Skip to main content
Erschienen in: World Journal of Surgery 8/2006

01.08.2006

Experimental Comparison of Monofile Light and Heavy Polypropylene Meshes: Less Weight Does Not Mean Less Biological Response

verfasst von: Dirk Weyhe, MD, Inge Schmitz, PhD, Orlin Belyaev, MD, Robert Grabs, Klaus-Michael Müller, MD, Waldemar Uhl, MD, Volker Zumtobel, MD

Erschienen in: World Journal of Surgery | Ausgabe 8/2006

Einloggen, um Zugang zu erhalten

Abstract

Background

Mesh implantation is a standard procedure in hernia repair. It provides low recurrence rate but increases complication rate due to foreign-body reaction induced by alloplastic materials in surrounding tissues. It is believed that biocompatibility of meshes may be improved by reducing their weight per meter squared (m2) and altering the implant structure.

Aim

The aim of this study was to evaluate the effect of weight and structure as determinants of mesh biocompatibility.

Method

Thirty-six Wistar rats were studied. In 12 animals, conventional polypropylene (heavy) meshes (HM) were implanted; in other 12, material-reduced (light) microporous polypropylene meshes (LM); and the remaining 12 served as a sham-operated control group. Meshes were explanted after 21 and 90 days (6 animals per group). All samples were examined by light and electron microscopies. Integration of meshes in surrounding tissue, inflammatory response, fibrotic reactions, and structural changes were recorded. Quantification of the inflammatory response was achieved by CD-68 marking of macrophages and counting their number per surface unit.

Results

After 21 days, there was no significant difference in thickness of surrounding connective tissue between meshes in all groups studied. After 90 days, thickness of connective tissue decreased in both groups, and fibrotic reaction in the mesh bed was significantly less in the HM group. Total amount of macrophages per millimeter squared (mm2) decreased with time in HM and LM samples but was significantly lower in the HM group on day 21 (43.5%) and day 90 (46.7%).

Conclusion

This study found worse biocompatibility of LM compared with HM. Thus, the amount of implanted mesh was not the main determinant of biocompatibility (expressed as successful incorporation and diminished foreign-body reaction) but the size of the pores.
Literatur
1.
Zurück zum Zitat Schumpelick V, Klinge U, Welty G, et al. Meshes in the abdominal wall. Chirurg 1999;70:876–887PubMedCrossRef Schumpelick V, Klinge U, Welty G, et al. Meshes in the abdominal wall. Chirurg 1999;70:876–887PubMedCrossRef
2.
Zurück zum Zitat Morris-Stiff GJ, Hughes LE. The outcomes of nonabsorbable mesh placed within the abdominal cavity: literature review and clinical experience. J Am Coll Surg 1998;186(3):352–367PubMedCrossRef Morris-Stiff GJ, Hughes LE. The outcomes of nonabsorbable mesh placed within the abdominal cavity: literature review and clinical experience. J Am Coll Surg 1998;186(3):352–367PubMedCrossRef
3.
Zurück zum Zitat Schumpelick V, Conze J, Klinge U. Preperitoneal mesh-plasty in incisional hernia repair. A comparative retrospective study of 272 operated incisional hernias. Chirurg 1996;67:1028–1035PubMedCrossRef Schumpelick V, Conze J, Klinge U. Preperitoneal mesh-plasty in incisional hernia repair. A comparative retrospective study of 272 operated incisional hernias. Chirurg 1996;67:1028–1035PubMedCrossRef
4.
Zurück zum Zitat Bellon JM, Bujan J, Contreras L, et al. Integration of biomaterials implanted into abdominal wall: process of scar formation and macrophage response. Biomaterials 1995;16:381–387PubMedCrossRef Bellon JM, Bujan J, Contreras L, et al. Integration of biomaterials implanted into abdominal wall: process of scar formation and macrophage response. Biomaterials 1995;16:381–387PubMedCrossRef
5.
Zurück zum Zitat Nyhus LM. Ubiquitous use of prosthetic mesh in inguinal hernia repair: the dilemma. Hernia 2000;4:184–186CrossRef Nyhus LM. Ubiquitous use of prosthetic mesh in inguinal hernia repair: the dilemma. Hernia 2000;4:184–186CrossRef
6.
Zurück zum Zitat Bittner R, Leibl B, Kraft K, et al. The laparoscopic hernioplasty (TAPP) – complications and recurrences of 900 operations. Zentralbl Chir 1996;121:313–319PubMed Bittner R, Leibl B, Kraft K, et al. The laparoscopic hernioplasty (TAPP) – complications and recurrences of 900 operations. Zentralbl Chir 1996;121:313–319PubMed
7.
Zurück zum Zitat Hofbauer C, Anderson PV, Juul P. Late mesh rejection as a complication to transabdominal preperitoneal laparoscopic hernia repair. Surg Endosc 1998;12:1164–1165PubMedCrossRef Hofbauer C, Anderson PV, Juul P. Late mesh rejection as a complication to transabdominal preperitoneal laparoscopic hernia repair. Surg Endosc 1998;12:1164–1165PubMedCrossRef
8.
Zurück zum Zitat O’Dwyer PJ, Kingsnorth AN, Molloy RG et al. Randomized clinical trial assessing impact of a lightweight or heavyweight mesh on chronic pain after inguinal hernia repair. Br J Surg 2005;92:166–170PubMedCrossRef O’Dwyer PJ, Kingsnorth AN, Molloy RG et al. Randomized clinical trial assessing impact of a lightweight or heavyweight mesh on chronic pain after inguinal hernia repair. Br J Surg 2005;92:166–170PubMedCrossRef
9.
Zurück zum Zitat Klosterhalfen B, Klinge U, Henze U, et al. Morphological correlation of the functional mechanics of the abdominal wall after mesh implantation. Langenbecks Arch Surg 1997;382:87–94 Klosterhalfen B, Klinge U, Henze U, et al. Morphological correlation of the functional mechanics of the abdominal wall after mesh implantation. Langenbecks Arch Surg 1997;382:87–94
10.
Zurück zum Zitat Schumpelick V, Klosterhalfen B, Müller M, et al. Minimized polypropylene mesh for preperitoneal net plasty (PNP) of incisional hernias. Chirurg 1999;70:422–430PubMedCrossRef Schumpelick V, Klosterhalfen B, Müller M, et al. Minimized polypropylene mesh for preperitoneal net plasty (PNP) of incisional hernias. Chirurg 1999;70:422–430PubMedCrossRef
11.
Zurück zum Zitat Coda A, Botto-Micca F, Quaglino F, et al. In vivo tissue reaction to different prosthetic materials in abdominal wall hernia repair. Hernia 2000;4:206–211CrossRef Coda A, Botto-Micca F, Quaglino F, et al. In vivo tissue reaction to different prosthetic materials in abdominal wall hernia repair. Hernia 2000;4:206–211CrossRef
12.
Zurück zum Zitat Klinge U, Klosterhalfen B, Muller M, et al. Foreign body reaction to meshes used for the repair of abdominal wall hernias. Eur J Surg 1999;165:665–673PubMedCrossRef Klinge U, Klosterhalfen B, Muller M, et al. Foreign body reaction to meshes used for the repair of abdominal wall hernias. Eur J Surg 1999;165:665–673PubMedCrossRef
13.
Zurück zum Zitat Fölscher DJ, Jamali FR, Leroy J, et al. Utility of a new soft, non-woven polypropylene mesh for the transabdominal extraperitoneal laparoscopic hernia repair: preliminary results. Hernia 2000;4:228–233CrossRef Fölscher DJ, Jamali FR, Leroy J, et al. Utility of a new soft, non-woven polypropylene mesh for the transabdominal extraperitoneal laparoscopic hernia repair: preliminary results. Hernia 2000;4:228–233CrossRef
14.
Zurück zum Zitat Junge K, Klinge U, Prescher A, et al. Elasticity of the anterior abdominal wall and impact for reparation of incisional hernias using mesh implants. Hernia 2001;5:113–118PubMedCrossRef Junge K, Klinge U, Prescher A, et al. Elasticity of the anterior abdominal wall and impact for reparation of incisional hernias using mesh implants. Hernia 2001;5:113–118PubMedCrossRef
15.
Zurück zum Zitat Klinge U, Junge K, Stumpf M, et al. Functional and morphological evaluation of a low-weight, monofilament polypropylene mesh for hernia repair. J Biomed Mater Res 2002;63:129–136PubMedCrossRef Klinge U, Junge K, Stumpf M, et al. Functional and morphological evaluation of a low-weight, monofilament polypropylene mesh for hernia repair. J Biomed Mater Res 2002;63:129–136PubMedCrossRef
16.
Zurück zum Zitat Klinge U, Klosterhalfen B, Müller M, et al. Shrinking of polypropylene mesh in vivo: an experimental study in dogs. Eur J Surg 1998;164:965–969PubMedCrossRef Klinge U, Klosterhalfen B, Müller M, et al. Shrinking of polypropylene mesh in vivo: an experimental study in dogs. Eur J Surg 1998;164:965–969PubMedCrossRef
17.
Zurück zum Zitat Greca FH, de Paula JB, Biondo-Simoes ML, et al. The influence of differing pore sizes on the biocompatibility of two polypropylene meshes in the repair of abdominal defects. Hernia 2001;5:59–64PubMedCrossRef Greca FH, de Paula JB, Biondo-Simoes ML, et al. The influence of differing pore sizes on the biocompatibility of two polypropylene meshes in the repair of abdominal defects. Hernia 2001;5:59–64PubMedCrossRef
18.
Zurück zum Zitat Klinge U, Klosterhalfen B, Birkenhauer V, et al. Impact of polymer pore size on the interface scar formation in a rat model. J Surg Res 2002;103:208–214PubMedCrossRef Klinge U, Klosterhalfen B, Birkenhauer V, et al. Impact of polymer pore size on the interface scar formation in a rat model. J Surg Res 2002;103:208–214PubMedCrossRef
19.
Zurück zum Zitat Rutkow IM, Freehold NJ. The recurrence rate in hernia surgery-how important is it? Arch Surg 1995;130:575–576PubMed Rutkow IM, Freehold NJ. The recurrence rate in hernia surgery-how important is it? Arch Surg 1995;130:575–576PubMed
Metadaten
Titel
Experimental Comparison of Monofile Light and Heavy Polypropylene Meshes: Less Weight Does Not Mean Less Biological Response
verfasst von
Dirk Weyhe, MD
Inge Schmitz, PhD
Orlin Belyaev, MD
Robert Grabs
Klaus-Michael Müller, MD
Waldemar Uhl, MD
Volker Zumtobel, MD
Publikationsdatum
01.08.2006
Erschienen in
World Journal of Surgery / Ausgabe 8/2006
Print ISSN: 0364-2313
Elektronische ISSN: 1432-2323
DOI
https://doi.org/10.1007/s00268-005-0601-0

Weitere Artikel der Ausgabe 8/2006

World Journal of Surgery 8/2006 Zur Ausgabe

Update Chirurgie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.

S3-Leitlinie „Diagnostik und Therapie des Karpaltunnelsyndroms“

Karpaltunnelsyndrom BDC Leitlinien Webinare
CME: 2 Punkte

Das Karpaltunnelsyndrom ist die häufigste Kompressionsneuropathie peripherer Nerven. Obwohl die Anamnese mit dem nächtlichen Einschlafen der Hand (Brachialgia parästhetica nocturna) sehr typisch ist, ist eine klinisch-neurologische Untersuchung und Elektroneurografie in manchen Fällen auch eine Neurosonografie erforderlich. Im Anfangsstadium sind konservative Maßnahmen (Handgelenksschiene, Ergotherapie) empfehlenswert. Bei nicht Ansprechen der konservativen Therapie oder Auftreten von neurologischen Ausfällen ist eine Dekompression des N. medianus am Karpaltunnel indiziert.

Prof. Dr. med. Gregor Antoniadis
Berufsverband der Deutschen Chirurgie e.V.

S2e-Leitlinie „Distale Radiusfraktur“

Radiusfraktur BDC Leitlinien Webinare
CME: 2 Punkte

Das Webinar beschäftigt sich mit Fragen und Antworten zu Diagnostik und Klassifikation sowie Möglichkeiten des Ausschlusses von Zusatzverletzungen. Die Referenten erläutern, welche Frakturen konservativ behandelt werden können und wie. Das Webinar beantwortet die Frage nach aktuellen operativen Therapiekonzepten: Welcher Zugang, welches Osteosynthesematerial? Auf was muss bei der Nachbehandlung der distalen Radiusfraktur geachtet werden?

PD Dr. med. Oliver Pieske
Dr. med. Benjamin Meyknecht
Berufsverband der Deutschen Chirurgie e.V.

S1-Leitlinie „Empfehlungen zur Therapie der akuten Appendizitis bei Erwachsenen“

Appendizitis BDC Leitlinien Webinare
CME: 2 Punkte

Inhalte des Webinars zur S1-Leitlinie „Empfehlungen zur Therapie der akuten Appendizitis bei Erwachsenen“ sind die Darstellung des Projektes und des Erstellungswegs zur S1-Leitlinie, die Erläuterung der klinischen Relevanz der Klassifikation EAES 2015, die wissenschaftliche Begründung der wichtigsten Empfehlungen und die Darstellung stadiengerechter Therapieoptionen.

Dr. med. Mihailo Andric
Berufsverband der Deutschen Chirurgie e.V.