Abstract

Ultrasound-guided, large-core needle biopsy (US-LCNB) of suspicious breast lesions is acknowledged as less invasive and less expensive and less time consuming than surgical biopsy, and provides a histologic diagnosis with a comparable high degree. US-LCNB has been proven to help reduce the number of unnecessary surgeries for benign disease. Its limitations, however, are false-negative results and underestimation of disease. Thus, the demand for breast teams is to carefully adhere to the principles of triple assessment and imaging-histologic correlation, and follow-up of lesions with a specific benign histology after biopsy. Also, the acceptance of guidelines and rigorous quality controls help to reliably minimize the delay in the diagnosis of breast cancer in patients with false-negative biopsies. This paper aims to summarize the equipment and methods as well as the benefits and limitations of US-LCNB. Also, guidelines of quality assessment are suggested. Finally, recent developments which may help to overcome the limitations of US-LCNB will be discussed, i.e., directional vacuum-assisted biopsy (VAB), three-dimensional (3D) US-guided biopsy, as well as the use of tissue harmonic imaging (THI) and compound imaging (CI) during biopsy.
Literatur
1.
Zurück zum Zitat American Cancer Society (2006) Cancer facts & figures. American Cancer Society, Oakland American Cancer Society (2006) Cancer facts & figures. American Cancer Society, Oakland
2.
Zurück zum Zitat Parikh J, Tickman R (2005) Image-guided tissue sampling: where radiology meets pathology. Breast J 11:403–409PubMedCrossRef Parikh J, Tickman R (2005) Image-guided tissue sampling: where radiology meets pathology. Breast J 11:403–409PubMedCrossRef
3.
Zurück zum Zitat Tabar L, Vitak B, Chen HH, Yen MF, Duffy SW, Smith RA (2001) Beyond randomized controlled trials: organized mammographic screening substantially reduces breast carcinoma mortality. Cancer 91:1724–1731PubMedCrossRef Tabar L, Vitak B, Chen HH, Yen MF, Duffy SW, Smith RA (2001) Beyond randomized controlled trials: organized mammographic screening substantially reduces breast carcinoma mortality. Cancer 91:1724–1731PubMedCrossRef
4.
Zurück zum Zitat Leconte I, Feger C, Galant C et al (2003) Mammography and subsequent whole-breast sonography of nonpalpable breast cancers: the importance of radiologic breast density. AJR Am J Roentgenol 180:1675–1679PubMed Leconte I, Feger C, Galant C et al (2003) Mammography and subsequent whole-breast sonography of nonpalpable breast cancers: the importance of radiologic breast density. AJR Am J Roentgenol 180:1675–1679PubMed
5.
Zurück zum Zitat Kolb TM, Lichy J, Newhouse JH (2002) Comparison of the performance of screening mammography, physical examination, and breast US and evaluation of factors that influence them: an analysis of 27,825 patient evaluations. Radiology 225:165–175PubMedCrossRef Kolb TM, Lichy J, Newhouse JH (2002) Comparison of the performance of screening mammography, physical examination, and breast US and evaluation of factors that influence them: an analysis of 27,825 patient evaluations. Radiology 225:165–175PubMedCrossRef
6.
Zurück zum Zitat American College of Radiology (2003) Illustrated breast imaging reporting and data system (BI-RADS), 4th edn. ACR, Reston American College of Radiology (2003) Illustrated breast imaging reporting and data system (BI-RADS), 4th edn. ACR, Reston
7.
Zurück zum Zitat Pijnappel RM, van den Donk M, Holland R et al (2004) Diagnostic accuracy for different strategies of image-guided breast intervention in cases of nonpalpable breast lesions. Br J Cancer 90:595–600PubMedCrossRef Pijnappel RM, van den Donk M, Holland R et al (2004) Diagnostic accuracy for different strategies of image-guided breast intervention in cases of nonpalpable breast lesions. Br J Cancer 90:595–600PubMedCrossRef
8.
Zurück zum Zitat Parker SH, Burbank F, Jackman RJ et al (1994) Percutaneous large-core breast biopsy: a multi-institutional study. Radiology 193:359–364PubMed Parker SH, Burbank F, Jackman RJ et al (1994) Percutaneous large-core breast biopsy: a multi-institutional study. Radiology 193:359–364PubMed
9.
Zurück zum Zitat Helbich TH, Mayr W, Schick S et al (1997) Coaxial technique: approach to breast core biopsies. Radiology 203:684–690PubMed Helbich TH, Mayr W, Schick S et al (1997) Coaxial technique: approach to breast core biopsies. Radiology 203:684–690PubMed
10.
Zurück zum Zitat Smith DN, Rosenfield Darling ML, Meyer JE et al (2001) The utility of ultrasonographically guided large-core needle biopsy: results from 500 consecutive breast biopsies. J Ultrasound Med 20:43–49PubMed Smith DN, Rosenfield Darling ML, Meyer JE et al (2001) The utility of ultrasonographically guided large-core needle biopsy: results from 500 consecutive breast biopsies. J Ultrasound Med 20:43–49PubMed
11.
Zurück zum Zitat Sauer G, Deissler H, Strunz K et al (2005) Ultrasound-guided large-core needle biopsies of breast lesions: analysis of 962 cases to determine the number of samples for reliable tumour classification. Br J Cancer 92:231–235PubMed Sauer G, Deissler H, Strunz K et al (2005) Ultrasound-guided large-core needle biopsies of breast lesions: analysis of 962 cases to determine the number of samples for reliable tumour classification. Br J Cancer 92:231–235PubMed
12.
Zurück zum Zitat Liberman L, Feng TL, Dershaw DD, Morris EA, Abramson AF (1998) US-guided core breast biopsy: use and cost-effectiveness. Radiology 208:717–723PubMed Liberman L, Feng TL, Dershaw DD, Morris EA, Abramson AF (1998) US-guided core breast biopsy: use and cost-effectiveness. Radiology 208:717–723PubMed
13.
Zurück zum Zitat Crystal P, Koretz M, Shcharynsky S, Makarov V, Strano S (2005) Accuracy of sonographically guided 14-gauge core-needle biopsy: results of 715 consecutive breast biopsies with at least two-year follow-up of benign lesions. J Clin Ultrasound 33:47–52PubMedCrossRef Crystal P, Koretz M, Shcharynsky S, Makarov V, Strano S (2005) Accuracy of sonographically guided 14-gauge core-needle biopsy: results of 715 consecutive breast biopsies with at least two-year follow-up of benign lesions. J Clin Ultrasound 33:47–52PubMedCrossRef
14.
Zurück zum Zitat Mainiero MB, Gareen IF, Bird CE, Smith W, Cobb C, Schepps B (2002) Preferential use of sonographically guided biopsy to minimize patient discomfort and procedure time in a percutaneous image-guided breast biopsy program. J Ultrasound Med 21:1221–1226PubMed Mainiero MB, Gareen IF, Bird CE, Smith W, Cobb C, Schepps B (2002) Preferential use of sonographically guided biopsy to minimize patient discomfort and procedure time in a percutaneous image-guided breast biopsy program. J Ultrasound Med 21:1221–1226PubMed
15.
Zurück zum Zitat Collins LC, Connolly JL, Page DL et al (2004) Diagnostic agreement in the evaluation of image-guided breast core needle biopsies: results from a randomized clinical trial. Am J Surg Pathol 28:126–131PubMedCrossRef Collins LC, Connolly JL, Page DL et al (2004) Diagnostic agreement in the evaluation of image-guided breast core needle biopsies: results from a randomized clinical trial. Am J Surg Pathol 28:126–131PubMedCrossRef
16.
Zurück zum Zitat Vargas HI, Vargas MP, Gonzalez KD et al (2004) Diagnosis of palpable breast masses: ultrasound-guided large core biopsy in a multidisciplinary setting. Am Surg 70:867–871PubMed Vargas HI, Vargas MP, Gonzalez KD et al (2004) Diagnosis of palpable breast masses: ultrasound-guided large core biopsy in a multidisciplinary setting. Am Surg 70:867–871PubMed
17.
Zurück zum Zitat Helbich TH, Matzek W, Fuchsjager MH (2004) Stereotactic and ultrasound-guided breast biopsy. Eur Radiol 14:383–393PubMedCrossRef Helbich TH, Matzek W, Fuchsjager MH (2004) Stereotactic and ultrasound-guided breast biopsy. Eur Radiol 14:383–393PubMedCrossRef
18.
Zurück zum Zitat Shulman SG, March DE (2006) Ultrasound-guided breast interventions: accuracy of biopsy techniques and applications in patient management. Semin Ultrasound CT MR 27:298–307PubMedCrossRef Shulman SG, March DE (2006) Ultrasound-guided breast interventions: accuracy of biopsy techniques and applications in patient management. Semin Ultrasound CT MR 27:298–307PubMedCrossRef
19.
Zurück zum Zitat Dillon MF, Hill AD, Quinn CM, O’Doherty A, McDermott EW, O’Higgins N (2005) The accuracy of ultrasound, stereotactic, and clinical core biopsies in the diagnosis of breast cancer, with an analysis of false-negative cases. Ann Surg 242:701–707PubMedCrossRef Dillon MF, Hill AD, Quinn CM, O’Doherty A, McDermott EW, O’Higgins N (2005) The accuracy of ultrasound, stereotactic, and clinical core biopsies in the diagnosis of breast cancer, with an analysis of false-negative cases. Ann Surg 242:701–707PubMedCrossRef
20.
Zurück zum Zitat Schulz-Wendtland R, Kramer S, Lang N, Bautz W (1998) Ultrasonic guided microbiopsy in mammary diagnosis: indications, technique and results. Anticancer Res 18:2145–2146PubMed Schulz-Wendtland R, Kramer S, Lang N, Bautz W (1998) Ultrasonic guided microbiopsy in mammary diagnosis: indications, technique and results. Anticancer Res 18:2145–2146PubMed
21.
Zurück zum Zitat Schoonjans JM, Brem RF (2001) Fourteen-gauge ultrasonographically guided large-core needle biopsy of breast masses. J Ultrasound Med 20:967–972PubMed Schoonjans JM, Brem RF (2001) Fourteen-gauge ultrasonographically guided large-core needle biopsy of breast masses. J Ultrasound Med 20:967–972PubMed
22.
Zurück zum Zitat Buchberger W, Niehoff A, Obrist P, Rettl G, Dunser M (2002) [Sonographically guided core needle biopsy of the breast: technique, accuracy and indications]. Radiologe 42:25–32PubMedCrossRef Buchberger W, Niehoff A, Obrist P, Rettl G, Dunser M (2002) [Sonographically guided core needle biopsy of the breast: technique, accuracy and indications]. Radiologe 42:25–32PubMedCrossRef
23.
Zurück zum Zitat Perry NM (2001) Quality assurance in the diagnosis of breast disease. EUSOMA Working Party. Eur J Cancer 37:159–172PubMedCrossRef Perry NM (2001) Quality assurance in the diagnosis of breast disease. EUSOMA Working Party. Eur J Cancer 37:159–172PubMedCrossRef
24.
Zurück zum Zitat Helbich TH, Rudas M, Haitel A et al (1998) Evaluation of needle size for breast biopsy: comparison of 14-, 16-, and 18-gauge biopsy needles. AJR Am J Roentgenol 171:59–63PubMed Helbich TH, Rudas M, Haitel A et al (1998) Evaluation of needle size for breast biopsy: comparison of 14-, 16-, and 18-gauge biopsy needles. AJR Am J Roentgenol 171:59–63PubMed
25.
Zurück zum Zitat Helbich TH, Rudas M, Bohm G et al (1999) Randomized in vitro and in vivo evaluation of different biopsy needles and devices for breast biopsy. Clin Radiol 54:56–62PubMedCrossRef Helbich TH, Rudas M, Bohm G et al (1999) Randomized in vitro and in vivo evaluation of different biopsy needles and devices for breast biopsy. Clin Radiol 54:56–62PubMedCrossRef
26.
Zurück zum Zitat Memarsadeghi M, Pfarl G, Riedl C, Wagner T, Rudas M, Helbich TH (2003) [Value of 14-gauge ultrasound-guided large-core needle biopsy of breast lesions: own results in comparison with the literature]. Rofo 175:374–380PubMed Memarsadeghi M, Pfarl G, Riedl C, Wagner T, Rudas M, Helbich TH (2003) [Value of 14-gauge ultrasound-guided large-core needle biopsy of breast lesions: own results in comparison with the literature]. Rofo 175:374–380PubMed
27.
Zurück zum Zitat Liberman L (2000) Clinical management issues in percutaneous core breast biopsy. Radiol Clin North Am 38:791–807PubMedCrossRef Liberman L (2000) Clinical management issues in percutaneous core breast biopsy. Radiol Clin North Am 38:791–807PubMedCrossRef
28.
Zurück zum Zitat Schueller G, Jaromi S, Ponhold L et al (2008) Ultrasound-guided, 14-gauge, core needle breast biopsy: a validation study in 1,352 cases. Radiology (in press) Schueller G, Jaromi S, Ponhold L et al (2008) Ultrasound-guided, 14-gauge, core needle breast biopsy: a validation study in 1,352 cases. Radiology (in press)
29.
Zurück zum Zitat Heywang-Köbrunner SH (2001) Diagnostic Breast Imaging. Thieme, Stuttgart New York Heywang-Köbrunner SH (2001) Diagnostic Breast Imaging. Thieme, Stuttgart New York
30.
Zurück zum Zitat Youk JH, Kim EK, Kim MJ, Lee JY, Oh KK (2007) Missed breast cancers at US-guided core needle biopsy: how to reduce them. Radiographics 27:79–94PubMedCrossRef Youk JH, Kim EK, Kim MJ, Lee JY, Oh KK (2007) Missed breast cancers at US-guided core needle biopsy: how to reduce them. Radiographics 27:79–94PubMedCrossRef
31.
Zurück zum Zitat Liberman L, LaTrenta LR, Dershaw DD (1997) Impact of core biopsy on the surgical management of impalpable breast cancer: another look at margins. AJR Am J Roentgenol 169:1464–1465PubMed Liberman L, LaTrenta LR, Dershaw DD (1997) Impact of core biopsy on the surgical management of impalpable breast cancer: another look at margins. AJR Am J Roentgenol 169:1464–1465PubMed
32.
Zurück zum Zitat Wu YC, Chen DR, Kuo SJ (2006) Personal experience of ultrasound-guided 14-gauge core biopsy of breast tumor. Eur J Surg Oncol 32:715–718PubMedCrossRef Wu YC, Chen DR, Kuo SJ (2006) Personal experience of ultrasound-guided 14-gauge core biopsy of breast tumor. Eur J Surg Oncol 32:715–718PubMedCrossRef
33.
Zurück zum Zitat Cardenosa G (1999) Needle choice for sonographically guided core biopsy. AJR Am J Roentgenol 173:845–846PubMed Cardenosa G (1999) Needle choice for sonographically guided core biopsy. AJR Am J Roentgenol 173:845–846PubMed
34.
Zurück zum Zitat Fishman JE, Milikowski C, Ramsinghani R, Velasquez MV, Aviram G (2003) US-guided core-needle biopsy of the breast: how many specimens are necessary? Radiology 226:779–782PubMedCrossRef Fishman JE, Milikowski C, Ramsinghani R, Velasquez MV, Aviram G (2003) US-guided core-needle biopsy of the breast: how many specimens are necessary? Radiology 226:779–782PubMedCrossRef
35.
Zurück zum Zitat Helbich TH, Buchberger W, Rudas M (2002) [Stereotactically and sonographically guided vacuum-assisted breast biopsy: a national consensus for Austria]. Rofo 174:517–522PubMed Helbich TH, Buchberger W, Rudas M (2002) [Stereotactically and sonographically guided vacuum-assisted breast biopsy: a national consensus for Austria]. Rofo 174:517–522PubMed
36.
Zurück zum Zitat Liberman L, LaTrenta LR, Dershaw DD et al (1997) Impact of core biopsy on the surgical management of impalpable breast cancer. AJR Am J Roentgenol 168:495–499PubMed Liberman L, LaTrenta LR, Dershaw DD et al (1997) Impact of core biopsy on the surgical management of impalpable breast cancer. AJR Am J Roentgenol 168:495–499PubMed
37.
Zurück zum Zitat Simon JR, Kalbhen CL, Cooper RA, Flisak ME (2000) Accuracy and complication rates of US-guided vacuum-assisted core breast biopsy: initial results. Radiology 215:694–697PubMed Simon JR, Kalbhen CL, Cooper RA, Flisak ME (2000) Accuracy and complication rates of US-guided vacuum-assisted core breast biopsy: initial results. Radiology 215:694–697PubMed
38.
Zurück zum Zitat Philpotts LE, Hooley RJ, Lee CH (2003) Comparison of automated versus vacuum-assisted biopsy methods for sonographically guided core biopsy of the breast. AJR Am J Roentgenol 180:347–351PubMed Philpotts LE, Hooley RJ, Lee CH (2003) Comparison of automated versus vacuum-assisted biopsy methods for sonographically guided core biopsy of the breast. AJR Am J Roentgenol 180:347–351PubMed
39.
Zurück zum Zitat Cho N, Moon WK, Cha JH et al (2005) Sonographically guided core biopsy of the breast: comparison of 14-gauge automated gun and 11-gauge directional vacuum-assisted biopsy methods. Korean J Radiol 6:102–109PubMedCrossRef Cho N, Moon WK, Cha JH et al (2005) Sonographically guided core biopsy of the breast: comparison of 14-gauge automated gun and 11-gauge directional vacuum-assisted biopsy methods. Korean J Radiol 6:102–109PubMedCrossRef
40.
Zurück zum Zitat Sperber F, Blank A, Metser U, Flusser G, Klausner JM, Lev-Chelouche D (2003) Diagnosis and treatment of breast fibroadenomas by ultrasound-guided vacuum-assisted biopsy. Arch Surg 138:796–800PubMedCrossRef Sperber F, Blank A, Metser U, Flusser G, Klausner JM, Lev-Chelouche D (2003) Diagnosis and treatment of breast fibroadenomas by ultrasound-guided vacuum-assisted biopsy. Arch Surg 138:796–800PubMedCrossRef
41.
Zurück zum Zitat Alonso-Bartolome P, Vega-Bolivar A, Torres-Tabanera M et al (2004) Sonographically guided 11-G directional vacuum-assisted breast biopsy as an alternative to surgical excision: utility and cost study in probably benign lesions. Acta Radiol 45:390–396PubMedCrossRef Alonso-Bartolome P, Vega-Bolivar A, Torres-Tabanera M et al (2004) Sonographically guided 11-G directional vacuum-assisted breast biopsy as an alternative to surgical excision: utility and cost study in probably benign lesions. Acta Radiol 45:390–396PubMedCrossRef
42.
Zurück zum Zitat Kim MJ, Kim EK, Lee JY et al (2007) Breast lesions with imaging-histologic discordance during US-guided 14G automated core biopsy: can the directional vacuum-assisted removal replace the surgical excision? Initial findings. Eur Radiol 17:2376–2383PubMedCrossRef Kim MJ, Kim EK, Lee JY et al (2007) Breast lesions with imaging-histologic discordance during US-guided 14G automated core biopsy: can the directional vacuum-assisted removal replace the surgical excision? Initial findings. Eur Radiol 17:2376–2383PubMedCrossRef
43.
Zurück zum Zitat Fine RE, Whitworth PW, Kim JA, Harness JK, Boyd BA, Burak WE Jr. (2003) Low-risk palpable breast masses removed using a vacuum-assisted hand-held device. Am J Surg 186:362–367PubMedCrossRef Fine RE, Whitworth PW, Kim JA, Harness JK, Boyd BA, Burak WE Jr. (2003) Low-risk palpable breast masses removed using a vacuum-assisted hand-held device. Am J Surg 186:362–367PubMedCrossRef
44.
Zurück zum Zitat March DE, Coughlin BF, Barham RB et al (2003) Breast masses: removal of all US evidence during biopsy by using a handheld vacuum-assisted device—initial experience. Radiology 227:549–555PubMedCrossRef March DE, Coughlin BF, Barham RB et al (2003) Breast masses: removal of all US evidence during biopsy by using a handheld vacuum-assisted device—initial experience. Radiology 227:549–555PubMedCrossRef
45.
Zurück zum Zitat Parker SH, Klaus AJ, McWey PJ et al (2001) Sonographically guided directional vacuum-assisted breast biopsy using a handheld device. AJR Am J Roentgenol 177:405–408PubMed Parker SH, Klaus AJ, McWey PJ et al (2001) Sonographically guided directional vacuum-assisted breast biopsy using a handheld device. AJR Am J Roentgenol 177:405–408PubMed
46.
Zurück zum Zitat Chen SC, Yang HR, Hwang TL, Chen MF, Cheung YC, Hsueh S (2003) Intraoperative ultrasonographically guided excisional biopsy or vacuum-assisted core needle biopsy for nonpalpable breast lesions. Ann Surg 238:738–742PubMedCrossRef Chen SC, Yang HR, Hwang TL, Chen MF, Cheung YC, Hsueh S (2003) Intraoperative ultrasonographically guided excisional biopsy or vacuum-assisted core needle biopsy for nonpalpable breast lesions. Ann Surg 238:738–742PubMedCrossRef
47.
Zurück zum Zitat Huber S, Wagner M, Medl M, Czembirek H (2003) Benign breast lesions: minimally invasive vacuum-assisted biopsy with 11-gauge needles patient acceptance and effect on follow-up imaging findings. Radiology 226:783–790PubMedCrossRef Huber S, Wagner M, Medl M, Czembirek H (2003) Benign breast lesions: minimally invasive vacuum-assisted biopsy with 11-gauge needles patient acceptance and effect on follow-up imaging findings. Radiology 226:783–790PubMedCrossRef
48.
Zurück zum Zitat Cassano E, Urban LA, Pizzamiglio M et al (2007) Ultrasound-guided vacuum-assisted core breast biopsy: experience with 406 cases. Breast Cancer Res Treat 102:103–110PubMedCrossRef Cassano E, Urban LA, Pizzamiglio M et al (2007) Ultrasound-guided vacuum-assisted core breast biopsy: experience with 406 cases. Breast Cancer Res Treat 102:103–110PubMedCrossRef
49.
Zurück zum Zitat Grady I, Gorsuch H, Wilburn-Bailey S (2005) Ultrasound-guided, vacuum-assisted, percutaneous excision of breast lesions: an accurate technique in the diagnosis of atypical ductal hyperplasia. J Am Coll Surg 201:14–17PubMedCrossRef Grady I, Gorsuch H, Wilburn-Bailey S (2005) Ultrasound-guided, vacuum-assisted, percutaneous excision of breast lesions: an accurate technique in the diagnosis of atypical ductal hyperplasia. J Am Coll Surg 201:14–17PubMedCrossRef
50.
Zurück zum Zitat Wallis M, Tardivon A, Helbich T, Schreer I (2007) Guidelines from the European Society of Breast Imaging for diagnostic interventional breast procedures. Eur Radiol 17:581–588PubMedCrossRef Wallis M, Tardivon A, Helbich T, Schreer I (2007) Guidelines from the European Society of Breast Imaging for diagnostic interventional breast procedures. Eur Radiol 17:581–588PubMedCrossRef
51.
Zurück zum Zitat Golub RM, Bennett CL, Stinson T, Venta L, Morrow M (2004) Cost minimization study of image-guided core biopsy versus surgical excisional biopsy for women with abnormal mammograms. J Clin Oncol 22:2430–2437PubMedCrossRef Golub RM, Bennett CL, Stinson T, Venta L, Morrow M (2004) Cost minimization study of image-guided core biopsy versus surgical excisional biopsy for women with abnormal mammograms. J Clin Oncol 22:2430–2437PubMedCrossRef
52.
Zurück zum Zitat Gruber R, Bernt R, Helbich TH (2008) [Cost-Effectiveness of Percutaneous Core Needle Breast Biopsy (CNBB) Versus Open Surgical Biopsy (OSB) of Nonpalpable Breast Lesions: Metaanalysis and Cost Evaluation for German-Speaking Countries.]. Rofo 180:134–142PubMed Gruber R, Bernt R, Helbich TH (2008) [Cost-Effectiveness of Percutaneous Core Needle Breast Biopsy (CNBB) Versus Open Surgical Biopsy (OSB) of Nonpalpable Breast Lesions: Metaanalysis and Cost Evaluation for German-Speaking Countries.]. Rofo 180:134–142PubMed
53.
Zurück zum Zitat Liberman L, Goodstine SL, Dershaw DD et al (2002) One operation after percutaneous diagnosis of nonpalpable breast cancer: frequency and associated factors. AJR Am J Roentgenol 178:673–679PubMed Liberman L, Goodstine SL, Dershaw DD et al (2002) One operation after percutaneous diagnosis of nonpalpable breast cancer: frequency and associated factors. AJR Am J Roentgenol 178:673–679PubMed
54.
Zurück zum Zitat Lannin DR, Ponn T, Andrejeva L, Philpotts L (2006) Should all breast cancers be diagnosed by needle biopsy? Am J Surg 192:450–454PubMedCrossRef Lannin DR, Ponn T, Andrejeva L, Philpotts L (2006) Should all breast cancers be diagnosed by needle biopsy? Am J Surg 192:450–454PubMedCrossRef
55.
Zurück zum Zitat Whitten TM, Wallace TW, Bird RE, Turk PS (1997) Image-guided core biopsy has advantages over needle localization biopsy for the diagnosis of nonpalpable breast cancer. Am Surg 63:1072–1077 discussion 1077-1078PubMed Whitten TM, Wallace TW, Bird RE, Turk PS (1997) Image-guided core biopsy has advantages over needle localization biopsy for the diagnosis of nonpalpable breast cancer. Am Surg 63:1072–1077 discussion 1077-1078PubMed
56.
Zurück zum Zitat Kopans DB (1994) Caution on core. Radiology 193:325–326, discussion 326-328PubMed Kopans DB (1994) Caution on core. Radiology 193:325–326, discussion 326-328PubMed
57.
Zurück zum Zitat Jackman RJ, Marzoni FA Jr. (1997) Needle-localized breast biopsy: why do we fail? Radiology 204:677–684PubMed Jackman RJ, Marzoni FA Jr. (1997) Needle-localized breast biopsy: why do we fail? Radiology 204:677–684PubMed
58.
Zurück zum Zitat Meyer JE, Smith DN, Lester SC et al (1998) Large-needle core biopsy: nonmalignant breast abnormalities evaluated with surgical excision or repeat core biopsy. Radiology 206:717–720PubMed Meyer JE, Smith DN, Lester SC et al (1998) Large-needle core biopsy: nonmalignant breast abnormalities evaluated with surgical excision or repeat core biopsy. Radiology 206:717–720PubMed
59.
Zurück zum Zitat Mueller-Holzner E, Frede T, Daniaux M et al (2007) Ultrasound-guided core needle biopsy of the breast: does frozen section give an accurate diagnosis? Breast Cancer Res Treat 106:399–406PubMedCrossRef Mueller-Holzner E, Frede T, Daniaux M et al (2007) Ultrasound-guided core needle biopsy of the breast: does frozen section give an accurate diagnosis? Breast Cancer Res Treat 106:399–406PubMedCrossRef
60.
Zurück zum Zitat Verkooijen HM, Peeters PH, Buskens E et al (2000) Diagnostic accuracy of large-core needle biopsy for nonpalpable breast disease: a meta-analysis. Br J Cancer 82:1017–1021PubMedCrossRef Verkooijen HM, Peeters PH, Buskens E et al (2000) Diagnostic accuracy of large-core needle biopsy for nonpalpable breast disease: a meta-analysis. Br J Cancer 82:1017–1021PubMedCrossRef
61.
Zurück zum Zitat Jackman RJ, Birdwell RL, Ikeda DM (2002) Atypical ductal hyperplasia: can some lesions be defined as probably benign after stereotactic 11-gauge vacuum-assisted biopsy, eliminating the recommendation for surgical excision? Radiology 224:548–554PubMedCrossRef Jackman RJ, Birdwell RL, Ikeda DM (2002) Atypical ductal hyperplasia: can some lesions be defined as probably benign after stereotactic 11-gauge vacuum-assisted biopsy, eliminating the recommendation for surgical excision? Radiology 224:548–554PubMedCrossRef
62.
Zurück zum Zitat Diaz LK, Wiley EL, Venta LA (1999) Are malignant cells displaced by large-gauge needle core biopsy of the breast? AJR Am J Roentgenol 173:1303–1313PubMed Diaz LK, Wiley EL, Venta LA (1999) Are malignant cells displaced by large-gauge needle core biopsy of the breast? AJR Am J Roentgenol 173:1303–1313PubMed
63.
Zurück zum Zitat Hoorntje LE, Schipper ME, Kaya A, Verkooijen HM, Klinkenbijl JG, Borel Rinkes IH (2004) Tumour cell displacement after 14G breast biopsy. Eur J Surg Oncol 30:520–525PubMedCrossRef Hoorntje LE, Schipper ME, Kaya A, Verkooijen HM, Klinkenbijl JG, Borel Rinkes IH (2004) Tumour cell displacement after 14G breast biopsy. Eur J Surg Oncol 30:520–525PubMedCrossRef
64.
Zurück zum Zitat Comstock CE (2005) US-guided interventional procedures. In: Feiss SA (ed) Categorial course in diagnostic radiology-breast imaging. RSNA, Oak Brook Comstock CE (2005) US-guided interventional procedures. In: Feiss SA (ed) Categorial course in diagnostic radiology-breast imaging. RSNA, Oak Brook
65.
Zurück zum Zitat Pisano ED, Fajardo LL, Caudry DJ et al (2001) Fine-needle aspiration biopsy of nonpalpable breast lesions in a multicenter clinical trial: results from the radiologic diagnostic oncology group V. Radiology 219:785–792PubMed Pisano ED, Fajardo LL, Caudry DJ et al (2001) Fine-needle aspiration biopsy of nonpalpable breast lesions in a multicenter clinical trial: results from the radiologic diagnostic oncology group V. Radiology 219:785–792PubMed
66.
Zurück zum Zitat Kanz KG, Linsenmaier U, Pfeifer KJ, Mutschler W (2002) [Standardized evaluation of trauma patients: requirements for diagnostic imaging]. Radiologe 42:515–521PubMedCrossRef Kanz KG, Linsenmaier U, Pfeifer KJ, Mutschler W (2002) [Standardized evaluation of trauma patients: requirements for diagnostic imaging]. Radiologe 42:515–521PubMedCrossRef
67.
Zurück zum Zitat Rosen EL, Bentley RC, Baker JA, Soo MS (2002) Imaging-guided core needle biopsy of papillary lesions of the breast. AJR Am J Roentgenol 179:1185–1192PubMed Rosen EL, Bentley RC, Baker JA, Soo MS (2002) Imaging-guided core needle biopsy of papillary lesions of the breast. AJR Am J Roentgenol 179:1185–1192PubMed
68.
Zurück zum Zitat Liberman L, Kaplan JB, Morris EA, Abramson AF, Menell JH, Dershaw DD (2002) To excise or to sample the mammographic target: what is the goal of stereotactic 11-gauge vacuum-assisted breast biopsy? AJR Am J Roentgenol 179:679–683PubMed Liberman L, Kaplan JB, Morris EA, Abramson AF, Menell JH, Dershaw DD (2002) To excise or to sample the mammographic target: what is the goal of stereotactic 11-gauge vacuum-assisted breast biopsy? AJR Am J Roentgenol 179:679–683PubMed
69.
Zurück zum Zitat Bonifacino A, Petrocelli V, Pisani T et al (2005) Accuracy rates of US-guided vacuum-assisted breast biopsy. Anticancer Res 25:2465–2470PubMed Bonifacino A, Petrocelli V, Pisani T et al (2005) Accuracy rates of US-guided vacuum-assisted breast biopsy. Anticancer Res 25:2465–2470PubMed
70.
Zurück zum Zitat Gruber R, Jaromi S, Floery D, Memarsadeghi M, Helbich TH (2006) Cost-effectiveness of US-guided 14-G core needle breast biopsy (CNBB) versus open surgical excision. In: Cost-effectiveness of US-guided 14-G core needle breast biopsy (CNBB) versus open surgical excision: Medical University of Vienna, Vienna Gruber R, Jaromi S, Floery D, Memarsadeghi M, Helbich TH (2006) Cost-effectiveness of US-guided 14-G core needle breast biopsy (CNBB) versus open surgical excision. In: Cost-effectiveness of US-guided 14-G core needle breast biopsy (CNBB) versus open surgical excision: Medical University of Vienna, Vienna
71.
Zurück zum Zitat Reiner C, Helbich TH, Floery D, Jaromi S, Riedl CC, Fuchsjager MH (2006) Galactography-guided stereotactic 11-gauge vacuum-assisted directional biopsy of intraductal lesions: no alternative to open surgery. Eur Radiol 316 Reiner C, Helbich TH, Floery D, Jaromi S, Riedl CC, Fuchsjager MH (2006) Galactography-guided stereotactic 11-gauge vacuum-assisted directional biopsy of intraductal lesions: no alternative to open surgery. Eur Radiol 316
72.
Zurück zum Zitat Weismann CF, Forstner R, Prokop E, Rettenbacher T (2000) Three-dimensional targeting: a new three-dimensional ultrasound technique to evaluate needle position during breast biopsy. Ultrasound Obstet Gynecol 16:359–364PubMedCrossRef Weismann CF, Forstner R, Prokop E, Rettenbacher T (2000) Three-dimensional targeting: a new three-dimensional ultrasound technique to evaluate needle position during breast biopsy. Ultrasound Obstet Gynecol 16:359–364PubMedCrossRef
73.
Zurück zum Zitat Surry KJ, Smith WL, Campbell LJ, Mills GR, Downey DB, Fenster A (2002) The development and evaluation of a three-dimensional ultrasound-guided breast biopsy apparatus. Med Image Anal 6:301–312PubMedCrossRef Surry KJ, Smith WL, Campbell LJ, Mills GR, Downey DB, Fenster A (2002) The development and evaluation of a three-dimensional ultrasound-guided breast biopsy apparatus. Med Image Anal 6:301–312PubMedCrossRef
74.
Zurück zum Zitat Lell M, Wenkel E, Aichinger U, Schulz-Wendtland R, Bautz W (2004) [3D ultrasound in core breast biopsy]. Ultraschall Med 25:126–130PubMedCrossRef Lell M, Wenkel E, Aichinger U, Schulz-Wendtland R, Bautz W (2004) [3D ultrasound in core breast biopsy]. Ultraschall Med 25:126–130PubMedCrossRef
75.
Zurück zum Zitat Delle Chiaie L, Terinde R (2004) Three-dimensional ultrasound-validated large-core needle biopsy: is it a reliable method for the histological assessment of breast lesions? Ultrasound Obstet Gynecol 23:393–397PubMedCrossRef Delle Chiaie L, Terinde R (2004) Three-dimensional ultrasound-validated large-core needle biopsy: is it a reliable method for the histological assessment of breast lesions? Ultrasound Obstet Gynecol 23:393–397PubMedCrossRef
76.
Zurück zum Zitat Wunderbaldinger P, Helbich TH, Partik B, Turetschek K, Wolf G (2001) First experience with a new dedicated ultrasound system for computer-guided large-core breast biopsy. Eur Radiol 11:2460–2464PubMedCrossRef Wunderbaldinger P, Helbich TH, Partik B, Turetschek K, Wolf G (2001) First experience with a new dedicated ultrasound system for computer-guided large-core breast biopsy. Eur Radiol 11:2460–2464PubMedCrossRef
77.
Zurück zum Zitat Stuhlfaut JW, Lucey BC, Varghese JC, Soto JA (2006) Blunt abdominal trauma: utility of 5-minute delayed CT with a reduced radiation dose. Radiology 238:473–479PubMedCrossRef Stuhlfaut JW, Lucey BC, Varghese JC, Soto JA (2006) Blunt abdominal trauma: utility of 5-minute delayed CT with a reduced radiation dose. Radiology 238:473–479PubMedCrossRef
78.
Zurück zum Zitat Jung EM, Jungius KP, Lenhart M, Dengler M, Becker H, Rupp N (2004) [Tissue harmonic imaging (THI) and contrast harmonic imaging (CHI) for sonographically guided vacuum-assisted biopsy of mammographically occult breast tumors]. Rofo 176:1416–1422PubMed Jung EM, Jungius KP, Lenhart M, Dengler M, Becker H, Rupp N (2004) [Tissue harmonic imaging (THI) and contrast harmonic imaging (CHI) for sonographically guided vacuum-assisted biopsy of mammographically occult breast tumors]. Rofo 176:1416–1422PubMed
79.
Zurück zum Zitat Sehgal CM, Weinstein SP, Arger PH, Conant EF (2006) A review of breast ultrasound. J Mammary Gland Biol Neoplasia 11:113–123PubMedCrossRef Sehgal CM, Weinstein SP, Arger PH, Conant EF (2006) A review of breast ultrasound. J Mammary Gland Biol Neoplasia 11:113–123PubMedCrossRef
80.
Zurück zum Zitat Mesurolle B, Bining HJ, El Khoury M, Barhdadi A, Kao E (2006) Contribution of tissue harmonic imaging and frequency compound imaging in interventional breast sonography. J Ultrasound Med 25:845–855PubMed Mesurolle B, Bining HJ, El Khoury M, Barhdadi A, Kao E (2006) Contribution of tissue harmonic imaging and frequency compound imaging in interventional breast sonography. J Ultrasound Med 25:845–855PubMed
81.
Zurück zum Zitat Huber S, Wagner M, Medl M, Czembirek H (2002) Real-time spatial compound imaging in breast ultrasound. Ultrasound Med Biol 28:155–163PubMedCrossRef Huber S, Wagner M, Medl M, Czembirek H (2002) Real-time spatial compound imaging in breast ultrasound. Ultrasound Med Biol 28:155–163PubMedCrossRef
82.
Zurück zum Zitat Desser TS, Jeffrey RB (2001) Tissue harmonic imaging techniques: physical principles and clinical applications. Semin Ultrasound CT MR 22:1–10PubMedCrossRef Desser TS, Jeffrey RB (2001) Tissue harmonic imaging techniques: physical principles and clinical applications. Semin Ultrasound CT MR 22:1–10PubMedCrossRef
83.
Zurück zum Zitat Cha JH, Moon WK, Cho N et al (2007) Characterization of benign and malignant solid breast masses: comparison of conventional US and tissue harmonic imaging. Radiology 242:63–69PubMedCrossRef Cha JH, Moon WK, Cho N et al (2007) Characterization of benign and malignant solid breast masses: comparison of conventional US and tissue harmonic imaging. Radiology 242:63–69PubMedCrossRef
84.
Zurück zum Zitat Saleh A, Ernst S, Grust A, Furst G, Dall P, Modder U (2001) [Real-time compound imaging: improved visibility of puncture needles and localization wires as compared to single-line ultrasonography]. Rofo 173:368–372PubMed Saleh A, Ernst S, Grust A, Furst G, Dall P, Modder U (2001) [Real-time compound imaging: improved visibility of puncture needles and localization wires as compared to single-line ultrasonography]. Rofo 173:368–372PubMed
85.
Zurück zum Zitat Ko K, Han BK, Jang KM et al (2007) The value of ultrasound-guided tattooing localization of nonpalpable breast lesions. Korean J Radiol 8:295–301PubMedCrossRef Ko K, Han BK, Jang KM et al (2007) The value of ultrasound-guided tattooing localization of nonpalpable breast lesions. Korean J Radiol 8:295–301PubMedCrossRef
86.
Zurück zum Zitat Viehweg P, Fabel K, Petzold A, Friedrich K, Laniado M (2007) [O-Twist Marker for marking breast cancer under neoadjuvant chemotherapy–first results]. Rofo 179:1055–1060PubMed Viehweg P, Fabel K, Petzold A, Friedrich K, Laniado M (2007) [O-Twist Marker for marking breast cancer under neoadjuvant chemotherapy–first results]. Rofo 179:1055–1060PubMed
87.
Zurück zum Zitat Fornage BD, Sneige N, Ross MI et al (2004) Small (< or = 2-cm) breast cancer treated with US-guided radiofrequency ablation: feasibility study. Radiology 231:215–224PubMedCrossRef Fornage BD, Sneige N, Ross MI et al (2004) Small (< or = 2-cm) breast cancer treated with US-guided radiofrequency ablation: feasibility study. Radiology 231:215–224PubMedCrossRef
88.
Zurück zum Zitat Kaufman CS, Bachman B, Littrup PJ et al (2004) Cryoablation treatment of benign breast lesions with 12-month follow-up. Am J Surg 188:340–348PubMedCrossRef Kaufman CS, Bachman B, Littrup PJ et al (2004) Cryoablation treatment of benign breast lesions with 12-month follow-up. Am J Surg 188:340–348PubMedCrossRef
89.
Zurück zum Zitat Kaufman CS, Littrup PJ, Freman-Gibb LA et al (2004) Office-based cryoablation of breast fibroadenomas: 12-month followup. J Am Coll Surg 198:914–923PubMedCrossRef Kaufman CS, Littrup PJ, Freman-Gibb LA et al (2004) Office-based cryoablation of breast fibroadenomas: 12-month followup. J Am Coll Surg 198:914–923PubMedCrossRef
90.
Zurück zum Zitat Khatri VP, McGahan JP, Ramsamooj R et al (2007) A phase II trial of image-guided radiofrequency ablation of small invasive breast carcinomas: use of saline-cooled tip electrode. Ann Surg Oncol 14:1644–1652PubMedCrossRef Khatri VP, McGahan JP, Ramsamooj R et al (2007) A phase II trial of image-guided radiofrequency ablation of small invasive breast carcinomas: use of saline-cooled tip electrode. Ann Surg Oncol 14:1644–1652PubMedCrossRef
91.
Zurück zum Zitat Littrup PJ, Freeman-Gibb L, Andea A et al (2005) Cryotherapy for breast fibroadenomas. Radiology 234:63–72PubMedCrossRef Littrup PJ, Freeman-Gibb L, Andea A et al (2005) Cryotherapy for breast fibroadenomas. Radiology 234:63–72PubMedCrossRef
92.
Zurück zum Zitat Marcy PY, Magne N, Castadot P, Bailet C, Namer M (2007) Ultrasound-guided percutaneous radiofrequency ablation in elderly breast cancer patients: preliminary institutional experience. Br J Radiol 80:267–273PubMedCrossRef Marcy PY, Magne N, Castadot P, Bailet C, Namer M (2007) Ultrasound-guided percutaneous radiofrequency ablation in elderly breast cancer patients: preliminary institutional experience. Br J Radiol 80:267–273PubMedCrossRef
93.
Zurück zum Zitat Pfleiderer SO, Freesmeyer MG, Marx C, Kuhne-Heid R, Schneider A, Kaiser WA (2002) Cryotherapy of breast cancer under ultrasound guidance: initial results and limitations. Eur Radiol 12:3009–3014PubMed Pfleiderer SO, Freesmeyer MG, Marx C, Kuhne-Heid R, Schneider A, Kaiser WA (2002) Cryotherapy of breast cancer under ultrasound guidance: initial results and limitations. Eur Radiol 12:3009–3014PubMed
94.
Zurück zum Zitat Pfleiderer SO, Marx C, Camara O, Gajda M, Kaiser WA (2005) Ultrasound-guided, percutaneous cryotherapy of small (< or = 15 mm) breast cancers. Invest Radiol 40:472–477PubMedCrossRef Pfleiderer SO, Marx C, Camara O, Gajda M, Kaiser WA (2005) Ultrasound-guided, percutaneous cryotherapy of small (< or = 15 mm) breast cancers. Invest Radiol 40:472–477PubMedCrossRef
95.
Zurück zum Zitat Roubidoux MA, Sabel MS, Bailey JE, Kleer CG, Klein KA, Helvie MA (2004) Small (< 2.0-cm) breast cancers: mammographic and US findings at US-guided cryoablation—initial experience. Radiology 233:857–867PubMedCrossRef Roubidoux MA, Sabel MS, Bailey JE, Kleer CG, Klein KA, Helvie MA (2004) Small (< 2.0-cm) breast cancers: mammographic and US findings at US-guided cryoablation—initial experience. Radiology 233:857–867PubMedCrossRef
96.
Zurück zum Zitat Susini T, Nori J, Olivieri S et al (2007) Radiofrequency ablation for minimally invasive treatment of breast carcinoma. A pilot study in elderly inoperable patients. Gynecol Oncol 104:304–310PubMedCrossRef Susini T, Nori J, Olivieri S et al (2007) Radiofrequency ablation for minimally invasive treatment of breast carcinoma. A pilot study in elderly inoperable patients. Gynecol Oncol 104:304–310PubMedCrossRef
97.
Zurück zum Zitat Boehm T, Malich A, Nahum Goldberg S et al (2001) Vacuum-assisted resection of malignant tumors with and without subsequent radiofrequency ablation: feasibility of complete tumor treatment tested in an animal model. J Vasc Interv Radiol 12:1086–1093PubMedCrossRef Boehm T, Malich A, Nahum Goldberg S et al (2001) Vacuum-assisted resection of malignant tumors with and without subsequent radiofrequency ablation: feasibility of complete tumor treatment tested in an animal model. J Vasc Interv Radiol 12:1086–1093PubMedCrossRef
Metadaten
Titel
Accuracy of ultrasound-guided, large-core needle breast biopsy
verfasst von
G. Schueller
C. Schueller-Weidekamm
T. H. Helbich
Publikationsdatum
01.09.2008
Verlag
Springer-Verlag
Erschienen in
European Radiology / Ausgabe 9/2008
Print ISSN: 0938-7994
Elektronische ISSN: 1432-1084
DOI
https://doi.org/10.1007/s00330-008-0955-4

Weitere Artikel der Ausgabe 9/2008

European Radiology 9/2008 Zur Ausgabe

Update Radiologie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.