Purpose

This study was designed to assess the enhanced effect of high intensity focused ultrasound (HIFU) ablation with microbubbles on rabbit hepatic VX2 tumors and to compare the detection sensitivity of CEUS and CECT to determine the residual viable tissue after ablation of HIFU.

Methods

Forty rabbits with hepatic VX2 tumors were randomly separated into two groups (20 animals per group) before HIFU ablation. A bolus of 0.2 mL of saline or a microbubble-based ultrasound (US) contrast agent was injected intravenously to group I rabbits and group II rabbits, respectively. The HIFU ablation procedure was started 15 s after the injection. Tumors were examined with grayscale contrast-enhanced ultrasound (CEUS) and contrast-enhanced computed tomography (CECT) immediately before and after HIFU ablation. Histopathologic assessment was performed immediately after treatment imaging.

Results

Before ablation, intense contrast enhancement during arterial phase was observed at the whole tumors or the periphery of the tumors by CEUS and CECT. Lower HIFU energy was used in group II than in group I (P < 0.001). Histopathologic assessment revealed local residual viable tumor tissues due to incomplete ablation in 47.4% (9/19) of tumors in group I and 10% (2/20) of tumors in group II (P < 0.05). The concordance rate of CEUS (90.9%) with histopathology on residual tumor detection was higher than that of CECT (27.3%, P < 0.05).

Conclusions

Introduction of the microbubble agent enhances HIFU therapeutic efficacy. CEUS proves to have high sensitivity in assessment of residual viable rabbit VX2 tumor after HIFU.
Literatur
1.
Zurück zum Zitat Hwang JH, Crum LA (2009) Current status of clinical high-intensity focused ultrasound. Conf Proc IEEE Eng Med Biol Soc 2009:130–133PubMed Hwang JH, Crum LA (2009) Current status of clinical high-intensity focused ultrasound. Conf Proc IEEE Eng Med Biol Soc 2009:130–133PubMed
2.
Zurück zum Zitat Li Q, Du J, Yu M et al (2009) Transmission electron microscopy of VX2 liver tumors after high-intensity focused ultrasound ablation enhanced with SonoVue. Adv Ther 26(1):117–125PubMedCrossRef Li Q, Du J, Yu M et al (2009) Transmission electron microscopy of VX2 liver tumors after high-intensity focused ultrasound ablation enhanced with SonoVue. Adv Ther 26(1):117–125PubMedCrossRef
3.
Zurück zum Zitat Li JJ, Gu MF, Luo GY et al (2009) Complications of high intensity focused ultrasound for patients with hepatocellular carcinoma. Technol Cancer Res Treat 8(3):217–224PubMed Li JJ, Gu MF, Luo GY et al (2009) Complications of high intensity focused ultrasound for patients with hepatocellular carcinoma. Technol Cancer Res Treat 8(3):217–224PubMed
4.
Zurück zum Zitat Thuroff S, Chaussy C (2000) High-intensity focused ultrasound: complications and adverse events. Mol Urol 4(3):183–187PubMed Thuroff S, Chaussy C (2000) High-intensity focused ultrasound: complications and adverse events. Mol Urol 4(3):183–187PubMed
5.
Zurück zum Zitat Wu F, Wang ZB, Chen WZ et al (2004) Extracorporeal high intensity focused ultrasound ablation in the treatment of patients with large hepatocellular carcinoma. Ann Surg Oncol 11(12):1061–1069PubMedCrossRef Wu F, Wang ZB, Chen WZ et al (2004) Extracorporeal high intensity focused ultrasound ablation in the treatment of patients with large hepatocellular carcinoma. Ann Surg Oncol 11(12):1061–1069PubMedCrossRef
6.
Zurück zum Zitat Luo W, Zhou X, Yu M et al (2009) Ablation of high-intensity focused ultrasound assisted with SonoVue on Rabbit VX2 liver tumors: sequential findings with histopathology, immunohistochemistry, and enzyme histochemistry. Ann Surg Oncol 16(8):2359–2368PubMedCrossRef Luo W, Zhou X, Yu M et al (2009) Ablation of high-intensity focused ultrasound assisted with SonoVue on Rabbit VX2 liver tumors: sequential findings with histopathology, immunohistochemistry, and enzyme histochemistry. Ann Surg Oncol 16(8):2359–2368PubMedCrossRef
7.
Zurück zum Zitat Yu T, Xiong S, Mason TJ et al (2006) The use of a micro-bubble agent to enhance rabbit liver destruction using high intensity focused ultrasound. Ultrason Sonochem 13(2):143–149PubMedCrossRef Yu T, Xiong S, Mason TJ et al (2006) The use of a micro-bubble agent to enhance rabbit liver destruction using high intensity focused ultrasound. Ultrason Sonochem 13(2):143–149PubMedCrossRef
8.
Zurück zum Zitat Luo W, Zhou X, Ren X et al (2007) Enhancing effects of SonoVue, a microbubble sonographic contrast agent, on high-intensity focused ultrasound ablation in rabbit livers in vivo. J Ultrasound Med 26(4):469–476PubMed Luo W, Zhou X, Ren X et al (2007) Enhancing effects of SonoVue, a microbubble sonographic contrast agent, on high-intensity focused ultrasound ablation in rabbit livers in vivo. J Ultrasound Med 26(4):469–476PubMed
9.
Zurück zum Zitat Jiang Y, Tian X, Luo W et al (2007) Transmission electron microscopy of rabbit liver after high-intensity focused ultrasound ablation combined with ultrasound contrast agents. Adv Ther 24(4):700–705PubMedCrossRef Jiang Y, Tian X, Luo W et al (2007) Transmission electron microscopy of rabbit liver after high-intensity focused ultrasound ablation combined with ultrasound contrast agents. Adv Ther 24(4):700–705PubMedCrossRef
10.
Zurück zum Zitat Wu F, Chen WZ, Bai J et al (2002) Tumor vessel destruction resulting from high-intensity focused ultrasound in patients with solid malignancies. Ultrasound Med Biol 28(4):535–542PubMedCrossRef Wu F, Chen WZ, Bai J et al (2002) Tumor vessel destruction resulting from high-intensity focused ultrasound in patients with solid malignancies. Ultrasound Med Biol 28(4):535–542PubMedCrossRef
11.
Zurück zum Zitat Goldberg SN, Gazelle GS, Compton CC (2000) Treatment of intrahepatic malignancy with radiofrequency ablation: radiologic-pathologic correlation. Cancer 88(11):2452–2463PubMedCrossRef Goldberg SN, Gazelle GS, Compton CC (2000) Treatment of intrahepatic malignancy with radiofrequency ablation: radiologic-pathologic correlation. Cancer 88(11):2452–2463PubMedCrossRef
12.
Zurück zum Zitat Goldberg SN, Gazelle GS, Mueller PR (2000) Thermal ablation therapy for focal malignancy: a unified approach to underlying principles, techniques, and diagnostic imaging guidance. AJR Am J Roentgenol 174(2):323–331PubMed Goldberg SN, Gazelle GS, Mueller PR (2000) Thermal ablation therapy for focal malignancy: a unified approach to underlying principles, techniques, and diagnostic imaging guidance. AJR Am J Roentgenol 174(2):323–331PubMed
13.
Zurück zum Zitat Illing RO, Kennedy JE, Wu F et al (2005) The safety and feasibility of extracorporeal high-intensity focused ultrasound (HIFU) for the treatment of liver and kidney tumours in a western population. Br J Cancer 93(8):890–895PubMedCrossRef Illing RO, Kennedy JE, Wu F et al (2005) The safety and feasibility of extracorporeal high-intensity focused ultrasound (HIFU) for the treatment of liver and kidney tumours in a western population. Br J Cancer 93(8):890–895PubMedCrossRef
14.
Zurück zum Zitat Schwarz KQ, Chen X, Steinmetz S (1997) Harmonic imaging with Levovist. J Am Soc Echocardiogr 10(1):1–10PubMedCrossRef Schwarz KQ, Chen X, Steinmetz S (1997) Harmonic imaging with Levovist. J Am Soc Echocardiogr 10(1):1–10PubMedCrossRef
15.
Zurück zum Zitat Xu HX, Lu MD, Xie XH et al (2009) Treatment response evaluation with three-dimensional contrast-enhanced ultrasound for liver cancer after local therapies. Eur J Radiol doi:10.1016/j.ejrad.2009.05.006 [Epub ahead of print] Xu HX, Lu MD, Xie XH et al (2009) Treatment response evaluation with three-dimensional contrast-enhanced ultrasound for liver cancer after local therapies. Eur J Radiol doi:10.​1016/​j.​ejrad.​2009.​05.​006 [Epub ahead of print]
16.
Zurück zum Zitat Hwang JH, Wang YN, Warren C et al (2009) Preclinical in vivo evaluation of an extracorporeal HIFU device for ablation of pancreatic tumors. Ultrasound Med Biol 35(6):967–975PubMedCrossRef Hwang JH, Wang YN, Warren C et al (2009) Preclinical in vivo evaluation of an extracorporeal HIFU device for ablation of pancreatic tumors. Ultrasound Med Biol 35(6):967–975PubMedCrossRef
17.
Zurück zum Zitat Yu T, Wang G, Hu K et al (2004) A microbubble agent improves the therapeutic efficiency of high intensity focused ultrasound: a rabbit kidney study. Urol Res 32(1):14–19PubMedCrossRef Yu T, Wang G, Hu K et al (2004) A microbubble agent improves the therapeutic efficiency of high intensity focused ultrasound: a rabbit kidney study. Urol Res 32(1):14–19PubMedCrossRef
18.
Zurück zum Zitat Hansler J, Neureiter D, Wasserburger M et al (2004) Percutaneous US-guided radiofrequency ablation with perfused needle applicators: improved survival with the VX2 tumor model in rabbits. Radiology 230(1):169–174PubMedCrossRef Hansler J, Neureiter D, Wasserburger M et al (2004) Percutaneous US-guided radiofrequency ablation with perfused needle applicators: improved survival with the VX2 tumor model in rabbits. Radiology 230(1):169–174PubMedCrossRef
19.
Zurück zum Zitat Bonte FJ, Curry GC, Parkey RW (1969) Experimental studies of the splanchnic circulation of the rabbit after ligation of the superior mesenteric artery. I. Angiographic and physiologic studies. Am J Roentgenol Radium Ther Nucl Med 106(4):691–699PubMed Bonte FJ, Curry GC, Parkey RW (1969) Experimental studies of the splanchnic circulation of the rabbit after ligation of the superior mesenteric artery. I. Angiographic and physiologic studies. Am J Roentgenol Radium Ther Nucl Med 106(4):691–699PubMed
20.
Zurück zum Zitat Wu H, Exner AA, Shi H et al (2009) Dynamic evolutionary changes in blood flow measured by CECT in a hepatic VX2 tumor implant over an extended 28-day growth period: time-density curve analysis. Acad Radiol 16(12):1483–1492PubMedCrossRef Wu H, Exner AA, Shi H et al (2009) Dynamic evolutionary changes in blood flow measured by CECT in a hepatic VX2 tumor implant over an extended 28-day growth period: time-density curve analysis. Acad Radiol 16(12):1483–1492PubMedCrossRef
21.
Zurück zum Zitat Kuszyk BS, Boitnott JK, Choti MA et al (2000) Local tumor recurrence following hepatic cryoablation: radiologic-histopathologic correlation in a rabbit model. Radiology 217(2):477–486PubMed Kuszyk BS, Boitnott JK, Choti MA et al (2000) Local tumor recurrence following hepatic cryoablation: radiologic-histopathologic correlation in a rabbit model. Radiology 217(2):477–486PubMed
22.
Zurück zum Zitat Chen L, ter Haar G, Hill CR et al (1993) Effect of blood perfusion on the ablation of liver parenchyma with high-intensity focused ultrasound. Phys Med Biol 38(11):1661–1673PubMedCrossRef Chen L, ter Haar G, Hill CR et al (1993) Effect of blood perfusion on the ablation of liver parenchyma with high-intensity focused ultrasound. Phys Med Biol 38(11):1661–1673PubMedCrossRef
23.
Zurück zum Zitat Hariharan P, Myers MR, Banerjee RK (2007) HIFU procedures at moderate intensities—effect of large blood vessels. Phys Med Biol 52(12):3493–3513PubMedCrossRef Hariharan P, Myers MR, Banerjee RK (2007) HIFU procedures at moderate intensities—effect of large blood vessels. Phys Med Biol 52(12):3493–3513PubMedCrossRef
24.
Zurück zum Zitat Fry FJ (1993) Intense focused ultrasound in medicine. Some practical guiding physical principles from sound source to focal site in tissue. Eur Urol 23(Suppl 1):2–7PubMed Fry FJ (1993) Intense focused ultrasound in medicine. Some practical guiding physical principles from sound source to focal site in tissue. Eur Urol 23(Suppl 1):2–7PubMed
25.
Zurück zum Zitat Giorgio A, Ferraioli G, Tarantino L et al (2004) Contrast-enhanced sonographic appearance of hepatocellular carcinoma in patients with cirrhosis: comparison with contrast-enhanced helical CT appearance. AJR Am J Roentgenol 183(5):1319–1326PubMed Giorgio A, Ferraioli G, Tarantino L et al (2004) Contrast-enhanced sonographic appearance of hepatocellular carcinoma in patients with cirrhosis: comparison with contrast-enhanced helical CT appearance. AJR Am J Roentgenol 183(5):1319–1326PubMed
26.
Zurück zum Zitat Farny CH, Glynn Holt R, Roy RA (2010) The correlation between bubble-enhanced HIFU heating and cavitation power. IEEE Trans Biomed Eng 57(1):175–184PubMedCrossRef Farny CH, Glynn Holt R, Roy RA (2010) The correlation between bubble-enhanced HIFU heating and cavitation power. IEEE Trans Biomed Eng 57(1):175–184PubMedCrossRef
27.
Zurück zum Zitat Sasaki K, Medan MS, Azuma T, Umemura S et al (2006) Effect of echo-guided high-intensity focused ultrasound ablation on localized experimental tumors. J Vet Med Sci 68(10):1069–1074PubMedCrossRef Sasaki K, Medan MS, Azuma T, Umemura S et al (2006) Effect of echo-guided high-intensity focused ultrasound ablation on localized experimental tumors. J Vet Med Sci 68(10):1069–1074PubMedCrossRef
28.
Zurück zum Zitat Jaspers K, Nijenhuis RJ, Backes WH (2007) Differentiation of spinal cord arteries and veins by time-resolved MR angiography. J Magn Reson Imaging 26(1):31–40PubMedCrossRef Jaspers K, Nijenhuis RJ, Backes WH (2007) Differentiation of spinal cord arteries and veins by time-resolved MR angiography. J Magn Reson Imaging 26(1):31–40PubMedCrossRef
29.
Zurück zum Zitat Kato T, Nemoto R, Mori H et al (1984) Magnetic microcapsules for targeted delivery of anticancer drugs. Appl Biochem Biotechnol 10:199–211PubMedCrossRef Kato T, Nemoto R, Mori H et al (1984) Magnetic microcapsules for targeted delivery of anticancer drugs. Appl Biochem Biotechnol 10:199–211PubMedCrossRef
30.
Zurück zum Zitat Maruyama H, Matsutani S, Saisho H et al (2005) Sonographic shift of hypervascular liver tumor on blood pool harmonic images with definity: time-related changes of contrast-enhanced appearance in rabbit VX2 tumor under extra-low acoustic power. Eur J Radiol 56(1):60–65PubMedCrossRef Maruyama H, Matsutani S, Saisho H et al (2005) Sonographic shift of hypervascular liver tumor on blood pool harmonic images with definity: time-related changes of contrast-enhanced appearance in rabbit VX2 tumor under extra-low acoustic power. Eur J Radiol 56(1):60–65PubMedCrossRef
31.
Zurück zum Zitat Zhao JG, Feng GS, Kong XQ et al (2004) Changes of tumor microcirculation after transcatheter arterial chemoembolization: first pass perfusion MR imaging and Chinese ink casting in a rabbit model. World J Gastroenterol 10(10):1415–1420PubMed Zhao JG, Feng GS, Kong XQ et al (2004) Changes of tumor microcirculation after transcatheter arterial chemoembolization: first pass perfusion MR imaging and Chinese ink casting in a rabbit model. World J Gastroenterol 10(10):1415–1420PubMed
Metadaten
Titel
Enhanced Ablation of High Intensity Focused Ultrasound with Microbubbles: An Experimental Study on Rabbit Hepatic VX2 Tumors
verfasst von
Wei He
Wei Wang
Ping Zhou
Yi-Xiang J. Wang
Peng Zhou
Rui-Zhen Li
Jin-Sheng Wang
Anil T. Ahuja
Publikationsdatum
01.10.2011
Verlag
Springer-Verlag
Erschienen in
CardioVascular and Interventional Radiology / Ausgabe 5/2011
Print ISSN: 0174-1551
Elektronische ISSN: 1432-086X
DOI
https://doi.org/10.1007/s00270-010-0052-3

Weitere Artikel der Ausgabe 5/2011

CardioVascular and Interventional Radiology 5/2011 Zur Ausgabe

Update Radiologie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.