Abstract

Introduction

In meta-analyses and systematic reviews, clear advantages have been identified for the sublay versus onlay technique for treatment of incisional hernias. Nonetheless, an expert panel has noted that the onlay mesh location may be useful in certain settings.

Materials and methods

First, unadjusted analysis of data from the Herniamed Registry was performed to compare 6797 sublay operations with 1024 onlay operations for repair of incisional hernias. Then, using propensity score matching to account for the influence of variables age, gender, ASA score, BMI, risk factors, preoperative pain, defect size, and defect localization, 1016 pairs were formed and compared with each other.

Results

Unadjusted analysis revealed that the onlay operation was used significantly more often for small defects, lateral defect localization, and in women. After comparing the propensity score-matched pairs, no significant difference was found between the sublay and onlay technique in the outcome criteria intra- and postoperative complications, general complications, complication-related reoperations, pain at rest, pain on exertion, chronic pain requiring treatment, and recurrence on 1-year follow-up. But that was true only for this carefully selected patient collective.

Conclusion

In a selected patient collective with small and lateral incisional hernias and with a large proportion of women, outcomes obtained for the onlay and sublay techniques do not differ significantly.
Hinweise
Rudolf Schrittwieser and Ferdinand Köckerling contributed equally to this publication.

Publisher's Note

Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Introduction

In systematic reviews, the prevalence of incisional hernia after midline incision was 12.8% (range 0–35.6%) at a weighted mean of 23.7 months [1], and with a lower rate of 4.7% for transverse incisions [2]. Although incisional hernia is a very common clinical manifestation, a substantial heterogeneity in patient selection and clinical practice does exist [3]. In meta-analyses, laparoscopic intraperitoneal onlay mesh (IPOM) was found to have lower wound complication rates compared with the open procedure [47]. However, the guidelines recommend the laparoscopic IPOM technique only for defects up to a maximum of 8–10 cm since, when used for larger defects, the recurrence rate is much higher than in open repair [811]. Meta-analyses of open repair of incisional hernias comparing the sublay with the onlay technique showed advantages in the recurrence and wound complication rates for retrorectal mesh placement [12]. Therefore, in an expert consensus guided by systematic review, the sublay technique was recommended as the optimal mesh location in open incisional hernia surgery [3]. But the panel also stated that onlay mesh location may be useful in certain settings [3]. What is meant by certain settings was not further explained in the expert consensus [3].
Therefore, in the following analysis of data from the Herniamed Registry, the group of patients operated on with the onlay technique was compared with those operated on with the sublay technique to identify differences in the patient- and hernia-related factors. Then, using propensity score matching, comparable patient collectives were formed and the results were compared.

Materials and methods

Herniamed is a multicenter, internet-based hernia registry [13, 14] into which 644 participating hospitals and surgeons engaged in private practice in Germany, Austria, and Switzerland (status: January 5, 2018) have entered data prospectively on their patients who had undergone routine hernia repair and signed an informed consent agreeing to participate [15]. As part of the information provided to patients regarding participation in the Herniamed Registry and signing the informed consent declaration, all patients were informed that the treating hospital or medical practice would like to be informed about any problem occurring after the operation and that the patient had the opportunity to attend for clinical examination [15]. All postoperative complications occurring up to 30 days after surgery were recorded. On 1-year follow-up, postoperative complications were once again reviewed when the general practitioner and patient completed a questionnaire [15]. On 1-year follow-up, the general practitioner and patients were also asked about any recurrences, bulging, pain at rest, pain on exertion, and chronic pain requiring treatment [15]. If recurrences or chronic pain was reported by the general practitioner or patient, patients could be requested to attend clinical examination or radiologic tests [15]. A recent publication has provided impressive evidence of the role of patient-reported outcomes for both recurrence and chronic pain [15, 16].
The present analysis compares the prospective data collected for all patients with primary incisional hernias having undergone elective open repair in sublay or onlay technique. Inclusion criteria were valid minimum age of 16 years, incisional hernia, elective operation, and availability of data on 1-year follow-up (Fig. 1). In all, 7821 patients were enrolled between September 1, 2009, and December 1, 2016, (Fig. 1).
The demographic and patient-related parameters include age (years), gender, American Society of Anesthesiologists (ASA) score I, II, III, IV, BMI kg/m2, and risk factors like chronic obstructive pulmonary disease (COPD), diabetes mellitus, aortic aneurysms, corticoid medication, immunosuppression, coagulopathy, smoking, antiplatelet medication, anticoagulant therapy, and preoperative pain. Hernia-related variables influencing the outcome included the hernia defect size according to the European Hernia Society (EHS) classification (W1 < 4 cm, W2 ≥ 4–10 cm, and W3 > 10 cm) [17] and hernia localization (medial, lateral, and combined) [17]. Hernia width was recorded during surgery based on intraoperative measurements [15]. The dependent variables were intraoperative, postoperative and general complication rates, complication-related reoperation rate, recurrence rate and rates of pain at rest, pain on exertion, and chronic pain requiring treatment [15].
All analyses were performed with the software SAS 9.4 (SAS Institute Inc., Cary, NY, USA) and intentionally calculated to a full significance level of 5%, that is, they were not corrected in respect to multiple tests, and each p value ≤ 0.05 represents a significant result [15].
The individual outcome and influencing variables (risk factors and complications) were summarized as global variables. A general, intra- or postoperative complication or risk factor was deemed to be present if at least one single item applied.
Propensity score matching is a suitable statistical method for formation of comparison groups from a very heterogeneous patient population. Persons with similar characteristics were assigned to the comparison groups and then compared with regard to the outcome variables. The propensity scores were calculated using a logistic regression model with selected matching variables. The following matching variables were selected: age in years, BMI (kg/m2), gender (male/female), risk factors (yes/no), ASA score (I, II, III, and IV), preoperative pain (yes, no, and unknown), defect size (W1 < 4 cm, W2 ≥ 4–10 cm, W3 > 10 cm), and EHS classification (medial, lateral, and combined).
The robust greedy algorithm was used for matching applying a caliper of 0.5 standard deviation.
Unadjusted analyses were performed before matching for analysis of the operation techniques with regard to the matching parameters. This helped to obtain a description of the patient collective before matching. The asymptotic Chi-square test was used for categorical parameters and the robust t test (Satterthwaite) for continuous parameters.
To assess the balance of the single matching parameters between comparison groups after matching, standardized differences are estimated. As a rule of thumb, a good balance between the groups and thus comparability is assured by a standardized difference of less than 10% (< 0.1).
The McNemar’s test was performed to analyze the influence of the operation techniques on the outcome parameters (general, intra- and postoperative complications, complication-related reoperations, pain at rest, pain on exertion, chronic pain requiring treatment, and recurrence at 1-year follow-up) in the matched samples. Furthermore, odds ratio estimates (adjusted for matched samples) and their corresponding 95% confidence intervals are given.

Results

The sublay technique was used in 6797 (86.9%) and the onlay technique in 1024 (13.1%) cases, attesting to the high degree of selection applied to the use of the onlay technique. In the unadjusted analysis of comparison collectives before matching, no significant differences were identified for age (onlay 63.8% ± 13.1% vs. sublay 63.9% ± 12.7%; p = 0.838), BMI (onlay 29.0% ± 5.8% vs. sublay 29.0% ± 5.6%; p = 0.949), preoperative pain (onlay VAS 3.7 ± 1.8 vs. sublay VAS 3.6 ± 1.8; p = 0.069), and ASA score or risk factors (Table 1). However, it was revealed that for the onlay technique highly significantly more hernias with small EHS classifications (W1 < 4 cm: onlay 33.4%, sublay 23.8%) as well as lateral and combined defects (lateral: onlay 27.1%, sublay 16.7%; combined: onlay 10.5%, sublay 7.8%) were repaired. Equally, the proportion of women operated on with the onlay technique was significantly higher. As such, predominantly more small and lateral/combined defects as well as female patients were selected for the onlay technique. Therefore, there is evidence of a selected patient collective since the onlay technique was indicated much more rarely than the sublay technique. Accordingly, the unadjusted results do not lend themselves to comparison.
Table 1
Results of the unadjusted tests of homogeneity between the operation techniques for the categorical matching variables before matching
 
Onlay
Sublay
p
n
%
n
%
Gender
     
 Male
484
47.27
3481
51.21
0.018
 Female
540
52.73
3316
48.79
Defect size (EHS classification)
     
 W1 (<4 cm)
342
33.40
1620
23.83
<.001
 W2 (≥4–10 cm)
517
50.49
3728
54.85
 W3 (≥10 cm)
165
16.11
1449
21.32
ASA score
     
 I
107
10.45
652
9.59
0.545
 II
566
55.27
3865
56.86
 III/IV
351
34.28
2280
33.54
EHS classification
     
 Combined
107
10.45
531
7.81
<.001
 Lateral
277
27.05
1132
16.65
 Medial
640
62.50
5134
75.53
Risk factors
     
 Total
     
  Yes
426
41.60
2987
43.95
0.158
  No
598
58.40
3810
56.05
 COPD
     
  Yes
100
9.77
749
11.02
0.229
  No
924
90.23
6048
88.98
 Diabetes
     
  Yes
151
14.75
925
13.61
0.325
  No
873
85.25
5872
86.39
 Aortic aneurysm
     
  Yes
7
0.68
146
2.15
0.002
  No
1017
99.32
6651
97.85
 Immunosuppression
     
  Yes
17
1.66
149
2.19
0.271
  No
1007
98.34
6648
97.81
 Corticoids
     
  Yes
16
1.56
113
1.66
0.815
  No
1008
98.44
6684
98.34
 Smoking
     
  Yes
106
10.35
899
13.23
0.010
  No
918
89.65
5898
86.77
 Coagulopathy
     
  Yes
28
2.73
160
2.35
0.459
  No
996
97.27
6637
97.65
 ASS/Plavix antiplatelet medication
  Yes
122
11.91
935
13.76
0.108
  No
902
88.09
5862
86.24
 Anticoagulation therapy
     
  Yes
37
3.61
227
3.34
0.651
  No
987
96.39
6570
96.66
Preoperative pain
     
 Yes
560
54.69
3926
57.76
0.176
 No
372
36.33
2312
34.02
 Unknown
92
8.98
559
8.22
Propensity score matching of the 1024 open onlay operations to the 6797 patients with open sublay operation was successfully applied for 1016 (99.2%) patient pairs.
The standardized differences in the matching variables both before (original sample) and after matching (matched samples) are given in Tables 2 and 3. The difference is less than 10% for all matching variables, attesting to the good balance of the variables between the groups.
Table 2
Standardized differences of continuous matching parameters before and after matching
 
Onlay
Sublay
STD
Matched sample
Original sample
Age (years)
    
 Mean ± STD
63.9 ± 13.1
63.5 ± 12.6
0.032
0.007
BMI
    
 Mean ± STD
29.0 ± 5.8
28.8 ± 5.8
0.026
0.002
Table 3
Standardized differences of the categorical matching parameters before and after matching
 
Onlay
Sublay
STD
n
%
n
%
Matched sample
Original sample
Male
482
47.44
514
50.59
0.063
0.079
Preoperative pain
554
54.53
556
54.72
0.004
0.062
No preoperative pain
370
36.42
382
37.60
0.024
0.048
Unknown preoperative pain
92
9.06
78
7.68
0.050
0.027
ASA score I
106
10.43
108
10.63
0.006
0.029
ASA score II
563
55.41
581
57.19
0.036
0.032
ASA score III–IV
347
34.15
327
32.19
0.042
0.015
W1 (< 4 cm)
338
33.27
344
33.86
0.013
0.213
W2 (≥  4–10 cm)
513
50.49
511
50.30
0.004
0.087
W3 (≥ 10 cm)
165
16.24
161
15.85
0.011
0.134
EHS classification medial
741
72.93
736
72.44
0.011
0.254
EHS classification lateral
382
37.60
387
38.09
0.010
0.285
Risk factors
423
41.63
401
39.47
0.044
0.047
The results of analysis of the various outcome parameters for the sublay and onlay operation techniques are shown in Table 4. No systematic deviation was identified in the outcome parameters between the two operation techniques. All confidence intervals cross one. Hence, no advantage or disadvantage can be identified for any outcome variable of the two operation techniques. Therefore, for a selected patient collective with predominantly small and lateral or combined defects, and more female patients, similar results were obtained for the sublay and onlay techniques.
Table 4
Proportion of cases in which the respective operation technique would have had disadvantages (n = 1.016 matched pairs)
 
Disadvantages
p value
OR estimate for matched samples
Onlay
Sublay
OR
  
Intraoperative complications
1.67
1.28
0.585
1.308
0.598
2.928
General complications
2.46
2.95
0.590
0.833
0.470
1.466
Postoperative complications
8.56
7.78
0.587
1.101
0.803
1.513
Complication-related reoperation
3.74
4.13
0.738
0.905
0.568
1.438
Recurrence on 1-year follow-up
5.31
4.13
0.261
1.286
0.843
1.972
Pain on exertion on 1-year follow-up
15.94
15.35
0.779
1.038
0.828
1.302
Pain at rest on 1-year follow-up
10.53
10.53
1.000
1.000
0.758
1.320
Chronic pain requiring treatment on 1-year follow-up
7.48
7.28
0.935
1.027
0.736
1.434
The fact that for women the onlay technique was used more often led us to perform an additional analysis. That showed that neither for the onlay nor the sublay technique was there any significant differences between men and women with regard to the hernia defect width or defect localization. But there were significant differences between men and women where the risk factors were concerned. For example, for women operated on in the sublay technique, the risk factor rate was 40.7% versus 47.1% for men (p < 0.001) and, likewise, for the onlay technique that was 38.0% versus 45.7% (p = 0.013). Hence, the lower rate of risk factors in women appears to have resulted in the onlay technique being indicated more often for them.
A further additional analysis looked for any differences between the technical details of the two techniques. That showed that defect closure at 57.8% was significantly more common in the onlay technique than in the sublay technique with 46.2% (p < 0.001). Drains were used more often for sublay repair (84.0% versus 80.1%; p = 0.012). Mesh fixation was done significantly more often in the onlay technique with suture alone (94.0% vs. 89.5%; p < 0.001) or tackers (3.0% vs. 0.6%; p < 0.001) and significantly less often with glue (0.9% vs. 4.6%; p < 0.001) or a combination thereof (2.1% vs. 5.3%; p < 0.001). Numerous meshes were used in a proportion of < 5% of cases, at 58.7% in the onlay technique and 55.2% in the sublay technique. Only for the Ultrapro (onlay 29.2%, sublay 31.0%), Parietene ProGrip (onlay 8.7%, sublay 7.2%), and the Parietex ProGrip (onlay 3.4%, sublay 6.7%) was the proportion higher.

Discussion

This analysis of data from the Herniamed Registry first of all demonstrates that the onlay technique is used only rarely, and thus selectively, compared to the sublay technique for repair of incisional hernia. When it is used, the proportion of lateral or combined defects, smaller hernias, and the proportion of women are significantly higher than in the sublay collective. Women in both the onlay and sublay groups were found to have a lower rate of risk factors. There were no differences between women and men with regard to defect sizes or defect localizations.
After propensity score matching of this selected onlay collective with the sublay collective, no significant difference is then observed between the use of the sublay and onlay techniques for repair of incisional hernias with regard to any of the outcome criteria, i.e., intra-, postoperative and general complications, complication-related reoperation, pain at rest, pain on exertion, chronic pain requiring treatment, and recurrence on 1-year follow-up.
This thus suggests that surgeons have properly evaluated the indication for the onlay operation. In studies with a comparatively low selection-based proportion of onlay operations for repair of incisional hernias, there was likewise a lower postoperative complication and recurrence rate [1821]. Surgical experience, selective indications, and smaller defects seem to reduce the postoperative complication and recurrence rates for the onlay technique in incisional hernia repair [1821]. Furthermore, the postoperative wound complication rate can be reduced through preventive technical measures such as defect closure, drains, refixation of the subcutaneous tissue to the abdominal wall with low-thrombin fibrin sealant, and abdominal binders [21]. In the present patient collective defect, closure was significantly more common in the onlay technique than in the sublay technique. Drains were used in around 80% of cases for both techniques.
Therefore, future studies on the onlay technique in incisional hernia repair should involve selected indications, a standardized surgical technique by experienced surgeons, and incorporation of preventive measures against seroma formation [21] since in a qualitative systematic review of all published studies on the onlay technique the mean postoperative complication rate was 33.5% (range 5–76%). That high postoperative complication rate contraindicates the routine use of the onlay technique [21]. The onlay technique should not be used routinely, in particular, for large midline incisional hernias [22] because the postoperative complication rate is much too high compared with the sublay operation [21].
Registry studies have certain limitations. Voluntary data submission is dependent on the motivation of the participating surgeons to achieve complete data capture [23]. It is not always possible to definitely rule out a reporting bias with underreporting [23]. Therefore, all findings are subjected to critical scrutiny on the basis of the literature data.
In summary, it has been noted that subject to appropriate selection of smaller and lateral defects in predominant women with a lower risk profile, the onlay technique can be used while assuring similar outcomes to the sublay operation. Of paramount importance here are the surgeon’s experience and the use of preventive measures (defect closure, drain, abdominal binder, and fibrin glue) for avoidance of postoperative complications. For larger defects, especially at the midline, better results can be obtained with other operation techniques (sublay and transversus abdominis release) [24, 25]. The registry data demonstrate that the onlay technique can be safely performed in selected cases.

Acknowledgements

Funding was provided by Bard, Karlsruhe, Germany (Grant to fund the Herniamed Registry), Johnson and Johnson, Norderstedt, Germany (Grant to fund the Herniamed Registry), Dahlhausen, Cologne, Germany (Grant to fund the Herniamed Registry), MenkeMed, Munich, Germany (Grant to fund the Herniamed Registry), pfm medical, Cologne, Germany (Grant to fund the Herniamed Registry), B Braun, Tuttlingen, Germany (Grant to fund the Herniamed Registry), and Karl Storz, Tuttlingen, Germany (Grant to fund the Herniamed Registry)
Open AccessThis article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://​creativecommons.​org/​licenses/​by/​4.​0/​), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made.

Publisher's Note

Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Unsere Produktempfehlungen

Die Chirurgie

Print-Titel

Das Abo mit mehr Tiefe

Mit der Zeitschrift Die Chirurgie erhalten Sie zusätzlich Online-Zugriff auf weitere 43 chirurgische Fachzeitschriften, CME-Fortbildungen, Webinare, Vorbereitungskursen zur Facharztprüfung und die digitale Enzyklopädie e.Medpedia.

Bis 30. April 2024 bestellen und im ersten Jahr nur 199 € zahlen!

e.Med Interdisziplinär

Kombi-Abonnement

Für Ihren Erfolg in Klinik und Praxis - Die beste Hilfe in Ihrem Arbeitsalltag

Mit e.Med Interdisziplinär erhalten Sie Zugang zu allen CME-Fortbildungen und Fachzeitschriften auf SpringerMedizin.de.

Literatur
Metadaten
Titel
Small and Laterally Placed Incisional Hernias Can be Safely Managed with an Onlay Repair
verfasst von
Rudolf Schrittwieser
Ferdinand Köckerling
Daniela Adolf
Martin Hukauf
Simone Gruber-Blum
René H. Fortelny
Alexander H. Petter-Puchner
Publikationsdatum
11.03.2019
Verlag
Springer International Publishing
Erschienen in
World Journal of Surgery / Ausgabe 8/2019
Print ISSN: 0364-2313
Elektronische ISSN: 1432-2323
DOI
https://doi.org/10.1007/s00268-019-04980-6

Weitere Artikel der Ausgabe 8/2019

World Journal of Surgery 8/2019 Zur Ausgabe

Update Chirurgie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.

S3-Leitlinie „Diagnostik und Therapie des Karpaltunnelsyndroms“

CME: 2 Punkte

Prof. Dr. med. Gregor Antoniadis Das Karpaltunnelsyndrom ist die häufigste Kompressionsneuropathie peripherer Nerven. Obwohl die Anamnese mit dem nächtlichen Einschlafen der Hand (Brachialgia parästhetica nocturna) sehr typisch ist, ist eine klinisch-neurologische Untersuchung und Elektroneurografie in manchen Fällen auch eine Neurosonografie erforderlich. Im Anfangsstadium sind konservative Maßnahmen (Handgelenksschiene, Ergotherapie) empfehlenswert. Bei nicht Ansprechen der konservativen Therapie oder Auftreten von neurologischen Ausfällen ist eine Dekompression des N. medianus am Karpaltunnel indiziert.

Prof. Dr. med. Gregor Antoniadis
Berufsverband der Deutschen Chirurgie e.V.

S2e-Leitlinie „Distale Radiusfraktur“

CME: 2 Punkte

Dr. med. Benjamin Meyknecht, PD Dr. med. Oliver Pieske Das Webinar S2e-Leitlinie „Distale Radiusfraktur“ beschäftigt sich mit Fragen und Antworten zu Diagnostik und Klassifikation sowie Möglichkeiten des Ausschlusses von Zusatzverletzungen. Die Referenten erläutern, welche Frakturen konservativ behandelt werden können und wie. Das Webinar beantwortet die Frage nach aktuellen operativen Therapiekonzepten: Welcher Zugang, welches Osteosynthesematerial? Auf was muss bei der Nachbehandlung der distalen Radiusfraktur geachtet werden?

PD Dr. med. Oliver Pieske
Dr. med. Benjamin Meyknecht
Berufsverband der Deutschen Chirurgie e.V.

S1-Leitlinie „Empfehlungen zur Therapie der akuten Appendizitis bei Erwachsenen“

CME: 2 Punkte

Dr. med. Mihailo Andric
Inhalte des Webinars zur S1-Leitlinie „Empfehlungen zur Therapie der akuten Appendizitis bei Erwachsenen“ sind die Darstellung des Projektes und des Erstellungswegs zur S1-Leitlinie, die Erläuterung der klinischen Relevanz der Klassifikation EAES 2015, die wissenschaftliche Begründung der wichtigsten Empfehlungen und die Darstellung stadiengerechter Therapieoptionen.

Dr. med. Mihailo Andric
Berufsverband der Deutschen Chirurgie e.V.