The purpose of this study was to determine the gonadal dose, effective dose and relevant radiogenic risks associated with pediatric patients undergoing voiding cystourethrography (VCUG). Exposure parameters were monitored in 118 consecutive children undergoing VCUG. The entrance surface dose (ESD) was determined by thermoluminescent dosimeters (TLDs). For male patients, the gonadal dose was determined by TLDs attached on the anterior scrotum. For female patients, the gonadal dose was estimated by converting ESD to the ovarian dose. ESD-to-ovarian dose conversion factors were determined by thermoluminescence dosimetry and physical anthropomorphic phantoms representing newborn and 1-, 5- and 10-year-old individuals. The effective dose was estimated by using ESD and data obtained from the literature. The mean fluoroscopy time and number of radiographs during VCUG were 0.73 min and 2.3 for female and 0.91 min and 3.0 for male pediatric patients, respectively. The gonadal dose range was 0.34–5.17 mGy in boys and 0.36–2.57 mGy in girls. The corresponding ranges of effective dosage were 0.12–1.67 mSv and 0.15–1.45 mSv. Mean radiation risks for genetic anomalies and carcinogenesis following VCUG during childhood were estimated to be up to 15 per million and 125 per million, respectively. Radiation risks associated with pediatric patients undergoing VCUG should not be disregarded if such a procedure is to be justified adequately.
Literatur
1.
Zurück zum Zitat Riccabona M (2002) Cystography in infants and children: a critical appraisal of the many forms with special regard to voiding cystourethrography. Eur Radiol 12:2910–2918PubMed Riccabona M (2002) Cystography in infants and children: a critical appraisal of the many forms with special regard to voiding cystourethrography. Eur Radiol 12:2910–2918PubMed
2.
Zurück zum Zitat Agrawalla S, Pearce R, Goodman TR (2004) How to perform the perfect voiding cystourethrogram. Pediatr Radiol 34:114–119PubMed Agrawalla S, Pearce R, Goodman TR (2004) How to perform the perfect voiding cystourethrogram. Pediatr Radiol 34:114–119PubMed
3.
Zurück zum Zitat Hall EJ (2002) Lessons we have learned from our children: cancer risks from diagnostic radiology. Pediatr Radiol 32:700–706PubMed Hall EJ (2002) Lessons we have learned from our children: cancer risks from diagnostic radiology. Pediatr Radiol 32:700–706PubMed
4.
Zurück zum Zitat Suleiman OH (2004) Radiation doses in pediatric radiology: influence of radiation and standards. Pediatr Radiol 34 (Suppl 3):242–246 Suleiman OH (2004) Radiation doses in pediatric radiology: influence of radiation and standards. Pediatr Radiol 34 (Suppl 3):242–246
5.
Zurück zum Zitat Goodman R (2005) Are routine oblique full bladder views necessary in the pediatric voiding cystourethrogram (VCUG)? Pediatr Radiol 35 (Suppl 1):42 Goodman R (2005) Are routine oblique full bladder views necessary in the pediatric voiding cystourethrogram (VCUG)? Pediatr Radiol 35 (Suppl 1):42
6.
Zurück zum Zitat Hart D, Jones DG, Wall BF (1996) Estimation of effective doses for pediatric X-ray examinations. NRPB-R279, National Radiological Protection Board, Chilton Hart D, Jones DG, Wall BF (1996) Estimation of effective doses for pediatric X-ray examinations. NRPB-R279, National Radiological Protection Board, Chilton
7.
Zurück zum Zitat Le Heron JC (1998) CHILDOSE. Ministry of Health, National Radiation Laboratory, Christchurch, New Zealand Le Heron JC (1998) CHILDOSE. Ministry of Health, National Radiation Laboratory, Christchurch, New Zealand
8.
Zurück zum Zitat ICRP 79 (1996) Radiological protection and safety in medicine. ICRP Publication 79. In: Ann ICRP. 26: 2, Pergamon Press, Oxford ICRP 79 (1996) Radiological protection and safety in medicine. ICRP Publication 79. In: Ann ICRP. 26: 2, Pergamon Press, Oxford
9.
Zurück zum Zitat National Research Council (1990) Health effects exposure to low levels of ionizing radiation. BEIR V: National Academy Press, Washington DC National Research Council (1990) Health effects exposure to low levels of ionizing radiation. BEIR V: National Academy Press, Washington DC
10.
Zurück zum Zitat ICRP 60 (1990) Recommendations of the International Commission on Radiological Protection. ICRP Publication 60. In: Ann ICRP. 21:1–3. Pergamon Press, Oxford ICRP 60 (1990) Recommendations of the International Commission on Radiological Protection. ICRP Publication 60. In: Ann ICRP. 21:1–3. Pergamon Press, Oxford
11.
Zurück zum Zitat Wall BF (2004) Radiation protection dosimetry for diagnostic radiology patients. Radiat Prot Dosim 109:409–419 Wall BF (2004) Radiation protection dosimetry for diagnostic radiology patients. Radiat Prot Dosim 109:409–419
12.
Zurück zum Zitat Kim SH, Kim SH, Park BK, Jung SY, Hwang SI, Paick JS, Kim SW (2005) CT voiding cystourethrography using 16-MDCT for the evaluation of female urethral diverticula: initial experience. Am J Roentgenol 184:1594–1596 Kim SH, Kim SH, Park BK, Jung SY, Hwang SI, Paick JS, Kim SW (2005) CT voiding cystourethrography using 16-MDCT for the evaluation of female urethral diverticula: initial experience. Am J Roentgenol 184:1594–1596
13.
Zurück zum Zitat Borthne AS, Pierre-Jerome C, Gjesdal KI, Storaas T, Courivaud F, Eriksen M (2003) Pediatric excretory MR urography: comparative study of enhanced and non-enhanced techniques. Eur Radiol 13:1423–1427PubMed Borthne AS, Pierre-Jerome C, Gjesdal KI, Storaas T, Courivaud F, Eriksen M (2003) Pediatric excretory MR urography: comparative study of enhanced and non-enhanced techniques. Eur Radiol 13:1423–1427PubMed
14.
Zurück zum Zitat Almen A, Mattsson S (1995) The radiation dose to children from X-ray examinations of the pelvis. Br J Radiol 68:604–613CrossRefPubMed Almen A, Mattsson S (1995) The radiation dose to children from X-ray examinations of the pelvis. Br J Radiol 68:604–613CrossRefPubMed
15.
Zurück zum Zitat Schultz FW, Geleijns J, Holscher HC, Weststrate J, Zonerland HM, Zoetelief J (1999) Radiation burden to pediatric patients due to micturating cystourethrography examinations in a Dutch children's hospital. Br J Radiol 72:763–772PubMed Schultz FW, Geleijns J, Holscher HC, Weststrate J, Zonerland HM, Zoetelief J (1999) Radiation burden to pediatric patients due to micturating cystourethrography examinations in a Dutch children's hospital. Br J Radiol 72:763–772PubMed
16.
Zurück zum Zitat Fotakis M, Molybda-Athanasopoulou E, Psarrakos K, Economou I (2003) Radiation doses to pediatric patients up to 5 years of age undergoing micturating cystourethrography examinations and its dependence on patient age: a Monte Carlo study. Br J Radiol 76:812–817PubMed Fotakis M, Molybda-Athanasopoulou E, Psarrakos K, Economou I (2003) Radiation doses to pediatric patients up to 5 years of age undergoing micturating cystourethrography examinations and its dependence on patient age: a Monte Carlo study. Br J Radiol 76:812–817PubMed
17.
Zurück zum Zitat Persliden J, Helmrot E, Hjort P, Resjo M (2004) Dose and image quality in the comparison of analogue and digital techniques in pediatric urology examinations. Eur Radiol 14:638–644PubMed Persliden J, Helmrot E, Hjort P, Resjo M (2004) Dose and image quality in the comparison of analogue and digital techniques in pediatric urology examinations. Eur Radiol 14:638–644PubMed
18.
Zurück zum Zitat Chapple CL, Faulkner K, Lee REJ, Hunter EW (1992) Results of a survey of doses to paediatric patients undergoing common radiological examinations. Br J Radiol 65:225–231PubMed Chapple CL, Faulkner K, Lee REJ, Hunter EW (1992) Results of a survey of doses to paediatric patients undergoing common radiological examinations. Br J Radiol 65:225–231PubMed
19.
Zurück zum Zitat Cleveland RH, Constantinou C, Blickman JG, Jaramillo D, Webster E (1992) Voiding cystourethrography in children: value of digital fluoroscopy in reducing radiation dose. Am J Roentgenol 152:137–142 Cleveland RH, Constantinou C, Blickman JG, Jaramillo D, Webster E (1992) Voiding cystourethrography in children: value of digital fluoroscopy in reducing radiation dose. Am J Roentgenol 152:137–142
20.
Zurück zum Zitat Brenner DJ, Elliston CD, Hall EJ, Brendon WE (2001) Estimated risks of radiation-induced fatal cancer from pediatric CT. Am J Roentgenol 176:289–296 Brenner DJ, Elliston CD, Hall EJ, Brendon WE (2001) Estimated risks of radiation-induced fatal cancer from pediatric CT. Am J Roentgenol 176:289–296
Metadaten
Titel
Fluoroscopy-controlled voiding cystourethrography in infants and children: Are the radiation risks trivial?
verfasst von
Kostas Perisinakis
Maria Raissaki
John Damilakis
John Stratakis
John Neratzoulakis
Nicholas Gourtsoyiannis
Publikationsdatum
01.04.2006
Verlag
Springer-Verlag
Erschienen in
European Radiology / Ausgabe 4/2006
Print ISSN: 0938-7994
Elektronische ISSN: 1432-1084
DOI
https://doi.org/10.1007/s00330-005-0072-6

Weitere Artikel der Ausgabe 4/2006

European Radiology 4/2006 Zur Ausgabe

Update Radiologie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.