Skip to main content
Erschienen in: European Radiology 6/2004

01.06.2004 | Gastrointestinal

CT colonography: effect of experience and training on reader performance

verfasst von: Stuart A. Taylor, Steve Halligan, David Burling, Simon Morley, Paul Bassett, Wendy Atkin, Clive I. Bartram

Erschienen in: European Radiology | Ausgabe 6/2004

Einloggen, um Zugang zu erhalten

Abstract

The purpose of this paper was to investigate the effect of radiologist experience and increasing exposure to CT colonography on reader performance. Three radiologists of differing general experience (consultant, research fellow, trainee) independently analysed 100 CT colonographic datasets. Readers had no prior experience of CT colonography and received feedback and training after the first 50 cases from an independent experienced radiologist. Diagnostic performance and reporting times were compared for the first and second 50 datasets and compared with the results of a radiologist experienced in CT colonography. Before training only the consultant reader achieved statistical equivalence with the reference standard for detection of larger polyps. After training, detection rates ranged between 25 and 58% for larger polyps. Only the trainee significantly improved after training (P=0.007), with performance of other readers unchanged or even worse. Reporting times following training were reduced significantly for the consultant and fellow (P<0.001 and P=0.03, respectively), but increased for the trainee (P<0.001). In comparison to the consultant reader, the odds of detection of larger polyps was 0.36 (CI 0.16, 0.82) for the fellow and 0.36 (CI 0.14, 0.91) for the trainee. There is considerable variation in the ability to report CT colonography. Prior experience in gastrointestinal radiology is a distinct advantage. Competence cannot be assumed even after directed training via a database of 50 cases.
Literatur
1.
Zurück zum Zitat Yee J, Akerkar GA, Hung RK, Steinauer-Gebauer AM, Wall SD, McQuaid KR (2001) Colorectal neoplasia: performance characteristics of CT colonography for detection in 300 patients. Radiology 219:685–692PubMed Yee J, Akerkar GA, Hung RK, Steinauer-Gebauer AM, Wall SD, McQuaid KR (2001) Colorectal neoplasia: performance characteristics of CT colonography for detection in 300 patients. Radiology 219:685–692PubMed
2.
Zurück zum Zitat Fenlon HM, Nunes DP, Schroy PC III, Barish MA, Clarke PD, Ferrucci JT (1999) A comparison of virtual and conventional colonoscopy for the detection of colorectal polyps. N Engl J Med 341:1496–1503PubMed Fenlon HM, Nunes DP, Schroy PC III, Barish MA, Clarke PD, Ferrucci JT (1999) A comparison of virtual and conventional colonoscopy for the detection of colorectal polyps. N Engl J Med 341:1496–1503PubMed
3.
Zurück zum Zitat Macari M, Bini EJ, Xue X, Milano A, Katz SS, Resnick D, Chandarana H, Krinsky G, Klingenbeck K, Marshall CH, Megibow AJ (2002) Colorectal neoplasms: prospective comparison of thin-section low-dose multi-detector row CT colonography and conventional colonoscopy for detection. Radiology 224:383–392PubMed Macari M, Bini EJ, Xue X, Milano A, Katz SS, Resnick D, Chandarana H, Krinsky G, Klingenbeck K, Marshall CH, Megibow AJ (2002) Colorectal neoplasms: prospective comparison of thin-section low-dose multi-detector row CT colonography and conventional colonoscopy for detection. Radiology 224:383–392PubMed
4.
Zurück zum Zitat Dachman AH (2002) Diagnostic performance of virtual colonoscopy. Abdom Imaging 27:260–267PubMed Dachman AH (2002) Diagnostic performance of virtual colonoscopy. Abdom Imaging 27:260–267PubMed
5.
Zurück zum Zitat Rex DK, Vining D, Kopecky KK (1999) An initial experience with screening for colon polyps using spiral CT with and without CT colonography (virtual colonoscopy). Gastrointest Endosc 50:309–313PubMed Rex DK, Vining D, Kopecky KK (1999) An initial experience with screening for colon polyps using spiral CT with and without CT colonography (virtual colonoscopy). Gastrointest Endosc 50:309–313PubMed
6.
Zurück zum Zitat Yee J, Kumar NN, Hung RK, Akerkar GA, Kumar PR, Wall SD (2003) Comparison of supine and prone scanning separately and in combination at CT colonography. Radiology 226:653–661PubMed Yee J, Kumar NN, Hung RK, Akerkar GA, Kumar PR, Wall SD (2003) Comparison of supine and prone scanning separately and in combination at CT colonography. Radiology 226:653–661PubMed
7.
Zurück zum Zitat Nodine CF, Kundel HL, Mello-Thoms C, Weinstein SP, Orel SG, Sullivan DC, Conant EF (1999) How experience and training influence mammography expertise. Acad Radiol 6:575–585PubMed Nodine CF, Kundel HL, Mello-Thoms C, Weinstein SP, Orel SG, Sullivan DC, Conant EF (1999) How experience and training influence mammography expertise. Acad Radiol 6:575–585PubMed
8.
Zurück zum Zitat Halligan S, Marshall MM, Taylor SA, Bartram CI, Atkin W (2003) Observer variation in detection of colorectal neoplasia on double-contrast barium enema: implications for colorectal cancer screening and training. Clin Radiol 58:948–954CrossRefPubMed Halligan S, Marshall MM, Taylor SA, Bartram CI, Atkin W (2003) Observer variation in detection of colorectal neoplasia on double-contrast barium enema: implications for colorectal cancer screening and training. Clin Radiol 58:948–954CrossRefPubMed
9.
Zurück zum Zitat Gluecker T, Meuwly JY, Pescatore P, Schnyder P, Delarive J, Jornod P, Meuli R, Dorta G (2002) Effect of investigator experience in CT colonography. Eur Radiol 12:1405–1409CrossRefPubMed Gluecker T, Meuwly JY, Pescatore P, Schnyder P, Delarive J, Jornod P, Meuli R, Dorta G (2002) Effect of investigator experience in CT colonography. Eur Radiol 12:1405–1409CrossRefPubMed
10.
Zurück zum Zitat Pescatore P, Glucker T, Delarive J, Meuli R, Pantoflickova D, Duvoisin B, Schnuder P, Blum AL, Dorta G (2000) Diagnostic accuracy and interobserver agreement of CT colonography (virtual colonoscopy). Gut 47:126–130CrossRefPubMed Pescatore P, Glucker T, Delarive J, Meuli R, Pantoflickova D, Duvoisin B, Schnuder P, Blum AL, Dorta G (2000) Diagnostic accuracy and interobserver agreement of CT colonography (virtual colonoscopy). Gut 47:126–130CrossRefPubMed
11.
Zurück zum Zitat McFarland EG, Pilgram TK, Brink JA, McDermott RA, Santillan CV, Brady PW, Heiken JP, Balfe DM, Weinstock LB, Thyssen EP, Littenberg (2002) CT colonography: multiobserver diagnostic performance. Radiology 225:380–390PubMed McFarland EG, Pilgram TK, Brink JA, McDermott RA, Santillan CV, Brady PW, Heiken JP, Balfe DM, Weinstock LB, Thyssen EP, Littenberg (2002) CT colonography: multiobserver diagnostic performance. Radiology 225:380–390PubMed
12.
Zurück zum Zitat Taylor SA, Halligan S, Saunders BP, Morley S, Riesewyk C, Atkin W, Bartram CI (2003) Use of multidetector-row CT colonography for detection of colorectal neoplasia in patients referred via the Department of Health “2-Week-wait” initiative. Clin Radiol 58:855–861CrossRefPubMed Taylor SA, Halligan S, Saunders BP, Morley S, Riesewyk C, Atkin W, Bartram CI (2003) Use of multidetector-row CT colonography for detection of colorectal neoplasia in patients referred via the Department of Health “2-Week-wait” initiative. Clin Radiol 58:855–861CrossRefPubMed
13.
Zurück zum Zitat Dachman AH, Kuniyoshi JK, Boyle CM, Samara Y, Hoffmann KR, Rubin DT, Hanan I (1998) CT colonography with three-dimensional problem solving for detection of colonic polyps. Am J Roentgenol 171:989–995 Dachman AH, Kuniyoshi JK, Boyle CM, Samara Y, Hoffmann KR, Rubin DT, Hanan I (1998) CT colonography with three-dimensional problem solving for detection of colonic polyps. Am J Roentgenol 171:989–995
14.
Zurück zum Zitat Taylor SA, Halligan S, Goh V, Bassett P, Atkin W, Bartram CI (2003) Optimising colonic distension for multidetector-row CT colonography: effect of hyoscine butylbromide and rectal balloon catheter. Radiology 219:99–108 Taylor SA, Halligan S, Goh V, Bassett P, Atkin W, Bartram CI (2003) Optimising colonic distension for multidetector-row CT colonography: effect of hyoscine butylbromide and rectal balloon catheter. Radiology 219:99–108
15.
Zurück zum Zitat Kan L, Olivotto IA, Warren Burhenne LJ, Sickles EA, Coldman AJ (2000) Standardized abnormal interpretation and cancer detection ratios to assess reading volume and reader performance in a breast screening program. Radiology 215:563–567 Kan L, Olivotto IA, Warren Burhenne LJ, Sickles EA, Coldman AJ (2000) Standardized abnormal interpretation and cancer detection ratios to assess reading volume and reader performance in a breast screening program. Radiology 215:563–567
17.
Zurück zum Zitat Denton ER, Field S (1997) Just how valuable is double reporting in screening mammography? Clin Radiol 52:466–468PubMed Denton ER, Field S (1997) Just how valuable is double reporting in screening mammography? Clin Radiol 52:466–468PubMed
18.
Zurück zum Zitat Sickles EA, Wolverton DE, Dee KE (2002) Performance parameters for screening and diagnostic mammography: specialist and general radiologists. Radiology 224:861–869PubMed Sickles EA, Wolverton DE, Dee KE (2002) Performance parameters for screening and diagnostic mammography: specialist and general radiologists. Radiology 224:861–869PubMed
19.
Zurück zum Zitat Tudor GR, Finlay DB (2001) Error review: can this improve reporting performance? Clin Radiol 56:751–754CrossRefPubMed Tudor GR, Finlay DB (2001) Error review: can this improve reporting performance? Clin Radiol 56:751–754CrossRefPubMed
20.
Zurück zum Zitat Fidler JL, Johnson CD, MacCarty RL, Welch TJ, Hara AK, Harmsen WS (2002) Detection of flat lesions in the colon with CT colonography. Abdom Imaging 27:292–300PubMed Fidler JL, Johnson CD, MacCarty RL, Welch TJ, Hara AK, Harmsen WS (2002) Detection of flat lesions in the colon with CT colonography. Abdom Imaging 27:292–300PubMed
Metadaten
Titel
CT colonography: effect of experience and training on reader performance
verfasst von
Stuart A. Taylor
Steve Halligan
David Burling
Simon Morley
Paul Bassett
Wendy Atkin
Clive I. Bartram
Publikationsdatum
01.06.2004
Erschienen in
European Radiology / Ausgabe 6/2004
Print ISSN: 0938-7994
Elektronische ISSN: 1432-1084
DOI
https://doi.org/10.1007/s00330-004-2262-z

Weitere Artikel der Ausgabe 6/2004

European Radiology 6/2004 Zur Ausgabe

Update Radiologie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.