Erschienen in: European Radiology 5/2006

01.05.2006 | Contrast Media

Effects of iodinated contrast media on blood and endothelium

verfasst von: Peter Aspelin, Fulvio Stacul, Henrik S. Thomsen, Sameh K. Morcos, Aart J. van der Molen, Members of the Contrast Media Safety Committee of the European Society of Urogenital Radiology (ESUR)

Erschienen in: European Radiology | Ausgabe 5/2006

Einloggen, um Zugang zu erhalten

Abstract

The aim of the study was to assess the effects of iodinated contrast media on blood components and endothelium based on experimental and clinical studies and to produce clinically relevant guidelines for reducing thrombotic and hematologic complications following the intravascular use of contrast media. A report was drafted after review of the literature and discussions among the members of the Contrast Media Safety Committee of the European Society of Urogenital Radiology. The final report was produced following discussion at the 12th European Symposium on Urogenital Radiology in Ljubljana, Slovenia (2005). Experimental data indicate that all iodinated contrast media produce an anticoagulant effect and that this effect is greater with ionic contrast media. Several of the in vitro and experimental in vivo studies on haematological effects of contrast media have not been confirmed by clinical studies. Low- or iso-osmolar contrast media should be used for diagnostic and interventional angiographic procedures, including phlebography. Meticulous angiographic technique is the most important factor for reducing the thrombotic complications associated with angiographic procedures. Drugs and interventional devices that decrease the risk of thromboembolic complications during interventional procedures minimize the importance of the effects of contrast media.
Literatur
1.
Zurück zum Zitat Aspelin P, Stöhr-Liessen M, Almén T (1980) Effect of Iohexol on human erythrocytes, I. Changes of red cell morphology in vitro. Acta Radiol Suppl 362:117–122PubMed Aspelin P, Stöhr-Liessen M, Almén T (1980) Effect of Iohexol on human erythrocytes, I. Changes of red cell morphology in vitro. Acta Radiol Suppl 362:117–122PubMed
2.
Zurück zum Zitat Nash GB, Meiselman HJ (1991) Effect of dehydration on the viscoelastic behaviour of red cells. Blood Cells 17:517–522PubMed Nash GB, Meiselman HJ (1991) Effect of dehydration on the viscoelastic behaviour of red cells. Blood Cells 17:517–522PubMed
3.
Zurück zum Zitat Chronos NAF, Goodall AH, Wilson DJ, Sigwart U, Buller NP (1993) Profound platelet degranulation is an important side effect of some types of contrast media used in interventional cardiology. Circulation 88:2035–2044PubMed Chronos NAF, Goodall AH, Wilson DJ, Sigwart U, Buller NP (1993) Profound platelet degranulation is an important side effect of some types of contrast media used in interventional cardiology. Circulation 88:2035–2044PubMed
4.
Zurück zum Zitat Hardeman MR, Goedhart P, Koen IY (1991) The effect of low-osmolar ionic and nonionic contrast media on human blood viscosity, erythrocyte morphology, and aggregation behavior. Invest Radiol 26:810–819PubMed Hardeman MR, Goedhart P, Koen IY (1991) The effect of low-osmolar ionic and nonionic contrast media on human blood viscosity, erythrocyte morphology, and aggregation behavior. Invest Radiol 26:810–819PubMed
5.
Zurück zum Zitat Aspelin P, Nilsson PE, Schmid-Schonbein H, Schroder S, Simon R (1987) Effect of four nonionic contrast media on red blood cells in vitro. III. Deformability. Acta Radiol Suppl 370:89–91PubMed Aspelin P, Nilsson PE, Schmid-Schonbein H, Schroder S, Simon R (1987) Effect of four nonionic contrast media on red blood cells in vitro. III. Deformability. Acta Radiol Suppl 370:89–91PubMed
6.
Zurück zum Zitat Aspelin P, Schmid-Schönbein H (1978) Effect of ionic and nonionic contrast media on red cell aggregation in vitro. Acta Radiol Diagn (Stockh) 19:766–784 Aspelin P, Schmid-Schönbein H (1978) Effect of ionic and nonionic contrast media on red cell aggregation in vitro. Acta Radiol Diagn (Stockh) 19:766–784
7.
Zurück zum Zitat Aspelin P (1992) Contrast media and red blood cell aggregation: interaction dangerous or harmless from a clinical view—an overview. Clin Hemorheol Microcirc 12:401–406 Aspelin P (1992) Contrast media and red blood cell aggregation: interaction dangerous or harmless from a clinical view—an overview. Clin Hemorheol Microcirc 12:401–406
8.
Zurück zum Zitat Losco P, Nash G, Stone P, Ventre J (2001) Comparison of the effects of radiographic contrast media on dehydration and filterability of red blood cells from donors homozygous for hemoglobin A or hemoglobin S. Am J Hematol 68:149–158CrossRefPubMed Losco P, Nash G, Stone P, Ventre J (2001) Comparison of the effects of radiographic contrast media on dehydration and filterability of red blood cells from donors homozygous for hemoglobin A or hemoglobin S. Am J Hematol 68:149–158CrossRefPubMed
9.
Zurück zum Zitat Dawson P, Harrison M, Weisblatt E (1983) Effect of contrast media on red cell filtrability and morphology. Br J Radiol 56:707–710PubMedCrossRef Dawson P, Harrison M, Weisblatt E (1983) Effect of contrast media on red cell filtrability and morphology. Br J Radiol 56:707–710PubMedCrossRef
10.
Zurück zum Zitat Le Mignon MM, Ducret MN, Bonnemain B, Donadieu AM (1988) Effect of contrast media on whole blood filtrability. Acta Radiol 29:593–597PubMed Le Mignon MM, Ducret MN, Bonnemain B, Donadieu AM (1988) Effect of contrast media on whole blood filtrability. Acta Radiol 29:593–597PubMed
11.
Zurück zum Zitat Strickland N, Rampling M, Dawson P, Martin G (1992) The effects of contrast media on the rheological properties of blood. Clin Hemorheol Microcirc 12:369–379 Strickland N, Rampling M, Dawson P, Martin G (1992) The effects of contrast media on the rheological properties of blood. Clin Hemorheol Microcirc 12:369–379
12.
Zurück zum Zitat Pugh ND (1996) Haemodynamic and rheological effects of contrast media: the role of viscosity and osmolality. Eur Radiol 6 [Suppl 2]:S13–S15CrossRefPubMed Pugh ND (1996) Haemodynamic and rheological effects of contrast media: the role of viscosity and osmolality. Eur Radiol 6 [Suppl 2]:S13–S15CrossRefPubMed
13.
Zurück zum Zitat Morcos SK, Dawson P, Pearson JD, et al (1998) The haemodynamic effects of iodinated water soluble radiographic contrast media: a review. Eur J Radiol 29:31–46CrossRefPubMed Morcos SK, Dawson P, Pearson JD, et al (1998) The haemodynamic effects of iodinated water soluble radiographic contrast media: a review. Eur J Radiol 29:31–46CrossRefPubMed
14.
Zurück zum Zitat Mills SR, Jackson BF, Older RA, Heaston DK, Moore AV (1980) The incidence, aetiologies and avoidance of complications of pulmonary angiography in a large series. Radiology 136:295–299PubMed Mills SR, Jackson BF, Older RA, Heaston DK, Moore AV (1980) The incidence, aetiologies and avoidance of complications of pulmonary angiography in a large series. Radiology 136:295–299PubMed
15.
Zurück zum Zitat Almén T, Aspelin P, Nilsson P (1980) Aortic and pulmonary arterial pressure after injection of contrast media into the right atrium of the rabbit. Comparison between metrizoate, ioxaglate and iohexol. Acta Radiol Suppl 362:37–41PubMed Almén T, Aspelin P, Nilsson P (1980) Aortic and pulmonary arterial pressure after injection of contrast media into the right atrium of the rabbit. Comparison between metrizoate, ioxaglate and iohexol. Acta Radiol Suppl 362:37–41PubMed
16.
Zurück zum Zitat Liss P, Nygren A, Olsson U, Ulfendahl HR, Erikson U (1996) Effects of contrast media and mannitol on renal medullary blood flow and red cell aggregation in the rat kidney. Kidney Int 49:1268–1275PubMed Liss P, Nygren A, Olsson U, Ulfendahl HR, Erikson U (1996) Effects of contrast media and mannitol on renal medullary blood flow and red cell aggregation in the rat kidney. Kidney Int 49:1268–1275PubMed
17.
Zurück zum Zitat Galtung HK, Sörlundsengen V, Sakariassen KS, Benestad H (2002) Effect of radiologic contrast media on cell volume regulatory mechanisms in human red blood cells. Acad Radiol 9:878–885CrossRefPubMed Galtung HK, Sörlundsengen V, Sakariassen KS, Benestad H (2002) Effect of radiologic contrast media on cell volume regulatory mechanisms in human red blood cells. Acad Radiol 9:878–885CrossRefPubMed
18.
Zurück zum Zitat Strickland NH, Rampling MW, Dawson P, Martin G (1992) Contrast media-induced effects on blood rheology and their importance in angiography. Clin Radiol 45:240–242CrossRefPubMed Strickland NH, Rampling MW, Dawson P, Martin G (1992) Contrast media-induced effects on blood rheology and their importance in angiography. Clin Radiol 45:240–242CrossRefPubMed
19.
Zurück zum Zitat Rasmussen F, Georgsen J, Grunnet N (1988) Influence of radiographic contrast media on phagocytosis. Acta Radiol 29:589–592PubMed Rasmussen F, Georgsen J, Grunnet N (1988) Influence of radiographic contrast media on phagocytosis. Acta Radiol 29:589–592PubMed
20.
Zurück zum Zitat Rasmussen F (1998) The influence of radiographic contrast media on some granulocyte functions. Acta Radiol Suppl 419:333–337 Rasmussen F (1998) The influence of radiographic contrast media on some granulocyte functions. Acta Radiol Suppl 419:333–337
21.
Zurück zum Zitat Rasmussen F, Georgsen J, Antonsen S, Grunnet N (1992) Phagocytic properties of granulocytes after intravenous injection of ioxaglate or iohexol. Acta Radiol 33:271–274PubMed Rasmussen F, Georgsen J, Antonsen S, Grunnet N (1992) Phagocytic properties of granulocytes after intravenous injection of ioxaglate or iohexol. Acta Radiol 33:271–274PubMed
22.
Zurück zum Zitat Rasmussen F, Georgsen J, Pedersen JO, Antonsen S (1992) Granulocyte chemotaxis before and after urography. Influence of four different contrast media. Acta Radiol 33:164–168PubMed Rasmussen F, Georgsen J, Pedersen JO, Antonsen S (1992) Granulocyte chemotaxis before and after urography. Influence of four different contrast media. Acta Radiol 33:164–168PubMed
23.
Zurück zum Zitat Rasmussen F, Antonsen S, Georgsen J (1992) Granulocyte adherence is inhibited by radiographic contrast media in vitro. Acta Radiol 33:379–383PubMed Rasmussen F, Antonsen S, Georgsen J (1992) Granulocyte adherence is inhibited by radiographic contrast media in vitro. Acta Radiol 33:379–383PubMed
24.
Zurück zum Zitat Barani J, Gottsater A, Mattiasson I, Lindblad B (2002) Platelet and leukocyte activation during aortoiliac angiography and angioplasty. Eur J Vasc Endovasc Surg 23:220–225CrossRefPubMed Barani J, Gottsater A, Mattiasson I, Lindblad B (2002) Platelet and leukocyte activation during aortoiliac angiography and angioplasty. Eur J Vasc Endovasc Surg 23:220–225CrossRefPubMed
25.
Zurück zum Zitat Blann AD, Adams R, Ashleigh R, Naser S, Kirkpatrick U, McCollum CN (2001) Changes in endothelial, leucocyte and platelet markers following contrast medium injection during angiography in patients with peripheral artery disease. Br J Radiol 74:811–817PubMed Blann AD, Adams R, Ashleigh R, Naser S, Kirkpatrick U, McCollum CN (2001) Changes in endothelial, leucocyte and platelet markers following contrast medium injection during angiography in patients with peripheral artery disease. Br J Radiol 74:811–817PubMed
26.
Zurück zum Zitat Zhan X, Agrawal DK, Thorpe PE (1998) Effect of iodinated contrast media on neutrophil adhesion to cultured endothelial cells. J Vasc Interv Radiol 9:808–816; erratum in J Vasc Interv Radiol (1998) 9:889PubMedCrossRef Zhan X, Agrawal DK, Thorpe PE (1998) Effect of iodinated contrast media on neutrophil adhesion to cultured endothelial cells. J Vasc Interv Radiol 9:808–816; erratum in J Vasc Interv Radiol (1998) 9:889PubMedCrossRef
27.
Zurück zum Zitat Hernanz-Schulman M, Vanholder R, Waterloos M-A, Hakim R, Schulman G (2000) Effect of radiographic contrast agents on leukocyte metabolic response. Pediatr Radiol 30:361–368CrossRefPubMed Hernanz-Schulman M, Vanholder R, Waterloos M-A, Hakim R, Schulman G (2000) Effect of radiographic contrast agents on leukocyte metabolic response. Pediatr Radiol 30:361–368CrossRefPubMed
28.
Zurück zum Zitat Fanning NF, Manning BJ, Buckley J, Redmond HP (2002) Iodinated contrast media induced neutrophil apoptosis through a mitochondrial and caspase mediated pathway. Br J Radiol 75:861–873PubMed Fanning NF, Manning BJ, Buckley J, Redmond HP (2002) Iodinated contrast media induced neutrophil apoptosis through a mitochondrial and caspase mediated pathway. Br J Radiol 75:861–873PubMed
29.
Zurück zum Zitat Laskey WK, Gellman J (2003) Inflammatory markers increase following exposure to radiographic contrast media. Acta Radiol 44:498–503CrossRefPubMed Laskey WK, Gellman J (2003) Inflammatory markers increase following exposure to radiographic contrast media. Acta Radiol 44:498–503CrossRefPubMed
30.
Zurück zum Zitat Pearson JD (1991) Endothelial cell biology. Radiology 179:9–14PubMed Pearson JD (1991) Endothelial cell biology. Radiology 179:9–14PubMed
31.
Zurück zum Zitat Morcos SK (1998) Contrast media-induced nephrotoxicity—questions and answers. Br J Radiol 71:357–365PubMed Morcos SK (1998) Contrast media-induced nephrotoxicity—questions and answers. Br J Radiol 71:357–365PubMed
32.
Zurück zum Zitat Oldroyd SD, Morcos SK (2000) Endothelin: what does the radiologist need to know? Br J Radiol 73:1246–1251PubMed Oldroyd SD, Morcos SK (2000) Endothelin: what does the radiologist need to know? Br J Radiol 73:1246–1251PubMed
33.
Zurück zum Zitat Schwartz D, Blum M, Peer G, et al (1994) Role of nitric oxide (EDRF) in radiocontrast acute renal failure in rats. Am J Physiol 267:F374–F379PubMed Schwartz D, Blum M, Peer G, et al (1994) Role of nitric oxide (EDRF) in radiocontrast acute renal failure in rats. Am J Physiol 267:F374–F379PubMed
34.
Zurück zum Zitat Heyman S, Goldfarb M, Carmeli F, Shina A, Rahmilewitz D, Brezis M (1998) Effects of radiocontrast agents on intrarenal nitric oxide (NO) and NO synthase activity. Exp Nephrol 6:557–562CrossRefPubMed Heyman S, Goldfarb M, Carmeli F, Shina A, Rahmilewitz D, Brezis M (1998) Effects of radiocontrast agents on intrarenal nitric oxide (NO) and NO synthase activity. Exp Nephrol 6:557–562CrossRefPubMed
35.
Zurück zum Zitat Barstad RM, Buchmann MS, Hamers MJ, et al (1996) Effects of ionic and nonionic contrast media on endothelium and on arterial thrombus formation. Acta Radiol 37:954–961PubMed Barstad RM, Buchmann MS, Hamers MJ, et al (1996) Effects of ionic and nonionic contrast media on endothelium and on arterial thrombus formation. Acta Radiol 37:954–961PubMed
36.
Zurück zum Zitat Wilson AJ, Sage MR (1994) Cytochemical studies on contrast medium-induced blood–brain barrier damage. Invest Radiol 29 [Suppl 2]:S105–S107PubMed Wilson AJ, Sage MR (1994) Cytochemical studies on contrast medium-induced blood–brain barrier damage. Invest Radiol 29 [Suppl 2]:S105–S107PubMed
37.
Zurück zum Zitat Laerum F (1983) Acute damage to human endothelial cells by brief exposure to contrast media in vitro. Radiology 147:681–684PubMed Laerum F (1983) Acute damage to human endothelial cells by brief exposure to contrast media in vitro. Radiology 147:681–684PubMed
38.
Zurück zum Zitat Morgan DML, Bettmann MA (1989) Effects of X-ray contrast media and radiation on human vascular endothelial cells in vitro. Cardiovasc Interv Radiol 12:154–160 Morgan DML, Bettmann MA (1989) Effects of X-ray contrast media and radiation on human vascular endothelial cells in vitro. Cardiovasc Interv Radiol 12:154–160
39.
Zurück zum Zitat Fauser C, Ullisch EV, Kubler W, Haller C (2001) Differential effects of radiocontrast agents on human umbilical vein endothelial cells: cytotoxicity and modulators of thrombogenicity. Eur J Med Res 6:465–472PubMed Fauser C, Ullisch EV, Kubler W, Haller C (2001) Differential effects of radiocontrast agents on human umbilical vein endothelial cells: cytotoxicity and modulators of thrombogenicity. Eur J Med Res 6:465–472PubMed
40.
Zurück zum Zitat Gabelmann A, Haberstroh J, Weyrich G (2001) Ionic and nonionic contrast agent-mediated endothelial injury. Quantitative analysis of cell proliferation during endothelial repair. Acta Radiol 42:422–425PubMed Gabelmann A, Haberstroh J, Weyrich G (2001) Ionic and nonionic contrast agent-mediated endothelial injury. Quantitative analysis of cell proliferation during endothelial repair. Acta Radiol 42:422–425PubMed
41.
Zurück zum Zitat Sumimura T, Sendo T, Itoh Y, et al (2003) Calcium-dependent injury of human microvascular endothelial cells induced by variety of iodinated radiographic contrast media. Invest Radiol 38:366–374CrossRefPubMed Sumimura T, Sendo T, Itoh Y, et al (2003) Calcium-dependent injury of human microvascular endothelial cells induced by variety of iodinated radiographic contrast media. Invest Radiol 38:366–374CrossRefPubMed
42.
Zurück zum Zitat Zhang H, Holt CM, Malik N, Shepherd L, Morcos SK (2000) Effects of radiographic contrast media on proliferation and apoptosis of human vascular endothelial cells. Br J Radiol 73:1034–1041PubMed Zhang H, Holt CM, Malik N, Shepherd L, Morcos SK (2000) Effects of radiographic contrast media on proliferation and apoptosis of human vascular endothelial cells. Br J Radiol 73:1034–1041PubMed
43.
Zurück zum Zitat Krause W, Niehues D (1996) Biochemical characterization of X-ray contrast media. Invest Radiol 31:30–42CrossRefPubMed Krause W, Niehues D (1996) Biochemical characterization of X-ray contrast media. Invest Radiol 31:30–42CrossRefPubMed
45.
Zurück zum Zitat Nordby A, Thorstensen K, Halgunset J, Haugen OA, Solberg S (1989) Effects on the ATP content of cultured cells after radiographic contrast media exposure—evidence for accumulation of contrast media in cultured cells. Acta Radiol 30:541–547PubMedCrossRef Nordby A, Thorstensen K, Halgunset J, Haugen OA, Solberg S (1989) Effects on the ATP content of cultured cells after radiographic contrast media exposure—evidence for accumulation of contrast media in cultured cells. Acta Radiol 30:541–547PubMedCrossRef
46.
Zurück zum Zitat Morcos SK (2003) Effects of radiographic contrast media on the lung. Br J Radiol 76:290–295CrossRefPubMed Morcos SK (2003) Effects of radiographic contrast media on the lung. Br J Radiol 76:290–295CrossRefPubMed
47.
Zurück zum Zitat Furuta W, Yamauchi A, Dohgu S, et al (2002) Contrast media increase vascular endothelial permeability by inhibiting nitric oxide production. Invest Radiol 37:13–19CrossRefPubMed Furuta W, Yamauchi A, Dohgu S, et al (2002) Contrast media increase vascular endothelial permeability by inhibiting nitric oxide production. Invest Radiol 37:13–19CrossRefPubMed
48.
Zurück zum Zitat Sendo T, Kataoka Y, Takeda Y, Furuta W, Oishi R (2000) Nitric oxide protects against contrast media-induced pulmonary vascular permeability in rats. Invest Radiol 35:472–478CrossRefPubMed Sendo T, Kataoka Y, Takeda Y, Furuta W, Oishi R (2000) Nitric oxide protects against contrast media-induced pulmonary vascular permeability in rats. Invest Radiol 35:472–478CrossRefPubMed
49.
Zurück zum Zitat Tominaga K, Kataoka Y, Sendo T, Furuta W, Niizeki M, Oishi AR (2001) Contrast media-induced pulmonary vascular hyperpermeability is aggravated in a rat climacterium model. Invest Radiol 36:131–135CrossRefPubMed Tominaga K, Kataoka Y, Sendo T, Furuta W, Niizeki M, Oishi AR (2001) Contrast media-induced pulmonary vascular hyperpermeability is aggravated in a rat climacterium model. Invest Radiol 36:131–135CrossRefPubMed
50.
Zurück zum Zitat Furuta W, Sendo T, Kataoka Y, Oishi R (2001) Morphologic degeneration of human microvascular endothelial cells induced by iodinated contrast media. Acad Radiol 8:158–161CrossRefPubMed Furuta W, Sendo T, Kataoka Y, Oishi R (2001) Morphologic degeneration of human microvascular endothelial cells induced by iodinated contrast media. Acad Radiol 8:158–161CrossRefPubMed
51.
Zurück zum Zitat Emery CJ, Fang L, Laude EA, Morcos SK (2001) Effects of radiographic contrast media on pulmonary vascular resistance of normoxic and chronically hypoxic pulmonary hypertensive rats. Br J Radiol 74:1109–1117PubMed Emery CJ, Fang L, Laude EA, Morcos SK (2001) Effects of radiographic contrast media on pulmonary vascular resistance of normoxic and chronically hypoxic pulmonary hypertensive rats. Br J Radiol 74:1109–1117PubMed
52.
Zurück zum Zitat Idee JM, Prigent P, Corot C (2002) Effects of ioxaglate on cultured microvascular endothelial cells: do all in vitro studies actually reflect clinical situations? Acad Radiol 9:98–100CrossRefPubMed Idee JM, Prigent P, Corot C (2002) Effects of ioxaglate on cultured microvascular endothelial cells: do all in vitro studies actually reflect clinical situations? Acad Radiol 9:98–100CrossRefPubMed
53.
Zurück zum Zitat Ferguson JJ, Quinn M, Moake JL (2000) Platelet physiology. In: Ferguson JJ, Chronos NA, Harrington RA (eds) Antiplatelet therapy in clinical practice. Martin Dunitz, London, UK, pp 15–34 Ferguson JJ, Quinn M, Moake JL (2000) Platelet physiology. In: Ferguson JJ, Chronos NA, Harrington RA (eds) Antiplatelet therapy in clinical practice. Martin Dunitz, London, UK, pp 15–34
54.
Zurück zum Zitat Becker RC (2001) Markers of platelet activation and thrombin generation. Cardiovasc Toxicol 1:141–145CrossRefPubMed Becker RC (2001) Markers of platelet activation and thrombin generation. Cardiovasc Toxicol 1:141–145CrossRefPubMed
55.
Zurück zum Zitat Grabowski EF, Rodriquez M, McDonnel SL (1991) Platelet adhesion/aggregation and endothelial cell function in flowing blood: effect of contrast media. Semin Hematol 28:60–65PubMed Grabowski EF, Rodriquez M, McDonnel SL (1991) Platelet adhesion/aggregation and endothelial cell function in flowing blood: effect of contrast media. Semin Hematol 28:60–65PubMed
56.
Zurück zum Zitat Markou CP, Chronos NAF, Hanson SR (2001) Antithromotic effects of ionic and nonionic contrast media in nonhuman primates. Thromb Haemost 85:488–493PubMed Markou CP, Chronos NAF, Hanson SR (2001) Antithromotic effects of ionic and nonionic contrast media in nonhuman primates. Thromb Haemost 85:488–493PubMed
57.
Zurück zum Zitat Li X, Gabriel DA (1997) Differences between contrast media in the inhibition of platelet activation by specific platelet agonists. Acad Radiol 4:108–114CrossRefPubMed Li X, Gabriel DA (1997) Differences between contrast media in the inhibition of platelet activation by specific platelet agonists. Acad Radiol 4:108–114CrossRefPubMed
58.
Zurück zum Zitat Corot C, Chronos N, Sabattier V (1996) In vitro comparison of the effects of contrast media on coagulation and platelet activation. Blood Coagul Fibrinolysis 7:602–608PubMed Corot C, Chronos N, Sabattier V (1996) In vitro comparison of the effects of contrast media on coagulation and platelet activation. Blood Coagul Fibrinolysis 7:602–608PubMed
59.
Zurück zum Zitat Zir LM, Carvalho AC, Hawthorne JW, Colman RW, Lees RS (1974) Effect of contrast agents on platelet aggregation and 14C-serotonin release. N Engl J Med 291:134–135PubMedCrossRef Zir LM, Carvalho AC, Hawthorne JW, Colman RW, Lees RS (1974) Effect of contrast agents on platelet aggregation and 14C-serotonin release. N Engl J Med 291:134–135PubMedCrossRef
60.
Zurück zum Zitat Heptinstall S, White A, Edwards N, et al (1998) Differential effects of three radiographic contrast media on platelet aggregation and degranulation: implications for clinical practice? Br J Haematol 103:1023–1030CrossRefPubMed Heptinstall S, White A, Edwards N, et al (1998) Differential effects of three radiographic contrast media on platelet aggregation and degranulation: implications for clinical practice? Br J Haematol 103:1023–1030CrossRefPubMed
61.
Zurück zum Zitat Eloy R, Corot C, Belleville J (1991) Contrast media for angiography: physicochemical properties, pharmacokinetics and biocompatibility. Clin Mater 7:89–197CrossRefPubMed Eloy R, Corot C, Belleville J (1991) Contrast media for angiography: physicochemical properties, pharmacokinetics and biocompatibility. Clin Mater 7:89–197CrossRefPubMed
62.
Zurück zum Zitat Labarthe B, Idée JM, Burnett R, Corot C (2003) In vivo comparative antithrombotic effect of ioxaglate and iohexol and interaction with the platelet antiaggregant clopidogrel. Invest Radiol 38:34–43CrossRefPubMed Labarthe B, Idée JM, Burnett R, Corot C (2003) In vivo comparative antithrombotic effect of ioxaglate and iohexol and interaction with the platelet antiaggregant clopidogrel. Invest Radiol 38:34–43CrossRefPubMed
63.
Zurück zum Zitat Albanese JR, Venditto JA, Patel GC, Ambrose JA (1995) Effects of ionic and nonionic contrast media on in vitro and in vivo platelet activation. Am J Cardiol 76:1059–1063CrossRefPubMed Albanese JR, Venditto JA, Patel GC, Ambrose JA (1995) Effects of ionic and nonionic contrast media on in vitro and in vivo platelet activation. Am J Cardiol 76:1059–1063CrossRefPubMed
64.
Zurück zum Zitat Arora R, Khandelwal M, Gopal A (1991) In vivo effects of nonionic and ionic contrast media on beta-thromboglobulin and fibrinopeptide levels. J Am Coll Cardiol 17:1533–1536PubMedCrossRef Arora R, Khandelwal M, Gopal A (1991) In vivo effects of nonionic and ionic contrast media on beta-thromboglobulin and fibrinopeptide levels. J Am Coll Cardiol 17:1533–1536PubMedCrossRef
65.
Zurück zum Zitat Brzosko M, Cyrylowski L, Brzosko I, Domanski Z, Fiedorowicz-Fabrycy I (1997) Effects of ionic and nonionic contrast media on platelet function as evaluated by plasma concentration on beta-thromboglobulin. Br J Radiol 70:1239–1244PubMed Brzosko M, Cyrylowski L, Brzosko I, Domanski Z, Fiedorowicz-Fabrycy I (1997) Effects of ionic and nonionic contrast media on platelet function as evaluated by plasma concentration on beta-thromboglobulin. Br J Radiol 70:1239–1244PubMed
66.
Zurück zum Zitat Polanowska R, Wilczynska m, Slawinski W, Goch JH, Augustiniak W, Cierniewski CS (1992) Changes in platelet activity and tissue plasminogen activator during arteriography in patients with chronic limb ischaemia. Thromb Res 65:663–665CrossRefPubMed Polanowska R, Wilczynska m, Slawinski W, Goch JH, Augustiniak W, Cierniewski CS (1992) Changes in platelet activity and tissue plasminogen activator during arteriography in patients with chronic limb ischaemia. Thromb Res 65:663–665CrossRefPubMed
67.
Zurück zum Zitat Jung F, Spitzer SG, Pindur G (2002) Effect of an ionic compared to a nonionic X-ray contrast agent on platelets and coagulation during diagnostic cardiac catheterisation. Pathophysiol Haemost Thromb 32:121–126CrossRefPubMed Jung F, Spitzer SG, Pindur G (2002) Effect of an ionic compared to a nonionic X-ray contrast agent on platelets and coagulation during diagnostic cardiac catheterisation. Pathophysiol Haemost Thromb 32:121–126CrossRefPubMed
68.
Zurück zum Zitat Dalby MCD, Davidson SJ, Burman JF, Clague J, Sigwart U, Davies SW (2002) Systemic platelet effects of contrast media: implications for cardiologic research and clinical practice. Am Heart J 143:E1CrossRefPubMed Dalby MCD, Davidson SJ, Burman JF, Clague J, Sigwart U, Davies SW (2002) Systemic platelet effects of contrast media: implications for cardiologic research and clinical practice. Am Heart J 143:E1CrossRefPubMed
69.
Zurück zum Zitat Stormorken H, Skalpe IO, Testart MC (1986) Effects of various contrast media on coagulation, fibrinolysis and platelet function. An in vitro and in vivo study. Invest Radiol 21:348–354PubMed Stormorken H, Skalpe IO, Testart MC (1986) Effects of various contrast media on coagulation, fibrinolysis and platelet function. An in vitro and in vivo study. Invest Radiol 21:348–354PubMed
70.
Zurück zum Zitat Corot C, Perrin JM, Belleville J, Amiel M, Eloy R (1989) Effect of iodinated contrast media on blood clotting. Invest Radiol 24:390–393PubMed Corot C, Perrin JM, Belleville J, Amiel M, Eloy R (1989) Effect of iodinated contrast media on blood clotting. Invest Radiol 24:390–393PubMed
71.
Zurück zum Zitat Engelhart JA, Smith DC, Maloney MD, Westengard JC, Bull BS (1988) A technique for estimating the probability of clots in blood/contrast agent mixtures. Invest Radiol 23:923–927PubMed Engelhart JA, Smith DC, Maloney MD, Westengard JC, Bull BS (1988) A technique for estimating the probability of clots in blood/contrast agent mixtures. Invest Radiol 23:923–927PubMed
72.
Zurück zum Zitat Grabowski EF, Kaplan KL, Halpern EF (1991) Anticoagulant effects of nonionic versus ionic contrast media in angiography syringes. Invest Radiol 26:417–421PubMed Grabowski EF, Kaplan KL, Halpern EF (1991) Anticoagulant effects of nonionic versus ionic contrast media in angiography syringes. Invest Radiol 26:417–421PubMed
73.
Zurück zum Zitat Parvez Z, Moncada R (1986) Nonionic contrast medium: effects on blood coagulation and complement activation in vitro. Angiology 37:358–364PubMed Parvez Z, Moncada R (1986) Nonionic contrast medium: effects on blood coagulation and complement activation in vitro. Angiology 37:358–364PubMed
74.
Zurück zum Zitat Parvez Z, Vik H (1991) Nonionic contrast media and blood clotting. A critical review. Invest Radiol 26 [Suppl 1]:S103–S106; discussion S107–S109PubMed Parvez Z, Vik H (1991) Nonionic contrast media and blood clotting. A critical review. Invest Radiol 26 [Suppl 1]:S103–S106; discussion S107–S109PubMed
75.
Zurück zum Zitat Rasuli P, McLeish WA, Hammond DI (1989) Anticoagulant effects of contrast materials: in vitro study of iohexol, ioxaglate and diatrizoate. AJR Am J Roentgenol 152:309–311PubMed Rasuli P, McLeish WA, Hammond DI (1989) Anticoagulant effects of contrast materials: in vitro study of iohexol, ioxaglate and diatrizoate. AJR Am J Roentgenol 152:309–311PubMed
76.
Zurück zum Zitat Melton LG, Muga KM, Gabriel DA (1995) Effect of contrast media on in vitro bleeding time: assessment by a hollow fiber instrument. Acad Radiol 2:239–243CrossRefPubMed Melton LG, Muga KM, Gabriel DA (1995) Effect of contrast media on in vitro bleeding time: assessment by a hollow fiber instrument. Acad Radiol 2:239–243CrossRefPubMed
77.
Zurück zum Zitat Fay WP, Parker AC (1998) Effects of radiographic contrast agents on thrombin formation and activity. Thromb Haemost 80:266–272PubMed Fay WP, Parker AC (1998) Effects of radiographic contrast agents on thrombin formation and activity. Thromb Haemost 80:266–272PubMed
78.
Zurück zum Zitat Idée J-M, Corot C (1999) Thrombotic risk associated with use of iodinated contrast media in interventional cardiology: pathophysiology and clinical aspects. Fundam Clin Pharmacol 13:613–623PubMedCrossRef Idée J-M, Corot C (1999) Thrombotic risk associated with use of iodinated contrast media in interventional cardiology: pathophysiology and clinical aspects. Fundam Clin Pharmacol 13:613–623PubMedCrossRef
79.
Zurück zum Zitat Dawson P, Hawitt P, Mackle IJ, Machin SJ, Amin S, Bradshaw A (1986) Contrast, coagulation and fibrinolysis. Invest Radiol 21:248–252PubMed Dawson P, Hawitt P, Mackle IJ, Machin SJ, Amin S, Bradshaw A (1986) Contrast, coagulation and fibrinolysis. Invest Radiol 21:248–252PubMed
80.
Zurück zum Zitat Dawson P (1999) Contrast media interactions with endothelium and the blood. In: Dawson P, Cosgrove DO, Grainger RG (eds) Textbook of contrast media, Martin Dunitz, London, pp 191–209 Dawson P (1999) Contrast media interactions with endothelium and the blood. In: Dawson P, Cosgrove DO, Grainger RG (eds) Textbook of contrast media, Martin Dunitz, London, pp 191–209
81.
Zurück zum Zitat Al Dieri R, Beguin S, Hemker C (2003) The ionic contrast medium ioxaglate interferes with thrombin-mediated feedback activation of factor V, factor VIII and platelets. J Thromb Haemost 1:269–274CrossRefPubMed Al Dieri R, Beguin S, Hemker C (2003) The ionic contrast medium ioxaglate interferes with thrombin-mediated feedback activation of factor V, factor VIII and platelets. J Thromb Haemost 1:269–274CrossRefPubMed
82.
Zurück zum Zitat Al Dieri R, de Muinck E, Hemker C, Beguin S (2001) An ionic contrast agent inhibits platelet-dependent thrombin generation and boots the effect of abciximab. Thromb Haemost 85:944–945PubMed Al Dieri R, de Muinck E, Hemker C, Beguin S (2001) An ionic contrast agent inhibits platelet-dependent thrombin generation and boots the effect of abciximab. Thromb Haemost 85:944–945PubMed
83.
Zurück zum Zitat Robertson HJF (1987) Blood clot formation in angiographic syringes containing nonionic contrast media. Radiology 163:621–622 Robertson HJF (1987) Blood clot formation in angiographic syringes containing nonionic contrast media. Radiology 163:621–622
84.
Zurück zum Zitat Bashore TM, Davidson CK, Mark DB (1988) Iopamidol use in the cardiac catheterization laboratory: a retrospective analysis of 3313 patients. Cardiology 5:60–100 Bashore TM, Davidson CK, Mark DB (1988) Iopamidol use in the cardiac catheterization laboratory: a retrospective analysis of 3313 patients. Cardiology 5:60–100
85.
Zurück zum Zitat Grollman JH Jr, Liu CK, Astone RA, Lurie MD (1988) Thromboembolic complications in coronary angiography associated with the use of nonionic contrast medium. Catheter Cardiovasc Diagn 14:159–164 Grollman JH Jr, Liu CK, Astone RA, Lurie MD (1988) Thromboembolic complications in coronary angiography associated with the use of nonionic contrast medium. Catheter Cardiovasc Diagn 14:159–164
86.
Zurück zum Zitat Millet PJ, Sestier F (1989) Thromboembolic complications with nonionic contrast media. Catheter Cardiovasc Diagn 17:192 Millet PJ, Sestier F (1989) Thromboembolic complications with nonionic contrast media. Catheter Cardiovasc Diagn 17:192
87.
Zurück zum Zitat Davidson CJ, Mark DB, Pieper KS, et al (1990) Thrombotic and cardiovascular complications related to nonionic contrast media during cardiac catheterization: analysis of 8517 patients. Am J Cardiol 65:1481–1484CrossRefPubMed Davidson CJ, Mark DB, Pieper KS, et al (1990) Thrombotic and cardiovascular complications related to nonionic contrast media during cardiac catheterization: analysis of 8517 patients. Am J Cardiol 65:1481–1484CrossRefPubMed
88.
Zurück zum Zitat Schrader R (1996) Thrombogenic potential of nonionic contrast media, fact or fiction? Eur J Radiol 23 [Suppl 1]:S10–S13PubMed Schrader R (1996) Thrombogenic potential of nonionic contrast media, fact or fiction? Eur J Radiol 23 [Suppl 1]:S10–S13PubMed
89.
Zurück zum Zitat Piessens JH, Stammen F, Vrolix MC, et al (1993) Effects of an ionic versus a nonionic low osmolar contrast agent on the thrombotic complications of coronary angioplasty. Catheter Cardiovasc Diagn 28:99–105 Piessens JH, Stammen F, Vrolix MC, et al (1993) Effects of an ionic versus a nonionic low osmolar contrast agent on the thrombotic complications of coronary angioplasty. Catheter Cardiovasc Diagn 28:99–105
90.
Zurück zum Zitat Grines CL, Schreiber TL, Savas V, et al (1996) A randomized trial of low osmolar ionic versus nonionic contrast media in patients with myocardial infarction or unstable angina undergoing percutaneous transluminal coronary angioplasty. J Am Coll Cardiol 27:1381–1386CrossRefPubMed Grines CL, Schreiber TL, Savas V, et al (1996) A randomized trial of low osmolar ionic versus nonionic contrast media in patients with myocardial infarction or unstable angina undergoing percutaneous transluminal coronary angioplasty. J Am Coll Cardiol 27:1381–1386CrossRefPubMed
91.
Zurück zum Zitat Esplugas E, Cequier A, Jara F, et al (1991) Risk of thrombosis during coronary angioplasty with low osmolality contrast media. Am J Cardiol 68:1020–1024CrossRefPubMed Esplugas E, Cequier A, Jara F, et al (1991) Risk of thrombosis during coronary angioplasty with low osmolality contrast media. Am J Cardiol 68:1020–1024CrossRefPubMed
92.
Zurück zum Zitat Malekianpour M, Bonan R, Lespérance J, Gosselin G, Hudon G, Doucet S (1998) Comparison of ionic and nonionic low osmolar contrast media in relation to thrombotic complications of angioplasty in patients with unstable angina. Am Heart J 135:1067–1075CrossRefPubMed Malekianpour M, Bonan R, Lespérance J, Gosselin G, Hudon G, Doucet S (1998) Comparison of ionic and nonionic low osmolar contrast media in relation to thrombotic complications of angioplasty in patients with unstable angina. Am Heart J 135:1067–1075CrossRefPubMed
93.
Zurück zum Zitat Schrader R, Esch I, Ensslen R, et al (1999) A randomized trial comparing the impact of a nonionic (iomeprol) versus an ionic (ioxaglate) low osmolar contrast medium on abrupt vessel closure and ischaemic complications after coronary angioplasty. J Am Coll Cardiol 33:395–402CrossRefPubMed Schrader R, Esch I, Ensslen R, et al (1999) A randomized trial comparing the impact of a nonionic (iomeprol) versus an ionic (ioxaglate) low osmolar contrast medium on abrupt vessel closure and ischaemic complications after coronary angioplasty. J Am Coll Cardiol 33:395–402CrossRefPubMed
94.
Zurück zum Zitat Fleisch M, Mulhauser B, Garachemani A, et al (1999) Impact of ionic (ioxaglate) and nonionic (ioversol) contrast media on PTCA-related complications. J Am Coll Cardiol 33 [Suppl A]:85A; abstract 1188–1192 Fleisch M, Mulhauser B, Garachemani A, et al (1999) Impact of ionic (ioxaglate) and nonionic (ioversol) contrast media on PTCA-related complications. J Am Coll Cardiol 33 [Suppl A]:85A; abstract 1188–1192
95.
Zurück zum Zitat Danzi GB, Capuano C, Sesana M, Predolini S, Baglini R (2003) Nonionic low-osmolar contrast media have no impact on major adverse cardiac events in patients undergoing coronary stenting with appropriate antiplatelet therapy. Catheter Cardiovasc Interv 60:477–482CrossRefPubMed Danzi GB, Capuano C, Sesana M, Predolini S, Baglini R (2003) Nonionic low-osmolar contrast media have no impact on major adverse cardiac events in patients undergoing coronary stenting with appropriate antiplatelet therapy. Catheter Cardiovasc Interv 60:477–482CrossRefPubMed
96.
Zurück zum Zitat Scheller B, Hennen B, Pohl A, Schieffer H, Markwirth T (2001) Acute and subacute stent occlusion: risk reduction by ionic contrast media. Eur Heart J 22:385–391CrossRefPubMed Scheller B, Hennen B, Pohl A, Schieffer H, Markwirth T (2001) Acute and subacute stent occlusion: risk reduction by ionic contrast media. Eur Heart J 22:385–391CrossRefPubMed
97.
Zurück zum Zitat Cucherat M, Leizorovicz A (1999) Effects of nonionic contrast media on abrupt vessel closure and ischaemic complications after angioplasty. A meta-analysis. Am J Cardiol [Suppl] 84:98P Cucherat M, Leizorovicz A (1999) Effects of nonionic contrast media on abrupt vessel closure and ischaemic complications after angioplasty. A meta-analysis. Am J Cardiol [Suppl] 84:98P
98.
Zurück zum Zitat Bertrand ME, Esplugas E, Piessens J, Rasch W (2000) Influence of a nonionic, iso-osmolar contrast medium (iodixanol) versus an ionic, low-osmolar contrast medium (ioxaglate) on major adverse cardiac events in patients undergoing percutaneous transluminal coronary angioplasty: a multicenter, randomized, double-blind study. Visipaque in percutaneous transluminal coronary angioplasty VIP Trial Investigators. Circulation 101:131–136PubMed Bertrand ME, Esplugas E, Piessens J, Rasch W (2000) Influence of a nonionic, iso-osmolar contrast medium (iodixanol) versus an ionic, low-osmolar contrast medium (ioxaglate) on major adverse cardiac events in patients undergoing percutaneous transluminal coronary angioplasty: a multicenter, randomized, double-blind study. Visipaque in percutaneous transluminal coronary angioplasty VIP Trial Investigators. Circulation 101:131–136PubMed
99.
Zurück zum Zitat Davidson CJ, Laskey WK, Hermiller JB, et al (2000) Randomized trial of contrast media utilization in high-risk PTCA. The COURT trial. Circulation 101:2172–2177PubMed Davidson CJ, Laskey WK, Hermiller JB, et al (2000) Randomized trial of contrast media utilization in high-risk PTCA. The COURT trial. Circulation 101:2172–2177PubMed
100.
Zurück zum Zitat Sutton AGC, Ashton VJ, Campbell PG, Price DJA, Hall JA, de Belder MA (2002) A randomized prospective trial of ioxaglate 320 (Hexabrix) vs iodixanol 320 (Visipaque) in patients undergoing percutaneous coronary intervention. Catheter Cardiovasc Interv 57:346–352CrossRefPubMed Sutton AGC, Ashton VJ, Campbell PG, Price DJA, Hall JA, de Belder MA (2002) A randomized prospective trial of ioxaglate 320 (Hexabrix) vs iodixanol 320 (Visipaque) in patients undergoing percutaneous coronary intervention. Catheter Cardiovasc Interv 57:346–352CrossRefPubMed
101.
Zurück zum Zitat Dehmer GJ, Gresalfi N, Daly D, Oberhardt B, Tate DA (1995) Impairment of fibrinolysis by streptokinase, urokinase and recombinant tissue-type plasminogen activator in the presence of radiographic contrast agents. J Am Coll Cardiol 25:1069–1075CrossRefPubMed Dehmer GJ, Gresalfi N, Daly D, Oberhardt B, Tate DA (1995) Impairment of fibrinolysis by streptokinase, urokinase and recombinant tissue-type plasminogen activator in the presence of radiographic contrast agents. J Am Coll Cardiol 25:1069–1075CrossRefPubMed
102.
Zurück zum Zitat Gabriel DA, Jones MR, Reece NS, Boothroyd E, Bashore T (1991) Platelet and fibrin modification by radiographic contrast media. Circ Res 68:881–887PubMed Gabriel DA, Jones MR, Reece NS, Boothroyd E, Bashore T (1991) Platelet and fibrin modification by radiographic contrast media. Circ Res 68:881–887PubMed
103.
Zurück zum Zitat Parvez Z, Moncada R, Messmore HL, Fareed J (1982) Ionic and nonionic contrast media interaction with anticoagulant drugs. Acta Radiol Diagn (Stockh) 23:401–404 Parvez Z, Moncada R, Messmore HL, Fareed J (1982) Ionic and nonionic contrast media interaction with anticoagulant drugs. Acta Radiol Diagn (Stockh) 23:401–404
104.
Zurück zum Zitat Jones CI, Goodal AH (2003) Differential effects of the iodinated contrast agents ioxaglate, iohexol and iodixanol on thrombus formation and fibrinolysis. Thromb Res 112:65–71CrossRefPubMed Jones CI, Goodal AH (2003) Differential effects of the iodinated contrast agents ioxaglate, iohexol and iodixanol on thrombus formation and fibrinolysis. Thromb Res 112:65–71CrossRefPubMed
105.
Zurück zum Zitat Pislaru S, Pislaru C, Szilard M, Arnout J, van der Werf F (1998) In vivo effects of contrast media on coronary thrombolysis. J Am Coll Cardiol 32:1102–1108CrossRefPubMed Pislaru S, Pislaru C, Szilard M, Arnout J, van der Werf F (1998) In vivo effects of contrast media on coronary thrombolysis. J Am Coll Cardiol 32:1102–1108CrossRefPubMed
106.
Zurück zum Zitat Van Beek EJR, Levi M, Reekers JA, Hack CE, Buller HR, Ten Cate JW (1994) Increased plasma levels of PAI-1 after administration of nonionic contrast medium in patients undergoing pulmonary angiography. Radiology 193:821–823PubMed Van Beek EJR, Levi M, Reekers JA, Hack CE, Buller HR, Ten Cate JW (1994) Increased plasma levels of PAI-1 after administration of nonionic contrast medium in patients undergoing pulmonary angiography. Radiology 193:821–823PubMed
107.
Zurück zum Zitat Morcos SK, Thomsen HS, Exley CM, Members of the Contrast Media Safety Committee of the European Society of Urogenital Radiology (ESUR) (2005) Contrast media: interaction with other drugs and clinical tests. Eur Radiol 15:1463–1468CrossRefPubMed Morcos SK, Thomsen HS, Exley CM, Members of the Contrast Media Safety Committee of the European Society of Urogenital Radiology (ESUR) (2005) Contrast media: interaction with other drugs and clinical tests. Eur Radiol 15:1463–1468CrossRefPubMed
108.
Zurück zum Zitat Aguirre FV, Simoons ML, Ferguson JJ, et al (1997) Impact of contrast media on clinical outcomes following percutaneous coronary interventions with platelet glycoprotein IIb/IIIa inhibition: meta-analysis of clinical trials with abciximab. Circulation 96 [Suppl 1]:161 Aguirre FV, Simoons ML, Ferguson JJ, et al (1997) Impact of contrast media on clinical outcomes following percutaneous coronary interventions with platelet glycoprotein IIb/IIIa inhibition: meta-analysis of clinical trials with abciximab. Circulation 96 [Suppl 1]:161
Metadaten
Titel
Effects of iodinated contrast media on blood and endothelium
verfasst von
Peter Aspelin
Fulvio Stacul
Henrik S. Thomsen
Sameh K. Morcos
Aart J. van der Molen
Members of the Contrast Media Safety Committee of the European Society of Urogenital Radiology (ESUR)
Publikationsdatum
01.05.2006
Verlag
Springer-Verlag
Erschienen in
European Radiology / Ausgabe 5/2006
Print ISSN: 0938-7994
Elektronische ISSN: 1432-1084
DOI
https://doi.org/10.1007/s00330-005-0081-5

Weitere Artikel der Ausgabe 5/2006

European Radiology 5/2006 Zur Ausgabe

News From The Efomp

EFOMP News

Update Radiologie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.