The aim of this study was to assess the in vivo measurement precision of a software tool for volumetric analysis of pulmonary nodules from two consecutive low-dose multi-row detector CT scans. A total of 151 pulmonary nodules (diameter 2.2–20.5 mm, mean diameter 7.4±4.5 mm) in ten subjects with pulmonary metastases were examined with low-dose four-detector-row CT (120 kVp, 20 mAs (effective), collimation 4×1 mm, normalized pitch 1.75, slice thickness 1.25 mm, reconstruction increment 0.8 mm; Somatom VolumeZoom, Siemens). Two consecutive low-dose scans covering the whole lung were performed within 10 min. Nodule volume was determined for all pulmonary nodules visually detected in both scans using the volumetry tool included in the Siemens LungCare software. The 95% limits of agreement between nodule volume measurements on different scans were calculated using the Bland and Altman method for assessing measurement agreement. Intra- and interobserver agreement of volume measurement were determined using repetitive measurements of 50 randomly selected nodules at the same scan by the same and different observers. Taking into account all 151 nodules, 95% limits of agreement were −20.4 to 21.9% (standard error 1.5%); they were −19.3 to 20.4% (standard error 1.7%) for 105 nodules <10 mm. Limits of agreement were −3.9 to 5.7% for intraobserver and −5.5 to 6.6% for interobserver agreement. Precision of in vivo volumetric analysis of nodules with an automatic volumetry software tool was sufficiently high to allow for detection of clinically relevant growth in small pulmonary nodules.
Literatur
1.
Zurück zum Zitat Fischbach F, Knollmann F, Griesshaber V et al. (2003) Detection of pulmonary nodules by multislice computed tomography: improved detection rate with reduced slice thickness. Eur Radiol 13:2378-2383PubMed Fischbach F, Knollmann F, Griesshaber V et al. (2003) Detection of pulmonary nodules by multislice computed tomography: improved detection rate with reduced slice thickness. Eur Radiol 13:2378-2383PubMed
2.
Zurück zum Zitat Sone S, Takashima S, Li F et al. (1998) Mass screening for lung cancer with mobile spiral computed tomography scanner. Lancet 351:1242–1245PubMed Sone S, Takashima S, Li F et al. (1998) Mass screening for lung cancer with mobile spiral computed tomography scanner. Lancet 351:1242–1245PubMed
3.
Zurück zum Zitat Kaneko M, Eguchi K, Ohmatsu H et al. (1996) Peripheral lung cancer: screening and detection with low-dose spiral-CT versus radiography. Radiology 201:798–802PubMed Kaneko M, Eguchi K, Ohmatsu H et al. (1996) Peripheral lung cancer: screening and detection with low-dose spiral-CT versus radiography. Radiology 201:798–802PubMed
4.
Zurück zum Zitat Henschke CI, McCauley DI, Yankelevitz DF et al. (1999) Early lung cancer action project: overall design and findings from baseline screening. Lancet 354:99–105PubMed Henschke CI, McCauley DI, Yankelevitz DF et al. (1999) Early lung cancer action project: overall design and findings from baseline screening. Lancet 354:99–105PubMed
5.
Zurück zum Zitat Diederich S, Wormanns D, Semik M et al. (2002) Screening for early lung cancer with low-dose spiral CT: prevalence in 817 asymptomatic smokers. Radiology 222:773–781PubMed Diederich S, Wormanns D, Semik M et al. (2002) Screening for early lung cancer with low-dose spiral CT: prevalence in 817 asymptomatic smokers. Radiology 222:773–781PubMed
6.
Zurück zum Zitat Swensen SJ, Jett JR, Sloan JA et al. (2002) Screening for lung cancer with low-dose spiral computed tomography. Am J Respir Crit Care Med 165:508–513PubMed Swensen SJ, Jett JR, Sloan JA et al. (2002) Screening for lung cancer with low-dose spiral computed tomography. Am J Respir Crit Care Med 165:508–513PubMed
7.
Zurück zum Zitat Schoepf UJ, Becker CR, Obuchowski NA et al. (2001) Multi-slice computed tomography as a screening tool for colon cancer, lung cancer and coronary heart disease. Eur Radiol 11:1975–1985CrossRefPubMed Schoepf UJ, Becker CR, Obuchowski NA et al. (2001) Multi-slice computed tomography as a screening tool for colon cancer, lung cancer and coronary heart disease. Eur Radiol 11:1975–1985CrossRefPubMed
8.
Zurück zum Zitat Munden RF, Pugatch RD, Liptay MJ, Sugarbaker DJ, Le LU (1997) Small pulmonary lesions detected at CT: clinical importance. Radiology 202:105–110PubMed Munden RF, Pugatch RD, Liptay MJ, Sugarbaker DJ, Le LU (1997) Small pulmonary lesions detected at CT: clinical importance. Radiology 202:105–110PubMed
9.
Zurück zum Zitat Yankelevitz DF, Reeves AP, Kostis WJ, Zhao B, Henschke CI (2000) Small pulmonary nodules: volumetrically determined growth rates based on CT evaluation. Radiology 217:251–256PubMed Yankelevitz DF, Reeves AP, Kostis WJ, Zhao B, Henschke CI (2000) Small pulmonary nodules: volumetrically determined growth rates based on CT evaluation. Radiology 217:251–256PubMed
10.
Zurück zum Zitat Yankelevitz DF, Gupta R, Zhao B, Henschke CI (1999) Small pulmonary nodules: evaluation with repeat CT—preliminary experience. Radiology 212:561–566PubMed Yankelevitz DF, Gupta R, Zhao B, Henschke CI (1999) Small pulmonary nodules: evaluation with repeat CT—preliminary experience. Radiology 212:561–566PubMed
11.
Zurück zum Zitat Winer-Muram HT, Jennings SG, Tarver RD et al. (2002) Volumetric growth rate of stage I lung cancer prior to treatment: serial CT scanning. Radiology 223:798–805PubMed Winer-Muram HT, Jennings SG, Tarver RD et al. (2002) Volumetric growth rate of stage I lung cancer prior to treatment: serial CT scanning. Radiology 223:798–805PubMed
12.
Zurück zum Zitat Wormanns D, Diederich S, Lentschig MG, Winter F, Heindel W (2000) Spiral CT of pulmonary nodules: interobserver variation in assessment of lesion size. Eur Radiol 10:710–713CrossRefPubMed Wormanns D, Diederich S, Lentschig MG, Winter F, Heindel W (2000) Spiral CT of pulmonary nodules: interobserver variation in assessment of lesion size. Eur Radiol 10:710–713CrossRefPubMed
13.
Zurück zum Zitat Udupa JK, LeBlanc VR, Schmidt H et al. (2002) A methodology for evaluating image segmentation algorithms. In: Sonka M, Fitzpatrick JM (eds) Medical Imaging 2002: Image processing. Proc SPIE 4684:266–277 Udupa JK, LeBlanc VR, Schmidt H et al. (2002) A methodology for evaluating image segmentation algorithms. In: Sonka M, Fitzpatrick JM (eds) Medical Imaging 2002: Image processing. Proc SPIE 4684:266–277
14.
Zurück zum Zitat Fan L, Qian J, Odry BL et al. (2002) Automatic segmentation of pulmonary nodules by using dynamic 3D cross-correlation for interactive CAD systems. In: Sonka M, Fitzpatrick JM (eds) Medical Imaging 2002: Image processing. Proc SPIE 4684:1362–1369 Fan L, Qian J, Odry BL et al. (2002) Automatic segmentation of pulmonary nodules by using dynamic 3D cross-correlation for interactive CAD systems. In: Sonka M, Fitzpatrick JM (eds) Medical Imaging 2002: Image processing. Proc SPIE 4684:1362–1369
15.
Zurück zum Zitat Bland JM, Altman DG (1986) Statistical methods for assessing agreement between two methods of clinical measurement. Lancet 1 (8476):307–310PubMed Bland JM, Altman DG (1986) Statistical methods for assessing agreement between two methods of clinical measurement. Lancet 1 (8476):307–310PubMed
16.
Zurück zum Zitat Wormanns D, Kohl G, Klotz E, Heindel W, Diederich S (2002) Clinical evaluation of the reproducibility of volume measurements of pulmonary nodules. In: Sonka M, Fitzpatrick JM (eds) Medical Imaging 2002: Image processing. Proc SPIE 4684:316–322 Wormanns D, Kohl G, Klotz E, Heindel W, Diederich S (2002) Clinical evaluation of the reproducibility of volume measurements of pulmonary nodules. In: Sonka M, Fitzpatrick JM (eds) Medical Imaging 2002: Image processing. Proc SPIE 4684:316–322
17.
Zurück zum Zitat Kohl G, Schaller S, Klotz E et al. (2002) Segmentation of pulmonary nodules: influence of scanning and reconstruction parameters on reproducibility of volume measurements (abstracts). Medical Imaging 2002: Image processing. Proc SPIE 4684 Kohl G, Schaller S, Klotz E et al. (2002) Segmentation of pulmonary nodules: influence of scanning and reconstruction parameters on reproducibility of volume measurements (abstracts). Medical Imaging 2002: Image processing. Proc SPIE 4684
18.
Zurück zum Zitat Hasegawa M, Sone S, Takashima S et al. (2000) Growth rate of small lung cancers detected on mass CT screening. Br J Radiol 73:1252–1259PubMed Hasegawa M, Sone S, Takashima S et al. (2000) Growth rate of small lung cancers detected on mass CT screening. Br J Radiol 73:1252–1259PubMed
19.
Zurück zum Zitat Yankelevitz DF, Henschke CI (1997) Does 2-year stability imply that pulmonary nodules are benign? AJR 168:325–328 Yankelevitz DF, Henschke CI (1997) Does 2-year stability imply that pulmonary nodules are benign? AJR 168:325–328
20.
Zurück zum Zitat Aoki T, Nakata H, Watanabe H et al. (2000) Evolution of peripheral lung adenocarcinomas: CT findings correlated with histology and tumor doubling time. AJR 174:763–768 Aoki T, Nakata H, Watanabe H et al. (2000) Evolution of peripheral lung adenocarcinomas: CT findings correlated with histology and tumor doubling time. AJR 174:763–768
21.
Zurück zum Zitat Steele JD, Buell P (1973) Asymptomatic solitary pulmonary nodules: host survival, tumor size, and growth rate. J Thorac Cardiovasc Surg 65:140–151PubMed Steele JD, Buell P (1973) Asymptomatic solitary pulmonary nodules: host survival, tumor size, and growth rate. J Thorac Cardiovasc Surg 65:140–151PubMed
22.
Zurück zum Zitat Weiss W (1971) Peripheral measurable bronchogenic carcinoma: growth rate and period of risk after therapy. Am Rev Resp Dis 103:198–208 Weiss W (1971) Peripheral measurable bronchogenic carcinoma: growth rate and period of risk after therapy. Am Rev Resp Dis 103:198–208
23.
Zurück zum Zitat Henschke CI, Yankelevitz DF, Mirtcheva R, McGuinness G, McCauley D, Miettinen OS (2002) CT screening for lung cancer: frequency and significance of part-solid and nonsolid nodules. Am J Roentgenol. 178:1053–1057 Henschke CI, Yankelevitz DF, Mirtcheva R, McGuinness G, McCauley D, Miettinen OS (2002) CT screening for lung cancer: frequency and significance of part-solid and nonsolid nodules. Am J Roentgenol. 178:1053–1057
Metadaten
Titel
Volumetric measurements of pulmonary nodules at multi-row detector CT: in vivo reproducibility
verfasst von
Dag Wormanns
Gerhard Kohl
Ernst Klotz
Anke Marheine
Florian Beyer
Walter Heindel
Stefan Diederich
Publikationsdatum
01.01.2004
Verlag
Springer-Verlag
Erschienen in
European Radiology / Ausgabe 1/2004
Print ISSN: 0938-7994
Elektronische ISSN: 1432-1084
DOI
https://doi.org/10.1007/s00330-003-2132-0

Weitere Artikel der Ausgabe 1/2004

European Radiology 1/2004 Zur Ausgabe

Acknowledgement to reviewers

Acknowledgement to reviewers 2003

Update Radiologie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.