Skip to main content
Erschienen in: CardioVascular and Interventional Radiology 5/2013

01.10.2013 | Clinical Investigation

Transarterial Embolization of Type II Endoleaks after EVAR: The Role of Ethylene Vinyl Alcohol Copolymer (Onyx)

verfasst von: René Müller-Wille, Walter A. Wohlgemuth, Peter Heiss, Philipp Wiggermann, Oliver Güntner, Andreas G. Schreyer, Patrick Hoffstetter, Christian Stroszczynski, Niels Zorger

Erschienen in: CardioVascular and Interventional Radiology | Ausgabe 5/2013

Einloggen, um Zugang zu erhalten

Abstract

Purpose

To determine the feasibility and efficacy of transarterial endoleak embolization using the liquid embolic agent ethylene vinyl alcohol copolymer (Onyx).

Methods

Over a 7-year period eleven patients (6 women, 5 men; mean age 68 years, range 37–83 years) underwent transarterial embolization of a type II endoleak after endovascular aortic aneurysm repair using the liquid embolic agent Onyx. Two patients (18 %) had a simple type II endoleak with only one artery in communication with the aneurysm sac, whereas 9 patients (82 %) had a complex type II endoleak with multiple communicating vessels. We retrospectively analyzed the technical and clinical success of transarterial type II endoleak embolization with Onyx. Complete embolization of the nidus was defined as technical success. Embolization was considered clinically successful when volume of the aneurysm sac was stable or decreased on follow-up CT scans.

Result

Mean follow-up time was 26.0 (range 6–50) months. Clinical success was achieved in 8 of 11 patients (73 %). Transarterial nidus embolization with Onyx was technically successful in 6 of 11 patients (55 %). In three cases the nidus was embolized without direct catheterization from a more distal access through the network of collateral vessels.

Conclusion

Onyx is a favorable embolic agent for transarterial endoleak embolization. To achieve the best clinical results, complete occlusion of the nidus is mandatory.
Literatur
1.
Zurück zum Zitat Nevala T, Biancari F, Manninen H et al (2010) Type II endoleak after endovascular repair of abdominal aortic aneurysm: effectiveness of embolization. Cardiovasc Intervent Radiol 33:278–284PubMedCrossRef Nevala T, Biancari F, Manninen H et al (2010) Type II endoleak after endovascular repair of abdominal aortic aneurysm: effectiveness of embolization. Cardiovasc Intervent Radiol 33:278–284PubMedCrossRef
2.
Zurück zum Zitat Jones JE, Atkins MD, Brewster DC et al (2007) Persistent type 2 endoleak after endovascular repair of abdominal aortic aneurysm is associated with adverse late outcomes. J Vasc Surg 46:1–8PubMedCrossRef Jones JE, Atkins MD, Brewster DC et al (2007) Persistent type 2 endoleak after endovascular repair of abdominal aortic aneurysm is associated with adverse late outcomes. J Vasc Surg 46:1–8PubMedCrossRef
3.
Zurück zum Zitat Solis MM, Ayerdi J, Babcock GA et al (2002) Mechanism of failure in the treatment of type II endoleak with percutaneous coil embolization. J Vasc Surg 36:485–491PubMedCrossRef Solis MM, Ayerdi J, Babcock GA et al (2002) Mechanism of failure in the treatment of type II endoleak with percutaneous coil embolization. J Vasc Surg 36:485–491PubMedCrossRef
4.
Zurück zum Zitat Higashiura W, Greenberg RK, Katz E et al (2007) Predictive factors, morphologic effects, and proposed treatment paradigm for type II endoleaks after repair of infrarenal abdominal aortic aneurysms. J Vasc Interv Radiol 18:975–981PubMedCrossRef Higashiura W, Greenberg RK, Katz E et al (2007) Predictive factors, morphologic effects, and proposed treatment paradigm for type II endoleaks after repair of infrarenal abdominal aortic aneurysms. J Vasc Interv Radiol 18:975–981PubMedCrossRef
5.
Zurück zum Zitat van Marrewijk CJ, Fransen G, Laheij RJ et al (2004) Is a type II endoleak after EVAR a harbinger of risk? Causes and outcome of open conversion and aneurysm rupture during follow-up. Eur J Vasc Endovasc Surg 27:128–137PubMedCrossRef van Marrewijk CJ, Fransen G, Laheij RJ et al (2004) Is a type II endoleak after EVAR a harbinger of risk? Causes and outcome of open conversion and aneurysm rupture during follow-up. Eur J Vasc Endovasc Surg 27:128–137PubMedCrossRef
6.
Zurück zum Zitat Schlosser FJ, Gusberg RJ, Dardik A et al (2009) Aneurysm rupture after EVAR: Can the ultimate failure be predicted? Eur J Vasc Endovasc Surg 37:15–22PubMedCrossRef Schlosser FJ, Gusberg RJ, Dardik A et al (2009) Aneurysm rupture after EVAR: Can the ultimate failure be predicted? Eur J Vasc Endovasc Surg 37:15–22PubMedCrossRef
7.
Zurück zum Zitat White RA, Donayre C, Walot I, Stewart M (2000) Abdominal aortic aneurysm rupture following endoluminal graft deployment: report of a predictable event. J Endovasc Ther 7:257–262PubMedCrossRef White RA, Donayre C, Walot I, Stewart M (2000) Abdominal aortic aneurysm rupture following endoluminal graft deployment: report of a predictable event. J Endovasc Ther 7:257–262PubMedCrossRef
8.
Zurück zum Zitat Baum RA, Carpenter JP, Tuite CM et al (2000) Diagnosis and treatment of inferior mesenteric arterial endoleaks after endovascular repair of abdominal aortic aneurysms. Radiology 215:409–413PubMed Baum RA, Carpenter JP, Tuite CM et al (2000) Diagnosis and treatment of inferior mesenteric arterial endoleaks after endovascular repair of abdominal aortic aneurysms. Radiology 215:409–413PubMed
9.
Zurück zum Zitat Kato N, Semba CP, Dake MD (1996) Embolization of perigraft leaks after endovascular stent-graft treatment of aortic aneurysms. J Vasc Interv Radiol 7:805–811PubMedCrossRef Kato N, Semba CP, Dake MD (1996) Embolization of perigraft leaks after endovascular stent-graft treatment of aortic aneurysms. J Vasc Interv Radiol 7:805–811PubMedCrossRef
10.
Zurück zum Zitat Stavropoulos SW, Park J, Fairman R, Carpenter J (2009) Type 2 endoleak embolization comparison: translumbar embolization versus modified transarterial embolization. J Vasc Interv Radiol 20:1299–1302PubMedCrossRef Stavropoulos SW, Park J, Fairman R, Carpenter J (2009) Type 2 endoleak embolization comparison: translumbar embolization versus modified transarterial embolization. J Vasc Interv Radiol 20:1299–1302PubMedCrossRef
11.
Zurück zum Zitat Wilmot A, Stavropoulos SW (2007) Embolization of a recurrent type 2 endoleak using the liquid embolic n-butyl cyanoacrylate. Semin Intervent Radiol 24:38–42PubMedCrossRef Wilmot A, Stavropoulos SW (2007) Embolization of a recurrent type 2 endoleak using the liquid embolic n-butyl cyanoacrylate. Semin Intervent Radiol 24:38–42PubMedCrossRef
12.
Zurück zum Zitat Ling AJ, Pathak R, Garbowski M, Nadkarni S (2007) Treatment of a large type II endoleak via extraperitoneal dissection and embolization of a collateral vessel using ethylene vinyl alcohol copolymer (Onyx). J Vasc Interv Radiol 18:659–662PubMedCrossRef Ling AJ, Pathak R, Garbowski M, Nadkarni S (2007) Treatment of a large type II endoleak via extraperitoneal dissection and embolization of a collateral vessel using ethylene vinyl alcohol copolymer (Onyx). J Vasc Interv Radiol 18:659–662PubMedCrossRef
13.
Zurück zum Zitat Martin ML, Dolmatch BL, Fry PD, Machan LS (2001) Treatment of type II endoleaks with Onyx. J Vasc Interv Radiol 12:629–632PubMedCrossRef Martin ML, Dolmatch BL, Fry PD, Machan LS (2001) Treatment of type II endoleaks with Onyx. J Vasc Interv Radiol 12:629–632PubMedCrossRef
14.
Zurück zum Zitat Chaikof EL, Blankensteijn JD, Harris PL et al (2002) Reporting standards for endovascular aortic aneurysm repair. J Vasc Surg 35:1048–1060PubMedCrossRef Chaikof EL, Blankensteijn JD, Harris PL et al (2002) Reporting standards for endovascular aortic aneurysm repair. J Vasc Surg 35:1048–1060PubMedCrossRef
15.
Zurück zum Zitat Baum RA, Carpenter JP, Golden MA et al (2002) Treatment of type 2 endoleaks after endovascular repair of abdominal aortic aneurysms: comparison of transarterial and translumbar techniques. J Vasc Surg 35:23–29PubMed Baum RA, Carpenter JP, Golden MA et al (2002) Treatment of type 2 endoleaks after endovascular repair of abdominal aortic aneurysms: comparison of transarterial and translumbar techniques. J Vasc Surg 35:23–29PubMed
16.
Zurück zum Zitat Stavropoulos SW, Kim H, Clark TW et al (2005) Embolization of type 2 endoleaks after endovascular repair of abdominal aortic aneurysms with use of cyanoacrylate with or without coils. J Vasc Interv Radiol 16:857–861PubMedCrossRef Stavropoulos SW, Kim H, Clark TW et al (2005) Embolization of type 2 endoleaks after endovascular repair of abdominal aortic aneurysms with use of cyanoacrylate with or without coils. J Vasc Interv Radiol 16:857–861PubMedCrossRef
17.
Zurück zum Zitat Mansueto G, Cenzi D, D’Onofrio M et al (2005) Treatment of type II endoleaks after endovascular repair of abdominal aortic aneurysms: transcaval approach. Cardiovasc Intervent Radiol 28:641–645PubMedCrossRef Mansueto G, Cenzi D, D’Onofrio M et al (2005) Treatment of type II endoleaks after endovascular repair of abdominal aortic aneurysms: transcaval approach. Cardiovasc Intervent Radiol 28:641–645PubMedCrossRef
18.
Zurück zum Zitat Bailey MA, McPherson SJ, Troxler MA et al (2011) Ischemic skin ulceration complicating glue embolization of type II endoleak after endovascular aneurysm repair. J Vasc Interv Radiol 22:163–167PubMedCrossRef Bailey MA, McPherson SJ, Troxler MA et al (2011) Ischemic skin ulceration complicating glue embolization of type II endoleak after endovascular aneurysm repair. J Vasc Interv Radiol 22:163–167PubMedCrossRef
19.
Zurück zum Zitat Forester ND, Parry D, Kessel D et al (2002) Ischaemic sciatic neuropathy: an important complication of embolisation of a type II endoleak. Eur J Vasc Endovasc Surg 24:462–463PubMedCrossRef Forester ND, Parry D, Kessel D et al (2002) Ischaemic sciatic neuropathy: an important complication of embolisation of a type II endoleak. Eur J Vasc Endovasc Surg 24:462–463PubMedCrossRef
20.
Zurück zum Zitat Stone JR, Evans AJ, Angle JF et al (2009) In vitro assessment of aortic stent-graft integrity following exposure to Onyx liquid embolic agent. J Vasc Interv Radiol 20:107–112PubMedCrossRef Stone JR, Evans AJ, Angle JF et al (2009) In vitro assessment of aortic stent-graft integrity following exposure to Onyx liquid embolic agent. J Vasc Interv Radiol 20:107–112PubMedCrossRef
21.
Zurück zum Zitat Chaloupka JC, Vinuela F, Vinters HV, Robert J (1994) Technical feasibility and histopathologic studies of ethylene vinyl copolymer (EVAL) using a swine endovascular embolization model. AJNR Am J Neuroradiol 15:1107–1115PubMed Chaloupka JC, Vinuela F, Vinters HV, Robert J (1994) Technical feasibility and histopathologic studies of ethylene vinyl copolymer (EVAL) using a swine endovascular embolization model. AJNR Am J Neuroradiol 15:1107–1115PubMed
Metadaten
Titel
Transarterial Embolization of Type II Endoleaks after EVAR: The Role of Ethylene Vinyl Alcohol Copolymer (Onyx)
verfasst von
René Müller-Wille
Walter A. Wohlgemuth
Peter Heiss
Philipp Wiggermann
Oliver Güntner
Andreas G. Schreyer
Patrick Hoffstetter
Christian Stroszczynski
Niels Zorger
Publikationsdatum
01.10.2013
Verlag
Springer US
Erschienen in
CardioVascular and Interventional Radiology / Ausgabe 5/2013
Print ISSN: 0174-1551
Elektronische ISSN: 1432-086X
DOI
https://doi.org/10.1007/s00270-013-0567-5

Weitere Artikel der Ausgabe 5/2013

CardioVascular and Interventional Radiology 5/2013 Zur Ausgabe

Update Radiologie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.