Skip to main content
Erschienen in: European Radiology 6/2006

01.06.2006 | Computer Tomography

Ultra-high resolution flat-panel volume CT: fundamental principles, design architecture, and system characterization

verfasst von: Rajiv Gupta, Michael Grasruck, Christoph Suess, Soenke H. Bartling, Bernhard Schmidt, Karl Stierstorfer, Stefan Popescu, Tom Brady, Thomas Flohr

Erschienen in: European Radiology | Ausgabe 6/2006

Einloggen, um Zugang zu erhalten

Abstract

Digital flat-panel-based volume CT (VCT) represents a unique design capable of ultra-high spatial resolution, direct volumetric imaging, and dynamic CT scanning. This innovation, when fully developed, has the promise of opening a unique window on human anatomy and physiology. For example, the volumetric coverage offered by this technology enables us to observe the perfusion of an entire organ, such as the brain, liver, or kidney, tomographically (e.g., after a transplant or ischemic event). By virtue of its higher resolution, one can directly visualize the trabecular structure of bone. This paper describes the basic design architecture of VCT. Three key technical challenges, viz., scatter correction, dynamic range extension, and temporal resolution improvement, must be addressed for successful implementation of a VCT scanner. How these issues are solved in a VCT prototype and the modifications necessary to enable ultra-high resolution volumetric scanning are described. The fundamental principles of scatter correction and dose reduction are illustrated with the help of an actual prototype. The image quality metrics of this prototype are characterized and compared with a multi-detector CT (MDCT).
Literatur
1.
Zurück zum Zitat Popescu S, Stierstorfer K, Flohr T, Suess C, Grasruck M (2005) Design and evaluation of a prototype volume CT scanner. Proc of SPIE 5745:600–608CrossRef Popescu S, Stierstorfer K, Flohr T, Suess C, Grasruck M (2005) Design and evaluation of a prototype volume CT scanner. Proc of SPIE 5745:600–608CrossRef
2.
Zurück zum Zitat Ross WR, Dawn C, Fitzgerald P, Basu SK, Beaver R, Cody D (2004) Performance and pre-clinical results from a flat-panel-based volumetric CT system. Proc of RSNA 2004:SSG18–02 Ross WR, Dawn C, Fitzgerald P, Basu SK, Beaver R, Cody D (2004) Performance and pre-clinical results from a flat-panel-based volumetric CT system. Proc of RSNA 2004:SSG18–02
3.
Zurück zum Zitat Grasruck M, Suess Ch, Stierstorfer K, Popescu S, Flohr T (2005) Evaluation of image quality and dose on a flat-panel CT-scanner. Proc of SPIE 5745:179–188CrossRef Grasruck M, Suess Ch, Stierstorfer K, Popescu S, Flohr T (2005) Evaluation of image quality and dose on a flat-panel CT-scanner. Proc of SPIE 5745:179–188CrossRef
4.
Zurück zum Zitat Roos PG et al (2004) Multiple gain ranging readout method to extend the dynamic range of amorphous silicon flat panel imagers. Proc of SPIE 5368:139–149CrossRef Roos PG et al (2004) Multiple gain ranging readout method to extend the dynamic range of amorphous silicon flat panel imagers. Proc of SPIE 5368:139–149CrossRef
5.
Zurück zum Zitat Ramachandran GN, Lakshminarayanan AV (1971) Three dimensional reconstructions from radiographs and electron micrographs: application of convolution instead of Fourier transform. Proc Nat Acad Sci 68:2236–2240PubMedCrossRef Ramachandran GN, Lakshminarayanan AV (1971) Three dimensional reconstructions from radiographs and electron micrographs: application of convolution instead of Fourier transform. Proc Nat Acad Sci 68:2236–2240PubMedCrossRef
6.
Zurück zum Zitat Feldkamp LA, Davis LC, Kress JW (1984) Practical cone-beam algorithm. J Opt Soc Am 1(6):612–619CrossRef Feldkamp LA, Davis LC, Kress JW (1984) Practical cone-beam algorithm. J Opt Soc Am 1(6):612–619CrossRef
7.
Zurück zum Zitat Wiegert J, Bertram M, Schaefer D, Conrads N, Timmer J, Aach T, Rose G (2004) Soft-tissue contrast resolution within the head of human cadaver by means of flat-detector-based cone-beam CT. Proc of SPIE 5368:67–78CrossRef Wiegert J, Bertram M, Schaefer D, Conrads N, Timmer J, Aach T, Rose G (2004) Soft-tissue contrast resolution within the head of human cadaver by means of flat-detector-based cone-beam CT. Proc of SPIE 5368:67–78CrossRef
8.
Zurück zum Zitat Gupta R, Bartling SH, Basu SK, Ross WR, Becker H, Pfoh A, Brady T, Curtin HD (2004) Experimental flat-panel high-spatial-resolution volume CT of the temporal bone. Am J Neuroradiol 25(8):1417–1424PubMed Gupta R, Bartling SH, Basu SK, Ross WR, Becker H, Pfoh A, Brady T, Curtin HD (2004) Experimental flat-panel high-spatial-resolution volume CT of the temporal bone. Am J Neuroradiol 25(8):1417–1424PubMed
9.
Zurück zum Zitat Bartling SH (2002) Experimental results: Volume-CT (VCT) could overcome CT limitations in cochlea implant imaging. J Neuroradiol 29:175 Bartling SH (2002) Experimental results: Volume-CT (VCT) could overcome CT limitations in cochlea implant imaging. J Neuroradiol 29:175
10.
Zurück zum Zitat Rodt T, Bartling SH, Gupta R, Pfoh A, Weber BP, Becker H (2002) Optimization of temporal bone CT and 3D-imaging: An experimental approach. Comput Aided Surg 7(2):107–126CrossRef Rodt T, Bartling SH, Gupta R, Pfoh A, Weber BP, Becker H (2002) Optimization of temporal bone CT and 3D-imaging: An experimental approach. Comput Aided Surg 7(2):107–126CrossRef
11.
Zurück zum Zitat Bartling SH, Shukla V, Becker H, Brady TJ, Hayman A, Gupta R (2005) High-resolution flat-panel volume-CT of temporal bone. Part 1: axial preoperative anatomy. J Comput Assist Tomogr 29(3):420–423CrossRefPubMed Bartling SH, Shukla V, Becker H, Brady TJ, Hayman A, Gupta R (2005) High-resolution flat-panel volume-CT of temporal bone. Part 1: axial preoperative anatomy. J Comput Assist Tomogr 29(3):420–423CrossRefPubMed
12.
Zurück zum Zitat Bartling SH, Shukla V, Becker H, Brady TJ, Hayman A, Gupta R (2005) High-resolution computed tomography of temporal bone. Part II: Coronal preoperative anatomy. J Comput Assist Tomogr 29(4):566–569CrossRefPubMed Bartling SH, Shukla V, Becker H, Brady TJ, Hayman A, Gupta R (2005) High-resolution computed tomography of temporal bone. Part II: Coronal preoperative anatomy. J Comput Assist Tomogr 29(4):566–569CrossRefPubMed
13.
Zurück zum Zitat Bartling S, Rodt T, Gupta R, Weber BP, Nain D, Kikinis R, Pfoh A, Becker H (2002) Experimentelle Untersuchung einer neuen CT Technologie in der Felsenbeindiagnostik. Röfo Fortschr Geb Röntgenstr Neuen Bildgeb Verfahr 174(Suppl. 1):249 Bartling S, Rodt T, Gupta R, Weber BP, Nain D, Kikinis R, Pfoh A, Becker H (2002) Experimentelle Untersuchung einer neuen CT Technologie in der Felsenbeindiagnostik. Röfo Fortschr Geb Röntgenstr Neuen Bildgeb Verfahr 174(Suppl. 1):249
14.
Zurück zum Zitat Obert M, Ahlemeyer B, Baumgart-Vogt E, Traupe H (2005) Flat-panel volumetric computed tomography: a new method for visualizing fine bone detail in living mice. J Comput Assist Tomogr 29(4):560–565CrossRefPubMed Obert M, Ahlemeyer B, Baumgart-Vogt E, Traupe H (2005) Flat-panel volumetric computed tomography: a new method for visualizing fine bone detail in living mice. J Comput Assist Tomogr 29(4):560–565CrossRefPubMed
15.
Zurück zum Zitat Brix G, Nagel HD, Stamm G, Veit R, Lechel U, Griebel J, Galanski M (2005) Radiation exposure in multi-slice versus single-slice spiral CT: results of a nationwide survey. Eur Radiol 13(8):1979–1979CrossRef Brix G, Nagel HD, Stamm G, Veit R, Lechel U, Griebel J, Galanski M (2005) Radiation exposure in multi-slice versus single-slice spiral CT: results of a nationwide survey. Eur Radiol 13(8):1979–1979CrossRef
16.
Zurück zum Zitat Nikolaou K, Flohr T, Stierstorfer K, Becker CR, Reiser MF (2005) Flat panel computed tomography of human ex vivo heart and bone specimens: initial experience. Eur Radiol 15(2):329–333 FebPubMedCrossRef Nikolaou K, Flohr T, Stierstorfer K, Becker CR, Reiser MF (2005) Flat panel computed tomography of human ex vivo heart and bone specimens: initial experience. Eur Radiol 15(2):329–333 FebPubMedCrossRef
Metadaten
Titel
Ultra-high resolution flat-panel volume CT: fundamental principles, design architecture, and system characterization
verfasst von
Rajiv Gupta
Michael Grasruck
Christoph Suess
Soenke H. Bartling
Bernhard Schmidt
Karl Stierstorfer
Stefan Popescu
Tom Brady
Thomas Flohr
Publikationsdatum
01.06.2006
Verlag
Springer-Verlag
Erschienen in
European Radiology / Ausgabe 6/2006
Print ISSN: 0938-7994
Elektronische ISSN: 1432-1084
DOI
https://doi.org/10.1007/s00330-006-0156-y

Weitere Artikel der Ausgabe 6/2006

European Radiology 6/2006 Zur Ausgabe

Letter to the Editor

Reply of Editor-in-Chief

Update Radiologie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.