The influence of various variables on the rate of pneumothorax and intrapulmonal hemorrhage associated with computed tomography (CT)-guided transthoracic needle biopsy of the lung were evaluated retrospectivly. One hundred and thirty-three patients underwent CT guided biopsy of a pulmonary lesion. Two patients were biopsied twice. Variables analyzed were lesion size, lesion location, number of pleural needle passes, lesion margin, length of intrapulmonal biopsy path and puncture time. Eighteen-gauge (18G) cutting needles (Trucut, Somatex, Teltow, Germany) were used for biopsy. Pneumothorax occured in 23 of 135 biopsies (17%). Chest tube placement was required in three out of 23 cases of pneumothorax (2% of all biopsies). Pneumothorax rate was significantly higher when the lesions were located in the lung parenchyma compared with locations at the pleura or chest wall (P < 0.05), but all pneumothorax cases which required chest tube treatment occured in lesions located less than 2 cm from the pleura. Longer puncture time led to an increase in pneumothorax rate (P < 0.05). Thirty-seven (27%) out of 135 biopsies showed perifocal hemorrhage. Intrapulmonal biopsy paths longer than 4 cm showed significantly higher numbers of perifocal hemorrhage and pneumothorax (P < 0.05). Significantly more hemorrhage occured when the pleura was penetrated twice during the puncture (P < 0.05). Lesion size <4 cm is strongly correlated with higher occurence of perifocal hemorrhage (P < 0.05). Lesion margination showed no significant effect on complication rate. CT-guided biopsy of smaller lesions correlates with a higher bleeding rate. Puncture time should be minimized to reduce pneumothorax rate. Passing the pleura twice significantly increases the risk of hemorrhage. Intrapulmonal biopsy paths longer than 4 cm showed significantly higher numbers of perifocal hemorrhage as well as pneumothorax.
Literatur
1.
Zurück zum Zitat Harter LP, Moss AA, Goldberg HI, Gross BH (1983) CT-guided fine-needle aspirations for diagnosis of benign and malignant disease. AJR Am J Roentgenol 140(2):363–367PubMed Harter LP, Moss AA, Goldberg HI, Gross BH (1983) CT-guided fine-needle aspirations for diagnosis of benign and malignant disease. AJR Am J Roentgenol 140(2):363–367PubMed
2.
Zurück zum Zitat Li H, Boiselle PM, Shepard JO, Trotman-Dickenson B, McLoud TC (1996) Diagnostic accuracy and safety of CT-guided percutaneous needle aspiration biopsy of the lung: comparison of small and large pulmonary nodules. AJR Am J Roentgenol 167(1):105–109PubMed Li H, Boiselle PM, Shepard JO, Trotman-Dickenson B, McLoud TC (1996) Diagnostic accuracy and safety of CT-guided percutaneous needle aspiration biopsy of the lung: comparison of small and large pulmonary nodules. AJR Am J Roentgenol 167(1):105–109PubMed
3.
Zurück zum Zitat Perlmutt LM, Johnston WW, Dunnick NR (1989) Percutaneous transthoracic needle aspiration: a review. AJR Am J Roentgenol 152(3):451–455PubMed Perlmutt LM, Johnston WW, Dunnick NR (1989) Percutaneous transthoracic needle aspiration: a review. AJR Am J Roentgenol 152(3):451–455PubMed
4.
Zurück zum Zitat Stanley JH, Fish GD, Andriole JG et al (1987) Lung lesions: cytologic diagnosis by fine-needle biopsy. Radiology 162(2):389–391PubMed Stanley JH, Fish GD, Andriole JG et al (1987) Lung lesions: cytologic diagnosis by fine-needle biopsy. Radiology 162(2):389–391PubMed
5.
Zurück zum Zitat Westcott JL (1988) Percutaneous transthoracic needle biopsy. Radiology 169(3):593–601PubMed Westcott JL (1988) Percutaneous transthoracic needle biopsy. Radiology 169(3):593–601PubMed
6.
Zurück zum Zitat Khouri NF, Stitik FP, Erozan YS et al (1985) Transthoracic needle aspiration biopsy of benign and malignant lung lesions. AJR Am J Roentgenol 144(2):281–288PubMed Khouri NF, Stitik FP, Erozan YS et al (1985) Transthoracic needle aspiration biopsy of benign and malignant lung lesions. AJR Am J Roentgenol 144(2):281–288PubMed
7.
Zurück zum Zitat Swischuk JL, Castaneda F, Patel JC et al (1998) Percutaneous transthoracic needle biopsy of the lung: review of 612 lesions. J Vasc Interv Radiol 9(2):347–352PubMedCrossRef Swischuk JL, Castaneda F, Patel JC et al (1998) Percutaneous transthoracic needle biopsy of the lung: review of 612 lesions. J Vasc Interv Radiol 9(2):347–352PubMedCrossRef
8.
Zurück zum Zitat Westcott JL, Rao N, Colley DP (1997) Transthoracic needle biopsy of small pulmonary nodules. Radiology 202(1):97–103PubMed Westcott JL, Rao N, Colley DP (1997) Transthoracic needle biopsy of small pulmonary nodules. Radiology 202(1):97–103PubMed
9.
Zurück zum Zitat Laurent F, Latrabe V, Vergier B, Montaudon M, Vernejoux JM, Dubrez J (2000) CT-guided transthoracic needle biopsy of pulmonary nodules smaller than 20 mm: results with an automated 20-gauge coaxial cutting needle. Clin Radiol 55(4):281–287CrossRefPubMed Laurent F, Latrabe V, Vergier B, Montaudon M, Vernejoux JM, Dubrez J (2000) CT-guided transthoracic needle biopsy of pulmonary nodules smaller than 20 mm: results with an automated 20-gauge coaxial cutting needle. Clin Radiol 55(4):281–287CrossRefPubMed
10.
Zurück zum Zitat Klein JS, Zarka MA (1997) Transthoracic needle biopsy: an overview. J Thorac Imaging 12(4):232–249PubMedCrossRef Klein JS, Zarka MA (1997) Transthoracic needle biopsy: an overview. J Thorac Imaging 12(4):232–249PubMedCrossRef
11.
Zurück zum Zitat Klein JS, Salomon G, Stewart EA (1996) Transthoracic needle biopsy with a coaxially placed 20-gauge automated cutting needle: results in 122 patients. Radiology 198(3):715–720PubMed Klein JS, Salomon G, Stewart EA (1996) Transthoracic needle biopsy with a coaxially placed 20-gauge automated cutting needle: results in 122 patients. Radiology 198(3):715–720PubMed
12.
Zurück zum Zitat Tsukada H, Satou T, Iwashima A, Souma T (2000) Diagnostic accuracy of CT-guided automated needle biopsy of lung nodules. AJR Am J Roentgenol 175(1):239–243PubMed Tsukada H, Satou T, Iwashima A, Souma T (2000) Diagnostic accuracy of CT-guided automated needle biopsy of lung nodules. AJR Am J Roentgenol 175(1):239–243PubMed
13.
Zurück zum Zitat vanSonnenberg E, Lin AS, Deutsch AL, Mattrey RF (1983) Percutaneous biopsy of difficult mediastinal, hilar, and pulmonary lesions by computed tomographic guidance and a modified coaxial technique. Radiology 148(1):300–302PubMed vanSonnenberg E, Lin AS, Deutsch AL, Mattrey RF (1983) Percutaneous biopsy of difficult mediastinal, hilar, and pulmonary lesions by computed tomographic guidance and a modified coaxial technique. Radiology 148(1):300–302PubMed
14.
Zurück zum Zitat Larscheid RC, Thorpe PE, Scott WJ (1998) Percutaneous transthoracic needle aspiration biopsy: a comprehensive review of its current role in the diagnosis and treatment of lung tumors. Chest 114(3):704–709CrossRefPubMed Larscheid RC, Thorpe PE, Scott WJ (1998) Percutaneous transthoracic needle aspiration biopsy: a comprehensive review of its current role in the diagnosis and treatment of lung tumors. Chest 114(3):704–709CrossRefPubMed
15.
Zurück zum Zitat Kazerooni EA, Lim FT, Mikhail A, Martinez FJ (1996) Risk of pneumothorax in CT-guided transthoracic needle aspiration biopsy of the lung. Radiology 198(2):371–375PubMed Kazerooni EA, Lim FT, Mikhail A, Martinez FJ (1996) Risk of pneumothorax in CT-guided transthoracic needle aspiration biopsy of the lung. Radiology 198(2):371–375PubMed
16.
Zurück zum Zitat Geraghty PR, Kee ST, McFarlane G, Razavi MK, Sze DY, Dake MD (2003) CT-guided transthoracic needle aspiration biopsy of pulmonary nodules: needle size and pneumothorax rate. Radiology 229(2):475–481CrossRefPubMed Geraghty PR, Kee ST, McFarlane G, Razavi MK, Sze DY, Dake MD (2003) CT-guided transthoracic needle aspiration biopsy of pulmonary nodules: needle size and pneumothorax rate. Radiology 229(2):475–481CrossRefPubMed
17.
Zurück zum Zitat Cox JE, Chiles C, McManus CM, Aquino SL, Choplin RH (1999) Transthoracic needle aspiration biopsy: variables that affect risk of pneumothorax. Radiology 212(1):165–168PubMed Cox JE, Chiles C, McManus CM, Aquino SL, Choplin RH (1999) Transthoracic needle aspiration biopsy: variables that affect risk of pneumothorax. Radiology 212(1):165–168PubMed
18.
Zurück zum Zitat Laurent F, Michel P, Latrabe V, Tunon de Lara M, Marthan R (1999) Pneumothoraces and chest tube placement after CT-guided transthoracic lung biopsy using a coaxial technique: incidence and risk factors. AJR Am J Roentgenol 172(4):1049–1153PubMed Laurent F, Michel P, Latrabe V, Tunon de Lara M, Marthan R (1999) Pneumothoraces and chest tube placement after CT-guided transthoracic lung biopsy using a coaxial technique: incidence and risk factors. AJR Am J Roentgenol 172(4):1049–1153PubMed
19.
Zurück zum Zitat Yamagami T, Nakamura T, Iida S, Kato T, Nishimura T (2002) Management of pneumothorax after percutaneous CT-guided lung biopsy. Chest 121(4):1159–1164CrossRefPubMed Yamagami T, Nakamura T, Iida S, Kato T, Nishimura T (2002) Management of pneumothorax after percutaneous CT-guided lung biopsy. Chest 121(4):1159–1164CrossRefPubMed
20.
Zurück zum Zitat Sinner WN (1976) Complications of percutaneous transthoracic needle aspiration biopsy. Acta Radiol Diagn (Stockh) 17(6):813–828 Sinner WN (1976) Complications of percutaneous transthoracic needle aspiration biopsy. Acta Radiol Diagn (Stockh) 17(6):813–828
21.
Zurück zum Zitat Muller NL, Bergin CJ, Miller RR, Ostrow DN (1986) Seeding of malignant cells into the needle track after lung and pleural biopsy. Can Assoc Radiol J 37(3):192–194PubMed Muller NL, Bergin CJ, Miller RR, Ostrow DN (1986) Seeding of malignant cells into the needle track after lung and pleural biopsy. Can Assoc Radiol J 37(3):192–194PubMed
22.
Zurück zum Zitat Graham RJ, Heyd RL, Raval VA, Barrett TF (1992) Lung torsion after percutaneous needle biopsy of lung. AJR Am J Roentgenol 159(1):35–37PubMed Graham RJ, Heyd RL, Raval VA, Barrett TF (1992) Lung torsion after percutaneous needle biopsy of lung. AJR Am J Roentgenol 159(1):35–37PubMed
23.
Zurück zum Zitat Tolly TL, Feldmeier JE, Czarnecki D (1988) Air embolism complicating percutaneous lung biopsy. AJR Am J Roentgenol 150(3):555–556PubMed Tolly TL, Feldmeier JE, Czarnecki D (1988) Air embolism complicating percutaneous lung biopsy. AJR Am J Roentgenol 150(3):555–556PubMed
24.
Zurück zum Zitat Laurent F, Latrabe V, Vergier B, Michel P (2000) Percutaneous CT-guided biopsy of the lung: comparison between aspiration and automated cutting needles using a coaxial technique. Cardiovasc Intervent Radiol 23(4):266–272CrossRefPubMed Laurent F, Latrabe V, Vergier B, Michel P (2000) Percutaneous CT-guided biopsy of the lung: comparison between aspiration and automated cutting needles using a coaxial technique. Cardiovasc Intervent Radiol 23(4):266–272CrossRefPubMed
25.
Zurück zum Zitat Haramati LB, Austin JH (1991) Complications after CT-guided needle biopsy through aerated versus nonaerated lung. Radiology 181(3):778PubMed Haramati LB, Austin JH (1991) Complications after CT-guided needle biopsy through aerated versus nonaerated lung. Radiology 181(3):778PubMed
26.
Zurück zum Zitat Gupta S, Krishnamurthy S, Broemeling LD et al (2005) Small (</=2-cm) subpleural pulmonary lesions: short- versus long-needle-path CT-guided biopsy–comparison of diagnostic yields and complications. Radiology 234(2):631–637CrossRefPubMed Gupta S, Krishnamurthy S, Broemeling LD et al (2005) Small (</=2-cm) subpleural pulmonary lesions: short- versus long-needle-path CT-guided biopsy–comparison of diagnostic yields and complications. Radiology 234(2):631–637CrossRefPubMed
27.
Zurück zum Zitat Yeow KM, Su IH, Pan KT et al (2004) Risk factors of pneumothorax and bleeding: multivariate analysis of 660 CT-guided coaxial cutting needle lung biopsies. Chest 126(3):748–754CrossRefPubMed Yeow KM, Su IH, Pan KT et al (2004) Risk factors of pneumothorax and bleeding: multivariate analysis of 660 CT-guided coaxial cutting needle lung biopsies. Chest 126(3):748–754CrossRefPubMed
28.
Zurück zum Zitat Fink I, Gamsu G, Harter LP (1982) CT-guided aspiration biopsy of the thorax. J Comput Assist Tomogr 6(5):958–962CrossRefPubMed Fink I, Gamsu G, Harter LP (1982) CT-guided aspiration biopsy of the thorax. J Comput Assist Tomogr 6(5):958–962CrossRefPubMed
29.
Zurück zum Zitat Ohno Y, Hatabu H, Takenaka D et al (2003) CT-guided transthoracic needle aspiration biopsy of small (< or = 20 mm) solitary pulmonary nodules. AJR Am J Roentgenol 180(6):1665–1669PubMed Ohno Y, Hatabu H, Takenaka D et al (2003) CT-guided transthoracic needle aspiration biopsy of small (< or = 20 mm) solitary pulmonary nodules. AJR Am J Roentgenol 180(6):1665–1669PubMed
30.
Zurück zum Zitat Moore EH, LeBlanc J, Montesi SA, Richardson ML, Shepard JA, McLoud TC (1991) Effect of patient positioning after needle aspiration lung biopsy. Radiology 181(2):385–387PubMed Moore EH, LeBlanc J, Montesi SA, Richardson ML, Shepard JA, McLoud TC (1991) Effect of patient positioning after needle aspiration lung biopsy. Radiology 181(2):385–387PubMed
31.
Zurück zum Zitat Yeow KM, See LC, Lui KW et al (2001) Risk factors for pneumothorax and bleeding after CT-guided percutaneous coaxial cutting needle biopsy of lung lesions. J Vasc Interv Radiol 12(11):1305–1312CrossRefPubMed Yeow KM, See LC, Lui KW et al (2001) Risk factors for pneumothorax and bleeding after CT-guided percutaneous coaxial cutting needle biopsy of lung lesions. J Vasc Interv Radiol 12(11):1305–1312CrossRefPubMed
32.
Zurück zum Zitat Wallace MJ, Krishnamurthy S, Broemeling LD et al (2002) CT-guided percutaneous fine-needle aspiration biopsy of small (< or =1-cm) pulmonary lesions. Radiology 225(3):823–828CrossRefPubMed Wallace MJ, Krishnamurthy S, Broemeling LD et al (2002) CT-guided percutaneous fine-needle aspiration biopsy of small (< or =1-cm) pulmonary lesions. Radiology 225(3):823–828CrossRefPubMed
33.
Zurück zum Zitat Ko JP, Shepard JO, Drucker EA et al (2001) Factors influencing pneumothorax rate at lung biopsy: are dwell time and angle of pleural puncture contributing factors? Radiology 218(2):491–496PubMed Ko JP, Shepard JO, Drucker EA et al (2001) Factors influencing pneumothorax rate at lung biopsy: are dwell time and angle of pleural puncture contributing factors? Radiology 218(2):491–496PubMed
34.
Zurück zum Zitat Kinoshita F, Kato T, Sugiura K et al (2006) CT-guided transthoracic needle biopsy using a puncture site-down positioning technique. AJR Am J Roentgenol 187(4):926–932CrossRefPubMed Kinoshita F, Kato T, Sugiura K et al (2006) CT-guided transthoracic needle biopsy using a puncture site-down positioning technique. AJR Am J Roentgenol 187(4):926–932CrossRefPubMed
35.
Zurück zum Zitat Topal U, Ediz B (2003) Transthoracic needle biopsy: factors effecting risk of pneumothorax. Eur J Radiol 48(3):263–267CrossRefPubMed Topal U, Ediz B (2003) Transthoracic needle biopsy: factors effecting risk of pneumothorax. Eur J Radiol 48(3):263–267CrossRefPubMed
36.
Zurück zum Zitat Miller KS, Fish GB, Stanley JH, Schabel SI (1988) Prediction of pneumothorax rate in percutaneous needle aspiration of the lung. Chest 93(4):742–745CrossRefPubMed Miller KS, Fish GB, Stanley JH, Schabel SI (1988) Prediction of pneumothorax rate in percutaneous needle aspiration of the lung. Chest 93(4):742–745CrossRefPubMed
37.
Zurück zum Zitat Fish GD, Stanley JH, Miller KS, Schabel SI, Sutherland SE (1988) Postbiopsy pneumothorax: estimating the risk by chest radiography and pulmonary function tests. AJR Am J Roentgenol 150(1):71–74PubMed Fish GD, Stanley JH, Miller KS, Schabel SI, Sutherland SE (1988) Postbiopsy pneumothorax: estimating the risk by chest radiography and pulmonary function tests. AJR Am J Roentgenol 150(1):71–74PubMed
38.
Zurück zum Zitat Poe RH, Kallay MC, Wicks CM, Odoroff CL (1984) Predicting risk of pneumothorax in needle biopsy of the lung. Chest 85(2):232–235CrossRefPubMed Poe RH, Kallay MC, Wicks CM, Odoroff CL (1984) Predicting risk of pneumothorax in needle biopsy of the lung. Chest 85(2):232–235CrossRefPubMed
39.
Zurück zum Zitat Topal U, Berkman YM (2005) Effect of needle tract bleeding on occurrence of pneumothorax after transthoracic needle biopsy. Eur J Radiol 53(3):495–499CrossRefPubMed Topal U, Berkman YM (2005) Effect of needle tract bleeding on occurrence of pneumothorax after transthoracic needle biopsy. Eur J Radiol 53(3):495–499CrossRefPubMed
40.
Zurück zum Zitat Swensen SJ, Viggiano RW, Midthun DE et al (2000) Lung nodule enhancement at CT: multicenter study. Radiology 214(1):73–80PubMed Swensen SJ, Viggiano RW, Midthun DE et al (2000) Lung nodule enhancement at CT: multicenter study. Radiology 214(1):73–80PubMed
Metadaten
Titel
Variables affecting the risk of pneumothorax and intrapulmonal hemorrhage in CT-guided transthoracic biopsy
verfasst von
M. F. Khan
R. Straub
S. R. Moghaddam
A. Maataoui
J. Gurung
T. O. F. Wagner
H. Ackermann
A. Thalhammer
T. J. Vogl
V. Jacobi
Publikationsdatum
01.07.2008
Verlag
Springer-Verlag
Erschienen in
European Radiology / Ausgabe 7/2008
Print ISSN: 0938-7994
Elektronische ISSN: 1432-1084
DOI
https://doi.org/10.1007/s00330-008-0893-1

Weitere Artikel der Ausgabe 7/2008

European Radiology 7/2008 Zur Ausgabe

Update Radiologie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.