Skip to main content
Erschienen in: European Radiology 2/2006

01.02.2006 | Urogenital

MR-guided biopsies of lesions in the retroperitoneal space: technique and results

verfasst von: S. Zangos, K. Eichler, A. Wetter, T. Lehnert, R. Hammerstingl, T. Diebold, P. Reichel, C. Herzog, M.-L. Hansmann, M. G. Mack, T. J. Vogl

Erschienen in: European Radiology | Ausgabe 2/2006

Einloggen, um Zugang zu erhalten

Abstract

The purpose of this study was to evaluate the safety and precision of MRI-guided biopsies of retroperitoneal space-occupying tumors in an open low-field system. In 30 patients with indistinct retroperitoneal tumors [paraaortic lesion (n=20), kidney (n=2), suprarenal gland (n=3) and pancreas (n=5)] MR-guided biopsies were performed using a low-field system (0.2 T, Magnetom Concerto, Siemens, Germany). For the monitoring of the biopsies T1-weighted FLASH sequences (TR/TE=160/5 ms; 90°) were used in all patients and modified FLASH sequences (TR/TE=160/13 ms; 90°) in ten patients. After positioning of the needle in the tumors 114 biopsy specimens were acquired in coaxial technique with 16-gauge cutting needles (Somatex, Germany). The biopsies were successfully performed in all patients without vascular or organ injuries. The visualization of the aortic blood flow with MRI facilitated the biopsy procedures of paraaortic lesions. The size of the lesions ranged from 1.6 to 7.5 cm. The median distance of the biopsy access path was 10.4 cm. Adequate specimens were obtained in 28 cases (93.3%) resulting in a correct histological classification of 27 lesions (90%). In conclusion, MR-guided biopsies of retroperitoneal lesions using an open low-field system can be performed safely and accurately and is an alternative to CT-guided biopsies.
Literatur
1.
Zurück zum Zitat Bellin MF, Roy C, Kinkel K et al (1998) Lymph node metastases: safety and effectiveness of MR imaging with ultrasmall superparamagnetic iron oxide particles-initial clinical experience. Radiology 207:799–808PubMed Bellin MF, Roy C, Kinkel K et al (1998) Lymph node metastases: safety and effectiveness of MR imaging with ultrasmall superparamagnetic iron oxide particles-initial clinical experience. Radiology 207:799–808PubMed
2.
Zurück zum Zitat Hopper K (1995) Percutaneous, radiographically guided biopsy: a history. Radiology 196:329–333PubMed Hopper K (1995) Percutaneous, radiographically guided biopsy: a history. Radiology 196:329–333PubMed
3.
Zurück zum Zitat Sheafor DH, Paulson EK, Simmons CM, DeLong DM, Nelson RC (1998) Abdominal percutaneous interventional procedures: comparison of CT and US guidance. Radiology 207:705–710PubMed Sheafor DH, Paulson EK, Simmons CM, DeLong DM, Nelson RC (1998) Abdominal percutaneous interventional procedures: comparison of CT and US guidance. Radiology 207:705–710PubMed
4.
Zurück zum Zitat Schulz T, Puccini S, Schneider J, Kahn T (2004) Interventional and intraoperative MR: review and update of techniques and clinical experience. Eur Radiol 14:2212–2227CrossRefPubMed Schulz T, Puccini S, Schneider J, Kahn T (2004) Interventional and intraoperative MR: review and update of techniques and clinical experience. Eur Radiol 14:2212–2227CrossRefPubMed
5.
Zurück zum Zitat Zangos S, Kiefl D, Eichler K, Engelmann K, Heller M, Herzog C, Mack MG, Jacobi V, Vogl TJ (2003) MR-guided biopsies of undetermined liver lesions: technique and results. Rofo Fortschr Geb Rontgenstr Neuen Bildgeb Verfahr 175:688–694CrossRefPubMed Zangos S, Kiefl D, Eichler K, Engelmann K, Heller M, Herzog C, Mack MG, Jacobi V, Vogl TJ (2003) MR-guided biopsies of undetermined liver lesions: technique and results. Rofo Fortschr Geb Rontgenstr Neuen Bildgeb Verfahr 175:688–694CrossRefPubMed
6.
Zurück zum Zitat Sofocleous C, Schubert J, Brown K, Brody L, Covey A, Getrajdman G (2004) CT-guided transvenous or transcaval needle biopsy of pancreatic and peripancreatic lesions. J Vasc Interv Radiol 15:1099–1104PubMed Sofocleous C, Schubert J, Brown K, Brody L, Covey A, Getrajdman G (2004) CT-guided transvenous or transcaval needle biopsy of pancreatic and peripancreatic lesions. J Vasc Interv Radiol 15:1099–1104PubMed
7.
Zurück zum Zitat Wutke R, Schmid A, Fellner F, Horbach T, Kastl S, Papadopoulos T, Hohenberger W, Bautz W (2001) CT-guided percutaneous core biopsy: effective accuracy, diagnostic utility and effective costs. Rofo Fortschr Geb Rontgenstr Neuen Bildgeb Verfahr 173:1025–1033CrossRefPubMed Wutke R, Schmid A, Fellner F, Horbach T, Kastl S, Papadopoulos T, Hohenberger W, Bautz W (2001) CT-guided percutaneous core biopsy: effective accuracy, diagnostic utility and effective costs. Rofo Fortschr Geb Rontgenstr Neuen Bildgeb Verfahr 173:1025–1033CrossRefPubMed
8.
Zurück zum Zitat Harisinghani MG, Saini S, Weissleder R, Hahn PF, Yantiss RK, Tempany C, Wood BJ, Mueller PR (1999) MR lymphangiography using ultrasmall superparamagnetic iron oxide in patients with primary abdominal and pelvic malignancies: radiographic-pathologic correlation. AJR Am J Roentgenol 172:1347–1351PubMed Harisinghani MG, Saini S, Weissleder R, Hahn PF, Yantiss RK, Tempany C, Wood BJ, Mueller PR (1999) MR lymphangiography using ultrasmall superparamagnetic iron oxide in patients with primary abdominal and pelvic malignancies: radiographic-pathologic correlation. AJR Am J Roentgenol 172:1347–1351PubMed
9.
Zurück zum Zitat Matalon TA, Silver B (1990) US guidance of interventional procedures. Radiology 174:43–47PubMed Matalon TA, Silver B (1990) US guidance of interventional procedures. Radiology 174:43–47PubMed
10.
Zurück zum Zitat Charboneau JW, Reading CC, Welch TJ (1990) CT and sonographically guided needle biopsy: current techniques and new innovations. AJR Am J Roentgenol 154:1–10PubMed Charboneau JW, Reading CC, Welch TJ (1990) CT and sonographically guided needle biopsy: current techniques and new innovations. AJR Am J Roentgenol 154:1–10PubMed
11.
Zurück zum Zitat Dupuy DE, Rosenberg AE, Punyaratabandhu T, Tan MH, Mankin HJ (1998) Accuracy of CT-guided needle biopsy of musculoskeletal neoplasms. AJR Am J Roentgenol 171:759–762PubMed Dupuy DE, Rosenberg AE, Punyaratabandhu T, Tan MH, Mankin HJ (1998) Accuracy of CT-guided needle biopsy of musculoskeletal neoplasms. AJR Am J Roentgenol 171:759–762PubMed
12.
Zurück zum Zitat Zangos S, Eichler K, Engelmann K et al (2004) MR-guided transgluteal biopsies with an open low-field system in patients with clinically suspected prostate cancer: technique and preliminary results. Eur Radiol 15:174–182CrossRefPubMed Zangos S, Eichler K, Engelmann K et al (2004) MR-guided transgluteal biopsies with an open low-field system in patients with clinically suspected prostate cancer: technique and preliminary results. Eur Radiol 15:174–182CrossRefPubMed
13.
Zurück zum Zitat Adam G, Bucker A, Nolte-Ernsting C, Tacke J, Gunther RW (1999) Interventional MR imaging: percutaneous abdominal and skeletal biopsies and drainages of the abdomen. Eur Radiol 9:1471–1478CrossRefPubMed Adam G, Bucker A, Nolte-Ernsting C, Tacke J, Gunther RW (1999) Interventional MR imaging: percutaneous abdominal and skeletal biopsies and drainages of the abdomen. Eur Radiol 9:1471–1478CrossRefPubMed
14.
Zurück zum Zitat Carlson SK, Bender CE, Classic KL, Zink FE, Quam JP, Ward EM, Oberg AL (2001) Benefits and safety of CT fluoroscopy in interventional radiologic procedures. Radiology 219:515–520PubMed Carlson SK, Bender CE, Classic KL, Zink FE, Quam JP, Ward EM, Oberg AL (2001) Benefits and safety of CT fluoroscopy in interventional radiologic procedures. Radiology 219:515–520PubMed
15.
Zurück zum Zitat Arellano R, Boland G, Mueller P (2000) Adrenal biopsy in a patient with lung cancer: imaging algorithm and biopsy indications, technique, and complications. AJR Am J Roentgenol 175:1613–1617PubMed Arellano R, Boland G, Mueller P (2000) Adrenal biopsy in a patient with lung cancer: imaging algorithm and biopsy indications, technique, and complications. AJR Am J Roentgenol 175:1613–1617PubMed
16.
Zurück zum Zitat Daly B, Krebs TL, Wong-You-Cheong JJ, Wang SS (1999) Percutaneous abdominal and pelvic interventional procedures using CT fluoroscopy guidance. AJR Am J Roentgenol 173:637–644PubMed Daly B, Krebs TL, Wong-You-Cheong JJ, Wang SS (1999) Percutaneous abdominal and pelvic interventional procedures using CT fluoroscopy guidance. AJR Am J Roentgenol 173:637–644PubMed
17.
Zurück zum Zitat Froelich JJ, Ishaque N, Saar B, Regn J, Walthers EM, Mauermann F, Klose KJ (1999) Control of percutaneous biopsy with CT fluoroscopy. Rofo Fortschr Geb Rontgenstr Neuen Bildgeb Verfahr 170:191–197PubMed Froelich JJ, Ishaque N, Saar B, Regn J, Walthers EM, Mauermann F, Klose KJ (1999) Control of percutaneous biopsy with CT fluoroscopy. Rofo Fortschr Geb Rontgenstr Neuen Bildgeb Verfahr 170:191–197PubMed
18.
Zurück zum Zitat Silverman SG, Tuncali K, Adams DF, Nawfel RD, Zou KH, Judy PF (1999) CT fluoroscopy-guided abdominal interventions: techniques, results, and radiation exposure. Radiology 212:673–681PubMed Silverman SG, Tuncali K, Adams DF, Nawfel RD, Zou KH, Judy PF (1999) CT fluoroscopy-guided abdominal interventions: techniques, results, and radiation exposure. Radiology 212:673–681PubMed
19.
Zurück zum Zitat Nawfel R, Judy P, Silverman S, Hooton S, Tuncali K, Adams D (2000) Patient and personnel exposure during CT fluoroscopy-guided interventional procedures. Radiology 216:180–184PubMed Nawfel R, Judy P, Silverman S, Hooton S, Tuncali K, Adams D (2000) Patient and personnel exposure during CT fluoroscopy-guided interventional procedures. Radiology 216:180–184PubMed
20.
Zurück zum Zitat Lufkin RB, Gronemeyer DH, Seibel RM (1997) Interventional MRI: update. Eur Radiol 7:187–200CrossRef Lufkin RB, Gronemeyer DH, Seibel RM (1997) Interventional MRI: update. Eur Radiol 7:187–200CrossRef
21.
Zurück zum Zitat Konig CW, Pereira PL, Trubenbach J, Fritz J, Duda SH, Schick F, Claussen CD (2003) MR imaging-guided adrenal biopsy using an open low-field-strength scanner and MR fluoroscopy. AJR Am J Roentgenol 180:1567–1570PubMed Konig CW, Pereira PL, Trubenbach J, Fritz J, Duda SH, Schick F, Claussen CD (2003) MR imaging-guided adrenal biopsy using an open low-field-strength scanner and MR fluoroscopy. AJR Am J Roentgenol 180:1567–1570PubMed
22.
Zurück zum Zitat Schweiger GD, Yip VY, Brown BP (2000) CT fluoroscopic guidance for percutaneous needle placement into abdominopelvic lesions with difficult access routes. Abdom Imaging 25:633–637CrossRefPubMed Schweiger GD, Yip VY, Brown BP (2000) CT fluoroscopic guidance for percutaneous needle placement into abdominopelvic lesions with difficult access routes. Abdom Imaging 25:633–637CrossRefPubMed
23.
Zurück zum Zitat Frahm C, Gehl HB, Melchert UH, Weiss HD (1996) Visualization of magnetic resonance-compatible needles at 1.5 and 0.2 Tesla. Cardiovasc Intervent Radiol 19:335–340CrossRefPubMed Frahm C, Gehl HB, Melchert UH, Weiss HD (1996) Visualization of magnetic resonance-compatible needles at 1.5 and 0.2 Tesla. Cardiovasc Intervent Radiol 19:335–340CrossRefPubMed
24.
Zurück zum Zitat Ladd ME, Erhart P, Debatin JF, Romanowski BJ, Boesiger P, McKinnon GC (1996) Biopsy needle susceptibility artifacts. Magn Reson Med 36:646–651 Ladd ME, Erhart P, Debatin JF, Romanowski BJ, Boesiger P, McKinnon GC (1996) Biopsy needle susceptibility artifacts. Magn Reson Med 36:646–651
25.
Zurück zum Zitat Lewin JS, Duerk JL, Jain VR, Petersilge CA, Chao CP, Haaga JR (1996) Needle localization in MR-guided biopsy and aspiration: effects of field strength, sequence design, and magnetic field orientation. AJR Am J Roentgenol 166:1337–1345PubMed Lewin JS, Duerk JL, Jain VR, Petersilge CA, Chao CP, Haaga JR (1996) Needle localization in MR-guided biopsy and aspiration: effects of field strength, sequence design, and magnetic field orientation. AJR Am J Roentgenol 166:1337–1345PubMed
26.
Zurück zum Zitat Alanen J, Keski-Nisula L, Blanco-Sequeiros R, Tervonen O (2004) Cost comparison analysis of low-field (0.23 T) MRI- and CT-guided bone biopsies. Eur Radiol 14:123–128CrossRefPubMed Alanen J, Keski-Nisula L, Blanco-Sequeiros R, Tervonen O (2004) Cost comparison analysis of low-field (0.23 T) MRI- and CT-guided bone biopsies. Eur Radiol 14:123–128CrossRefPubMed
27.
Zurück zum Zitat Langen HJ, Kugel H, Ortmann M, Noack M, de Rochemont RM, Landwehr P (2001) Functional capacity of MRI-compatible biopsy needles in comparison with ferromagnetic biopsy needles. In vitro studies. Rofo Fortschr Geb Rontgenstr Neuen Bildgeb Verfahr 173:658–662CrossRefPubMed Langen HJ, Kugel H, Ortmann M, Noack M, de Rochemont RM, Landwehr P (2001) Functional capacity of MRI-compatible biopsy needles in comparison with ferromagnetic biopsy needles. In vitro studies. Rofo Fortschr Geb Rontgenstr Neuen Bildgeb Verfahr 173:658–662CrossRefPubMed
28.
Zurück zum Zitat Sklair-Levy M, Lebensart P, Applbaum Y et al (2001) Percutaneous image-guided needle biopsy in children-summary of our experience with 57 children. Pediatr Radiol 31:732–736CrossRefPubMed Sklair-Levy M, Lebensart P, Applbaum Y et al (2001) Percutaneous image-guided needle biopsy in children-summary of our experience with 57 children. Pediatr Radiol 31:732–736CrossRefPubMed
29.
Zurück zum Zitat Hussain H, Kingston J, Domizio P, Norton A, Reznek R (2001) Imaging-guided core biopsy for the diagnosis of malignant tumors in pediatric patients. AJR Am J Roentgenol 176:43–47PubMed Hussain H, Kingston J, Domizio P, Norton A, Reznek R (2001) Imaging-guided core biopsy for the diagnosis of malignant tumors in pediatric patients. AJR Am J Roentgenol 176:43–47PubMed
30.
31.
Zurück zum Zitat Hohenberger W, Kastl S (2000) Neoadjuvant and adjuvant therapy of ductal pancreatic carcinoma. Zentralbl Chir 125:348–355PubMed Hohenberger W, Kastl S (2000) Neoadjuvant and adjuvant therapy of ductal pancreatic carcinoma. Zentralbl Chir 125:348–355PubMed
32.
Zurück zum Zitat Demharter J, Muller P, Wagner T, Schlimok G, Haude K, Bohndorf K (2001) Percutaneous core-needle biopsy of enlarged lymph nodes in the diagnosis and subclassification of malignant lymphomas. Eur Radiol 11:276–283CrossRefPubMed Demharter J, Muller P, Wagner T, Schlimok G, Haude K, Bohndorf K (2001) Percutaneous core-needle biopsy of enlarged lymph nodes in the diagnosis and subclassification of malignant lymphomas. Eur Radiol 11:276–283CrossRefPubMed
33.
Zurück zum Zitat Ghaye B, Dondelinger RF, Dewe W (1999) Percutaneous CT-guided lung biopsy: sequential versus spiral scanning. A randomized prospective study. Eur Radiol 9:1317–1320CrossRefPubMed Ghaye B, Dondelinger RF, Dewe W (1999) Percutaneous CT-guided lung biopsy: sequential versus spiral scanning. A randomized prospective study. Eur Radiol 9:1317–1320CrossRefPubMed
Metadaten
Titel
MR-guided biopsies of lesions in the retroperitoneal space: technique and results
verfasst von
S. Zangos
K. Eichler
A. Wetter
T. Lehnert
R. Hammerstingl
T. Diebold
P. Reichel
C. Herzog
M.-L. Hansmann
M. G. Mack
T. J. Vogl
Publikationsdatum
01.02.2006
Erschienen in
European Radiology / Ausgabe 2/2006
Print ISSN: 0938-7994
Elektronische ISSN: 1432-1084
DOI
https://doi.org/10.1007/s00330-005-2870-2

Weitere Artikel der Ausgabe 2/2006

European Radiology 2/2006 Zur Ausgabe

Update Radiologie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.