Skip to main content
Erschienen in: European Radiology 11/2006

01.11.2006 | Cardiac

Coronary artery bypass grafts: assessment of graft patency and native coronary artery lesions using 16-slice MDCT

verfasst von: Norbert I. Stauder, Axel Küttner, Stephen Schröder, Tanja Drosch, Torsten Beck, Heidrun Stauder, Gunnar Blumenstock, Claus D. Claussen, Andreas F. Kopp

Erschienen in: European Radiology | Ausgabe 11/2006

Einloggen, um Zugang zu erhalten

Abstract

The objective of this study was to evaluate the accuracy of electrocardiography (ECG)-gated 16-slice multidetector-row computed tomography (MDCT) in detection of stenosis of bypass grafts and native coronary arteries in patients who have undergone coronary artery bypass grafting (CABG). ECG-gated contrast-enhanced MDCT using 12×0.75-mm collimation was performed in 20 patients with recurrent angina 4.75 years after undergoing CABG. A total of 50 grafts, 16 arterial and 34 venous, were examined. All graft and coronary segments were evaluated for stenosis in comparison with conventional coronary angiography (CCA). Among the 80 arterial graft segments, 62 could be assessed (77.5%). Sensitivity, specificity, and positive and negative predictive values for stenosis were 96.2%, 97.2%, 96.2%, and 97.2%, respectively. In a total of 180 venous graft segments, 167 could be assessed. Sensitivity, specificity, and positive and negative predictive values for stenosis were 98.5%, 93.9%, 91.8%, and 98.9%, respectively. MDCT could assess 179 of 260 native coronary artery segments (68.8%).Sensitivity, specificity, and positive and negative predictive values for stenosis were 92.1%, 76.9%, 87.5%, and 84.7%, respectively. Sixteen-slice MDCT provides excellent image quality and diagnostic accuracy in detection of graft and coronary artery lesions in patients with suspected graft dysfunction.
Literatur
1.
Zurück zum Zitat Coronary Artery Surgery Study (CASS) (1983) A randomized trial of coronary artery bypass surgery. Circulation 5:951–960 Coronary Artery Surgery Study (CASS) (1983) A randomized trial of coronary artery bypass surgery. Circulation 5:951–960
2.
Zurück zum Zitat Lytle BW, Loop FD, Cosgrove DM, Ratliff NB, Easley K, Taylor PC (1985) Long-term (5 to 12 years) serial studies of internal mammary artery and saphenous vein coronary bypass grafts. J Thorac Cardiovasc Surg 9:248–258 Lytle BW, Loop FD, Cosgrove DM, Ratliff NB, Easley K, Taylor PC (1985) Long-term (5 to 12 years) serial studies of internal mammary artery and saphenous vein coronary bypass grafts. J Thorac Cardiovasc Surg 9:248–258
3.
Zurück zum Zitat Cameron A, Davis KB, Green G, Schaff HV (1996) Coronary bypass surgery with internal-thoracic-artery grafts - effects on survival over a 15-year period. N Engl J Med 334:216–219PubMedCrossRef Cameron A, Davis KB, Green G, Schaff HV (1996) Coronary bypass surgery with internal-thoracic-artery grafts - effects on survival over a 15-year period. N Engl J Med 334:216–219PubMedCrossRef
4.
Zurück zum Zitat Fitzgibbon GM, Kafka HP, Leach AJ, Keon WJ, Hooper GD, Burton JR (1996) Coronary bypass graft fate and patient outcome: angiographic follow-up of 5,065 grafts related to survival and reoperation in 1,388 patients during 25 years. J Am Coll Cardiol 28(3):616–626PubMedCrossRef Fitzgibbon GM, Kafka HP, Leach AJ, Keon WJ, Hooper GD, Burton JR (1996) Coronary bypass graft fate and patient outcome: angiographic follow-up of 5,065 grafts related to survival and reoperation in 1,388 patients during 25 years. J Am Coll Cardiol 28(3):616–626PubMedCrossRef
5.
Zurück zum Zitat Motwani JG, Topol EJ (1998) Aortocoronary saphenous vein graft disease: pathogenesis, predisposition, and prevention. Circulation 97:916–931PubMed Motwani JG, Topol EJ (1998) Aortocoronary saphenous vein graft disease: pathogenesis, predisposition, and prevention. Circulation 97:916–931PubMed
6.
Zurück zum Zitat Johnson LW, Krone R (1993) Cardiac catheterization 1991: a report of the Registry of the Society for Cardiac Angiography and Interventions (SCA&I). Cathet Cardiovasc Diagn 28:219–220PubMed Johnson LW, Krone R (1993) Cardiac catheterization 1991: a report of the Registry of the Society for Cardiac Angiography and Interventions (SCA&I). Cathet Cardiovasc Diagn 28:219–220PubMed
7.
Zurück zum Zitat Wintersperger BJ, Engelmann MG, von-Smekal A, Knez A, Penzkofer HV, Hofling B, Laub G, Reiser MF (1998) Patency of coronary bypass grafts: assessment with breath-hold contrast-enhanced MR angiography: value of a non-electrocardiographically triggered technique. Radiology 208(2):345–351PubMed Wintersperger BJ, Engelmann MG, von-Smekal A, Knez A, Penzkofer HV, Hofling B, Laub G, Reiser MF (1998) Patency of coronary bypass grafts: assessment with breath-hold contrast-enhanced MR angiography: value of a non-electrocardiographically triggered technique. Radiology 208(2):345–351PubMed
8.
Zurück zum Zitat Langerak SE, Vliegen HW, Jukema JW, Kunz P, Zwinderman AH, Lamb HJ, van der Wall EE, de Roos A (2003) Value of magnetic resonance imaging for the noninvasive detection of stenosis in coronary artery bypass grafts and recipient coronary arteries. Circulation 107:1502–1508PubMedCrossRef Langerak SE, Vliegen HW, Jukema JW, Kunz P, Zwinderman AH, Lamb HJ, van der Wall EE, de Roos A (2003) Value of magnetic resonance imaging for the noninvasive detection of stenosis in coronary artery bypass grafts and recipient coronary arteries. Circulation 107:1502–1508PubMedCrossRef
9.
Zurück zum Zitat Stauder NI, Fenchel M, Stauder H, Kuttner A, Scheule AM, Kramer U, Claussen CD, Miller S (2005) Assessment of minimal invasive direct coronary artery bypass graft (MIDCAB) of the left internal mammary artery by magnetic resonance imaging. J Thorac Cardiovasc Surg 129(3):608–615 Stauder NI, Fenchel M, Stauder H, Kuttner A, Scheule AM, Kramer U, Claussen CD, Miller S (2005) Assessment of minimal invasive direct coronary artery bypass graft (MIDCAB) of the left internal mammary artery by magnetic resonance imaging. J Thorac Cardiovasc Surg 129(3):608–615
10.
Zurück zum Zitat Kreitner KF, Ehrhard K, Kunz RP, Abegunewardene N, Oberholzer K, Horstick G, Hake U, Mildenberger P, Thelen M (2004) Non-invasive assessment of coronary artery bypass grafts - an update. Fortschr Röntgenstr 176(8):1079–1088CrossRef Kreitner KF, Ehrhard K, Kunz RP, Abegunewardene N, Oberholzer K, Horstick G, Hake U, Mildenberger P, Thelen M (2004) Non-invasive assessment of coronary artery bypass grafts - an update. Fortschr Röntgenstr 176(8):1079–1088CrossRef
11.
Zurück zum Zitat Lackner K, Thurn P (1981) Computed tomography of the heart: ECG-gated and continuous scans. Radiology 140:413–420PubMed Lackner K, Thurn P (1981) Computed tomography of the heart: ECG-gated and continuous scans. Radiology 140:413–420PubMed
12.
Zurück zum Zitat Engelmann MG, Knez A, von Smekal A, Wintersperger BJ, Huehns TY, Hofling B, Reiser MF, Steinbeck G (2000) Non-invasive coronary bypass graft imaging after multivessel revascularisation. Int J Cardiol 76(1):65–74PubMedCrossRef Engelmann MG, Knez A, von Smekal A, Wintersperger BJ, Huehns TY, Hofling B, Reiser MF, Steinbeck G (2000) Non-invasive coronary bypass graft imaging after multivessel revascularisation. Int J Cardiol 76(1):65–74PubMedCrossRef
13.
Zurück zum Zitat Ha JW, Cho SY, Shim WH, Chung N, Jang Y, Lee HM, Choe KO, Chung WJ, Choi SH, Yoo KJ, Kang MS (1999) Noninvasive evaluation of coronary artery bypass graft patency using three-dimensional angiography obtained with contrast-enhanced electron beam CT. Am J Roentgenol 172(4):1055–1059 Ha JW, Cho SY, Shim WH, Chung N, Jang Y, Lee HM, Choe KO, Chung WJ, Choi SH, Yoo KJ, Kang MS (1999) Noninvasive evaluation of coronary artery bypass graft patency using three-dimensional angiography obtained with contrast-enhanced electron beam CT. Am J Roentgenol 172(4):1055–1059
14.
Zurück zum Zitat Lu B, Dai R, Jing B, Bai H, He S, Zhuang N, Wu Q, Zhu X (2001) Evaluation of coronary artery bypass graft patency using three-dimensional reconstruction and flow study of electron beam tomography. Chin Med J 114(5):466–472PubMed Lu B, Dai R, Jing B, Bai H, He S, Zhuang N, Wu Q, Zhu X (2001) Evaluation of coronary artery bypass graft patency using three-dimensional reconstruction and flow study of electron beam tomography. Chin Med J 114(5):466–472PubMed
15.
Zurück zum Zitat von Smekal A, Knez A, Seelos KC, Habrel R, Spiegl F, Reichart B, Steinbeck G, Reiser M, (1997) Comparison of ultrafast computed tomography, magnetic resonance angiography and selective angiography for the detection of coronary bypass patency. Fortschr Röntgenstr 166(3):185–191CrossRef von Smekal A, Knez A, Seelos KC, Habrel R, Spiegl F, Reichart B, Steinbeck G, Reiser M, (1997) Comparison of ultrafast computed tomography, magnetic resonance angiography and selective angiography for the detection of coronary bypass patency. Fortschr Röntgenstr 166(3):185–191CrossRef
16.
Zurück zum Zitat Silber S, Finsterer S, Krischke I, Lochow P, Muhling H (2003) Noninvasive angiography of coronary bypass grafts with cardio-CT in a cardiology practice. Herz 28(2):126–135PubMedCrossRef Silber S, Finsterer S, Krischke I, Lochow P, Muhling H (2003) Noninvasive angiography of coronary bypass grafts with cardio-CT in a cardiology practice. Herz 28(2):126–135PubMedCrossRef
17.
Zurück zum Zitat Nieman K, Pattynama PM, Rensing BJ, van Geuns R-JM, de Feyter PJ (2003) Evaluation of patients after coronary artery bypass surgery: CT angiographic assessment of grafts and coronary arteries. Radiology 229:749–756PubMed Nieman K, Pattynama PM, Rensing BJ, van Geuns R-JM, de Feyter PJ (2003) Evaluation of patients after coronary artery bypass surgery: CT angiographic assessment of grafts and coronary arteries. Radiology 229:749–756PubMed
18.
Zurück zum Zitat Ropers D, Ulzheimer S, Wenkel E, Baum U, Giesler T, Derlien H, Moshage W, Bautz WA, Daniel WG, Kalender WA, Achenbach S (2001) Investigation of aortocoronary artery bypass grafts by multislice spiral computed tomography with electrocardiographic-gated image reconstruction. Am J Cardiol 88(7):792–795PubMedCrossRef Ropers D, Ulzheimer S, Wenkel E, Baum U, Giesler T, Derlien H, Moshage W, Bautz WA, Daniel WG, Kalender WA, Achenbach S (2001) Investigation of aortocoronary artery bypass grafts by multislice spiral computed tomography with electrocardiographic-gated image reconstruction. Am J Cardiol 88(7):792–795PubMedCrossRef
19.
Zurück zum Zitat Marano R, Storto ML, Maddestra N, Bonomo L (2004) Non-invasive assessment of coronary artery bypass graft with retrospectively ECG-gated four-row multi-detector spiral computed tomography. Eur Radiol 14(8):1353–1362PubMedCrossRef Marano R, Storto ML, Maddestra N, Bonomo L (2004) Non-invasive assessment of coronary artery bypass graft with retrospectively ECG-gated four-row multi-detector spiral computed tomography. Eur Radiol 14(8):1353–1362PubMedCrossRef
20.
Zurück zum Zitat Nieman K, Cademartiri F, Lemos PA, Raaijmakers R, Pattynama PM, de Feyter PJ (2002) Reliable noninvasive coronary angiography with fast submillimeter multislice spiral computed tomography. Circulation 106(16):2051–2054PubMedCrossRef Nieman K, Cademartiri F, Lemos PA, Raaijmakers R, Pattynama PM, de Feyter PJ (2002) Reliable noninvasive coronary angiography with fast submillimeter multislice spiral computed tomography. Circulation 106(16):2051–2054PubMedCrossRef
21.
Zurück zum Zitat Ropers D, Baum U, Pohle K, Anders K, Ulzheimer S, Ohnesorge B, Schlundt C, Bautz W, Daniel WG, Achenbach S (2003) Detection of coronary artery stenoses with thin-slice multi-detector row spiral computed tomography and multiplanar reconstruction. Circulation 107(5):664–666PubMedCrossRef Ropers D, Baum U, Pohle K, Anders K, Ulzheimer S, Ohnesorge B, Schlundt C, Bautz W, Daniel WG, Achenbach S (2003) Detection of coronary artery stenoses with thin-slice multi-detector row spiral computed tomography and multiplanar reconstruction. Circulation 107(5):664–666PubMedCrossRef
22.
Zurück zum Zitat Schlosser T, Konorza T, Hunold P, Kuhl H, Schmermund A, Barkhausen J (2004) Noninvasive visualization of coronary artery bypass grafts using 16-detector row computed tomography. J Am Coll Cardiol 44(6):1224–1229PubMedCrossRef Schlosser T, Konorza T, Hunold P, Kuhl H, Schmermund A, Barkhausen J (2004) Noninvasive visualization of coronary artery bypass grafts using 16-detector row computed tomography. J Am Coll Cardiol 44(6):1224–1229PubMedCrossRef
23.
Zurück zum Zitat Martuscelli E, Romagnoli A, D’Eliseo A, Tomassini M, Razzini C, Sperandio M, Simonetti G, Romeo F, Mehta JL (2004) Evaluation of venous and arterial conduit patency by 16-slice spiral computed tomography. Circulation 110:3234–3238PubMedCrossRef Martuscelli E, Romagnoli A, D’Eliseo A, Tomassini M, Razzini C, Sperandio M, Simonetti G, Romeo F, Mehta JL (2004) Evaluation of venous and arterial conduit patency by 16-slice spiral computed tomography. Circulation 110:3234–3238PubMedCrossRef
24.
Zurück zum Zitat Austen WG, Edwards JE, Frye RL, Gensini GG, Gott VL, Griffith LS, McGoon DC, Murphy ML, Roe BB (1975) A reporting system on patients evaluated for coronary artery disease. Report of the Ad Hoc Committee for Grading of Coronary Artery Disease, Council on Cardiovascular Surgery, American Heart Association. Circulation 51(4 Suppl):5–40PubMed Austen WG, Edwards JE, Frye RL, Gensini GG, Gott VL, Griffith LS, McGoon DC, Murphy ML, Roe BB (1975) A reporting system on patients evaluated for coronary artery disease. Report of the Ad Hoc Committee for Grading of Coronary Artery Disease, Council on Cardiovascular Surgery, American Heart Association. Circulation 51(4 Suppl):5–40PubMed
25.
Zurück zum Zitat van Ooijen PM, Dorgelo J, Zijlstra F, Oudkerk M (2004) Detection, visualization and evaluation of anomalous coronary anatomy on 16-slice multidetector-row CT. Eur Radiol 14(12):2163–2171PubMedCrossRef van Ooijen PM, Dorgelo J, Zijlstra F, Oudkerk M (2004) Detection, visualization and evaluation of anomalous coronary anatomy on 16-slice multidetector-row CT. Eur Radiol 14(12):2163–2171PubMedCrossRef
26.
Zurück zum Zitat Kuettner A, Trabold T, Schroeder S, Feyer A, Beck T, Brueckner A, Heuschmid M, Burgstahler C, Kopp AF, Claussen CD (2004) Noninvasive detection of coronary lesions using 16-detector multislice spiral computed tomography technology: initial clinical results. J Am Coll Cardiol 44(6):1230–1237PubMed Kuettner A, Trabold T, Schroeder S, Feyer A, Beck T, Brueckner A, Heuschmid M, Burgstahler C, Kopp AF, Claussen CD (2004) Noninvasive detection of coronary lesions using 16-detector multislice spiral computed tomography technology: initial clinical results. J Am Coll Cardiol 44(6):1230–1237PubMed
27.
Zurück zum Zitat Kuettner A, Beck T, Drosch T, Kettering K, Heuschmid M, Burgstahler C, Claussen CD, Kopp AF, Schroeder S (2005) Diagnostic accuracy of noninvasive coronary imaging using 16-detector slice spiral computed tomography with 188 ms temporal resolution. J Am Coll Cardiol 45(1):123–127PubMedCrossRef Kuettner A, Beck T, Drosch T, Kettering K, Heuschmid M, Burgstahler C, Claussen CD, Kopp AF, Schroeder S (2005) Diagnostic accuracy of noninvasive coronary imaging using 16-detector slice spiral computed tomography with 188 ms temporal resolution. J Am Coll Cardiol 45(1):123–127PubMedCrossRef
28.
Zurück zum Zitat Jakobs TF, Becker CR, Ohnesorge B, Flohr T, Suess C, Schoepf UJ, Reiser MF (2002) Multislice helical CT of the heart with retrospective ECG gating: reduction of radiation exposure by ECG-controlled tube current modulation. Eur Radiol 12(5):1081–1086PubMedCrossRef Jakobs TF, Becker CR, Ohnesorge B, Flohr T, Suess C, Schoepf UJ, Reiser MF (2002) Multislice helical CT of the heart with retrospective ECG gating: reduction of radiation exposure by ECG-controlled tube current modulation. Eur Radiol 12(5):1081–1086PubMedCrossRef
29.
Zurück zum Zitat Trabold T, Buchgeister M, Kuttner A, Heuschmid M, Kopp AF, Schroder S, Claussen CD (2003) Estimation of radiation exposure in 16-detector row computed tomography of the heart with retrospective ECG-gating. Fortschr Röntgenstr 175(8):1051–1055CrossRef Trabold T, Buchgeister M, Kuttner A, Heuschmid M, Kopp AF, Schroder S, Claussen CD (2003) Estimation of radiation exposure in 16-detector row computed tomography of the heart with retrospective ECG-gating. Fortschr Röntgenstr 175(8):1051–1055CrossRef
30.
Zurück zum Zitat Kuon E, Schmitt M, Dorn C, Pfahlberg A, Gefeller O, Dahm JB (2003) Predialing the number of cinegraphic frames enables an effective patient dose due to coronary angiography of 0.8 mSv. Fortschr Röntgenstr 175(12):1706–1710CrossRef Kuon E, Schmitt M, Dorn C, Pfahlberg A, Gefeller O, Dahm JB (2003) Predialing the number of cinegraphic frames enables an effective patient dose due to coronary angiography of 0.8 mSv. Fortschr Röntgenstr 175(12):1706–1710CrossRef
31.
Zurück zum Zitat Bourassa MG, Fisher LD, Campeau L, Gillespie MJ, McConney M, Lesperance J (1985) Long-term fate of bypass grafts: the Coronary Artery Surgery Study (CASS) and Montreal Heart Institute experiences. Circulation 72(6 pt 2):V71–V78PubMed Bourassa MG, Fisher LD, Campeau L, Gillespie MJ, McConney M, Lesperance J (1985) Long-term fate of bypass grafts: the Coronary Artery Surgery Study (CASS) and Montreal Heart Institute experiences. Circulation 72(6 pt 2):V71–V78PubMed
Metadaten
Titel
Coronary artery bypass grafts: assessment of graft patency and native coronary artery lesions using 16-slice MDCT
verfasst von
Norbert I. Stauder
Axel Küttner
Stephen Schröder
Tanja Drosch
Torsten Beck
Heidrun Stauder
Gunnar Blumenstock
Claus D. Claussen
Andreas F. Kopp
Publikationsdatum
01.11.2006
Verlag
Springer-Verlag
Erschienen in
European Radiology / Ausgabe 11/2006
Print ISSN: 0938-7994
Elektronische ISSN: 1432-1084
DOI
https://doi.org/10.1007/s00330-006-0268-4

Weitere Artikel der Ausgabe 11/2006

European Radiology 11/2006 Zur Ausgabe

Update Radiologie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.