Skip to main content
Erschienen in: World Journal of Surgery 6/2016

27.01.2016 | Original Scientific Report

Severity of Recurrent Laryngeal Nerve Injuries in Thyroid Surgery

verfasst von: Gianlorenzo Dionigi, Che-Wei Wu, Hoon Yub Kim, Stefano Rausei, Luigi Boni, Feng-Yu Chiang

Erschienen in: World Journal of Surgery | Ausgabe 6/2016

Einloggen, um Zugang zu erhalten

Abstract

Background

Few studies in the literature have reported recovery data for different types of recurrent laryngeal nerve injuries (RLNIs). This study is the first attempt to classify RLNIs and rank them by severity.

Methods

This prospective clinical study analyzed 281 RLNIs in which a true loss of signal was identified by intraoperative neuromonitoring (IONM), and vocal cord palsy (VCP) was confirmed by a postoperative laryngoscope. For each injury type, the prevalence of VCP, the time of VCP recovery, and physical changes on nerves were analyzed. Additionally, different RLNI types were experimentally induced in a porcine model to compare morphological change.

Results

The overall VCP rate in at-risk patients/nerves was 8.9/4.6 %, respectively. The distribution of RLNI types, in order of frequency, was traction (71 %), thermal (17 %), compression (4.2 %), clamping (3.4 %), ligature entrapment (1.6 %), suction (1.4 %), and nerve transection (1.4 %). Complete recovery from VCP was documented in 91 % of RLNIs. Recovery time was significantly faster in the traction group compared to the other groups (p < 0.001). The rates of temporary and permanent VCP were 98.6 and 1.4 % for traction lesion, 72 and 28 % for thermal injury, 100 and 0 % for compression injury, 50 and 50 % for clamping injury, 100 and 0 % for ligature entrapment, 100 and 0 % for suction injury, and 0 and 100 % for nerve transection, respectively. Physical changes were noted in 14 % of RLNIs in which 56 % of VCP was permanent. However, among the remaining 86 % IONM-detectable RLNIs without physical changes, only 1.2 % of VCP was permanent. A porcine model of traction lesion showed only distorted outer nerve structure, whereas the thermal lesion showed severe damage in the inner endoneurium.

Conclusions

Different RNLIs induce different morphological alterations and have different recovery outcomes. Permanent VCP is rare in lesions that are visually undetectable but detectable by IONM. By enabling early detection of RLNI and prediction of outcome, IONM can help clinicians plan intra- and postoperative treatment.
Literatur
1.
Zurück zum Zitat Randolph GW (2013) Surgery of the thyroid and parathyroid glands. Saunders, Philadelphia Randolph GW (2013) Surgery of the thyroid and parathyroid glands. Saunders, Philadelphia
2.
Zurück zum Zitat Chiang FY, Lu IC, Kuo WR, Lee KW, Chang NC, Wu CW (2008) The mechanism of recurrent laryngeal nerve injury during thyroid surgery–the application of intraoperative neuromonitoring. Surgery 143(6):743–749CrossRefPubMed Chiang FY, Lu IC, Kuo WR, Lee KW, Chang NC, Wu CW (2008) The mechanism of recurrent laryngeal nerve injury during thyroid surgery–the application of intraoperative neuromonitoring. Surgery 143(6):743–749CrossRefPubMed
3.
Zurück zum Zitat Snyder SK, Lairmore TC, Hendricks JC, Roberts JW (2008) Elucidating mechanisms of recurrent laryngeal nerve injury during thyroidectomy and parathyroidectomy. J Am Coll Surg 206(1):123–130CrossRefPubMed Snyder SK, Lairmore TC, Hendricks JC, Roberts JW (2008) Elucidating mechanisms of recurrent laryngeal nerve injury during thyroidectomy and parathyroidectomy. J Am Coll Surg 206(1):123–130CrossRefPubMed
4.
Zurück zum Zitat Chiang FY, Lee KW, Chen HC, Chen HY, Lu IC, Kuo WR, Hsieh MC, Wu CW (2010) Standardization of intraoperative neuromonitoring of recurrent laryngeal nerve in thyroid operation. World J Surg 34(2):223–229CrossRefPubMed Chiang FY, Lee KW, Chen HC, Chen HY, Lu IC, Kuo WR, Hsieh MC, Wu CW (2010) Standardization of intraoperative neuromonitoring of recurrent laryngeal nerve in thyroid operation. World J Surg 34(2):223–229CrossRefPubMed
5.
Zurück zum Zitat Randolph GW, Dralle H, Abdullah H, Barczynski M, Bellantone R, Brauckhoff M, Carnaille B, Cherenko S, Chiang FY, Dionigi G, Finck C, Hartl D, Kamani D, Lorenz K, Miccolli P, Mihai R, Miyauchi A, Orloff L, Perrier N, Poveda MD, Romanchishen A, Serpell J, Sitges-Serra A, Sloan T, Van Slycke S, Snyder S, Takami H, Volpi E, Woodson G (2011) Electrophysiologic recurrent laryngeal nerve monitoring during thyroid and parathyroid surgery: international standards guideline statement. Laryngoscope 121(Suppl 1):S1–S16CrossRefPubMed Randolph GW, Dralle H, Abdullah H, Barczynski M, Bellantone R, Brauckhoff M, Carnaille B, Cherenko S, Chiang FY, Dionigi G, Finck C, Hartl D, Kamani D, Lorenz K, Miccolli P, Mihai R, Miyauchi A, Orloff L, Perrier N, Poveda MD, Romanchishen A, Serpell J, Sitges-Serra A, Sloan T, Van Slycke S, Snyder S, Takami H, Volpi E, Woodson G (2011) Electrophysiologic recurrent laryngeal nerve monitoring during thyroid and parathyroid surgery: international standards guideline statement. Laryngoscope 121(Suppl 1):S1–S16CrossRefPubMed
6.
Zurück zum Zitat Dralle H, Sekulla C, Lorenz K, Brauckhoff M, Machens A (2008) Intraoperative monitoring of the recurrent laryngeal nerve in thyroid surgery. World J Surg 32(7):1358–1366CrossRefPubMed Dralle H, Sekulla C, Lorenz K, Brauckhoff M, Machens A (2008) Intraoperative monitoring of the recurrent laryngeal nerve in thyroid surgery. World J Surg 32(7):1358–1366CrossRefPubMed
7.
Zurück zum Zitat Dionigi G, Barczynski M, Chiang FY, Dralle H, Duran-Poveda M, Iacobone M, Lombardi CP, Materazzi G, Mihai R, Randolph GW, Sitges-Serra A (2010) Why monitor the recurrent laryngeal nerve in thyroid surgery? J Endocrinol Invest 33(11):819–822. doi:10.1007/bf03350349 CrossRefPubMed Dionigi G, Barczynski M, Chiang FY, Dralle H, Duran-Poveda M, Iacobone M, Lombardi CP, Materazzi G, Mihai R, Randolph GW, Sitges-Serra A (2010) Why monitor the recurrent laryngeal nerve in thyroid surgery? J Endocrinol Invest 33(11):819–822. doi:10.​1007/​bf03350349 CrossRefPubMed
8.
Zurück zum Zitat Dionigi G, Alesina PF, Barczynski M, Boni L, Chiang FY, Kim HY, Materazzi G, Randolph GW, Terris DJ, Wu CW (2012) Recurrent laryngeal nerve injury in video-assisted thyroidectomy: lessons learned from neuromonitoring. Surg Endosc 26(9):2601–2608CrossRefPubMed Dionigi G, Alesina PF, Barczynski M, Boni L, Chiang FY, Kim HY, Materazzi G, Randolph GW, Terris DJ, Wu CW (2012) Recurrent laryngeal nerve injury in video-assisted thyroidectomy: lessons learned from neuromonitoring. Surg Endosc 26(9):2601–2608CrossRefPubMed
9.
Zurück zum Zitat Wu CW, Chai YJ, Dionigi G, Chiang FY, Liu X, Sun H, Randolph GW, Tufano RP, Kim HY (2015) Recurrent laryngeal nerve safety parameters of the harmonic focus during thyroid surgery: porcine model using continuous monitoring. Laryngoscope 125(12):2838–2845. doi:10.1002/lary.25412 CrossRefPubMed Wu CW, Chai YJ, Dionigi G, Chiang FY, Liu X, Sun H, Randolph GW, Tufano RP, Kim HY (2015) Recurrent laryngeal nerve safety parameters of the harmonic focus during thyroid surgery: porcine model using continuous monitoring. Laryngoscope 125(12):2838–2845. doi:10.​1002/​lary.​25412 CrossRefPubMed
10.
Zurück zum Zitat Wu CW, Dionigi G, Sun H, Liu X, Kim HY, Hsiao PJ, Tsai KB, Chen HC, Chen HY, Chang PY, Lu IC, Chiang FY (2014) Intraoperative neuromonitoring for the early detection and prevention of RLN traction injury in thyroid surgery: a porcine model. Surgery 155(2):329–339CrossRefPubMed Wu CW, Dionigi G, Sun H, Liu X, Kim HY, Hsiao PJ, Tsai KB, Chen HC, Chen HY, Chang PY, Lu IC, Chiang FY (2014) Intraoperative neuromonitoring for the early detection and prevention of RLN traction injury in thyroid surgery: a porcine model. Surgery 155(2):329–339CrossRefPubMed
11.
Zurück zum Zitat Lin YC, Dionigi G, Randolph GW, Lu IC, Chang PY, Tsai SY, Kim HY, Lee HY, Tufano RP, Sun H, Liu X, Chiang FY, Wu CW (2015) Electrophysiologic monitoring correlates of recurrent laryngeal nerve heat thermal injury in a porcine model. Laryngoscope 125(8):E283–E290. doi:10.1002/lary.25362 CrossRefPubMed Lin YC, Dionigi G, Randolph GW, Lu IC, Chang PY, Tsai SY, Kim HY, Lee HY, Tufano RP, Sun H, Liu X, Chiang FY, Wu CW (2015) Electrophysiologic monitoring correlates of recurrent laryngeal nerve heat thermal injury in a porcine model. Laryngoscope 125(8):E283–E290. doi:10.​1002/​lary.​25362 CrossRefPubMed
12.
Zurück zum Zitat Puram SV, Chow H, Wu CW, Heaton JT, Kamani D, Gorti G, Chiang FY, Dionigi G, Barczynski M, Schneider R, Dralle H, Lorenz K, Randolph GW (2015) Vocal cord paralysis predicted by neural monitoring electrophysiologic changes with recurrent laryngeal nerve compressive neuropraxic injury in a canine model. Head Neck. doi:10.1002/hed.24225 PubMed Puram SV, Chow H, Wu CW, Heaton JT, Kamani D, Gorti G, Chiang FY, Dionigi G, Barczynski M, Schneider R, Dralle H, Lorenz K, Randolph GW (2015) Vocal cord paralysis predicted by neural monitoring electrophysiologic changes with recurrent laryngeal nerve compressive neuropraxic injury in a canine model. Head Neck. doi:10.​1002/​hed.​24225 PubMed
13.
Zurück zum Zitat Dionigi G, Bacuzzi A, Boni L, Rovera F, Dionigi R (2008) What is the learning curve for intraoperative neuromonitoring in thyroid surgery? Int J Surg 6(Suppl 1):S7–12CrossRefPubMed Dionigi G, Bacuzzi A, Boni L, Rovera F, Dionigi R (2008) What is the learning curve for intraoperative neuromonitoring in thyroid surgery? Int J Surg 6(Suppl 1):S7–12CrossRefPubMed
14.
Zurück zum Zitat Dralle H, Sekulla C, Lorenz K, Thanh PN, Schneider R, Machens A (2012) Loss of the nerve monitoring signal during bilateral thyroid surgery. Br J Surg 99(8):1089–1095CrossRefPubMed Dralle H, Sekulla C, Lorenz K, Thanh PN, Schneider R, Machens A (2012) Loss of the nerve monitoring signal during bilateral thyroid surgery. Br J Surg 99(8):1089–1095CrossRefPubMed
15.
Zurück zum Zitat Dionigi G, Chiang FY, Hui S, Wu CW, Xiaoli L, Ferrari CC, Mangano A, Lianos GD, Leotta A, Lavazza M, Frattini F, Annoni M, Rausei S, Boni L, Kim HY (2015) Continuous intraoperative neuromonitoring (C-IONM) technique with the automatic periodic stimulating (APS) accessory for conventional and endoscopic thyroid surgery. Surg Technol Int 26:101–114PubMed Dionigi G, Chiang FY, Hui S, Wu CW, Xiaoli L, Ferrari CC, Mangano A, Lianos GD, Leotta A, Lavazza M, Frattini F, Annoni M, Rausei S, Boni L, Kim HY (2015) Continuous intraoperative neuromonitoring (C-IONM) technique with the automatic periodic stimulating (APS) accessory for conventional and endoscopic thyroid surgery. Surg Technol Int 26:101–114PubMed
16.
Zurück zum Zitat Dionigi G, Boni L, Rovera F, Rausei S, Castelnuovo P, Dionigi R (2010) Postoperative laryngoscopy in thyroid surgery: proper timing to detect recurrent laryngeal nerve injury. Langenbeck’s Arch Surg 395(4):327–331. doi:10.1007/s00423-009-0581-x CrossRef Dionigi G, Boni L, Rovera F, Rausei S, Castelnuovo P, Dionigi R (2010) Postoperative laryngoscopy in thyroid surgery: proper timing to detect recurrent laryngeal nerve injury. Langenbeck’s Arch Surg 395(4):327–331. doi:10.​1007/​s00423-009-0581-x CrossRef
17.
Zurück zum Zitat Dionigi G (2009) Energy based devices and recurrent laryngeal nerve injury: the need for safer instruments. Langenbeck’s Arch Surg 394(3):579–580 author reply 581-576 CrossRef Dionigi G (2009) Energy based devices and recurrent laryngeal nerve injury: the need for safer instruments. Langenbeck’s Arch Surg 394(3):579–580 author reply 581-576 CrossRef
18.
Zurück zum Zitat Wang LF, Lee KW, Kuo WR, Wu CW, Lu SP, Chiang FY (2006) The efficacy of intraoperative corticosteroids in recurrent laryngeal nerve palsy after thyroid surgery. World J Surg 30(3):299–303CrossRefPubMed Wang LF, Lee KW, Kuo WR, Wu CW, Lu SP, Chiang FY (2006) The efficacy of intraoperative corticosteroids in recurrent laryngeal nerve palsy after thyroid surgery. World J Surg 30(3):299–303CrossRefPubMed
19.
Zurück zum Zitat Bacuzzi A, Dralle H, Randolph GW, Chiang FY, Kim HY, Barczynski M, Dionigi G (2015) Safety of continuous intraoperative neuromonitoring (C-IONM) in thyroid surgery. World J Surg. doi:10.1007/s00268-015-3288-x Bacuzzi A, Dralle H, Randolph GW, Chiang FY, Kim HY, Barczynski M, Dionigi G (2015) Safety of continuous intraoperative neuromonitoring (C-IONM) in thyroid surgery. World J Surg. doi:10.​1007/​s00268-015-3288-x
20.
Zurück zum Zitat Phelan E, Schneider R, Lorenz K, Dralle H, Kamani D, Potenza A, Sritharan N, Shin J, Randolph WG (2014) Continuous vagal IONM prevents recurrent laryngeal nerve paralysis by revealing initial EMG changes of impending neuropraxic injury: a prospective, multicenter study. Laryngoscope 124(6):1498–1505. doi:10.1002/lary.24550 CrossRefPubMed Phelan E, Schneider R, Lorenz K, Dralle H, Kamani D, Potenza A, Sritharan N, Shin J, Randolph WG (2014) Continuous vagal IONM prevents recurrent laryngeal nerve paralysis by revealing initial EMG changes of impending neuropraxic injury: a prospective, multicenter study. Laryngoscope 124(6):1498–1505. doi:10.​1002/​lary.​24550 CrossRefPubMed
21.
Zurück zum Zitat Schneider R, Bures C, Lorenz K, Dralle H, Freissmuth M, Hermann M (2013) Evolution of nerve injury with unexpected EMG signal recovery in thyroid surgery using continuous intraoperative neuromonitoring. World J Surg 37(2):364–368CrossRefPubMed Schneider R, Bures C, Lorenz K, Dralle H, Freissmuth M, Hermann M (2013) Evolution of nerve injury with unexpected EMG signal recovery in thyroid surgery using continuous intraoperative neuromonitoring. World J Surg 37(2):364–368CrossRefPubMed
Metadaten
Titel
Severity of Recurrent Laryngeal Nerve Injuries in Thyroid Surgery
verfasst von
Gianlorenzo Dionigi
Che-Wei Wu
Hoon Yub Kim
Stefano Rausei
Luigi Boni
Feng-Yu Chiang
Publikationsdatum
27.01.2016
Verlag
Springer International Publishing
Erschienen in
World Journal of Surgery / Ausgabe 6/2016
Print ISSN: 0364-2313
Elektronische ISSN: 1432-2323
DOI
https://doi.org/10.1007/s00268-016-3415-3

Weitere Artikel der Ausgabe 6/2016

World Journal of Surgery 6/2016 Zur Ausgabe

Update Chirurgie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.

S3-Leitlinie „Diagnostik und Therapie des Karpaltunnelsyndroms“

CME: 2 Punkte

Prof. Dr. med. Gregor Antoniadis Das Karpaltunnelsyndrom ist die häufigste Kompressionsneuropathie peripherer Nerven. Obwohl die Anamnese mit dem nächtlichen Einschlafen der Hand (Brachialgia parästhetica nocturna) sehr typisch ist, ist eine klinisch-neurologische Untersuchung und Elektroneurografie in manchen Fällen auch eine Neurosonografie erforderlich. Im Anfangsstadium sind konservative Maßnahmen (Handgelenksschiene, Ergotherapie) empfehlenswert. Bei nicht Ansprechen der konservativen Therapie oder Auftreten von neurologischen Ausfällen ist eine Dekompression des N. medianus am Karpaltunnel indiziert.

Prof. Dr. med. Gregor Antoniadis
Berufsverband der Deutschen Chirurgie e.V.

S2e-Leitlinie „Distale Radiusfraktur“

CME: 2 Punkte

Dr. med. Benjamin Meyknecht, PD Dr. med. Oliver Pieske Das Webinar S2e-Leitlinie „Distale Radiusfraktur“ beschäftigt sich mit Fragen und Antworten zu Diagnostik und Klassifikation sowie Möglichkeiten des Ausschlusses von Zusatzverletzungen. Die Referenten erläutern, welche Frakturen konservativ behandelt werden können und wie. Das Webinar beantwortet die Frage nach aktuellen operativen Therapiekonzepten: Welcher Zugang, welches Osteosynthesematerial? Auf was muss bei der Nachbehandlung der distalen Radiusfraktur geachtet werden?

PD Dr. med. Oliver Pieske
Dr. med. Benjamin Meyknecht
Berufsverband der Deutschen Chirurgie e.V.

S1-Leitlinie „Empfehlungen zur Therapie der akuten Appendizitis bei Erwachsenen“

CME: 2 Punkte

Dr. med. Mihailo Andric
Inhalte des Webinars zur S1-Leitlinie „Empfehlungen zur Therapie der akuten Appendizitis bei Erwachsenen“ sind die Darstellung des Projektes und des Erstellungswegs zur S1-Leitlinie, die Erläuterung der klinischen Relevanz der Klassifikation EAES 2015, die wissenschaftliche Begründung der wichtigsten Empfehlungen und die Darstellung stadiengerechter Therapieoptionen.

Dr. med. Mihailo Andric
Berufsverband der Deutschen Chirurgie e.V.