Skip to main content
Erschienen in: European Radiology 12/2008

01.12.2008 | Contrast Media

Which Iodine concentration in chest CT? – A prospective study in 300 patients

verfasst von: Georg Mühlenbruch, Florian F. Behrendt, Mohammed A. Eddahabi, Christian Knackstedt, Sven Stanzel, Marco Das, Peter Seidensticker, Rolf W. Günther, Joachim E. Wildberger, Andreas H. Mahnken

Erschienen in: European Radiology | Ausgabe 12/2008

Einloggen, um Zugang zu erhalten

Abstract

In computed tomography(CT) several contrast media with different iodine concentrations are available. The aim of this study is to prospectively compare contrast media with iodine concentrations of 300, 370 and 400 mg iodine/ml for chest- CT. 300 consecutive patients were prospectively enrolled, under a waiver of the local ethics committee. The first (second, third) 100 patients, received contrast medium with 300(370, 400)mg iodine/ml. Injection protocols were adapted for an identical iodine delivery rate(1.3 mg/s) and total iodine load(33 g) for all three groups. Standardized MDCT of the chest (16 × 0.75 mm, 120 kVp, 100 mAseff.) was performed. Intravascular attenuation values were measured in the pulmonary trunk and the ascending aorta; subjective image quality was rated on a 3-point-scale. Discomfort during and after injection was evaluated. There were no statistically significant differences in contrast enhancement comparing the three contrast media at the pulmonary trunk(p = 0.3198) and at the ascending aorta(p = 0.0840). Image quality(p = 0.0176) and discomfort during injection(p = 0.7034) were comparable for all groups. General discomfort after injection of contrast media with 300 mg iodine/ml was statistically significant higher compared to 370 mg iodine/ml(p = 0.00019). Given identical iodine delivery rates of 1.3 g/s and iodine loads of 33 g, contrast media with concentrations of 300, 370 and 400 mg iodine/ml do not result in different intravascular enhancement in chest-CT.
Literatur
1.
Zurück zum Zitat Awai K, Hiraishi K, Hori S (2004) Effect of contrast material injection duration and rate on aortic peak time and peak enhancement at dynamic CT involving injection protocol with dose tailored to patient weight. Radiology 230:142–150PubMedCrossRef Awai K, Hiraishi K, Hori S (2004) Effect of contrast material injection duration and rate on aortic peak time and peak enhancement at dynamic CT involving injection protocol with dose tailored to patient weight. Radiology 230:142–150PubMedCrossRef
2.
Zurück zum Zitat Heiken JP, Brink JA, McClennan BL, Sagel SS, Forman HP, DiCroce J (1993) Dynamic contrast-enhanced CT of the liver: comparison of contrast medium injection rates and uniphasic and biphasic injection protocols. Radiology 187:327–331PubMed Heiken JP, Brink JA, McClennan BL, Sagel SS, Forman HP, DiCroce J (1993) Dynamic contrast-enhanced CT of the liver: comparison of contrast medium injection rates and uniphasic and biphasic injection protocols. Radiology 187:327–331PubMed
3.
Zurück zum Zitat Heiken JP, Brink JA, McClennan BL, Sagel SS, Crowe TM, Gaines MV (1995) Dynamic incremental CT: effect of volume and concentration of contrast material and patient weight on hepatic enhancement. Radiology 195:353–357PubMed Heiken JP, Brink JA, McClennan BL, Sagel SS, Crowe TM, Gaines MV (1995) Dynamic incremental CT: effect of volume and concentration of contrast material and patient weight on hepatic enhancement. Radiology 195:353–357PubMed
4.
Zurück zum Zitat Haage P, Schmitz-Rode T, Hubner D, Piroth W, Gunther RW (2000) Reduction of contrast material dose and artifacts by a saline flush using a double power injector in helical CT of the thorax. AJR Am J Roentgenol 174:1049–1053PubMed Haage P, Schmitz-Rode T, Hubner D, Piroth W, Gunther RW (2000) Reduction of contrast material dose and artifacts by a saline flush using a double power injector in helical CT of the thorax. AJR Am J Roentgenol 174:1049–1053PubMed
5.
Zurück zum Zitat Bae KT, Heiken JP, Brink JA (2000) Aortic and hepatic contrast medium enhancement at CT. Part II. Effect of reduced cardiac output in a porcine model. Radiology 207:657–662 Bae KT, Heiken JP, Brink JA (2000) Aortic and hepatic contrast medium enhancement at CT. Part II. Effect of reduced cardiac output in a porcine model. Radiology 207:657–662
6.
Zurück zum Zitat Bae KT, Heiken JP, Brink JA (1998) Aortic and hepatic contrast medium enhancement at CT. Part I. Prediction with a computer model. Radiology 207:647–655PubMed Bae KT, Heiken JP, Brink JA (1998) Aortic and hepatic contrast medium enhancement at CT. Part I. Prediction with a computer model. Radiology 207:647–655PubMed
7.
Zurück zum Zitat Bae KT, Heiken JP, Brink JA (1998) Aortic and hepatic peak enhancement at CT: effect of contrast medium injection rate–pharmacokinetic analysis and experimental porcine model. Radiology 206:455–464PubMed Bae KT, Heiken JP, Brink JA (1998) Aortic and hepatic peak enhancement at CT: effect of contrast medium injection rate–pharmacokinetic analysis and experimental porcine model. Radiology 206:455–464PubMed
8.
Zurück zum Zitat Brink JA, Heiken JP, Forman HP, Sagel SS, Molina PL, Brown PC (1995) Hepatic spiral CT: reduction of dose of intravenous contrast material. Radiology 197:83–88PubMed Brink JA, Heiken JP, Forman HP, Sagel SS, Molina PL, Brown PC (1995) Hepatic spiral CT: reduction of dose of intravenous contrast material. Radiology 197:83–88PubMed
9.
Zurück zum Zitat Brink JA (2003) Use of high concentration contrast media (HCCM): principles and rationale–body CT. Eur J Radiol 45(Suppl 1):S53–S58PubMedCrossRef Brink JA (2003) Use of high concentration contrast media (HCCM): principles and rationale–body CT. Eur J Radiol 45(Suppl 1):S53–S58PubMedCrossRef
10.
Zurück zum Zitat Han JK, Kim AY, Lee KY et al (2000) Factors influencing vascular and hepatic enhancement at CT: experimental study on injection protocol using a canine model. J Comput Assist Tomogr 24:400–406PubMedCrossRef Han JK, Kim AY, Lee KY et al (2000) Factors influencing vascular and hepatic enhancement at CT: experimental study on injection protocol using a canine model. J Comput Assist Tomogr 24:400–406PubMedCrossRef
11.
Zurück zum Zitat Fleischmann D (2003) Use of high-concentration contrast media in multiple-detector-row CT: principles and rationale. Eur Radiol 13(Suppl 5):M14–M20PubMed Fleischmann D (2003) Use of high-concentration contrast media in multiple-detector-row CT: principles and rationale. Eur Radiol 13(Suppl 5):M14–M20PubMed
12.
Zurück zum Zitat Fleischmann D (2003) High-concentration contrast media in MDCT angiography: principles and rationale. Eur Radiol 13(Suppl 3):N39–N43PubMedCrossRef Fleischmann D (2003) High-concentration contrast media in MDCT angiography: principles and rationale. Eur Radiol 13(Suppl 3):N39–N43PubMedCrossRef
13.
Zurück zum Zitat Fleischmann D (2003) Use of high concentration contrast media: principles and rationale-vascular district. Eur Radiol 45(Suppl 1):S88–S93 Fleischmann D (2003) Use of high concentration contrast media: principles and rationale-vascular district. Eur Radiol 45(Suppl 1):S88–S93
14.
Zurück zum Zitat Awai K, Inoue M, Yagyu Y et al (2004) Moderate versus high concentration of contrast material for aortic and hepatic enhancement and tumor-to-liver contrast at multi-detector row CT. Radiology 233:682–688PubMedCrossRef Awai K, Inoue M, Yagyu Y et al (2004) Moderate versus high concentration of contrast material for aortic and hepatic enhancement and tumor-to-liver contrast at multi-detector row CT. Radiology 233:682–688PubMedCrossRef
15.
Zurück zum Zitat Awai K, Takada K, Onishi H, Hori S (2002) Aortic and hepatic enhancement and tumor-to-liver contrast: analysis of the effect of different concentrations of contrast material at multi-detector row helical CT. Radiology 224:757–763PubMedCrossRef Awai K, Takada K, Onishi H, Hori S (2002) Aortic and hepatic enhancement and tumor-to-liver contrast: analysis of the effect of different concentrations of contrast material at multi-detector row helical CT. Radiology 224:757–763PubMedCrossRef
16.
Zurück zum Zitat Cademartiri F, de Monye C, Pugliese F et al (2006) High iodine concentration contrast material for noninvasive multislice computed tomography coronary angiography: iopromide 370 versus iomeprol 400. Invest Radiol 41:349–353PubMedCrossRef Cademartiri F, de Monye C, Pugliese F et al (2006) High iodine concentration contrast material for noninvasive multislice computed tomography coronary angiography: iopromide 370 versus iomeprol 400. Invest Radiol 41:349–353PubMedCrossRef
17.
Zurück zum Zitat Furuta A, Ito K, Fujita T, Koike S, Shimizu A, Matsunaga N (2004) Hepatic enhancement in multiphasic contrast-enhanced MDCT: comparison of high- and low-iodine-concentration contrast medium in same patients with chronic liver disease. AJR Am J Roentgenol 183:157–162PubMed Furuta A, Ito K, Fujita T, Koike S, Shimizu A, Matsunaga N (2004) Hepatic enhancement in multiphasic contrast-enhanced MDCT: comparison of high- and low-iodine-concentration contrast medium in same patients with chronic liver disease. AJR Am J Roentgenol 183:157–162PubMed
18.
Zurück zum Zitat Sandstede JJ, Werner A, Kaupert C et al (2006) A prospective study comparing different iodine concentrations for triphasic multidetector row CT of the upper abdomen. Eur J Radiol 60:95–99PubMedCrossRef Sandstede JJ, Werner A, Kaupert C et al (2006) A prospective study comparing different iodine concentrations for triphasic multidetector row CT of the upper abdomen. Eur J Radiol 60:95–99PubMedCrossRef
19.
Zurück zum Zitat Setty BN, Sahani DV, Ouellette-Piazzo K, Hahn PF, Shepard JA (2006) Comparison of enhancement, image quality, cost, and adverse reactions using 2 different contrast medium concentrations for routine chest CT on 16-slice MDCT. J Comput Assist Tomogr 30:818–822PubMedCrossRef Setty BN, Sahani DV, Ouellette-Piazzo K, Hahn PF, Shepard JA (2006) Comparison of enhancement, image quality, cost, and adverse reactions using 2 different contrast medium concentrations for routine chest CT on 16-slice MDCT. J Comput Assist Tomogr 30:818–822PubMedCrossRef
20.
Zurück zum Zitat Rist C, Nikolaou K, Kirchin MA et al (2006) Contrast bolus optimization for cardiac 16-slice computed tomography: comparison of contrast medium formulations containing 300 and 400 milligrams of iodine per milliliter. Invest Radiol 41:460–467PubMedCrossRef Rist C, Nikolaou K, Kirchin MA et al (2006) Contrast bolus optimization for cardiac 16-slice computed tomography: comparison of contrast medium formulations containing 300 and 400 milligrams of iodine per milliliter. Invest Radiol 41:460–467PubMedCrossRef
21.
Zurück zum Zitat Sultana S, Morishita S, Awai K et al (2003) Evaluation of hypervascular hepatocellular carcinoma in cirrhotic liver by means of helical CT: comparison of different contrast medium concentrations within the same patient. Radiat Med 21:239–245PubMed Sultana S, Morishita S, Awai K et al (2003) Evaluation of hypervascular hepatocellular carcinoma in cirrhotic liver by means of helical CT: comparison of different contrast medium concentrations within the same patient. Radiat Med 21:239–245PubMed
22.
Zurück zum Zitat Tsurusaki M, Sugimoto K, Fujii M, Sugimura K (2004) Multi-detector row helical CT of the liver: quantitative assessment of iodine concentration of intravenous contrast material on multiphasic CT–a prospective randomized study. Radiat Med 22:239–245PubMed Tsurusaki M, Sugimoto K, Fujii M, Sugimura K (2004) Multi-detector row helical CT of the liver: quantitative assessment of iodine concentration of intravenous contrast material on multiphasic CT–a prospective randomized study. Radiat Med 22:239–245PubMed
23.
Zurück zum Zitat Tsai IC, Lee T, Tsai WL et al (2008) Contrast enhancement in cardiac MDCT: comparison of iodixanol 320 versus iohexol 350. AJR Am J Roentgenol 190:W47–W53PubMedCrossRef Tsai IC, Lee T, Tsai WL et al (2008) Contrast enhancement in cardiac MDCT: comparison of iodixanol 320 versus iohexol 350. AJR Am J Roentgenol 190:W47–W53PubMedCrossRef
24.
Zurück zum Zitat Valentine A, Jakobsen JA, Klaveness AJ (1997) Iopentol (Imagopaque 350) compared with diatrizoate (Urografin 370) in cerebral CT. A clinical trial assessing immediate and late (7 days) adverse events and diagnostic information (visualization quality and Hounsfield unit measurements). Eur Radiol 7(Suppl 4):S145–S148PubMedCrossRef Valentine A, Jakobsen JA, Klaveness AJ (1997) Iopentol (Imagopaque 350) compared with diatrizoate (Urografin 370) in cerebral CT. A clinical trial assessing immediate and late (7 days) adverse events and diagnostic information (visualization quality and Hounsfield unit measurements). Eur Radiol 7(Suppl 4):S145–S148PubMedCrossRef
25.
Zurück zum Zitat Tytle T, Prati RC Jr., Azodo MV, Gutierrez O (1996) A prospective, parallel, double-blind comparison of iodixanol and iohexol in extremity phlebography. Acad Radiol 3(Suppl 3):S519–S523PubMedCrossRef Tytle T, Prati RC Jr., Azodo MV, Gutierrez O (1996) A prospective, parallel, double-blind comparison of iodixanol and iohexol in extremity phlebography. Acad Radiol 3(Suppl 3):S519–S523PubMedCrossRef
26.
Zurück zum Zitat Sundgren PC, Baath L, Tornquist C, Hougens Grynne B, Kjaersgaard P, Almen T (1996) Image quality and safety after iodixanol in intravenous urography; a comparison with iohexol. Br J Radiol 69:699–703PubMedCrossRef Sundgren PC, Baath L, Tornquist C, Hougens Grynne B, Kjaersgaard P, Almen T (1996) Image quality and safety after iodixanol in intravenous urography; a comparison with iohexol. Br J Radiol 69:699–703PubMedCrossRef
27.
Zurück zum Zitat Tveit K, Bolz KD, Bolstad B et al (1994) Iodixanol in cardioangiography. A double-blind parallel comparison between iodixanol 320 mg I/ml and ioxaglate 320 mg I/ml. Acta Radiol 35:614–618PubMed Tveit K, Bolz KD, Bolstad B et al (1994) Iodixanol in cardioangiography. A double-blind parallel comparison between iodixanol 320 mg I/ml and ioxaglate 320 mg I/ml. Acta Radiol 35:614–618PubMed
Metadaten
Titel
Which Iodine concentration in chest CT? – A prospective study in 300 patients
verfasst von
Georg Mühlenbruch
Florian F. Behrendt
Mohammed A. Eddahabi
Christian Knackstedt
Sven Stanzel
Marco Das
Peter Seidensticker
Rolf W. Günther
Joachim E. Wildberger
Andreas H. Mahnken
Publikationsdatum
01.12.2008
Verlag
Springer-Verlag
Erschienen in
European Radiology / Ausgabe 12/2008
Print ISSN: 0938-7994
Elektronische ISSN: 1432-1084
DOI
https://doi.org/10.1007/s00330-008-1080-0

Weitere Artikel der Ausgabe 12/2008

European Radiology 12/2008 Zur Ausgabe

Update Radiologie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.