Skip to main content
Erschienen in: Surgical and Radiologic Anatomy 3/2007

01.04.2007 | Original Article

Morphometric parameters of the radial head: an anatomical study

verfasst von: T. C. Koslowsky, I. Germund, F. Beyer, K. Mader, C. F. Krieglstein, J. Koebke

Erschienen in: Surgical and Radiologic Anatomy | Ausgabe 3/2007

Einloggen, um Zugang zu erhalten

Abstract

Introduction

Exact anatomical description of the proximal radius is imperative for the development of radial head prostheses. The purpose of this study was to measure the anatomical parameters of the radial head.

Methods

Optosil imprints of 18 pairs of proximal radii fixed with formalin were taken. All possessed their native cartilage joint surface free of any arthritic defects. After being cut into 3 mm slices, the diameter of each slice was measured in steps of 30° of rotation with the margo interosseous acting as a reference point.

Results

Maximum radial head diameter was seen from the 0 to the 9 mm slice at a rotation of 30° to full supination perpendicular to the proximal radioulnar joint. The diameter increased from the radiocapitular joint surface to the 6 mm slice, and then it decreased (P < 0.001). At the level of 6 mm the maximum radial head diameter was 24.13 mm (range 21.2–27.3 mm). The minimum diameter was seen perpendicular to the maximum; it also increased from the radiocapitular joint surface to the 6 mm slice and then decreased. There was a significant difference between the minimum and maximum diameter of each slice at a P-level of P < 0.001. Left and right sides were not significantly different at a P-level of 0.01.

Conclusion

Our data show that the radial head is neither round nor conical. It has a complex shape with an increasing size from the radiocapitular joint surface to the middle of the proximal radioulnar joint surface. No statistically significant differences could be observed between right and left radii.
Literatur
1.
Zurück zum Zitat Alcaniz M, Montserrat C, Grau V, Chinesta F, Ramon A, Albalat S (1998) An advanced system for the simulation and planning of orthodontic treatment. Med Image Anal 2(1):61–77PubMedCrossRef Alcaniz M, Montserrat C, Grau V, Chinesta F, Ramon A, Albalat S (1998) An advanced system for the simulation and planning of orthodontic treatment. Med Image Anal 2(1):61–77PubMedCrossRef
2.
Zurück zum Zitat Beredjiklian PK, Nalbantoglu U, Potter H, Hotchkiss RN (1998) Prosthetic radial head components and proximal radial morphology: a mismatch. J Shoulder Elbow Surg 8:471–475CrossRef Beredjiklian PK, Nalbantoglu U, Potter H, Hotchkiss RN (1998) Prosthetic radial head components and proximal radial morphology: a mismatch. J Shoulder Elbow Surg 8:471–475CrossRef
3.
Zurück zum Zitat Captier G, Canovas F, Mercier N, Thomas E, Bonnel F (2002) Biometry of the radial head: biomechanical implications in pronation and supination. Surg Radiol Anat 24(5):295–301PubMedCrossRef Captier G, Canovas F, Mercier N, Thomas E, Bonnel F (2002) Biometry of the radial head: biomechanical implications in pronation and supination. Surg Radiol Anat 24(5):295–301PubMedCrossRef
4.
Zurück zum Zitat Carn RM, Medige J, Curtain D, Koenig A (1986) Silicone rubber replacement of the severely fractured radial head. Clin Orthop 209:259–269PubMed Carn RM, Medige J, Curtain D, Koenig A (1986) Silicone rubber replacement of the severely fractured radial head. Clin Orthop 209:259–269PubMed
5.
Zurück zum Zitat Carr CR, Howard JW (1951) Metallic cap replacement of radial head following fracture. West J Surg Obstet Gynecol 59:539–546PubMed Carr CR, Howard JW (1951) Metallic cap replacement of radial head following fracture. West J Surg Obstet Gynecol 59:539–546PubMed
6.
Zurück zum Zitat Cherry JC (1953) Use of acrylic prosthesis in treatment of fracture of the head of the radius. J Bone Joint Surg 35-B:70–71 Cherry JC (1953) Use of acrylic prosthesis in treatment of fracture of the head of the radius. J Bone Joint Surg 35-B:70–71
7.
Zurück zum Zitat Gupta GG, Moore-Jansen PH, Lucas GL (1992) Differences in radial head dimensions based on gender, race, age and side. Orthop Trans 16:342 Gupta GG, Moore-Jansen PH, Lucas GL (1992) Differences in radial head dimensions based on gender, race, age and side. Orthop Trans 16:342
8.
Zurück zum Zitat Herbertsson P, Josefsson PO, Hasserius R, Besjakov J, Nyqvist F, Karlsson MK (2004) Fractures of the radial head treated with radial head excision. J Bone Joint Surg 86-A(9):1925–1930PubMed Herbertsson P, Josefsson PO, Hasserius R, Besjakov J, Nyqvist F, Karlsson MK (2004) Fractures of the radial head treated with radial head excision. J Bone Joint Surg 86-A(9):1925–1930PubMed
9.
Zurück zum Zitat Ikeda M, Sugiyama K, Kang C, Takagaki T, Oka Y (2005) Comminuted fractures of the radial head. Comparison of resection and internal fixation. J Bone Joint Surg 87-A:76–84CrossRef Ikeda M, Sugiyama K, Kang C, Takagaki T, Oka Y (2005) Comminuted fractures of the radial head. Comparison of resection and internal fixation. J Bone Joint Surg 87-A:76–84CrossRef
10.
Zurück zum Zitat Ikeda M, Yamashina Y, Kamimoto M, Oka Y (2003) Open reduction and internal fixation of comminuted fractures of the radial head using low-profile mini-plates. J Bone Joint Surg 84-B:1040–1044CrossRef Ikeda M, Yamashina Y, Kamimoto M, Oka Y (2003) Open reduction and internal fixation of comminuted fractures of the radial head using low-profile mini-plates. J Bone Joint Surg 84-B:1040–1044CrossRef
11.
Zurück zum Zitat King GJ, Zarzour ZD, Patterson SD, Johnson JA (2001) An anthropometric study of the radial head: implications in the design of a prosthesis. J Arthroplasty 16(1):112–116PubMedCrossRef King GJ, Zarzour ZD, Patterson SD, Johnson JA (2001) An anthropometric study of the radial head: implications in the design of a prosthesis. J Arthroplasty 16(1):112–116PubMedCrossRef
12.
Zurück zum Zitat König S, Goldammer A, Vitzthum HE (2005) Anatomical data on the craniocervical junction and its correlation with degenerative changes in 30 cadaveric specimens. J Neurosurg Spine 3:379–385PubMedCrossRef König S, Goldammer A, Vitzthum HE (2005) Anatomical data on the craniocervical junction and its correlation with degenerative changes in 30 cadaveric specimens. J Neurosurg Spine 3:379–385PubMedCrossRef
13.
Zurück zum Zitat Mahaisavariya B, Saekee B, Sitthiseripratip K, Oris P, Tongdee T, Bohez EL, Vander Sloten J (2004) Morphology of the radial head: a reverse engineering based evaluation using three-dimensional anatomical data of radial bone. Proc Inst Mech Eng (H) 218(1):79–84 Mahaisavariya B, Saekee B, Sitthiseripratip K, Oris P, Tongdee T, Bohez EL, Vander Sloten J (2004) Morphology of the radial head: a reverse engineering based evaluation using three-dimensional anatomical data of radial bone. Proc Inst Mech Eng (H) 218(1):79–84
14.
Zurück zum Zitat Murai Lau HK, Pereira BP, Pho RW (1997) A cadaveric study on volume and surface area of the fingertip. J Hand Surg 22(5):935–941CrossRef Murai Lau HK, Pereira BP, Pho RW (1997) A cadaveric study on volume and surface area of the fingertip. J Hand Surg 22(5):935–941CrossRef
15.
Zurück zum Zitat Popovic N, Djekic Jire R, Lemaire R, Gellet P (2005) A comparative study between proximal radial morphology and the floating radial head prosthesis. J Shoulder Elbow Surg 14/4:433–440CrossRef Popovic N, Djekic Jire R, Lemaire R, Gellet P (2005) A comparative study between proximal radial morphology and the floating radial head prosthesis. J Shoulder Elbow Surg 14/4:433–440CrossRef
16.
Zurück zum Zitat Ring D, Quintero J, Jupiter JB (2002) Open reduction and internal fixation of the fractures of the radial head. J Bone Joint Surg (Am) 84-A:1811–1815 Ring D, Quintero J, Jupiter JB (2002) Open reduction and internal fixation of the fractures of the radial head. J Bone Joint Surg (Am) 84-A:1811–1815
17.
Zurück zum Zitat Roidis N, Stevanovic M, Martirosian A, Abbott DD, McPherson EJ, Itamura JM (2003) A radiographic study of proximal radius anatomy with implications in radial head replacement. J Shoulder Elbow Surg 12(4):380–384PubMedCrossRef Roidis N, Stevanovic M, Martirosian A, Abbott DD, McPherson EJ, Itamura JM (2003) A radiographic study of proximal radius anatomy with implications in radial head replacement. J Shoulder Elbow Surg 12(4):380–384PubMedCrossRef
18.
Zurück zum Zitat Sanchez-Sotelo J, Romanillos O, Garay EG (2000) Results of acute excision of the radial head in elbow radial head fracture-dislocation. J Orthop Trauma 14(5):354–358PubMedCrossRef Sanchez-Sotelo J, Romanillos O, Garay EG (2000) Results of acute excision of the radial head in elbow radial head fracture-dislocation. J Orthop Trauma 14(5):354–358PubMedCrossRef
19.
Zurück zum Zitat Sarnat BG (1980) Orbital volume in young and adult rabbits. Anat Embryol (Berl) 159(2):211–221CrossRef Sarnat BG (1980) Orbital volume in young and adult rabbits. Anat Embryol (Berl) 159(2):211–221CrossRef
20.
Zurück zum Zitat Skalski K, Swieszkowski W, Pomianowski St, Kedzior K, Kowalik St (2004) Radial head prosthesis with a mobile head. J Shoulder Elbow Surg 13/1:78–85CrossRef Skalski K, Swieszkowski W, Pomianowski St, Kedzior K, Kowalik St (2004) Radial head prosthesis with a mobile head. J Shoulder Elbow Surg 13/1:78–85CrossRef
21.
Zurück zum Zitat Spector MR, Donovan TE, Nicholls (1990) An evaluation of impression techniques for osseointegrated implants. J Prosthet Dent 63:444–447PubMedCrossRef Spector MR, Donovan TE, Nicholls (1990) An evaluation of impression techniques for osseointegrated implants. J Prosthet Dent 63:444–447PubMedCrossRef
22.
Zurück zum Zitat Speed K (1941) Ferrule caps for the head of the radius Surg. Gynecol Obstet 73: 845–850 Speed K (1941) Ferrule caps for the head of the radius Surg. Gynecol Obstet 73: 845–850
23.
Zurück zum Zitat Swieszkowski W, Skalski K, Pomianowski S, Kedzior K (2001) The anatomic features of the radial head and their implication for prosthesis design. Clin Biomech (Bristol, Avon) 16(10):880–887CrossRef Swieszkowski W, Skalski K, Pomianowski S, Kedzior K (2001) The anatomic features of the radial head and their implication for prosthesis design. Clin Biomech (Bristol, Avon) 16(10):880–887CrossRef
24.
Zurück zum Zitat Toksvig-Larsen S, Kroon PO, Ryd L (1994) Improved bone cutting using a semi-rotating saw. A cadaver study of the cut surface on tibial condyles. Acta Orthop Scand 65(4):412–414PubMedCrossRef Toksvig-Larsen S, Kroon PO, Ryd L (1994) Improved bone cutting using a semi-rotating saw. A cadaver study of the cut surface on tibial condyles. Acta Orthop Scand 65(4):412–414PubMedCrossRef
25.
Zurück zum Zitat Van Glabbeck F, Van Riet R, Verstreken J (2001) Current concepts in the treatment of radial head fractures in adults: a clinical and biomechanical approach. Acta Orthopedica Belgica 67-5:430–441 Van Glabbeck F, Van Riet R, Verstreken J (2001) Current concepts in the treatment of radial head fractures in adults: a clinical and biomechanical approach. Acta Orthopedica Belgica 67-5:430–441
26.
Zurück zum Zitat van Riet RP, Van Glabbeek F, Baumfeld JA, Neale PG, Morrey BF, O’Driscoll SW, An KN (2004) The effect of the orientation of the non-circular radial head on elbow kinematics. Clin Biomech 19:595–599CrossRef van Riet RP, Van Glabbeek F, Baumfeld JA, Neale PG, Morrey BF, O’Driscoll SW, An KN (2004) The effect of the orientation of the non-circular radial head on elbow kinematics. Clin Biomech 19:595–599CrossRef
27.
Zurück zum Zitat van Riet RP, Van Glabbeek F, Neale PG, Bortier H, An KN, O’Driscoll SW (2003) The non-circular shape of the radial head. J Hand Surg (Am) 28(6):972–978CrossRef van Riet RP, Van Glabbeek F, Neale PG, Bortier H, An KN, O’Driscoll SW (2003) The non-circular shape of the radial head. J Hand Surg (Am) 28(6):972–978CrossRef
28.
Zurück zum Zitat Weiss A-PC, Hastings H II (1992) The anatomy of the proximal radioulnar joint. J Shoulder Elbow Surg 1:193–199CrossRef Weiss A-PC, Hastings H II (1992) The anatomy of the proximal radioulnar joint. J Shoulder Elbow Surg 1:193–199CrossRef
Metadaten
Titel
Morphometric parameters of the radial head: an anatomical study
verfasst von
T. C. Koslowsky
I. Germund
F. Beyer
K. Mader
C. F. Krieglstein
J. Koebke
Publikationsdatum
01.04.2007
Verlag
Springer-Verlag
Erschienen in
Surgical and Radiologic Anatomy / Ausgabe 3/2007
Print ISSN: 0930-1038
Elektronische ISSN: 1279-8517
DOI
https://doi.org/10.1007/s00276-007-0197-1

Weitere Artikel der Ausgabe 3/2007

Surgical and Radiologic Anatomy 3/2007 Zur Ausgabe

Update Radiologie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.