Abstract

Longitudinal axial rotations of phalanges during flexion motions of digits have scarcely been analyzed with current anatomical or radiological methods. Recent optoelectronic systems were developed for three-dimensional (3D) kinematic analysis of human motion. These systems have the advantages of being non-invasive and non-irradiating. The current study was based on the VICON optoelectronic system. A validation of the protocol was made among a sample of volunteers for further direct clinical applications. An experimental protocol was set up with adaptations to the requirements of finger analyses (multiple infrared markers inside small-sized capture volumes). The set-up and the protocol details are described. Kinematic studies consisted in recording the movements of the right hand of six volunteers (free from any visible pathology). Results were displayed for the joints of each three-joint finger with calculation of 3D rotations. Metacarpophalangeal (MCP), proximal interphalangeal (PIP) and distal interphalangeal (DIP) flexion angles ranged from 78° to 118°, 72° to 119° and 9° to 66° respectively. Lateral angles ranged from 5° to 39° (MCP), 4° to 39° (PIP) and 4° to 30° (DIP). Mean longitudinal axial rotations of MCP, PIP and DIP joints ranged from 11° pronation to 26° supination. The index finger was in a global pronation position (five of the six specimens). The fourth and fifth fingers were in a global supination position in every case. The third finger was in a more variable global rotation (pronation in four of the six specimens). An experimental protocol using an optoelectronic system (VICON) has been developed for a kinematic analysis of three-joint finger. A global measure study should be initiated among a wider sample of adults. A database should be created with direct clinical applications. Patients’ kinematic deficits could be graded either for standard movements (flexion/extension and abduction/adduction) or for longitudinal axial rotations.
Literatur
1.
Zurück zum Zitat Abdel-Aziz Y, Karara H (1971) Direct linear transformation from comparator coordinates into object space coordinates in close-range photogrammetry. Proceedings of the American Society of Photogrammetry, Symposium on close-range photogrammetry Abdel-Aziz Y, Karara H (1971) Direct linear transformation from comparator coordinates into object space coordinates in close-range photogrammetry. Proceedings of the American Society of Photogrammetry, Symposium on close-range photogrammetry
2.
Zurück zum Zitat Buchholz B, Armstrong TJ, Goldstein SA (1992) Anthropometric data for describing the kinematics of the human hand. Ergonomics 35:261–273PubMed Buchholz B, Armstrong TJ, Goldstein SA (1992) Anthropometric data for describing the kinematics of the human hand. Ergonomics 35:261–273PubMed
3.
Zurück zum Zitat Chao EY (1980) Justification of triaxial goniometer for the measurement of joint rotation. J Biomech 13:989–1006CrossRefPubMed Chao EY (1980) Justification of triaxial goniometer for the measurement of joint rotation. J Biomech 13:989–1006CrossRefPubMed
4.
Zurück zum Zitat Cheze L, Doriot N, Eckert M, Rumelhart C, Comtet JJ (2001) Etude cinématique in vivo de l’articulation trapézo-métacarpienne. Chir Main 20:23–30CrossRefPubMed Cheze L, Doriot N, Eckert M, Rumelhart C, Comtet JJ (2001) Etude cinématique in vivo de l’articulation trapézo-métacarpienne. Chir Main 20:23–30CrossRefPubMed
5.
Zurück zum Zitat Chiu HY, Su FC, Wang ST (1998) The motion analysis system and the fingertip motion area. Normal values in young adults. J Hand Surg [Br] 23:53–56 Chiu HY, Su FC, Wang ST (1998) The motion analysis system and the fingertip motion area. Normal values in young adults. J Hand Surg [Br] 23:53–56
6.
Zurück zum Zitat Chiu HY, Lin SC, Su FC, Wang ST, Hsu HY (2000) The use of the motion analysis system for evaluation of loss of movement in the finger. J Hand Surg [Br] 25:195–199 Chiu HY, Lin SC, Su FC, Wang ST, Hsu HY (2000) The use of the motion analysis system for evaluation of loss of movement in the finger. J Hand Surg [Br] 25:195–199
7.
Zurück zum Zitat Degeorges R, Oberlin C (2003) Measurement of three-joint-finger motions: reality or fancy? A three-dimensional anatomical approach. Surg Radiol Anat 25:105–112CrossRefPubMed Degeorges R, Oberlin C (2003) Measurement of three-joint-finger motions: reality or fancy? A three-dimensional anatomical approach. Surg Radiol Anat 25:105–112CrossRefPubMed
8.
Zurück zum Zitat Degeorges R, Laporte S, Pessis E, Mitton D, Goubier JN, Lavaste F (2004) Rotations of three joint fingers: a radiological study. Surg Radiol Anat (in press) Degeorges R, Laporte S, Pessis E, Mitton D, Goubier JN, Lavaste F (2004) Rotations of three joint fingers: a radiological study. Surg Radiol Anat (in press)
9.
Zurück zum Zitat Dubousset JF (1980) Les articulations des doigts. In: Tubiana R (ed) Traité de chirurgie de la main, vol 1. Masson, Paris, pp 227–233 Dubousset JF (1980) Les articulations des doigts. In: Tubiana R (ed) Traité de chirurgie de la main, vol 1. Masson, Paris, pp 227–233
10.
Zurück zum Zitat Dubousset JF (1981) Finger rotation during prehension. In: Tubiana R (ed) The hand, vol 1. WB Saunders, Philadelphia, pp 202–206 Dubousset JF (1981) Finger rotation during prehension. In: Tubiana R (ed) The hand, vol 1. WB Saunders, Philadelphia, pp 202–206
11.
Zurück zum Zitat Ehara Y, Miyazaki S, Mochimaru M, Tanaka S, Yamamoto S (1997) Comparison of the performance of 3D camera systems: II. Gait Posture 5:251–255CrossRef Ehara Y, Miyazaki S, Mochimaru M, Tanaka S, Yamamoto S (1997) Comparison of the performance of 3D camera systems: II. Gait Posture 5:251–255CrossRef
12.
Zurück zum Zitat Faraway JJ, Zhang X, Caffin DB (1999) Rectifying postures reconstructed from joint angles to meet constraints. J Biomech 32:733–736CrossRefPubMed Faraway JJ, Zhang X, Caffin DB (1999) Rectifying postures reconstructed from joint angles to meet constraints. J Biomech 32:733–736CrossRefPubMed
13.
Zurück zum Zitat Fowler NK, Nicol AC (1999) Measurement of external three-dimensional interphalangeal loads applied during activities of daily living. Clin Biomech 14:646–652CrossRef Fowler NK, Nicol AC (1999) Measurement of external three-dimensional interphalangeal loads applied during activities of daily living. Clin Biomech 14:646–652CrossRef
14.
Zurück zum Zitat Ghanem I, Hagnere F, Dubousset J, Watier B, Skalli W, Lavaste F (1997) Intra-operative opto-electronic analysis of three dimensional vertebral displacement after CD rod rotation. Spine 12:1913–1921CrossRef Ghanem I, Hagnere F, Dubousset J, Watier B, Skalli W, Lavaste F (1997) Intra-operative opto-electronic analysis of three dimensional vertebral displacement after CD rod rotation. Spine 12:1913–1921CrossRef
15.
Zurück zum Zitat Gupta A, Rash GS, Somia NN, Wachowiak MP, Jones J, Desoky A (1998) The motion path of the digits. J Hand Surg [Am] 23:1038–1042 Gupta A, Rash GS, Somia NN, Wachowiak MP, Jones J, Desoky A (1998) The motion path of the digits. J Hand Surg [Am] 23:1038–1042
16.
Zurück zum Zitat Hahn P, Krimmer H, Hradetzky A, Lanz U (1995) Quantitative analysis of the linkage between the interphalangeal joints of the index finger. J Hand Surg [Br] 20:571–722 Hahn P, Krimmer H, Hradetzky A, Lanz U (1995) Quantitative analysis of the linkage between the interphalangeal joints of the index finger. J Hand Surg [Br] 20:571–722
17.
Zurück zum Zitat Holguin PH, Rico AA, Gomez LP, Munuera LM (1999) The coordinate movement of the interphalangeal joints. A cinematic study. Clin Orthop 362:117–124CrossRefPubMed Holguin PH, Rico AA, Gomez LP, Munuera LM (1999) The coordinate movement of the interphalangeal joints. A cinematic study. Clin Orthop 362:117–124CrossRefPubMed
18.
Zurück zum Zitat Krishnan J, Chipchase L (1997) Passive axial rotation of the metacarpophalangeal joint. J Hand Surg [Br] 22:270–273 Krishnan J, Chipchase L (1997) Passive axial rotation of the metacarpophalangeal joint. J Hand Surg [Br] 22:270–273
19.
Zurück zum Zitat Nakamura M, Miyawaki C, Matsushita N, Yagi R, Handa Y (1998) Analysis of voluntary finger movements during hand tasks by a motion analyser. J Electromyogr Kinesiol 8:295–303CrossRefPubMed Nakamura M, Miyawaki C, Matsushita N, Yagi R, Handa Y (1998) Analysis of voluntary finger movements during hand tasks by a motion analyser. J Electromyogr Kinesiol 8:295–303CrossRefPubMed
20.
Zurück zum Zitat Orset G, Lebreton E, Assouline A, Giordano P, Denis F, Pomel G (1987) L’orientation axiale des phalanges consécutive à l’enroulement des doigts. Ann Chir Main 10:101–107 Orset G, Lebreton E, Assouline A, Giordano P, Denis F, Pomel G (1987) L’orientation axiale des phalanges consécutive à l’enroulement des doigts. Ann Chir Main 10:101–107
21.
Zurück zum Zitat Rash GS, Belliappa PP, Wachochowiak MP, Somia NN, Gupta A (1999) A demonstration of the validity of a 3D video motion analysis method for measuring finger flexion and extension. J Biomech 32:1337–1341CrossRefPubMed Rash GS, Belliappa PP, Wachochowiak MP, Somia NN, Gupta A (1999) A demonstration of the validity of a 3D video motion analysis method for measuring finger flexion and extension. J Biomech 32:1337–1341CrossRefPubMed
22.
Zurück zum Zitat Runciman RJ, Bryant JT, Small CF, Fujita N, Cooke TDV (1993) Stereoradiogrammetric technique for estimating alignment of the joints in the hand and wrist. J Biomed Eng 15:99–105PubMed Runciman RJ, Bryant JT, Small CF, Fujita N, Cooke TDV (1993) Stereoradiogrammetric technique for estimating alignment of the joints in the hand and wrist. J Biomed Eng 15:99–105PubMed
23.
Zurück zum Zitat Small CF, Bryant JT (1993) Optimized 3D coordinate reconstruction from paired stereographs using a calibrated phantom. J Biomed Eng 15:163–166PubMed Small CF, Bryant JT (1993) Optimized 3D coordinate reconstruction from paired stereographs using a calibrated phantom. J Biomed Eng 15:163–166PubMed
24.
Zurück zum Zitat Small CF, Pichora DR, Bryant JT, Griffith PM (1993) Precision and accuracy of bone landmarks in characterizing hand and wrist position. J Biomed Eng 15:371–378. Erratum: (1993) Med Eng Physics 15:163–166 Small CF, Pichora DR, Bryant JT, Griffith PM (1993) Precision and accuracy of bone landmarks in characterizing hand and wrist position. J Biomed Eng 15:371–378. Erratum: (1993) Med Eng Physics 15:163–166
25.
Zurück zum Zitat Small CF, Bryant JT, Dwosh IL, Griffiths PM, Pichora DR, Zee B (1996) Validation of a three-dimensional optoelectronic motion analysis system for the hand and fingers. Clin Biomech 11:481–483CrossRef Small CF, Bryant JT, Dwosh IL, Griffiths PM, Pichora DR, Zee B (1996) Validation of a three-dimensional optoelectronic motion analysis system for the hand and fingers. Clin Biomech 11:481–483CrossRef
26.
Zurück zum Zitat Somia N, Rash GS, Wachowiak M, Gupta A (1998) The initiation and sequence of digital joint motion. J Hand Surg [Br] 23:792–795 Somia N, Rash GS, Wachowiak M, Gupta A (1998) The initiation and sequence of digital joint motion. J Hand Surg [Br] 23:792–795
27.
Zurück zum Zitat Speirs AD, Small CF, Bryant JT, Pichora DR, Zee BY (2001) Three-dimensional metacarpophalangeal joint kinematics using two markers on the phalanx. Proc Inst Mech Eng 215:415–419CrossRef Speirs AD, Small CF, Bryant JT, Pichora DR, Zee BY (2001) Three-dimensional metacarpophalangeal joint kinematics using two markers on the phalanx. Proc Inst Mech Eng 215:415–419CrossRef
28.
Zurück zum Zitat Wise S, Gardner W, Sabelman E, Valainis E, Wong Y, Glass K, Drace J, Rosen JM (1990) Evaluation of a fiber optic glove for semi-automated goniometric measurements. J Rehabil Res Dev 27:411–424PubMed Wise S, Gardner W, Sabelman E, Valainis E, Wong Y, Glass K, Drace J, Rosen JM (1990) Evaluation of a fiber optic glove for semi-automated goniometric measurements. J Rehabil Res Dev 27:411–424PubMed
29.
Zurück zum Zitat Woltring HJ, Huiskes R, De A, Lange FE (1985) Finite centroid and helical axis estimation from noisy landmark measurement in the study of human joint kinematics. J Biomech 18:379–389CrossRefPubMed Woltring HJ, Huiskes R, De A, Lange FE (1985) Finite centroid and helical axis estimation from noisy landmark measurement in the study of human joint kinematics. J Biomech 18:379–389CrossRefPubMed
Metadaten
Titel
Three-dimensional rotations of human three-joint fingers: an optoelectronic measurement. Preliminary results
verfasst von
R. Degeorges
J. Parasie
D. Mitton
N. Imbert
J.-N. Goubier
F. Lavaste
Publikationsdatum
01.03.2005
Verlag
Springer-Verlag
Erschienen in
Surgical and Radiologic Anatomy / Ausgabe 1/2005
Print ISSN: 0930-1038
Elektronische ISSN: 1279-8517
DOI
https://doi.org/10.1007/s00276-004-0277-4

Weitere Artikel der Ausgabe 1/2005

Surgical and Radiologic Anatomy 1/2005 Zur Ausgabe

Update Radiologie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.