Skip to main content
Erschienen in: Surgical and Radiologic Anatomy 3/2006

01.06.2006 | Original Article

Differences in ocular dimensions between normal and dry eyes

verfasst von: Juan A. Sanchis-Gimeno, Manuel Herrera, Franzisco Sánchez-del-Campo, Francisco Martínez-Soriano

Erschienen in: Surgical and Radiologic Anatomy | Ausgabe 3/2006

Einloggen, um Zugang zu erhalten

Abstract

Assessment of ocular dimensions is essential for ophthalmic surgeons because these values must be determined before scheduling excimer laser refractive and cataract surgeries. Dry eye seems to affect central corneal thickness (CCT) values, but it is not clear if it affects anterior chamber depth (ACD), lens thickness (LT), vitreous chamber depth (VCD) and axial length values. Following on from this, we measured the CCT, ACD, LT, VCD and axial length of 64 healthy eyes (51.20%) and 61 dry eyes (48.80%). CCT was measured with scanning-slit corneal topography (Orbscan Topography System II, Orbscan, Inc., Salt Lake City, UT, USA) and ACD, LT, VCD and axial length with a 10-MHz A-mode ultrasound device (Compuscan; Storz, St. Louis, MO, USA). There were no significant differences in ACD (P=0.588), LT (P=0.739), VCD (P=0.568) and axial length (P=0.199) between normal and dry eyes. Nevertheless, the differences in CCT between normal (549±34 μm) and dry eyes (527±30 μm) were significant (P<0.001). In sum, it seems that only the CCT values are significantly lower in subjects with dry eye.
Literatur
1.
Zurück zum Zitat Bron AM, Creuzot-Garcher C, Goudeau-Boutillon S, d’Athis P (1999) Falsely elevated intraocular pressure due to increased central corneal thickness. Graefe’s Arch Clin Exp Ophthalmol 237:220–224CrossRef Bron AM, Creuzot-Garcher C, Goudeau-Boutillon S, d’Athis P (1999) Falsely elevated intraocular pressure due to increased central corneal thickness. Graefe’s Arch Clin Exp Ophthalmol 237:220–224CrossRef
2.
Zurück zum Zitat Copt R, Thomas R, Mermoud A (1999) Corneal thickness in ocular hypertension, primary open angle glaucoma, and normal pressure glaucoma. Arch Ophthalmol 117:14–16PubMed Copt R, Thomas R, Mermoud A (1999) Corneal thickness in ocular hypertension, primary open angle glaucoma, and normal pressure glaucoma. Arch Ophthalmol 117:14–16PubMed
3.
Zurück zum Zitat Doughty MJ, Zaman ML (2000) Human corneal thickness and its impact on intraocular pressure measures: a review and meta-analysis approach. Surv Ophthalmol 44:367–408 (review) Doughty MJ, Zaman ML (2000) Human corneal thickness and its impact on intraocular pressure measures: a review and meta-analysis approach. Surv Ophthalmol 44:367–408 (review)
4.
Zurück zum Zitat Ehlers N, Bramsen T, Sperling S (1975) Applanation tonometry and central corneal thickness. Acta Ophthalmol (Copenh) 53:34–43CrossRef Ehlers N, Bramsen T, Sperling S (1975) Applanation tonometry and central corneal thickness. Acta Ophthalmol (Copenh) 53:34–43CrossRef
5.
Zurück zum Zitat Feng Y, Varikooty J, Simpson TL (2001) Diurnal variation of corneal and corneal epithelial thickness measured using optical coherence tomography. Cornea 20:480–483PubMedCrossRef Feng Y, Varikooty J, Simpson TL (2001) Diurnal variation of corneal and corneal epithelial thickness measured using optical coherence tomography. Cornea 20:480–483PubMedCrossRef
6.
Zurück zum Zitat Findl O (2005) Biometry and intraocular lens power calculation. Curr Opin Ophthalmol 16:61–64 (review) Findl O (2005) Biometry and intraocular lens power calculation. Curr Opin Ophthalmol 16:61–64 (review)
7.
Zurück zum Zitat Gordon MO, Beiser JA, Brandt JD, et al (2002) The ocular hypertension treatment study: baseline factors that predict the onset of primary open-angle glaucoma. Arch Ophthalmol 120:714–720PubMed Gordon MO, Beiser JA, Brandt JD, et al (2002) The ocular hypertension treatment study: baseline factors that predict the onset of primary open-angle glaucoma. Arch Ophthalmol 120:714–720PubMed
8.
Zurück zum Zitat Hammond MD, Madigan WP Jr, Bower KS (2005) Refractive surgery in the United States Army, 2000–2003. Ophthalmology 112:184–190PubMedCrossRef Hammond MD, Madigan WP Jr, Bower KS (2005) Refractive surgery in the United States Army, 2000–2003. Ophthalmology 112:184–190PubMedCrossRef
9.
Zurück zum Zitat Hosny MH, Alió JL, Claramonte P, Attia WH, Pérez-Santonja JJ (2000) Relationship between anterior chamber depth, refractive state, corneal diameter and axial length. J Refract Surg 16:336–340PubMed Hosny MH, Alió JL, Claramonte P, Attia WH, Pérez-Santonja JJ (2000) Relationship between anterior chamber depth, refractive state, corneal diameter and axial length. J Refract Surg 16:336–340PubMed
10.
Zurück zum Zitat Johnson M, Kass MA, Moses RA, Grodzki WJ (1978) Increased corneal thickness simulating elevated intraocular pressure. Arch Ophthalmol 96:664–665PubMed Johnson M, Kass MA, Moses RA, Grodzki WJ (1978) Increased corneal thickness simulating elevated intraocular pressure. Arch Ophthalmol 96:664–665PubMed
11.
Zurück zum Zitat Lattimore MR, Kaupp S, Schallhorn S et al (1999) Orbscan pachymetry: diurnal variation analysis. Ophthalmology 106:977–981PubMedCrossRef Lattimore MR, Kaupp S, Schallhorn S et al (1999) Orbscan pachymetry: diurnal variation analysis. Ophthalmology 106:977–981PubMedCrossRef
12.
Zurück zum Zitat Lin PY, Tsai SY, Cheng CY, Liu JH, Chou P, Hsu WM (2003) Prevalence of dry eye among an elderly Chinese population in Taiwan: the Shihpai eye study. Ophthalmology 110:1096–1101PubMedCrossRef Lin PY, Tsai SY, Cheng CY, Liu JH, Chou P, Hsu WM (2003) Prevalence of dry eye among an elderly Chinese population in Taiwan: the Shihpai eye study. Ophthalmology 110:1096–1101PubMedCrossRef
13.
14.
Zurück zum Zitat Marsich MM, Bullimore MA (2000) The repeatability of corneal thickness measures. Cornea 19:792–795PubMedCrossRef Marsich MM, Bullimore MA (2000) The repeatability of corneal thickness measures. Cornea 19:792–795PubMedCrossRef
15.
Zurück zum Zitat Mills RP (2000) If intraocular pressure measurement is only an estimate-then what? Ophthalmology 107:1807–1808 (guest editorials) Mills RP (2000) If intraocular pressure measurement is only an estimate-then what? Ophthalmology 107:1807–1808 (guest editorials)
16.
Zurück zum Zitat Moss SE, Klein R, Klein BE (2004) Incidence of dry eye in an older population. Arch Ophthalmol 122:369–373PubMedCrossRef Moss SE, Klein R, Klein BE (2004) Incidence of dry eye in an older population. Arch Ophthalmol 122:369–373PubMedCrossRef
17.
Zurück zum Zitat Ozkagnici A, Buyukmumcu M, Zengin N, Gunduz K, Koc H (2001) Ocular and periorbital anthropometric measurements in term Turkish newborns. Surg Radiol Anat 23:321–324PubMedCrossRef Ozkagnici A, Buyukmumcu M, Zengin N, Gunduz K, Koc H (2001) Ocular and periorbital anthropometric measurements in term Turkish newborns. Surg Radiol Anat 23:321–324PubMedCrossRef
18.
Zurück zum Zitat Price FW, Koller DL, Price MO (1999) Central corneal pachymetry in patients undergoing laser in situ keratomileusis. Ophthalmology 106:2216–2220PubMedCrossRef Price FW, Koller DL, Price MO (1999) Central corneal pachymetry in patients undergoing laser in situ keratomileusis. Ophthalmology 106:2216–2220PubMedCrossRef
19.
Zurück zum Zitat Sanchis-Gimeno JA, Lleo-Perez A, Alonso L, Rahhal MS, Martinez-Soriano F (2005) Reduced corneal thickness values in postmenopausal women with dry eye. Cornea 24:39–44PubMedCrossRef Sanchis-Gimeno JA, Lleo-Perez A, Alonso L, Rahhal MS, Martinez-Soriano F (2005) Reduced corneal thickness values in postmenopausal women with dry eye. Cornea 24:39–44PubMedCrossRef
20.
Zurück zum Zitat Shah S, Spedding C, Bhojwani R et al (2000) Assessment of the diurnal variation in central corneal thickness and intraocular pressure for patients with suspected glaucoma. Ophthalmology 107:1191–1193PubMedCrossRef Shah S, Spedding C, Bhojwani R et al (2000) Assessment of the diurnal variation in central corneal thickness and intraocular pressure for patients with suspected glaucoma. Ophthalmology 107:1191–1193PubMedCrossRef
21.
Zurück zum Zitat Shufelt C, Fraser-Bell S, Ying-Lai M, Torres M, Varma R (2005) Refractive error, ocular biometry, and lens opalescence in an adult population: the los angeles latino eye study. Invest Ophthalmol Vis Sci 46:4450–4460PubMedCrossRef Shufelt C, Fraser-Bell S, Ying-Lai M, Torres M, Varma R (2005) Refractive error, ocular biometry, and lens opalescence in an adult population: the los angeles latino eye study. Invest Ophthalmol Vis Sci 46:4450–4460PubMedCrossRef
22.
Zurück zum Zitat Singh RS, Goldberg I, Graham SL, Sharma A, Mohsin M (2001) Central corneal thickness, tonometry, and ocular dimensions in glaucoma and ocular hypertension. J Glaucoma 10:206–210PubMedCrossRef Singh RS, Goldberg I, Graham SL, Sharma A, Mohsin M (2001) Central corneal thickness, tonometry, and ocular dimensions in glaucoma and ocular hypertension. J Glaucoma 10:206–210PubMedCrossRef
23.
Zurück zum Zitat Suzuki S, Oshika T, Oki K et al (2003) Corneal thickness measurements: scanning-slit corneal topography and noncontact specular microscopy versus ultrasonic pachymetry. J Cataract Refract Surg 29:1313–1318PubMedCrossRef Suzuki S, Oshika T, Oki K et al (2003) Corneal thickness measurements: scanning-slit corneal topography and noncontact specular microscopy versus ultrasonic pachymetry. J Cataract Refract Surg 29:1313–1318PubMedCrossRef
24.
Zurück zum Zitat Yaylali V, Kaufman SC, Thompson HW (1997) Corneal thickness measurements with the orbscan topography system and ultrasonic pachymetry. J Cataract Refract Surg 23:1345–1350PubMed Yaylali V, Kaufman SC, Thompson HW (1997) Corneal thickness measurements with the orbscan topography system and ultrasonic pachymetry. J Cataract Refract Surg 23:1345–1350PubMed
Metadaten
Titel
Differences in ocular dimensions between normal and dry eyes
verfasst von
Juan A. Sanchis-Gimeno
Manuel Herrera
Franzisco Sánchez-del-Campo
Francisco Martínez-Soriano
Publikationsdatum
01.06.2006
Verlag
Springer-Verlag
Erschienen in
Surgical and Radiologic Anatomy / Ausgabe 3/2006
Print ISSN: 0930-1038
Elektronische ISSN: 1279-8517
DOI
https://doi.org/10.1007/s00276-006-0076-1

Weitere Artikel der Ausgabe 3/2006

Surgical and Radiologic Anatomy 3/2006 Zur Ausgabe

Update Radiologie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.