Skip to main content
Erschienen in: CardioVascular and Interventional Radiology 3/2012

01.06.2012 | Clinical Investigation

Radiation Exposure in Nonvascular Fluoroscopy-Guided Interventional Procedures

verfasst von: Roman Kloeckner, Anton Bersch, Daniel Pinto dos Santos, Jens Schneider, Christoph Düber, Michael Bernhard Pitton

Erschienen in: CardioVascular and Interventional Radiology | Ausgabe 3/2012

Einloggen, um Zugang zu erhalten

Abstract

Purpose

To investigate the radiation exposure in non-vascular fluoroscopy guided interventions and to search strategies for dose reduction.

Materials and Methods

Dose area product (DAP) of 638 consecutive non-vascular interventional procedures of one year were analyzed with respect to different types of interventions; gastrointestinal tract, biliary interventions, embolizations of tumors and hemorrhage. Data was analyzed with special focus on the fluoroscopy doses and frame doses. The third quartiles (Q3) of fluoroscopy dose values were defined in order to set a reference value for our in-hospital practice.

Results

Mean fluoroscopy times of gastrostomy, jejunostomy, right and left sided percutaneous biliary drainage, chemoembolization of the liver and embolization due to various hemorrhages were 5.9, 8.6, 13.5, 16.6, 17.4 and 25.2 min, respectively. The respective Q3 total DAP were 52.9, 73.3, 155.1, 308.4, 428.6 and 529.3 Gy*cm2. Overall, around 66% of the total DAP originated from the radiographic frames with only 34% of the total DAP applied by fluoroscopy (P < 0.001). The investigators experience had no significant impact on the total DAP applied, most likely since there was no stratification to intervention-complexity.

Conclusion

To establish Diagnostic Reference Levels (DRLs), there is a need to establish a registry of radiation dose data for the most commonly performed procedures. Documentation of interventional procedures by fluoroscopy “grabbing” has the potential to considerably reduce radiation dose applied and should be used instead of radiographic frames whenever possible.
Literatur
1.
Zurück zum Zitat Miller DL (2008) Overview of contemporary interventional fluoroscopy procedures. Health Phys 95(5):638–644PubMedCrossRef Miller DL (2008) Overview of contemporary interventional fluoroscopy procedures. Health Phys 95(5):638–644PubMedCrossRef
2.
Zurück zum Zitat Valentin J (2000) Avoidance of radiation injuries from medical interventional procedures. Ann ICRP 30(2):7–67PubMedCrossRef Valentin J (2000) Avoidance of radiation injuries from medical interventional procedures. Ann ICRP 30(2):7–67PubMedCrossRef
3.
Zurück zum Zitat Chida K, Kato M, Kagaya Y et al (2010) Radiation dose and radiation protection for patients and physicians during interventional procedure. J Radiat Res 51(2):97–105PubMedCrossRef Chida K, Kato M, Kagaya Y et al (2010) Radiation dose and radiation protection for patients and physicians during interventional procedure. J Radiat Res 51(2):97–105PubMedCrossRef
4.
Zurück zum Zitat Vano E, Sanchez R, Fernandez JM et al (2009) Patient dose reference levels for interventional radiology: a national approach. Cardiovasc Interv Radiol 32(1):19–24CrossRef Vano E, Sanchez R, Fernandez JM et al (2009) Patient dose reference levels for interventional radiology: a national approach. Cardiovasc Interv Radiol 32(1):19–24CrossRef
5.
Zurück zum Zitat Strahlenschutzkommission Cfrp (2008) Interventional radiology––recommendations for radiation protection. Bull Comm Radiat Prot 56:1–58 Strahlenschutzkommission Cfrp (2008) Interventional radiology––recommendations for radiation protection. Bull Comm Radiat Prot 56:1–58
6.
Zurück zum Zitat Wall BF, Shrimpton PC (1998) The historical development of reference doses in diagnostic radiology. Radiat Prot Dosim 80(1–3):15–20CrossRef Wall BF, Shrimpton PC (1998) The historical development of reference doses in diagnostic radiology. Radiat Prot Dosim 80(1–3):15–20CrossRef
7.
Zurück zum Zitat International Commission on Radiological Protection (2001) Diagnostic reference levels in medical imaging: review and additional advice. Ann ICRP 31(4):33–52 International Commission on Radiological Protection (2001) Diagnostic reference levels in medical imaging: review and additional advice. Ann ICRP 31(4):33–52
8.
Zurück zum Zitat ICRP (2007) Radiological protection in medicine. ICRP Publication 105. Ann ICRP 37(6):1–63 ICRP (2007) Radiological protection in medicine. ICRP Publication 105. Ann ICRP 37(6):1–63
9.
Zurück zum Zitat Nosske D (2010) Updated reference levels in diagnostic and interventional radiology. In: Federal Bulletin. Federal office for Radiation protection, Salzgitter, Germany Nosske D (2010) Updated reference levels in diagnostic and interventional radiology. In: Federal Bulletin. Federal office for Radiation protection, Salzgitter, Germany
10.
Zurück zum Zitat Vano E, Jarvinen H, Kosunen A et al (2008) Patient dose in interventional radiology: a European survey. Radiat Prot Dosim 129(1–3):39–45CrossRef Vano E, Jarvinen H, Kosunen A et al (2008) Patient dose in interventional radiology: a European survey. Radiat Prot Dosim 129(1–3):39–45CrossRef
11.
Zurück zum Zitat Aroua A, Rickli H, Stauffer JC et al (2007) How to set up and apply reference levels in fluoroscopy at a national level. Eur Radiol 17(6):1621–1633PubMedCrossRef Aroua A, Rickli H, Stauffer JC et al (2007) How to set up and apply reference levels in fluoroscopy at a national level. Eur Radiol 17(6):1621–1633PubMedCrossRef
12.
Zurück zum Zitat Miller DL, Balter S, Cole PE et al (2003) Radiation doses in interventional radiology procedures: the RAD-IR study. Part I: Overall measures of dose. J Vasc Interv Radiol 14(6):711–727PubMedCrossRef Miller DL, Balter S, Cole PE et al (2003) Radiation doses in interventional radiology procedures: the RAD-IR study. Part I: Overall measures of dose. J Vasc Interv Radiol 14(6):711–727PubMedCrossRef
13.
Zurück zum Zitat Ruiz Cruces R, Garcia-Granados J, Diaz Romero FJ, Hernandez Armas J (1998) Estimation of effective dose in some digital angiographic and interventional procedures. Br J Radiol 71(841):42–47PubMed Ruiz Cruces R, Garcia-Granados J, Diaz Romero FJ, Hernandez Armas J (1998) Estimation of effective dose in some digital angiographic and interventional procedures. Br J Radiol 71(841):42–47PubMed
14.
Zurück zum Zitat Zweers D, Geleijns J, Aarts NJ et al (1998) Patient and staff radiation dose in fluoroscopy-guided TIPS procedures and dose decrease using dedicated fluoroscopy exposure settings. Br J Radiol 71(846):672–676PubMed Zweers D, Geleijns J, Aarts NJ et al (1998) Patient and staff radiation dose in fluoroscopy-guided TIPS procedures and dose decrease using dedicated fluoroscopy exposure settings. Br J Radiol 71(846):672–676PubMed
15.
Zurück zum Zitat Ruiz-Cruces R, Perez-Martinez M, Martin-Palanca A et al (1997) Patient dose in radiologically guided interventional vascular procedures: conventional versus digital systems. Radiology 205(2):385–393PubMed Ruiz-Cruces R, Perez-Martinez M, Martin-Palanca A et al (1997) Patient dose in radiologically guided interventional vascular procedures: conventional versus digital systems. Radiology 205(2):385–393PubMed
16.
Zurück zum Zitat Kuon E, Robinson DM, Empen K, Dahm JB (2005) Fluoroscopy time––an overestimated factor for patient radiation exposure in invasive cardiology. Fortschr Geb Rontgenstrahlen Neuen Bildgeb Verfahr Erganzungsbd 177(6):812–817CrossRef Kuon E, Robinson DM, Empen K, Dahm JB (2005) Fluoroscopy time––an overestimated factor for patient radiation exposure in invasive cardiology. Fortschr Geb Rontgenstrahlen Neuen Bildgeb Verfahr Erganzungsbd 177(6):812–817CrossRef
17.
Zurück zum Zitat Mavrikou I, Kottou S, Tsapaki V, Neofotistou V (2008) High patient doses in interventional cardiology due to physicians′ negligence: How can they be prevented? Radiat Prot Dosim 129(1–3):67–70CrossRef Mavrikou I, Kottou S, Tsapaki V, Neofotistou V (2008) High patient doses in interventional cardiology due to physicians′ negligence: How can they be prevented? Radiat Prot Dosim 129(1–3):67–70CrossRef
18.
Zurück zum Zitat Miller DL, Vano E, Bartal G et al (2009) Occupational radiation protection for interventionalists: a joint Guideline of the Cardiovascular and Interventional Radiology Society of Europe and the Society of Interventional Radiology. CIRSE SOP guideline, pp 1–18. http://www.cirse.org/index.php?pid=412 Miller DL, Vano E, Bartal G et al (2009) Occupational radiation protection for interventionalists: a joint Guideline of the Cardiovascular and Interventional Radiology Society of Europe and the Society of Interventional Radiology. CIRSE SOP guideline, pp 1–18. http://​www.​cirse.​org/​index.​php?​pid=​412
19.
Zurück zum Zitat Stecker MS, Balter S, Towbin RB et al (2009) Guidelines for patient radiation dose management. J Vasc Interv Radiol 20(7):S263–S273PubMedCrossRef Stecker MS, Balter S, Towbin RB et al (2009) Guidelines for patient radiation dose management. J Vasc Interv Radiol 20(7):S263–S273PubMedCrossRef
20.
Zurück zum Zitat Vano E, Gonzalez L, Fernandez JM, Prieto C, Guibelalde E (2006) Influence of patient thickness and operation modes on occupational and patient radiation doses in interventional cardiology. Radiat Prot Dosim 118(3):325–330CrossRef Vano E, Gonzalez L, Fernandez JM, Prieto C, Guibelalde E (2006) Influence of patient thickness and operation modes on occupational and patient radiation doses in interventional cardiology. Radiat Prot Dosim 118(3):325–330CrossRef
21.
Zurück zum Zitat Miller DL, Kwon D, Bonavia GH (2009) Reference levels for patient radiation doses in interventional radiology: proposed initial values for US practice. Radiology 253(3):753–764PubMedCrossRef Miller DL, Kwon D, Bonavia GH (2009) Reference levels for patient radiation doses in interventional radiology: proposed initial values for US practice. Radiology 253(3):753–764PubMedCrossRef
22.
Zurück zum Zitat d’Othee BJ, Lin PJ (2007) The influence of angiography table shields and height on patient and angiographer irradiation during interventional radiology procedures. Cardiovasc Intervent Radiol 30(3):448–454PubMedCrossRef d’Othee BJ, Lin PJ (2007) The influence of angiography table shields and height on patient and angiographer irradiation during interventional radiology procedures. Cardiovasc Intervent Radiol 30(3):448–454PubMedCrossRef
23.
Zurück zum Zitat Samara ET, Aroua A, De Palma R et al (2011) An audit of diagnostic reference levels in interventional cardiology and radiology: are there differences between academic and non-academic centres? Radiat Prot Dosim Samara ET, Aroua A, De Palma R et al (2011) An audit of diagnostic reference levels in interventional cardiology and radiology: are there differences between academic and non-academic centres? Radiat Prot Dosim
24.
Zurück zum Zitat Balter S (2008) Capturing patient doses from fluoroscopically based diagnostic and interventional systems. Health Phys 95(5):535–540PubMedCrossRef Balter S (2008) Capturing patient doses from fluoroscopically based diagnostic and interventional systems. Health Phys 95(5):535–540PubMedCrossRef
25.
Zurück zum Zitat Verdun FR, Aroua A, Trueb PR, Vock P, Valley JF (2005) Diagnostic and interventional radiology: a strategy to introduce reference dose level taking into account the national practice. Radiat Prot Dosim 114(1–3):188–191CrossRef Verdun FR, Aroua A, Trueb PR, Vock P, Valley JF (2005) Diagnostic and interventional radiology: a strategy to introduce reference dose level taking into account the national practice. Radiat Prot Dosim 114(1–3):188–191CrossRef
26.
Zurück zum Zitat Bor D, Sancak T, Toklu T, Olgar T, Ener S (2008) Effects of radiologists’ skill and experience on patient doses in interventional examinations. Radiat Prot Dosim 129(1–3):32–35CrossRef Bor D, Sancak T, Toklu T, Olgar T, Ener S (2008) Effects of radiologists’ skill and experience on patient doses in interventional examinations. Radiat Prot Dosim 129(1–3):32–35CrossRef
27.
Zurück zum Zitat Vehmas T (1997) Radiation exposure during standard and complex interventional procedures. Br J Radiol 70:296–298PubMed Vehmas T (1997) Radiation exposure during standard and complex interventional procedures. Br J Radiol 70:296–298PubMed
28.
Zurück zum Zitat Wall BF (2001) Diagnostic reference levels––the way forward. Br J Radiol 74(885):785–788PubMed Wall BF (2001) Diagnostic reference levels––the way forward. Br J Radiol 74(885):785–788PubMed
29.
Zurück zum Zitat Vano E, Gonzalez L (2001) Approaches to establishing reference levels in interventional radiology. Radiat Prot Dosim 94(1–2):109–112CrossRef Vano E, Gonzalez L (2001) Approaches to establishing reference levels in interventional radiology. Radiat Prot Dosim 94(1–2):109–112CrossRef
30.
Zurück zum Zitat Board NRP (1990) Patient dose decrease in diagnostic radiology: Report by the Royal College of Radiologists and the National Radiological Protection Board. Doc NRPB 1(3):1–46 Board NRP (1990) Patient dose decrease in diagnostic radiology: Report by the Royal College of Radiologists and the National Radiological Protection Board. Doc NRPB 1(3):1–46
31.
Zurück zum Zitat Castellano IA, McNeill JG, Thorp NC, Dance DR, Raphael MJ (1995) Assessment of organ radiation doses and associated risk for digital bifemoral arteriography. Br J Radiol 68(809):502–507PubMedCrossRef Castellano IA, McNeill JG, Thorp NC, Dance DR, Raphael MJ (1995) Assessment of organ radiation doses and associated risk for digital bifemoral arteriography. Br J Radiol 68(809):502–507PubMedCrossRef
32.
Zurück zum Zitat McParland BJ (1998) A study of patient radiation doses in interventional radiological procedures. Br J Radiol 71(842):175–185PubMed McParland BJ (1998) A study of patient radiation doses in interventional radiological procedures. Br J Radiol 71(842):175–185PubMed
33.
Zurück zum Zitat Vano E, Gonzalez L, Ten JI, Fernandez JM, Guibelalde E, Macaya C (2001) Skin dose and dose-area product values for interventional cardiology procedures. Br J Radiol 74(877):48–55PubMed Vano E, Gonzalez L, Ten JI, Fernandez JM, Guibelalde E, Macaya C (2001) Skin dose and dose-area product values for interventional cardiology procedures. Br J Radiol 74(877):48–55PubMed
34.
Zurück zum Zitat van de Putte S, Verhaegen F, Taeymans Y, Thierens H (2000) Correlation of patient skin doses in cardiac interventional radiology with dose-area product. Br J Radiol 73(869):504–513PubMed van de Putte S, Verhaegen F, Taeymans Y, Thierens H (2000) Correlation of patient skin doses in cardiac interventional radiology with dose-area product. Br J Radiol 73(869):504–513PubMed
35.
Zurück zum Zitat Marshall NW, Chapple CL, Kotre CJ (2000) Diagnostic reference levels in interventional radiology. Phys Med Biol 45(12):3833–3846PubMedCrossRef Marshall NW, Chapple CL, Kotre CJ (2000) Diagnostic reference levels in interventional radiology. Phys Med Biol 45(12):3833–3846PubMedCrossRef
Metadaten
Titel
Radiation Exposure in Nonvascular Fluoroscopy-Guided Interventional Procedures
verfasst von
Roman Kloeckner
Anton Bersch
Daniel Pinto dos Santos
Jens Schneider
Christoph Düber
Michael Bernhard Pitton
Publikationsdatum
01.06.2012
Verlag
Springer-Verlag
Erschienen in
CardioVascular and Interventional Radiology / Ausgabe 3/2012
Print ISSN: 0174-1551
Elektronische ISSN: 1432-086X
DOI
https://doi.org/10.1007/s00270-011-0206-y

Weitere Artikel der Ausgabe 3/2012

CardioVascular and Interventional Radiology 3/2012 Zur Ausgabe

Update Radiologie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.