sutured with minimal tension using subcutaneous and subcuticular 3/0 absorbable sutures. If excessive skin (dog-ears) needs to be removed, the length of the vertical incision line is increased to limit the horizontal scar to the submammary crease (Fig. 6e, f). The nipple–areola complex is sutured with four subcutaneous sutures to obtain even tension followed by a subcuticular suture. Suction drains are used routinely and removed on the first postoperative day. Intraoperatively, the patients receive an intravenous antibiotic (cefuroxime 1.5 g).

Postoperative Care

Patients preferably were kept in the hospital overnight. They were warned that this procedure is more painful than the conventional techniques due to the fact that the mesh is anchored to the chest wall. The recovery period may be longer as well. In some patients, discomfort lasted 6 weeks postoperatively. For this reason they were instructed to wear firm breast support and to refrain from strenuous physical activities during this period. Patients were followed up after 1 week, 3 months, 6 months, and annually thereafter.

Results

Patient characteristics and surgical data are summarized in Table 3. Satisfactory long-lasting breast shape, nipple projection, and upper-breast fullness were obtained in most patients (Figs. 7, 8, 9, 10, 11). A coincidental decrease in areola diameter was observed, seen in most patients from 1 year postoperatively (Fig. 12). One patient lost 10 kg of body mass postoperatively, resulting in a decrease in breast volume but without recurrent ptosis (Fig. 13).
Patients in the pilot study group with unilateral mesh implants, and in whom less than 550 g was excised, revealed long-term maintenance of breast shape in the mesh-implanted breast (Figs. 3, 4). On the other hand, in those patients in whom 700 g or more was excised, very little difference was observed postoperatively between the mesh-implanted and contralateral breasts. The longest follow-up is 6 years 3 months (mean = 2 years 2 months) (Table 4).
Table 4
Complications in 218 breast procedures with mesh implants
Long-term loss of nipple sensation
8
3.66%
Infection
2
0.91%
Fat necrosis
3
1.37%
Superficial areola epidermolysis
1
0.45%
Hematoma
1
0.45%
Hypertrophic scars
2
0.91%

Discussion

Results in plastic surgery can be improved by application in the surgical technique of principles based on normal anatomy. The described technique is based on recent discoveries in breast anatomy. Reconstructing a structure to replace the supporting function of the ligamentous suspension resulted in aesthetically pleasing and long-term results (Figs. 7, 8, 9, 10, 11, 12).
The observation of a decrease in areola diameter postoperatively (Fig. 12) is an indication that the mass of the breast parenchyma is effectively supported by the mesh. The mesh replaces the ligamentous suspension and releases the skin from the function of maintaining breast shape postoperatively. Due to its inherent elasticity, skin shrinkage results in the decreased areola diameter. Another indication of the effective breast support function of the mesh is noted in the patient who lost 10 kg of body mass: despite reduction in breast volume, she did not develop recurrent ptosis (Fig. 13).
The breast mass is an important factor in the success of the procedure. With inadequate breast volume the results will be suboptimal. On the other hand, if the breast mass to be supported by the mesh is too large, the results may not be satisfactory. Therefore, for optimal results large breasts must be reduced when applying the mesh. If in these instances the remaining breast mass is less than 550 g, good results can be obtained. In patients with gross breast hypertrophy, where more than 1,000 g per breast must be excised, the insertion of mesh will not be beneficial to the patient. It is the first author’s opinion that these patients do better, functionally as well as cosmetically, with a free nipple graft procedure. It is also recommended that overweight patients should obtain a normal body mass index preoperatively to obtain satisfactory results for obvious reasons.
In the many years of performing mastopexy and breast reduction procedures, the first author could never obtain the cosmetic results comparable with those obtainable with the “internal breast support system” technique. The procedure is ideally suited for the post-child-bearing patient with ptotic breasts and an adequate amount of breast tissue. The procedure does not enlarge the breasts but gives the illusion of an enlarged breast due to the more youthful shape and upper-breast fullness obtained. Should the patient request enlargement, fat grafting would be an option to consider 3 months after the insertion of the mesh. This technique avoids the need for augmentation of the upper pole of the breast with silicone prosthesis and the potential risks of combining mastopexy with an augmentation procedure.
The infection complication rate of 0.91% in this series compares well with infection rates when utilizing silicone prostheses. Khan [15] reported infection rates of 1.2% superficial and 0.52% periprosthetic in 3,256 breast augmentations over a period of 10 years. Goés [7] applied mesh in breast procedures and reported on the safety thereof, as did de Bruijn and Johannes [8, 9].
The learning curve for this technique is long due to the care to be taken when anchoring the mesh to obtain optimal results and symmetry; however, the final result is most gratifying to both patient and surgeon. At a later stage (July 2009 to November 2010, not included in this series) a preshaped polyester mesh (Aspide Medical, La Talaudiere, France) was used as well in 22 patients (44 breasts) (Fig. 14). It was easier to implant. The learning curve was shorter and the operating time decreased by approximately 20 min, with an average theatre time of 3 h.

Conclusion

Recurrent breast ptosis can be avoided and satisfactory long-term results can be obtained in mastopexy and breast reduction procedures by reconstructing an internal breast-supporting system with nonabsorbable biocompatible mesh to replace the supportive function of the ligamentous suspension. The surgical procedure is effective and an adjunct to the armamentarium of the plastic surgeon. It is especially indicated in the ptotic breast patient with thin skin of poor quality or in patients with high expectations.

Acknowledgment

The authors thank the South African company Breform Limited, which sponsored the operations on the trial patients, and the Department of Anatomy, University of Stellenbosch, for providing female cadavers for the preoperative research.

Disclosure

P. V. van Deventer has an interest (shares) in Breform Limited. None of the authors have a financial interest or commercial association with the manufacturer of the mesh used in this project.

Open Access

This article is distributed under the terms of the Creative Commons Attribution Noncommercial License which permits any noncommercial use, distribution, and reproduction in any medium, provided the original author(s) and source are credited.
Open AccessThis is an open access article distributed under the terms of the Creative Commons Attribution Noncommercial License (https://​creativecommons.​org/​licenses/​by-nc/​2.​0), which permits any noncommercial use, distribution, and reproduction in any medium, provided the original author(s) and source are credited.

Unsere Produktempfehlungen

Die Chirurgie

Print-Titel

Das Abo mit mehr Tiefe

Mit der Zeitschrift Die Chirurgie erhalten Sie zusätzlich Online-Zugriff auf weitere 43 chirurgische Fachzeitschriften, CME-Fortbildungen, Webinare, Vorbereitungskursen zur Facharztprüfung und die digitale Enzyklopädie e.Medpedia.

Bis 30. April 2024 bestellen und im ersten Jahr nur 199 € zahlen!

e.Med Interdisziplinär

Kombi-Abonnement

Für Ihren Erfolg in Klinik und Praxis - Die beste Hilfe in Ihrem Arbeitsalltag

Mit e.Med Interdisziplinär erhalten Sie Zugang zu allen CME-Fortbildungen und Fachzeitschriften auf SpringerMedizin.de.

e.Dent – Das Online-Abo der Zahnmedizin

Online-Abonnement

Mit e.Dent erhalten Sie Zugang zu allen zahnmedizinischen Fortbildungen und unseren zahnmedizinischen und ausgesuchten medizinischen Zeitschriften.

Literatur
1.
Zurück zum Zitat Bustos RA (1992) Periareolar mammaplasty with silicone supporting lamina. Plast Reconstr Surg 89:646–657PubMedCrossRef Bustos RA (1992) Periareolar mammaplasty with silicone supporting lamina. Plast Reconstr Surg 89:646–657PubMedCrossRef
2.
Zurück zum Zitat Johnson GW (1981) Central core reduction mammoplasties and Marlex suspension of breast tissue. Aesthet Plast Surg 5:77–84CrossRef Johnson GW (1981) Central core reduction mammoplasties and Marlex suspension of breast tissue. Aesthet Plast Surg 5:77–84CrossRef
3.
Zurück zum Zitat Goés JC (1998) Periareolar mastopexy and reduction with mesh support–double skin technique. In: Surgery of the Breast: Principles and Art. Lippincott-Raven Publishers, Philadelphia, pp 697–707 Goés JC (1998) Periareolar mastopexy and reduction with mesh support–double skin technique. In: Surgery of the Breast: Principles and Art. Lippincott-Raven Publishers, Philadelphia, pp 697–707
4.
Zurück zum Zitat Goés JC (1996) Periareolar mammaplasty. Double skin technique with application of polyglactin or mixed mesh. Plast Reconstr Surg 97:959–968PubMedCrossRef Goés JC (1996) Periareolar mammaplasty. Double skin technique with application of polyglactin or mixed mesh. Plast Reconstr Surg 97:959–968PubMedCrossRef
5.
Zurück zum Zitat Goés JC (2002) Periareolar mammaplasty. Double-skin technique with application of mesh support. Clin Plast Surg 29:349–364CrossRef Goés JC (2002) Periareolar mammaplasty. Double-skin technique with application of mesh support. Clin Plast Surg 29:349–364CrossRef
6.
Zurück zum Zitat Goés JC (2003) Periareolar mammaplasty. Double skin technique with mesh support. Aesthet Surg J 23:129–135PubMedCrossRef Goés JC (2003) Periareolar mammaplasty. Double skin technique with mesh support. Aesthet Surg J 23:129–135PubMedCrossRef
7.
Zurück zum Zitat Goés JC, Godoy PM, Goes RS, Henriques LJ, Landecker A, Lyra EC (2004) The application of mesh support in periareolar breast surgery: clinical and mammographic evaluation. Aesthet Plast Surg 28:268–274CrossRef Goés JC, Godoy PM, Goes RS, Henriques LJ, Landecker A, Lyra EC (2004) The application of mesh support in periareolar breast surgery: clinical and mammographic evaluation. Aesthet Plast Surg 28:268–274CrossRef
8.
Zurück zum Zitat De Bruijn HP, Johannes S (2008) Mastopexy with 3D preshaped mesh for long-term results: development of the internal bra system. Aesthet Plast Surg 32:757–765CrossRef De Bruijn HP, Johannes S (2008) Mastopexy with 3D preshaped mesh for long-term results: development of the internal bra system. Aesthet Plast Surg 32:757–765CrossRef
9.
Zurück zum Zitat De Bruijn HP, Ten Thije RHW, Johannes S (2009) Mastopexy with mesh reinforcement: the mechanical characteristics of polyester mesh in the female breast. Plast Reconstr Surg 124:364–371PubMedCrossRef De Bruijn HP, Ten Thije RHW, Johannes S (2009) Mastopexy with mesh reinforcement: the mechanical characteristics of polyester mesh in the female breast. Plast Reconstr Surg 124:364–371PubMedCrossRef
10.
Zurück zum Zitat Würinger E, Mader N, Posch E, Holle J (1998) Nerve and vessel supplying ligamentous suspension of the mammary gland. Plast Reconstr Surg 101:1486–1493PubMedCrossRef Würinger E, Mader N, Posch E, Holle J (1998) Nerve and vessel supplying ligamentous suspension of the mammary gland. Plast Reconstr Surg 101:1486–1493PubMedCrossRef
11.
Zurück zum Zitat Würinger E, Tschabitscher M (2002) New aspects of the topographical anatomy of the mammary gland regarding its neurovascular supply along a regular ligamentous suspension. Eur J Morphol 40:181–189CrossRef Würinger E, Tschabitscher M (2002) New aspects of the topographical anatomy of the mammary gland regarding its neurovascular supply along a regular ligamentous suspension. Eur J Morphol 40:181–189CrossRef
12.
Zurück zum Zitat van Deventer PV (2004) The blood supply to the nipple-areola complex of the human mammary gland. Aesthet Plast Surg 28:393–398CrossRef van Deventer PV (2004) The blood supply to the nipple-areola complex of the human mammary gland. Aesthet Plast Surg 28:393–398CrossRef
13.
Zurück zum Zitat van Deventer PV, Page BJ, Graewe FR (2008) The safety of pedicles in breast reduction and mastopexy procedures. Aesthet Plast Surg 32:307–312CrossRef van Deventer PV, Page BJ, Graewe FR (2008) The safety of pedicles in breast reduction and mastopexy procedures. Aesthet Plast Surg 32:307–312CrossRef
14.
Zurück zum Zitat van Deventer PV, Graewe FR (2010) Enhanching pedicle safety in mastopexy and breast reduction procedures: the posteroinferomedial pedicle, retaining the medial vertical ligament of Würinger. Plast Reconstr Surg 126:786–793PubMedCrossRef van Deventer PV, Graewe FR (2010) Enhanching pedicle safety in mastopexy and breast reduction procedures: the posteroinferomedial pedicle, retaining the medial vertical ligament of Würinger. Plast Reconstr Surg 126:786–793PubMedCrossRef
15.
Zurück zum Zitat Khan UD (2010) Breast augmentation, antibiotic prophylaxis, and infection: comparative analysis of 1, 628 primary augmentation mammoplasties assessing the role and efficacy of antibiotics prophylaxis duration. Aesthet Plast Surg 34:42–47CrossRef Khan UD (2010) Breast augmentation, antibiotic prophylaxis, and infection: comparative analysis of 1, 628 primary augmentation mammoplasties assessing the role and efficacy of antibiotics prophylaxis duration. Aesthet Plast Surg 34:42–47CrossRef
Metadaten
Titel
Improving the Longevity and Results of Mastopexy and Breast Reduction Procedures: Reconstructing an Internal Breast Support System with Biocompatible Mesh to Replace the Supporting Function of the Ligamentous Suspension
verfasst von
Petrus V. van Deventer
Frank R. Graewe
Elisabeth Würinger
Publikationsdatum
01.06.2012
Verlag
Springer-Verlag
Erschienen in
Aesthetic Plastic Surgery / Ausgabe 3/2012
Print ISSN: 0364-216X
Elektronische ISSN: 1432-5241
DOI
https://doi.org/10.1007/s00266-011-9845-2

Weitere Artikel der Ausgabe 3/2012

Aesthetic Plastic Surgery 3/2012 Zur Ausgabe

Update Chirurgie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.

S3-Leitlinie „Diagnostik und Therapie des Karpaltunnelsyndroms“

CME: 2 Punkte

Prof. Dr. med. Gregor Antoniadis Das Karpaltunnelsyndrom ist die häufigste Kompressionsneuropathie peripherer Nerven. Obwohl die Anamnese mit dem nächtlichen Einschlafen der Hand (Brachialgia parästhetica nocturna) sehr typisch ist, ist eine klinisch-neurologische Untersuchung und Elektroneurografie in manchen Fällen auch eine Neurosonografie erforderlich. Im Anfangsstadium sind konservative Maßnahmen (Handgelenksschiene, Ergotherapie) empfehlenswert. Bei nicht Ansprechen der konservativen Therapie oder Auftreten von neurologischen Ausfällen ist eine Dekompression des N. medianus am Karpaltunnel indiziert.

Prof. Dr. med. Gregor Antoniadis
Berufsverband der Deutschen Chirurgie e.V.

S2e-Leitlinie „Distale Radiusfraktur“

CME: 2 Punkte

Dr. med. Benjamin Meyknecht, PD Dr. med. Oliver Pieske Das Webinar S2e-Leitlinie „Distale Radiusfraktur“ beschäftigt sich mit Fragen und Antworten zu Diagnostik und Klassifikation sowie Möglichkeiten des Ausschlusses von Zusatzverletzungen. Die Referenten erläutern, welche Frakturen konservativ behandelt werden können und wie. Das Webinar beantwortet die Frage nach aktuellen operativen Therapiekonzepten: Welcher Zugang, welches Osteosynthesematerial? Auf was muss bei der Nachbehandlung der distalen Radiusfraktur geachtet werden?

PD Dr. med. Oliver Pieske
Dr. med. Benjamin Meyknecht
Berufsverband der Deutschen Chirurgie e.V.

S1-Leitlinie „Empfehlungen zur Therapie der akuten Appendizitis bei Erwachsenen“

CME: 2 Punkte

Dr. med. Mihailo Andric
Inhalte des Webinars zur S1-Leitlinie „Empfehlungen zur Therapie der akuten Appendizitis bei Erwachsenen“ sind die Darstellung des Projektes und des Erstellungswegs zur S1-Leitlinie, die Erläuterung der klinischen Relevanz der Klassifikation EAES 2015, die wissenschaftliche Begründung der wichtigsten Empfehlungen und die Darstellung stadiengerechter Therapieoptionen.

Dr. med. Mihailo Andric
Berufsverband der Deutschen Chirurgie e.V.