Abstract

The purpose of this study was to use cine-MRI during continuous respiration to measure the respiratory lumenal diameter change in the pharynx and at an upper tracheal level. Fifteen non-smokers and 23 chronic obstructive pulmonary disease (COPD) patients with smoking history (median 50 pack-years) were included. Cine-MRI with seven frames/s was performed during continuous respiration. Minimal and maximal cross-sectional lumenal diameters within the pharynx and the upper tracheal lumen area were measured. The median diameter change in the pharynx (tracheal area) was 70% (1.4 cm2) in volunteers and 76% (1.7 cm2) in smokers (P=0.98, P=0.04). Tracheal lumenal collapse was a median of 43% in volunteers and 64% in smokers (P=0.011). No clear disease-related difference of the pharynx-lumen was found. The maximal cross-sectional area of the upper trachea lumen as well as the respiratory collapse was larger in COPD patients than in normal subjects. This information is important for the modelling of ventilation and prediction of drug deposition, which are influenced by the airway diameter.
Anhänge
Nur mit Berechtigung zugänglich
Literatur
1.
Zurück zum Zitat Smith PL, O’Donnell CP, Allan L, Schwartz AR (2003) A physiologic comparison of nasal and oral positive airway pressure. Chest 123:689–694CrossRefPubMed Smith PL, O’Donnell CP, Allan L, Schwartz AR (2003) A physiologic comparison of nasal and oral positive airway pressure. Chest 123:689–694CrossRefPubMed
2.
Zurück zum Zitat Terris DJ, Kunda LD, Gonella MC (2002) Minimally invasive tongue base surgery for obstructive sleep apnoea. J Laryngol Otol 116:716–721CrossRefPubMed Terris DJ, Kunda LD, Gonella MC (2002) Minimally invasive tongue base surgery for obstructive sleep apnoea. J Laryngol Otol 116:716–721CrossRefPubMed
3.
Zurück zum Zitat Bijaoui EL, Champagne V, Baconnier PF, Kimoff RJ, Bates JH (2002) Mechanical properties of the lung and upper airways in patients with sleep-disordered breathing. Am J Respir Crit Care Med 165:1055–1061PubMed Bijaoui EL, Champagne V, Baconnier PF, Kimoff RJ, Bates JH (2002) Mechanical properties of the lung and upper airways in patients with sleep-disordered breathing. Am J Respir Crit Care Med 165:1055–1061PubMed
4.
Zurück zum Zitat Donnelly LF, Casper KA, Chen B, Koch BL (2002) Defining normal upper airway motion in asymptomatic children during sleep by means of cine-MR techniques. Radiology 223:176–180PubMed Donnelly LF, Casper KA, Chen B, Koch BL (2002) Defining normal upper airway motion in asymptomatic children during sleep by means of cine-MR techniques. Radiology 223:176–180PubMed
5.
Zurück zum Zitat Huppmann M, Schenk E, Kummer F (1990) Significance of expiratory bronchiolar collapse symptoms in the diagnosis of emphysema. Pneumologie 44:771–776PubMed Huppmann M, Schenk E, Kummer F (1990) Significance of expiratory bronchiolar collapse symptoms in the diagnosis of emphysema. Pneumologie 44:771–776PubMed
6.
7.
Zurück zum Zitat Heussel CP, Hafner B, Lill J, Thelen M, Kauczor H-U (2001) Paired inspiratory/expiratory spiral-CT and continuous respiration cine-CT in the diagnosis of tracheal instability. Eur Radiol 11:982–989CrossRefPubMed Heussel CP, Hafner B, Lill J, Thelen M, Kauczor H-U (2001) Paired inspiratory/expiratory spiral-CT and continuous respiration cine-CT in the diagnosis of tracheal instability. Eur Radiol 11:982–989CrossRefPubMed
8.
Zurück zum Zitat Kauczor HU, Hast J, Heussel CP, Schlegel J, Mildenberger P, Thelen M (2002) CT attenuation of paired HRCT scans obtained at full inspiratory/expiratory position: comparison with pulmonary function tests. Eur Radiol 12:2757–2763PubMed Kauczor HU, Hast J, Heussel CP, Schlegel J, Mildenberger P, Thelen M (2002) CT attenuation of paired HRCT scans obtained at full inspiratory/expiratory position: comparison with pulmonary function tests. Eur Radiol 12:2757–2763PubMed
9.
Zurück zum Zitat Heussel CP, Hafner B, Lill J, Thelen M, Kauczor H-U (2000) Diagnosis of tracheal instability: inspiratory and expiratory spiral CT and cine CT. Fortschr Roentgenstr 172:115–121 Heussel CP, Hafner B, Lill J, Thelen M, Kauczor H-U (2000) Diagnosis of tracheal instability: inspiratory and expiratory spiral CT and cine CT. Fortschr Roentgenstr 172:115–121
10.
Zurück zum Zitat Ferretti GR, Kocier M, Calaque O, ArbibF, Righini C, Coulomb M, Pison C (2003) Follow-up after stent insertion in the tracheobronchial tree: role of helical computed tomography in comparison with fiberoptic bronchoscopy. Eur Radiol 13:1172–1178 Ferretti GR, Kocier M, Calaque O, ArbibF, Righini C, Coulomb M, Pison C (2003) Follow-up after stent insertion in the tracheobronchial tree: role of helical computed tomography in comparison with fiberoptic bronchoscopy. Eur Radiol 13:1172–1178
11.
Zurück zum Zitat Eastwood PR, Szollosi I, Platt PR, Hillman DR (2002) Collapsibility of the upper airway during anesthesia with isoflurane. Anesthesiology 97:786–793CrossRefPubMed Eastwood PR, Szollosi I, Platt PR, Hillman DR (2002) Collapsibility of the upper airway during anesthesia with isoflurane. Anesthesiology 97:786–793CrossRefPubMed
12.
Zurück zum Zitat Eastwood PR, Szollosi I, Platt PR, Hillman DR (2002) Comparison of upper airway collapse during general anaesthesia and sleep. Lancet 359(9313):1207–1209CrossRefPubMed Eastwood PR, Szollosi I, Platt PR, Hillman DR (2002) Comparison of upper airway collapse during general anaesthesia and sleep. Lancet 359(9313):1207–1209CrossRefPubMed
13.
Zurück zum Zitat Kauczor HU, Hanke A, Van Beek EJ (2002) Assessment of lung ventilation by MR imaging: current status and future perspectives. Eur Radiol 12:1962–1670PubMed Kauczor HU, Hanke A, Van Beek EJ (2002) Assessment of lung ventilation by MR imaging: current status and future perspectives. Eur Radiol 12:1962–1670PubMed
14.
Zurück zum Zitat Ley S, Mayer D, Brook BS, van Beek EJR, Heussel CP, Rinck D, Hose R, Markstaller K, Kauczor H-U (2002) Radiological imaging as the basis for a simulation software of ventilation in the tracheo-bronchial tree. Eur Radiol 12:2218–2228PubMed Ley S, Mayer D, Brook BS, van Beek EJR, Heussel CP, Rinck D, Hose R, Markstaller K, Kauczor H-U (2002) Radiological imaging as the basis for a simulation software of ventilation in the tracheo-bronchial tree. Eur Radiol 12:2218–2228PubMed
15.
Zurück zum Zitat Janssens HM, De Jongste JC, Hop WC, Tiddens HA (2003) Extra-fine particles improve lung delivery of inhaled steroids in infants: a study in an upper airway model. Chest 123:2083–2088CrossRefPubMed Janssens HM, De Jongste JC, Hop WC, Tiddens HA (2003) Extra-fine particles improve lung delivery of inhaled steroids in infants: a study in an upper airway model. Chest 123:2083–2088CrossRefPubMed
16.
Zurück zum Zitat Vikgren J, Johansson A, Gustavsson S, Moonen M, Bake B, Tylén U (2003) On visual determination of full inspiration on CT images. Eur Radiol 13:1235–1240PubMed Vikgren J, Johansson A, Gustavsson S, Moonen M, Bake B, Tylén U (2003) On visual determination of full inspiration on CT images. Eur Radiol 13:1235–1240PubMed
17.
Zurück zum Zitat Ederle JR, Heussel CP, Hast J, Fischer B, Van Beek EJR, Ley S, Thelen M, Kauczor HU (2003) Evaluation of changes in central airway dimensions, lung area and mean lung density at paired inspiratory/expiratory high-resolution computed tomography. Eur Radiol 13:2454–2461. DOI 10.1007/s00330-003-1909-5CrossRefPubMed Ederle JR, Heussel CP, Hast J, Fischer B, Van Beek EJR, Ley S, Thelen M, Kauczor HU (2003) Evaluation of changes in central airway dimensions, lung area and mean lung density at paired inspiratory/expiratory high-resolution computed tomography. Eur Radiol 13:2454–2461. DOI 10.​1007/​s00330-003-1909-5CrossRefPubMed
18.
Zurück zum Zitat Stern EJ, Graham CM, Webb WR, Gamsu G (1993) Normal trachea during forced expiration: dynamic CT measurements. Radiology 187:27–31PubMed Stern EJ, Graham CM, Webb WR, Gamsu G (1993) Normal trachea during forced expiration: dynamic CT measurements. Radiology 187:27–31PubMed
19.
Zurück zum Zitat Tiddens HA, Hofhuis W, Bogaard JM, Hop WC, de Bruin H, Willems LN, de Jongste JC (1999) Compliance, hysteresis, and collapsibility of human small airways. Am J Respir Crit Care Med 160:1110–1118PubMed Tiddens HA, Hofhuis W, Bogaard JM, Hop WC, de Bruin H, Willems LN, de Jongste JC (1999) Compliance, hysteresis, and collapsibility of human small airways. Am J Respir Crit Care Med 160:1110–1118PubMed
20.
Zurück zum Zitat Roca J, Burgos F, Sunyer J, Saez M, Chinn S, Anto JM, Rodriguez-Roisin R, Quanjer PH, Nowak D, Burney P (1998) References values for forced spirometry. Group of the European Community Respiratory Health Survey. Eur Respir J 11:1354–1362CrossRefPubMed Roca J, Burgos F, Sunyer J, Saez M, Chinn S, Anto JM, Rodriguez-Roisin R, Quanjer PH, Nowak D, Burney P (1998) References values for forced spirometry. Group of the European Community Respiratory Health Survey. Eur Respir J 11:1354–1362CrossRefPubMed
21.
Zurück zum Zitat Muro S, Nakano Y, Sakai H, Takubo Y, Oku Y, Chin K, Nishimura K, Hirai T, Kawakami K, Nakamura T, Mishima M (2000) Distorted trachea in patients with chronic obstructive pulmonary disease. Respiration 67:638–644CrossRefPubMed Muro S, Nakano Y, Sakai H, Takubo Y, Oku Y, Chin K, Nishimura K, Hirai T, Kawakami K, Nakamura T, Mishima M (2000) Distorted trachea in patients with chronic obstructive pulmonary disease. Respiration 67:638–644CrossRefPubMed
23.
Zurück zum Zitat Kane AA, Butman JA, Mullick R, Skopec M, Choyke P (2002) A new method for the study of velopharyngeal function using gated magnetic resonance imaging. Plast Reconstr Surg 109:472–481CrossRefPubMed Kane AA, Butman JA, Mullick R, Skopec M, Choyke P (2002) A new method for the study of velopharyngeal function using gated magnetic resonance imaging. Plast Reconstr Surg 109:472–481CrossRefPubMed
24.
Zurück zum Zitat Donnelly LF, Surdulescu V, Chini BA, Casper KA, Poe SA, Amin RS (2003) Upper airway motion depicted at cine-MR imaging performed during sleep: comparison between young patients with and those without obstructive sleep apnea. Radiology 227:239–245PubMed Donnelly LF, Surdulescu V, Chini BA, Casper KA, Poe SA, Amin RS (2003) Upper airway motion depicted at cine-MR imaging performed during sleep: comparison between young patients with and those without obstructive sleep apnea. Radiology 227:239–245PubMed
25.
Zurück zum Zitat American Thoracic Society (1999) Pulmonary rehabilitation. Am J Respir Crit Care Med 159:1666–1682 American Thoracic Society (1999) Pulmonary rehabilitation. Am J Respir Crit Care Med 159:1666–1682
26.
Zurück zum Zitat Perlyn CA, Schmelzer RE, Sutera SP, Kane AA, Govier D, Marsh JL (2002) Effect of distraction osteogenesis of the mandible on upper airway volume and resistance in children with micrognathia. Plast Reconstr Surg 109:1809–1818CrossRefPubMed Perlyn CA, Schmelzer RE, Sutera SP, Kane AA, Govier D, Marsh JL (2002) Effect of distraction osteogenesis of the mandible on upper airway volume and resistance in children with micrognathia. Plast Reconstr Surg 109:1809–1818CrossRefPubMed
27.
Zurück zum Zitat Puente-Maestu L, Abad MJ, Godoy R, Perez-Parra JM, Cubillo JM, Whipp BJ (2002) Breath-by-breath fluctuations of pulmonary gas exchange and ventilation in COPD patients. Eur J Appl Physiol 87:535–541CrossRefPubMed Puente-Maestu L, Abad MJ, Godoy R, Perez-Parra JM, Cubillo JM, Whipp BJ (2002) Breath-by-breath fluctuations of pulmonary gas exchange and ventilation in COPD patients. Eur J Appl Physiol 87:535–541CrossRefPubMed
28.
Zurück zum Zitat Myers J, Walsh D, Sullivan M, Froelicher V (1990) Effect of sampling on variability and plateau in oxygen uptake. J Appl Physiol 68:404–410CrossRefPubMed Myers J, Walsh D, Sullivan M, Froelicher V (1990) Effect of sampling on variability and plateau in oxygen uptake. J Appl Physiol 68:404–410CrossRefPubMed
Metadaten
Titel
Respiratory lumenal change of the pharynx and trachea in normal subjects and COPD patients: assessment by cine-MRI
verfasst von
Claus Peter Heussel
Sebastian Ley
Alexander Biedermann
Anja Rist
Klaus Kurt Gast
Wolfgang G. Schreiber
Hans-Ulrich Kauczor
Publikationsdatum
01.12.2004
Erschienen in
European Radiology / Ausgabe 12/2004
Print ISSN: 0938-7994
Elektronische ISSN: 1432-1084
DOI
https://doi.org/10.1007/s00330-004-2461-7

Weitere Artikel der Ausgabe 12/2004

European Radiology 12/2004 Zur Ausgabe

Update Radiologie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.