Skip to main content
Erschienen in: CardioVascular and Interventional Radiology 4/2006

01.08.2006

“Recovery™” Vena Cava Filter: Experience in 96 Patients

Erschienen in: CardioVascular and Interventional Radiology | Ausgabe 4/2006

Einloggen, um Zugang zu erhalten

Abstract

The purpose of the study was to assess the clinical safety and efficacy of the “RecoveryTM” (Bard) inferior vena cava (IVC) filter. We retrospectively evaluated the clinical and imaging data of patients who had a “RecoveryTM” IVC filter placed between January 2003 and December 2004 in our institution. The clinical presentation, indications, and procedure-related complications during placement and retrieval were evaluated. Follow-up computed tomography (CT) examinations of the abdomen and chest were evaluated for filter-related complications and pulmonary embolism (PE), respectively. “Recovery” filters were placed in 96 patients (72 males and 24 females; age range: 16–87 years; mean: 46 years). Twenty-four patients presented with PE, 13 with deep vein thrombosis (DVT) and 2 with both PE and DVT. The remaining 57 patients had no symptoms of thromboembolism. Indications for filter placement included contraindication to anticoagulation (n = 27), complication of anticoagulation (n = 3), failure of anticoagulation (n = 5), and prophylaxis (n = 61). The device was successfully deployed in the infrarenal (n = 95) or suprarenal (n = 1) IVC through a femoral vein approach. Retrieval was attempted in 11 patients after a mean period of 117 days (range: 24–426). The filter was successfully removed in nine patients (82%). Failure of retrieval was due to technical difficulty (n = 1) and the presence of thrombus in the filter (n = 1). One of the nine patients who had the filter removed developed IVC thrombus after retrieval and another had an intimal tear of the IVC. Follow-up abdominal CT (n = 40) at a mean of 80 days (range: 1–513) showed penetration of the IVC by the filter arms in 11, of which 3 had fracture of filter components. In one patient, a broken arm migrated into the pancreas. Asymmetric deployment of the filter legs was seen in 12 patients and thrombus within the filter in 2 patients. No filter migration or caval occlusion was encountered. Follow-up chest CT (n = 27) at a mean of 63 days (range: 1–386) showed PE in one patient (3%). During clinical follow-up, 12 of 96 patients developed symptoms of PE and only 1 of the 12 had PE on CT. There was no fatal pulmonary embolism in our group of patients following “Recovery” filter placement. However, the current version of the filter is associated with structure weakness, a high incidence of IVC wall penetration, and asymmetric deployment of the filter legs.
Literatur
1.
Zurück zum Zitat Bick RL (1999) Hereditary and acquired thrombophilia: preface. Semin Thromb Hemost 25:251–253PubMed Bick RL (1999) Hereditary and acquired thrombophilia: preface. Semin Thromb Hemost 25:251–253PubMed
2.
Zurück zum Zitat Levine M, Raskob GE, Landefeld Cs, et al. (1998) Hemorrhagic complications of anticoagulant treatment. Chest 114(Suppl):511S–523SPubMed Levine M, Raskob GE, Landefeld Cs, et al. (1998) Hemorrhagic complications of anticoagulant treatment. Chest 114(Suppl):511S–523SPubMed
3.
Zurück zum Zitat Mobin-Uddin K, McLean R, Bolooki H, et al. (1969) Caval interruption for prevention of pulmonary embolism: Long-term results of a new method. Arch Surg 99:711–715PubMed Mobin-Uddin K, McLean R, Bolooki H, et al. (1969) Caval interruption for prevention of pulmonary embolism: Long-term results of a new method. Arch Surg 99:711–715PubMed
4.
Zurück zum Zitat Greenfield LJ, McCurdy JR, Brown PP, et al. (1973) A new vena caval filter permitting continued flow and resolution of emboli. Surgery 73:599–606PubMed Greenfield LJ, McCurdy JR, Brown PP, et al. (1973) A new vena caval filter permitting continued flow and resolution of emboli. Surgery 73:599–606PubMed
5.
Zurück zum Zitat Athanasoulis C (2000) Inferior vena caval filters: Review of a 26-year single-center clinical experience. Radiology 216:54–66PubMed Athanasoulis C (2000) Inferior vena caval filters: Review of a 26-year single-center clinical experience. Radiology 216:54–66PubMed
6.
Zurück zum Zitat Wilson JT, Rogers FB, Wald SL, et al. (1994) Prophylactic vena cava filter insertion in patients with traumatic spinal cord injury: preliminary results. Neurosurgery 35:234–239PubMed Wilson JT, Rogers FB, Wald SL, et al. (1994) Prophylactic vena cava filter insertion in patients with traumatic spinal cord injury: preliminary results. Neurosurgery 35:234–239PubMed
7.
Zurück zum Zitat Rosner MK, Kuklo TR, Tawk R, et al. (2004) Prophylactic placement of an inferior vena cava filter in high-risk patients undergoing spinal reconstruction. Neurosurg Focus 17:E6PubMedCrossRef Rosner MK, Kuklo TR, Tawk R, et al. (2004) Prophylactic placement of an inferior vena cava filter in high-risk patients undergoing spinal reconstruction. Neurosurg Focus 17:E6PubMedCrossRef
8.
Zurück zum Zitat Ray CE, Kaufman JA (1996) Complications of inferior vena cava filters. Abdom Imaging 21:368–374PubMedCrossRef Ray CE, Kaufman JA (1996) Complications of inferior vena cava filters. Abdom Imaging 21:368–374PubMedCrossRef
9.
Zurück zum Zitat Ballew KA, Philbrick JT, Becker DM (1995) Vena cava filter devices. Clin Chest Med 16:295–305PubMed Ballew KA, Philbrick JT, Becker DM (1995) Vena cava filter devices. Clin Chest Med 16:295–305PubMed
10.
Zurück zum Zitat Kaufman JA, Geller SC (1994) Questions and answers. Am J Roentgenol 164:256–257 Kaufman JA, Geller SC (1994) Questions and answers. Am J Roentgenol 164:256–257
11.
Zurück zum Zitat Lorch H, Welger D, Wagner, et al. (2000) Current practice of temporary vena cava filter insertion: A multicenter registry. J Vasc Intervent Radiol 11:83–88 Lorch H, Welger D, Wagner, et al. (2000) Current practice of temporary vena cava filter insertion: A multicenter registry. J Vasc Intervent Radiol 11:83–88
12.
Zurück zum Zitat Kinney TB (2003) Update on inferior vena cava filters. J Vasc Intervent Radiol 14:425–440 Kinney TB (2003) Update on inferior vena cava filters. J Vasc Intervent Radiol 14:425–440
13.
Zurück zum Zitat Asch MR (2002) Initial experience in humans with a new retrievable inferior vena cava filter. Radiology 225:835–844PubMed Asch MR (2002) Initial experience in humans with a new retrievable inferior vena cava filter. Radiology 225:835–844PubMed
14.
Zurück zum Zitat Wicky S, Doenz F, Muewly JY, et al. (2003) Clinical experience with retrievable Gunther tulip vena cava filters. J Endovasc Ther 10:994–1000PubMedCrossRef Wicky S, Doenz F, Muewly JY, et al. (2003) Clinical experience with retrievable Gunther tulip vena cava filters. J Endovasc Ther 10:994–1000PubMedCrossRef
15.
Zurück zum Zitat Millward SF, Oliva VL, Bell SD, et al. (2001) Gunther Tulip retrievable vena cava filter: Results from the registry of the Canadian interventional radiology association. J Vasc Intervent Radiol 12:1053–1058 Millward SF, Oliva VL, Bell SD, et al. (2001) Gunther Tulip retrievable vena cava filter: Results from the registry of the Canadian interventional radiology association. J Vasc Intervent Radiol 12:1053–1058
16.
Zurück zum Zitat Yune HY (1989) Inferior vena cava filter: Search for an ideal device. Radiology 172:15–16PubMed Yune HY (1989) Inferior vena cava filter: Search for an ideal device. Radiology 172:15–16PubMed
17.
Zurück zum Zitat Millward SF (1998) Temorary and retrievable inferior vena cava filters: Current status. J Vasc Intervent Radiol 9:381–387CrossRef Millward SF (1998) Temorary and retrievable inferior vena cava filters: Current status. J Vasc Intervent Radiol 9:381–387CrossRef
18.
Zurück zum Zitat Kaufman JA (2004) Retrievable vena cava filers. Tech Vasc Intervent Radiol 7:96–104CrossRef Kaufman JA (2004) Retrievable vena cava filers. Tech Vasc Intervent Radiol 7:96–104CrossRef
19.
Zurück zum Zitat Greenfield LJ, Rutherford RB, Participants of the Vena Cava Filter Consensus Conference (1999) Recommended reporting standards for vena cava filter placement and patient follow-up. J Vasc Surg 30:573–579CrossRef Greenfield LJ, Rutherford RB, Participants of the Vena Cava Filter Consensus Conference (1999) Recommended reporting standards for vena cava filter placement and patient follow-up. J Vasc Surg 30:573–579CrossRef
20.
Zurück zum Zitat Decousus H, Leizorovicz A, Parent F, et al. (1998) A clinical trial of vena caval filters in the preventiona of pulmonary embolism in patients with proximal deep-vein thrombosis. N Engl J Med 338:409–415PubMedCrossRef Decousus H, Leizorovicz A, Parent F, et al. (1998) A clinical trial of vena caval filters in the preventiona of pulmonary embolism in patients with proximal deep-vein thrombosis. N Engl J Med 338:409–415PubMedCrossRef
21.
Zurück zum Zitat Brountzos E, Kaufman J, Venbrux A, et al. (2003) A new optional vena cava filter: retrieval at 12 weeks in an animal model. J Vasc Intervent Radiol 14:763–772 Brountzos E, Kaufman J, Venbrux A, et al. (2003) A new optional vena cava filter: retrieval at 12 weeks in an animal model. J Vasc Intervent Radiol 14:763–772
22.
Zurück zum Zitat Kinney TB, Rose SC, Weingarten KW, et al. (1997) IVC filter tilt and asymmetry: Comparison of the over-the-wire stainless-steel and titanium Greenfield IVC filters. J Vasc Intervent Radiol 8:1080–1082 Kinney TB, Rose SC, Weingarten KW, et al. (1997) IVC filter tilt and asymmetry: Comparison of the over-the-wire stainless-steel and titanium Greenfield IVC filters. J Vasc Intervent Radiol 8:1080–1082
23.
Zurück zum Zitat Greenfield LJ, Proctor MC, Cho KJ, et al. (1997) Limb asymmetry in titanium Greenfield filters: clinically significant? J Vasc Surg 26:770–775PubMedCrossRef Greenfield LJ, Proctor MC, Cho KJ, et al. (1997) Limb asymmetry in titanium Greenfield filters: clinically significant? J Vasc Surg 26:770–775PubMedCrossRef
24.
Zurück zum Zitat Putterman D, Niman D, Cohen G (2005) Aortic pseudoaneurysm after penetration by a Simon nitinol inferior vena cava filter. J Vasc Intervent Radiol 16:535–538 Putterman D, Niman D, Cohen G (2005) Aortic pseudoaneurysm after penetration by a Simon nitinol inferior vena cava filter. J Vasc Intervent Radiol 16:535–538
25.
Zurück zum Zitat Morris CS, Rogers FB, Najarian KE, et al. (2004) Current trends in vena caval filtration with the introduction of a retrievable filter at a level I trauma center. J Trauma 57:32–36PubMedCrossRef Morris CS, Rogers FB, Najarian KE, et al. (2004) Current trends in vena caval filtration with the introduction of a retrievable filter at a level I trauma center. J Trauma 57:32–36PubMedCrossRef
26.
Zurück zum Zitat Terhaar OA, Lyon SM, Given MF, et al. (2004) Extended interval for retrieval of Gunther Tulip filters. J Vasc Intervent Radiol 15:1257–1262 Terhaar OA, Lyon SM, Given MF, et al. (2004) Extended interval for retrieval of Gunther Tulip filters. J Vasc Intervent Radiol 15:1257–1262
27.
Zurück zum Zitat Stannard JP, Singhania AK, Lopez-Ben RR, et al. (2005) Deep-vein thrombosis in high-energy skeletal trauma despite thromboprophylaxis. Bone Joint Surg Br 87:965–968CrossRef Stannard JP, Singhania AK, Lopez-Ben RR, et al. (2005) Deep-vein thrombosis in high-energy skeletal trauma despite thromboprophylaxis. Bone Joint Surg Br 87:965–968CrossRef
28.
Zurück zum Zitat Borer DS, Starr AJ, Reinert CM, et al. (2005) The effect of screening for deep vein thrombosis on the prevalence of pulmonary embolism in patients with fractures of the pelvis or acetabulum: A review of 973 patients. J Orthop Trauma 19:92–95PubMedCrossRef Borer DS, Starr AJ, Reinert CM, et al. (2005) The effect of screening for deep vein thrombosis on the prevalence of pulmonary embolism in patients with fractures of the pelvis or acetabulum: A review of 973 patients. J Orthop Trauma 19:92–95PubMedCrossRef
Metadaten
Titel
“Recovery™” Vena Cava Filter: Experience in 96 Patients
Publikationsdatum
01.08.2006
Erschienen in
CardioVascular and Interventional Radiology / Ausgabe 4/2006
Print ISSN: 0174-1551
Elektronische ISSN: 1432-086X
DOI
https://doi.org/10.1007/s00270-005-0271-1

Weitere Artikel der Ausgabe 4/2006

CardioVascular and Interventional Radiology 4/2006 Zur Ausgabe

Update Radiologie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.