Influence of cardiac hemodynamic parameters on coronary artery opacification with 64-slice computed tomography

verfasst von: Lars Husmann, Hatem Alkadhi, Thomas Boehm, Sebastian Leschka, Tiziano Schepis, Pascal Koepfli, Lotus Desbiolles, Borut Marincek, Philipp A. Kaufmann, Simon Wildermuth

Erschienen in: European Radiology | Ausgabe 5/2006

Einloggen, um Zugang zu erhalten

Abstract

The purpose of this study was to evaluate the influence of ejection fraction (EF), stroke volume (SV), heart rate, and cardiac output (CO) on coronary artery opacification with 64-slice computed tomography (CT). Sixty patients underwent, retrospectively, electrocardiography-gated 64-slice CT coronary angiography. Left ventricular EF, SV, and CO were calculated with semi-automated software. Attenuation values were measured and contrast-to-noise ratios (CNRs) were calculated in the proximal right coronary artery (RCA) and left main artery (LMA). Mean EF during scanning was 61.5±12.4%, SV was 63.2±15.6 ml, heart rate was 62.5±11.8 beats per minute (bpm), and CO was 3.88±1.06 l/min. There was no significant correlation between the EF and heart rate and the attenuation and CNR in either coronary artery. A significant negative correlation was found in both arteries between SV and attenuation (RCA r=−0.26, P<0.05; LMA r=−0.34, P<0.01) and between SV and CNR (RCA r=−0.26, P<0.05; LMA r=−0.26, P<0.05). Similarly, a significant negative correlation was found between the CO and attenuation (RCA r=−0.42, P<0.05; LMA r=−0.56, P<0.001) and between the CO and CNR (RCA r=−0.39, P<0.05; LMA r=−0.44, P<0.001). The actual hemodynamic status of the patient influences the coronary artery opacification with 64-slice CT, in that vessel opacification decreases as SV and CO increase.
Literatur
1.
Zurück zum Zitat Leschka S et al (2005) Accuracy of MSCT coronary angiography with 64-slice technology: first experience. Eur Heart J 26:1482–1487PubMedCrossRef Leschka S et al (2005) Accuracy of MSCT coronary angiography with 64-slice technology: first experience. Eur Heart J 26:1482–1487PubMedCrossRef
2.
Zurück zum Zitat Raff GL, Gallagher MJ, O’Neill WW, Goldstein JA (2005) Diagnostic accuracy of noninvasive coronary angiography using 64-slice spiral computed tomography. J Am Coll Cardiol 46:552–557PubMedCrossRef Raff GL, Gallagher MJ, O’Neill WW, Goldstein JA (2005) Diagnostic accuracy of noninvasive coronary angiography using 64-slice spiral computed tomography. J Am Coll Cardiol 46:552–557PubMedCrossRef
3.
Zurück zum Zitat Flohr T, Stierstorfer K, Raupach R, Ulzheimer S, Bruder H (2004) Performance evaluation of a 64-slice CT system with z-flying focal spot. Rofo Fortschr Geb Rontgenstr Neuen BildgebVerfahr 176:1803–1810CrossRef Flohr T, Stierstorfer K, Raupach R, Ulzheimer S, Bruder H (2004) Performance evaluation of a 64-slice CT system with z-flying focal spot. Rofo Fortschr Geb Rontgenstr Neuen BildgebVerfahr 176:1803–1810CrossRef
4.
Zurück zum Zitat Hoffmann MH et al (2005) Noninvasive coronary angiography with 16-detector row CT: effect of heart rate. Radiology 234:86–97PubMedCrossRef Hoffmann MH et al (2005) Noninvasive coronary angiography with 16-detector row CT: effect of heart rate. Radiology 234:86–97PubMedCrossRef
5.
Zurück zum Zitat Zhang SZ, Hu XH, Zhang QW, Huang WX (2005) Evaluation of computed tomography coronary angiography in patients with a high heart rate using 16-slice spiral computed tomography with 0.37-s gantry rotation time. Eur Radiol 15:1105–1109CrossRefPubMed Zhang SZ, Hu XH, Zhang QW, Huang WX (2005) Evaluation of computed tomography coronary angiography in patients with a high heart rate using 16-slice spiral computed tomography with 0.37-s gantry rotation time. Eur Radiol 15:1105–1109CrossRefPubMed
6.
Zurück zum Zitat Hamoir XL, et al (2005) Coronary arteries: assessment of image quality and optimal reconstruction window in retrospective ECG-gated multislice CT at 375-ms gantry rotation time. Eur Radiol 15:296–304CrossRefPubMed Hamoir XL, et al (2005) Coronary arteries: assessment of image quality and optimal reconstruction window in retrospective ECG-gated multislice CT at 375-ms gantry rotation time. Eur Radiol 15:296–304CrossRefPubMed
7.
Zurück zum Zitat Nieman K, et al (2002) Non-invasive coronary angiography with multislice spiral computed tomography: impact of heart rate. Heart 88:470–474CrossRefPubMed Nieman K, et al (2002) Non-invasive coronary angiography with multislice spiral computed tomography: impact of heart rate. Heart 88:470–474CrossRefPubMed
8.
Zurück zum Zitat Stanford W, Burns TL, Thompson BH, Witt JD, Lauer RM, Mahoney LT (2004) Influence of body size and section level on calcium phantom measurements at coronary artery calcium CT scanning. Radiology 230:198–205PubMedCrossRef Stanford W, Burns TL, Thompson BH, Witt JD, Lauer RM, Mahoney LT (2004) Influence of body size and section level on calcium phantom measurements at coronary artery calcium CT scanning. Radiology 230:198–205PubMedCrossRef
9.
Zurück zum Zitat Choi HS, et al (2004) Pitfalls, artifacts, and remedies in multi- detector row CT coronary angiography. Radiographics 24:787–800PubMedCrossRef Choi HS, et al (2004) Pitfalls, artifacts, and remedies in multi- detector row CT coronary angiography. Radiographics 24:787–800PubMedCrossRef
10.
Zurück zum Zitat Kopp AF, et al (2001) Coronary arteries: retrospectively ECG-gated multi-detector row CT angiography with selective optimization of the image reconstruction window. Radiology 221:683–688PubMedCrossRef Kopp AF, et al (2001) Coronary arteries: retrospectively ECG-gated multi-detector row CT angiography with selective optimization of the image reconstruction window. Radiology 221:683–688PubMedCrossRef
11.
Zurück zum Zitat Cademartiri F, et al (2005) Intravenous contrast material administration at helical 16-detector row CT coronary angiography: effect of iodine concentration on vascular attenuation. Radiology 236:661–665PubMedCrossRef Cademartiri F, et al (2005) Intravenous contrast material administration at helical 16-detector row CT coronary angiography: effect of iodine concentration on vascular attenuation. Radiology 236:661–665PubMedCrossRef
12.
Zurück zum Zitat Cademartiri F, et al (2004) Intravenous contrast material administration at 16-detector row helical CT coronary angiography: test bolus versus bolus-tracking technique. Radiology 233:817–823PubMedCrossRef Cademartiri F, et al (2004) Intravenous contrast material administration at 16-detector row helical CT coronary angiography: test bolus versus bolus-tracking technique. Radiology 233:817–823PubMedCrossRef
13.
Zurück zum Zitat Cademartiri F, van der Lugt A, Luccichenti G, Pavone P, Krestin GP (2002) Parameters affecting bolus geometry in CTA: a review. J Comput Assist Tomogr 26:598–607CrossRefPubMed Cademartiri F, van der Lugt A, Luccichenti G, Pavone P, Krestin GP (2002) Parameters affecting bolus geometry in CTA: a review. J Comput Assist Tomogr 26:598–607CrossRefPubMed
14.
Zurück zum Zitat Bae KT, Heiken JP, Brink JA (1998) Aortic and hepatic contrast medium enhancement at CT. Part II. Effect of reduced cardiac output in a porcine model. Radiology 207:657–662PubMed Bae KT, Heiken JP, Brink JA (1998) Aortic and hepatic contrast medium enhancement at CT. Part II. Effect of reduced cardiac output in a porcine model. Radiology 207:657–662PubMed
15.
Zurück zum Zitat Sivit CJ, Taylor GA, Bulas DI, Kushner DC, Potter BM, Eichelberger MR (1992) Posttraumatic shock in children: CT findings associated with hemodynamic instability. Radiology 182:723–726PubMed Sivit CJ, Taylor GA, Bulas DI, Kushner DC, Potter BM, Eichelberger MR (1992) Posttraumatic shock in children: CT findings associated with hemodynamic instability. Radiology 182:723–726PubMed
16.
Zurück zum Zitat Becker CR, et al (2003) Optimal contrast application for cardiac 4-detector-row computed tomography. Invest Radiol 38:690–694PubMedCrossRef Becker CR, et al (2003) Optimal contrast application for cardiac 4-detector-row computed tomography. Invest Radiol 38:690–694PubMedCrossRef
17.
Zurück zum Zitat Flohr T, Ohnesorge B (2001) Heart rate adaptive optimization of spatial and temporal resolution for electrocardiogram-gated multislice spiral CT of the heart. J Comput Assist Tomogr 25:907–923CrossRefPubMed Flohr T, Ohnesorge B (2001) Heart rate adaptive optimization of spatial and temporal resolution for electrocardiogram-gated multislice spiral CT of the heart. J Comput Assist Tomogr 25:907–923CrossRefPubMed
18.
Zurück zum Zitat Juergens KU, et al (2004) Multi-detector row CT of left ventricular function with dedicated analysis software versus MR imaging: initial experience. Radiology 230:403–410PubMedCrossRef Juergens KU, et al (2004) Multi-detector row CT of left ventricular function with dedicated analysis software versus MR imaging: initial experience. Radiology 230:403–410PubMedCrossRef
19.
Zurück zum Zitat Boehm T, et al (2004) Time-effectiveness, observer-dependence, and accuracy of measurements of left ventricular ejection fraction using 4-channel MDCT. Rofo Fortschr Geb Rontgenstr Neuen BildgebVerfahr 176:529–537CrossRef Boehm T, et al (2004) Time-effectiveness, observer-dependence, and accuracy of measurements of left ventricular ejection fraction using 4-channel MDCT. Rofo Fortschr Geb Rontgenstr Neuen BildgebVerfahr 176:529–537CrossRef
20.
Zurück zum Zitat Juergens KU, Fischbach R (2005) Left ventricular function studied with MDCT. Eur Radiol DOI 10.1007/s00330-005-2888-5 Juergens KU, Fischbach R (2005) Left ventricular function studied with MDCT. Eur Radiol DOI 10.1007/s00330-005-2888-5
21.
Zurück zum Zitat Lembcke A, et al (2004) Image quality of noninvasive coronary angiography using multislice spiral computed tomography and electron-beam computed tomography: intraindividual comparison in an animal model. Invest Radiol 39:357–364CrossRefPubMed Lembcke A, et al (2004) Image quality of noninvasive coronary angiography using multislice spiral computed tomography and electron-beam computed tomography: intraindividual comparison in an animal model. Invest Radiol 39:357–364CrossRefPubMed
22.
Zurück zum Zitat Achenbach S, et al (2003) Comparison of image quality in contrast-enhanced coronary-artery visualization by electron beam tomography and retrospectively electrocardiogram-gated multislice spiral computed tomography. Invest Radiol 38:119–128CrossRefPubMed Achenbach S, et al (2003) Comparison of image quality in contrast-enhanced coronary-artery visualization by electron beam tomography and retrospectively electrocardiogram-gated multislice spiral computed tomography. Invest Radiol 38:119–128CrossRefPubMed
23.
Zurück zum Zitat Anand IS, Florea VG (2001) High output cardiac failure. Curr Treat Options Cardiovasc Med 3:151–159PubMedCrossRef Anand IS, Florea VG (2001) High output cardiac failure. Curr Treat Options Cardiovasc Med 3:151–159PubMedCrossRef
24.
Zurück zum Zitat Fleischmann D, Rubin GD, Bankier AA, Hittmair K (2000) Improved uniformity of aortic enhancement with customized contrast medium injection protocols at CT angiography. Radiology 214:363–371PubMed Fleischmann D, Rubin GD, Bankier AA, Hittmair K (2000) Improved uniformity of aortic enhancement with customized contrast medium injection protocols at CT angiography. Radiology 214:363–371PubMed
25.
Zurück zum Zitat Salm LP, et al (2005) Global and regional left ventricular function assessment with 16-detector row CT: Comparison with echocardiography and cardiovascular magnetic resonance. Eur J Echocardiogr (in press) Salm LP, et al (2005) Global and regional left ventricular function assessment with 16-detector row CT: Comparison with echocardiography and cardiovascular magnetic resonance. Eur J Echocardiogr (in press)
26.
Zurück zum Zitat Mahnken AH, et al (2003) Measurement of cardiac output from a test-bolus injection in multislice computed tomography. Eur Radiol 13:2498–2504CrossRefPubMed Mahnken AH, et al (2003) Measurement of cardiac output from a test-bolus injection in multislice computed tomography. Eur Radiol 13:2498–2504CrossRefPubMed
Metadaten
Titel
Influence of cardiac hemodynamic parameters on coronary artery opacification with 64-slice computed tomography
verfasst von
Lars Husmann
Hatem Alkadhi
Thomas Boehm
Sebastian Leschka
Tiziano Schepis
Pascal Koepfli
Lotus Desbiolles
Borut Marincek
Philipp A. Kaufmann
Simon Wildermuth
Publikationsdatum
01.05.2006
Verlag
Springer-Verlag
Erschienen in
European Radiology / Ausgabe 5/2006
Print ISSN: 0938-7994
Elektronische ISSN: 1432-1084
DOI
https://doi.org/10.1007/s00330-005-0110-4

Weitere Artikel der Ausgabe 5/2006

European Radiology 5/2006 Zur Ausgabe

Letter to the Editor

Author's reply

Update Radiologie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.