Low-dose ECG-gated 64-slices helical CT angiography of the chest: evaluation of image quality in 105 patients

verfasst von: A. G. d’Agostino, M. Remy-Jardin, C. Khalil, V. Delannoy-Deken, T. Flohr, A. Duhamel, J. Remy

Erschienen in: European Radiology | Ausgabe 10/2006

Einloggen, um Zugang zu erhalten

Abstract

The purpose of this study was to evaluate image quality of low-dose electrocardiogram (ECG)-gated multislice helical computed tomography (CT) angiograms of the chest. One hundred and five consecutive patients with a regular sinus rhythm (72 men; 33 women) underwent ECG-gated CT angiographic examination of the chest without administration of beta blockers using the following parameters: (a) collimation 32×0.6 mm with z-flying focal spot for the acquisition of 64 overlapping 0.6-mm slices, rotation time 0.33 s, pitch 0.3; (b) 120 kV, 200 mAs; (c) use of two dose modulation systems, including adjustment of the mAs setting to the patient’s size and anatomical shape and an ECG-controlled tube current. Subjective and objective image quality was evaluated by two radiologists in consensus on 3-mm-thick scans reconstructed at 55% of the response rate (RR) interval. The population and protocol characteristics included: (a) a mean [±standard deviation (SD)] body mass index (BMI) of 24.47 (±4.64); (b) a mean (±SD) heart rate of 72.04 (±15.76) bpm; (c) a mean (±SD) scanning time of 18.3 (±2.73) s; (d) a mean (±SD) dose-length product (DLP) value of 260.57 (±83.67) mGy/cm; (e) an estimated average effective dose of 4.95 (±1.59) mSv. Subjective noise was depicted in a total of nine examinations (8.5%), always rated as mild. Objective noise was assessed by measuring the standard deviation of pixel values in a homogeneous region of interest within the trachea and descending aorta; SD was 15.91 HU in the trachea and 22.16 HU in the descending aorta, with no significant difference in the mean value of the standard deviations between the four categories of BMI except for obese patients, who had a higher mean SD within the aorta. Interpolation artefacts were depicted in 22 patients, with a mean heart rate significantly lower than that of patients without interpolation artifacts, rated as mild in 11 patients and severe in 11 patients. The severity of interpolation artefacts was significantly linked to a low heart rate in affected patients. The overall image quality of CT scans was rated as diagnostic in 94 patients (89.5%) while 11 examinations (10.5%) were found to be partially nondiagnostic owing to the cyclic presence of severe interpolation artefacts, which can be compensated for by additional reconstructions at a different temporal window. In these cases, interpolation artefacts could have been avoided by reducing the pitch from 0.3 to 0.2 at the expense of increased patient dose. Low-dose ECG-gated CT angiograms of the chest can be obtained in routine clinical practice with 64-slice CT technology without altering the diagnostic value of CT scans.
Literatur
1.
Zurück zum Zitat Oldershaw P (1992) Assessment of right ventricular function and its role in clinical practice. Br Heart J 68:12–15PubMedCrossRef Oldershaw P (1992) Assessment of right ventricular function and its role in clinical practice. Br Heart J 68:12–15PubMedCrossRef
2.
Zurück zum Zitat Coche E, Vlassenbroeck A, Roelants V, D’Hoore W, Verschuren F, Goncette L, Maldague B (2005) Evaluation of biventricular ejection fraction with ECG-gated 16-slice CT: preliminary findings in acute pulmonary embolism in comparison with radionuclide ventriculography. Eur Radiol 15:1432–1440CrossRefPubMed Coche E, Vlassenbroeck A, Roelants V, D’Hoore W, Verschuren F, Goncette L, Maldague B (2005) Evaluation of biventricular ejection fraction with ECG-gated 16-slice CT: preliminary findings in acute pulmonary embolism in comparison with radionuclide ventriculography. Eur Radiol 15:1432–1440CrossRefPubMed
3.
Zurück zum Zitat Delhaye D, Remy-Jardin M, Teisseire A, Hossein-Foucher C, Leroy S, Duhamel A, Remy J (2005) Estimation of right ventricular ejection fraction by multidetector row CT: comparison with equilibrium radionuclide scintigraphy (Part 1) AJR (in press) Delhaye D, Remy-Jardin M, Teisseire A, Hossein-Foucher C, Leroy S, Duhamel A, Remy J (2005) Estimation of right ventricular ejection fraction by multidetector row CT: comparison with equilibrium radionuclide scintigraphy (Part 1) AJR (in press)
4.
Zurück zum Zitat Salem R, Remy-Jardin M, Delhaye D, Khalil C, Teisseire A, Delannoy-Deken V, Duhamel A, Remy J (2005) Integrated cardiothoracic imaging with ECG-gated 64-slice multidetector-row CT: preliminary experience in 133 patients. Eur Radiol DOI:10.1007/s00330-006-157-x Salem R, Remy-Jardin M, Delhaye D, Khalil C, Teisseire A, Delannoy-Deken V, Duhamel A, Remy J (2005) Integrated cardiothoracic imaging with ECG-gated 64-slice multidetector-row CT: preliminary experience in 133 patients. Eur Radiol DOI:10.​1007/​s00330-006-157-x
5.
Zurück zum Zitat Remy-Jardin M, Delhaye D, Salem R, Teisseire A, Khalil C, Delannoy-Deken V, Duhamel A, Remy J (2006) Coronary imaging quality in routine ECG-gated multidetector CT examinations of the entire thorax: preliminary experience with a 64-slice CT system. Eur Radiol (submitted for publication) Remy-Jardin M, Delhaye D, Salem R, Teisseire A, Khalil C, Delannoy-Deken V, Duhamel A, Remy J (2006) Coronary imaging quality in routine ECG-gated multidetector CT examinations of the entire thorax: preliminary experience with a 64-slice CT system. Eur Radiol (submitted for publication)
6.
Zurück zum Zitat Nieman K, Cademartiri F, Lemos PA, Raaijmakers R, Pattynama PM, Reyter PJ (2002) Reliable non-invasive coronary angiography with fast submillimeter multislice spiral computed tomography. Circulation 106:2051–2054CrossRefPubMed Nieman K, Cademartiri F, Lemos PA, Raaijmakers R, Pattynama PM, Reyter PJ (2002) Reliable non-invasive coronary angiography with fast submillimeter multislice spiral computed tomography. Circulation 106:2051–2054CrossRefPubMed
7.
Zurück zum Zitat Hunold P, Vogt F, Schmermund A, Debatin JF, Kerkhoff G, Budde T, Erbel R, Ewen K, Barkhausen J (2003) Radiation exposure during cardiac CT: effective doses at multi-detector row CT and electron-beam CT. Radiology 226:145–152PubMedCrossRef Hunold P, Vogt F, Schmermund A, Debatin JF, Kerkhoff G, Budde T, Erbel R, Ewen K, Barkhausen J (2003) Radiation exposure during cardiac CT: effective doses at multi-detector row CT and electron-beam CT. Radiology 226:145–152PubMedCrossRef
8.
Zurück zum Zitat Mollet NR, Cademartiri F, Krestin G, McFadden EP, Arampatzis CA, Serruys PW, de Feyter PJ (2005) Improved diagnostic accuracy with 16-row multislice computed tomography coronary angiography. J Am Coll Cardiol 45:128–132CrossRefPubMed Mollet NR, Cademartiri F, Krestin G, McFadden EP, Arampatzis CA, Serruys PW, de Feyter PJ (2005) Improved diagnostic accuracy with 16-row multislice computed tomography coronary angiography. J Am Coll Cardiol 45:128–132CrossRefPubMed
9.
Zurück zum Zitat Jakobs TF, Becker CR, Ohnesorge B, Flohr T, Suess C, Schoepf UJ, Reiser MF (2002) Multislice helical CT of the heart with retrospective ECG gating: reduction of radiation exposure by ECG-controlled tube current modulation. Eur Radiol 12:1081–1086CrossRefPubMed Jakobs TF, Becker CR, Ohnesorge B, Flohr T, Suess C, Schoepf UJ, Reiser MF (2002) Multislice helical CT of the heart with retrospective ECG gating: reduction of radiation exposure by ECG-controlled tube current modulation. Eur Radiol 12:1081–1086CrossRefPubMed
10.
Zurück zum Zitat Trabold T, Buchgeister M, Kurtner A et al (2003) Estimation of radiation exposure in 16-detecor row computed tomography of the heart with retrospective ECG-gating. Rofo 175:1051–1055PubMed Trabold T, Buchgeister M, Kurtner A et al (2003) Estimation of radiation exposure in 16-detecor row computed tomography of the heart with retrospective ECG-gating. Rofo 175:1051–1055PubMed
11.
Zurück zum Zitat Ropers D, Baum U, Pohle K, Anders K, Ulzheimer S, Ohnesorge B, Schlundt C, Bautz W, Daniel WG, Achenbach S (2003) Detection of coronary artery stenoses with thin-slice multidetector row spiral computed tomography and multiplanar reconstruction. Circulation 107:664–666CrossRefPubMed Ropers D, Baum U, Pohle K, Anders K, Ulzheimer S, Ohnesorge B, Schlundt C, Bautz W, Daniel WG, Achenbach S (2003) Detection of coronary artery stenoses with thin-slice multidetector row spiral computed tomography and multiplanar reconstruction. Circulation 107:664–666CrossRefPubMed
12.
Zurück zum Zitat Wilberger JE, Mahnken AH, Schmitz-Rode T et al (2001) Individually adapted examination protocols for reduction of radiation exposure in chest CT. Invest Radiol 36:604–611CrossRefPubMed Wilberger JE, Mahnken AH, Schmitz-Rode T et al (2001) Individually adapted examination protocols for reduction of radiation exposure in chest CT. Invest Radiol 36:604–611CrossRefPubMed
13.
Zurück zum Zitat Tack D, De Maertelaer V, Gevenois PA (2003) Dose reduction in multidetector CT using attenuation-based on-line tube current modulation. AJR Am J Roentgenol 181:331–334PubMed Tack D, De Maertelaer V, Gevenois PA (2003) Dose reduction in multidetector CT using attenuation-based on-line tube current modulation. AJR Am J Roentgenol 181:331–334PubMed
14.
Zurück zum Zitat Sigal-Cinqualbre AB, Hennequin R, Abada H, Chen X, Paul JF (2004) Low-kilovoltage multidetector-row chest CT in adults: feasibility and effect on image quality and iodine dose. Radiology 231:169–174PubMedCrossRef Sigal-Cinqualbre AB, Hennequin R, Abada H, Chen X, Paul JF (2004) Low-kilovoltage multidetector-row chest CT in adults: feasibility and effect on image quality and iodine dose. Radiology 231:169–174PubMedCrossRef
15.
Zurück zum Zitat Das M, Horst G, Mahnken A, Mühlenbruch G, Stargardt A, Weis C, Flohr TG, Günther RW, Wildberger JE (2005) Individually adapted examination protocols for reduction of radiation exposure for 16-MDCT chest examinations. AJR Am J Roentgenol 184:1437–1443PubMed Das M, Horst G, Mahnken A, Mühlenbruch G, Stargardt A, Weis C, Flohr TG, Günther RW, Wildberger JE (2005) Individually adapted examination protocols for reduction of radiation exposure for 16-MDCT chest examinations. AJR Am J Roentgenol 184:1437–1443PubMed
16.
Zurück zum Zitat Van der Woude H, Zaagsma J, Postma DS, Winter TH, van Hulst M, Aalbers R (2005) Detrimental effects of beta-blockers in COPD. A concern for nonselective beta-blockers. Chest 127:818–824CrossRefPubMed Van der Woude H, Zaagsma J, Postma DS, Winter TH, van Hulst M, Aalbers R (2005) Detrimental effects of beta-blockers in COPD. A concern for nonselective beta-blockers. Chest 127:818–824CrossRefPubMed
17.
Zurück zum Zitat Herzog C, Abolmaali N, Balzer JO, Baunach S, Ackerman H, Dogan S, Britten MB, Vogl TJ (2002) Heart-rate-adapted image reconstruction in multidetector-row cardiac CT: influence of physiological and technical prerequisite on image quality. Eur Radiol 12:2670–2678PubMed Herzog C, Abolmaali N, Balzer JO, Baunach S, Ackerman H, Dogan S, Britten MB, Vogl TJ (2002) Heart-rate-adapted image reconstruction in multidetector-row cardiac CT: influence of physiological and technical prerequisite on image quality. Eur Radiol 12:2670–2678PubMed
18.
Zurück zum Zitat National Heart Lung and Blood Institute Obesity Education Initiative Expert Panel (1998) Clinical guidelines on the identification, evaluation, and treatment of overweight and obesity in adults: the Evidence Report. Rockville, Maryland: National Heart, Lung and Blood Institute National Heart Lung and Blood Institute Obesity Education Initiative Expert Panel (1998) Clinical guidelines on the identification, evaluation, and treatment of overweight and obesity in adults: the Evidence Report. Rockville, Maryland: National Heart, Lung and Blood Institute
19.
Zurück zum Zitat EC99 (1999) European guidelines on quality criteria for computed tomography. Report EURO 16262 EN. Luxembourg:69–78 EC99 (1999) European guidelines on quality criteria for computed tomography. Report EURO 16262 EN. Luxembourg:69–78
20.
Zurück zum Zitat Conover WJ, Iman RL (1981) Rank transformations as a bridge between parametric and nonparametric statistics. Am Stat 35:124–129CrossRef Conover WJ, Iman RL (1981) Rank transformations as a bridge between parametric and nonparametric statistics. Am Stat 35:124–129CrossRef
21.
Zurück zum Zitat Heuschmid M, Kuettner A, Schroeder S, Trabold T, Feyer A, Seeman MD, Kuzo R, Claussen CD, Kopp AF (2005) ECG-gated 16-MDCT of the coronary arteries: assessment of image quality and accuracy in detecting stenoses. AJR Am J Roentgenol 184:1413–1419PubMed Heuschmid M, Kuettner A, Schroeder S, Trabold T, Feyer A, Seeman MD, Kuzo R, Claussen CD, Kopp AF (2005) ECG-gated 16-MDCT of the coronary arteries: assessment of image quality and accuracy in detecting stenoses. AJR Am J Roentgenol 184:1413–1419PubMed
22.
Zurück zum Zitat Cademartiri F, Mollet NR, Runza G, Stierstorfer K, Flohr T, Krestin GP (2004) 64-slice spiral computed coronary angiography: improvement of spatial and temporal resolution (abstract) Radiology (P):760 Cademartiri F, Mollet NR, Runza G, Stierstorfer K, Flohr T, Krestin GP (2004) 64-slice spiral computed coronary angiography: improvement of spatial and temporal resolution (abstract) Radiology (P):760
23.
Zurück zum Zitat Stark G, Cederblad A, Forssell-Aronsson E, Sjöström L, Alspen M (2002) A method to obtain the same levels of CT image noise for patients of various sizes, to minimize radiation dose. Br J Radiol 75:140–150PubMed Stark G, Cederblad A, Forssell-Aronsson E, Sjöström L, Alspen M (2002) A method to obtain the same levels of CT image noise for patients of various sizes, to minimize radiation dose. Br J Radiol 75:140–150PubMed
24.
Zurück zum Zitat Hundt W, Rust F, Stäbler A, Wolff H, Suess C, Reiser M (2005) Dose reduction in multislice computed tomography. J Comput Assist Tomogr 29:140–147CrossRefPubMed Hundt W, Rust F, Stäbler A, Wolff H, Suess C, Reiser M (2005) Dose reduction in multislice computed tomography. J Comput Assist Tomogr 29:140–147CrossRefPubMed
Metadaten
Titel
Low-dose ECG-gated 64-slices helical CT angiography of the chest: evaluation of image quality in 105 patients
verfasst von
A. G. d’Agostino
M. Remy-Jardin
C. Khalil
V. Delannoy-Deken
T. Flohr
A. Duhamel
J. Remy
Publikationsdatum
01.10.2006
Verlag
Springer-Verlag
Erschienen in
European Radiology / Ausgabe 10/2006
Print ISSN: 0938-7994
Elektronische ISSN: 1432-1084
DOI
https://doi.org/10.1007/s00330-006-0218-1

Weitere Artikel der Ausgabe 10/2006

European Radiology 10/2006 Zur Ausgabe

Update Radiologie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.