Skip to main content
Erschienen in: European Radiology 12/2008

01.12.2008 | Musculoskeletal

Shoulder arthroplasty

verfasst von: Florian M. Buck, Bernhard Jost, Juerg Hodler

Erschienen in: European Radiology | Ausgabe 12/2008

Einloggen, um Zugang zu erhalten

Abstract

Shoulder prostheses are now commonly used. Clinical results and patient satisfaction are usually good. The most commonly used types are humeral hemiarthroplasty, unconstrained total shoulder arthroplasty, and semiconstrained inversed shoulder prosthesis. Complications of shoulder arthroplasty depend on the prosthesis type used. The most common complications are prosthetic loosening, glenohumeral instability, periprosthetic fracture, rotator cuff tears, nerve injury, infection, and deltoid muscle dysfunction. Standard radiographs are the basis of both pre- and postoperative imaging. Skeletal scintigraphy has a rather limited role because there is overlap between postoperative changes which may persist for up to 1 year and early loosening and infection. Sonography is most commonly used postoperatively in order to demonstrate complications (hematoma and abscess formation) but may also be useful for the demonstration of rotator cuff tears occurring during follow-up. CT is useful for the demonstration of bone details both pre- and postoperatively. MR imaging is mainly used preoperatively, for instance for demonstration of rotator cuff tears.
Literatur
1.
Zurück zum Zitat Lugli T (1978) Artificial shoulder joint by Pean (1893): the facts of an exceptional intervention and the prosthetic method. Clin Orthop Relat Res 133:215–218PubMed Lugli T (1978) Artificial shoulder joint by Pean (1893): the facts of an exceptional intervention and the prosthetic method. Clin Orthop Relat Res 133:215–218PubMed
2.
Zurück zum Zitat Péan JE (1894) Des moyens prosthetiques destinés à obtenir la reparation des parties osseuses. Gaz des Hôp 67:291 Reprinted in English (1973) Clin Orthop 94:4 Péan JE (1894) Des moyens prosthetiques destinés à obtenir la reparation des parties osseuses. Gaz des Hôp 67:291 Reprinted in English (1973) Clin Orthop 94:4
3.
Zurück zum Zitat Wright TW, Cofield RH (1995) Humeral fractures after shoulder arthroplasty. J Bone Jt Surg Am 77:1340–1346 Wright TW, Cofield RH (1995) Humeral fractures after shoulder arthroplasty. J Bone Jt Surg Am 77:1340–1346
4.
Zurück zum Zitat Palestro CJ, Love C, Miller TT (2006) Infection and musculoskeletal conditions: imaging of musculoskeletal infections. Best Pract Res Clin Rheumatol 20:1197–1218PubMedCrossRef Palestro CJ, Love C, Miller TT (2006) Infection and musculoskeletal conditions: imaging of musculoskeletal infections. Best Pract Res Clin Rheumatol 20:1197–1218PubMedCrossRef
5.
Zurück zum Zitat Love C, Tomas MB, Marwin SE, Pugliese PV, Palestro CJ (2001) Role of nuclear medicine in diagnosis of the infected joint replacement. Radiographics 21:1229–1238PubMed Love C, Tomas MB, Marwin SE, Pugliese PV, Palestro CJ (2001) Role of nuclear medicine in diagnosis of the infected joint replacement. Radiographics 21:1229–1238PubMed
6.
Zurück zum Zitat Pakos EE, Koumoulis HD, Fotopoulos AD, Ioannidis JP (2007) Osteomyelitis: antigranulocyte scintigraphy with 99mTC radiolabeled monoclonal antibodies for diagnosis - meta-analysis. Radiology 245(3):732–741PubMedCrossRef Pakos EE, Koumoulis HD, Fotopoulos AD, Ioannidis JP (2007) Osteomyelitis: antigranulocyte scintigraphy with 99mTC radiolabeled monoclonal antibodies for diagnosis - meta-analysis. Radiology 245(3):732–741PubMedCrossRef
7.
Zurück zum Zitat Friedman RJ, Hawthorne KB, Genez BM (1992) The use of computerized tomography in the measurement of glenoid version. J Bone Jt Surg Am 74:1032–1037 Friedman RJ, Hawthorne KB, Genez BM (1992) The use of computerized tomography in the measurement of glenoid version. J Bone Jt Surg Am 74:1032–1037
8.
Zurück zum Zitat Nyffeler RW, Jost B, Pfirrmann CW, Gerber C (2003) Measurement of glenoid version: conventional radiographs versus computed tomography scans. J Shoulder Elb Surg 12:493–496CrossRef Nyffeler RW, Jost B, Pfirrmann CW, Gerber C (2003) Measurement of glenoid version: conventional radiographs versus computed tomography scans. J Shoulder Elb Surg 12:493–496CrossRef
9.
Zurück zum Zitat Hernigou P, Duparc F, Hernigou A (2002) Determining humeral retroversion with computed tomography. J Bone Jt Surg Am 84-A:1753–1762 Hernigou P, Duparc F, Hernigou A (2002) Determining humeral retroversion with computed tomography. J Bone Jt Surg Am 84-A:1753–1762
10.
Zurück zum Zitat Goutallier D, Postel JM, Bernageau J, Lavau L, Voisin MC (1994) Fatty muscle degeneration in cuff ruptures. Pre- and postoperative evaluation by CT scan. Clin Orthop Relat Res 304:78–83PubMed Goutallier D, Postel JM, Bernageau J, Lavau L, Voisin MC (1994) Fatty muscle degeneration in cuff ruptures. Pre- and postoperative evaluation by CT scan. Clin Orthop Relat Res 304:78–83PubMed
11.
Zurück zum Zitat Ohashi K, El-Khoury GY, Bennett DL, Restrepo JM, Berbaum KS (2005) Orthopedic hardware complications diagnosed with multi-detector row CT. Radiology 237:570–577PubMedCrossRef Ohashi K, El-Khoury GY, Bennett DL, Restrepo JM, Berbaum KS (2005) Orthopedic hardware complications diagnosed with multi-detector row CT. Radiology 237:570–577PubMedCrossRef
12.
Zurück zum Zitat Haramati N, Staron RB, Mazel-Sperling K et al (1994) CT scans through metal scanning technique versus hardware composition. Comput Med Imaging Graph 18:429–434PubMedCrossRef Haramati N, Staron RB, Mazel-Sperling K et al (1994) CT scans through metal scanning technique versus hardware composition. Comput Med Imaging Graph 18:429–434PubMedCrossRef
13.
Zurück zum Zitat White LM, Buckwalter KA (2002) Technical considerations: CT and MR Imaging in the postoperative orthopedic patient. Sem Musculoskelet Radiol 6:5–17CrossRef White LM, Buckwalter KA (2002) Technical considerations: CT and MR Imaging in the postoperative orthopedic patient. Sem Musculoskelet Radiol 6:5–17CrossRef
14.
Zurück zum Zitat Vande Berg B, Malghem J, Maldague B, Lecouvet F (2006) Multi-detector CT imaging in the postoperative orthopedic patient with metal hardware. Eur J Radiol 60:470–479PubMedCrossRef Vande Berg B, Malghem J, Maldague B, Lecouvet F (2006) Multi-detector CT imaging in the postoperative orthopedic patient with metal hardware. Eur J Radiol 60:470–479PubMedCrossRef
15.
Zurück zum Zitat Barrett JF, Keat N (2004) Artifacts in CT: recognition and avoidance. Radiographics 24:1679–1691PubMedCrossRef Barrett JF, Keat N (2004) Artifacts in CT: recognition and avoidance. Radiographics 24:1679–1691PubMedCrossRef
16.
Zurück zum Zitat Wilting JE, Timmer J (1999) Artefacts in spiral-CT images and their relation to pitch and subject morphology. Eur Radiol 9:316–322PubMedCrossRef Wilting JE, Timmer J (1999) Artefacts in spiral-CT images and their relation to pitch and subject morphology. Eur Radiol 9:316–322PubMedCrossRef
17.
Zurück zum Zitat Zanetti M, Hodler J (2004) MR imaging of the shoulder after surgery. Magn Reson Imaging Clin N Am 12:169–183PubMedCrossRef Zanetti M, Hodler J (2004) MR imaging of the shoulder after surgery. Magn Reson Imaging Clin N Am 12:169–183PubMedCrossRef
18.
Zurück zum Zitat Owen RS, Iannotti JP, Kneeland JB, Dalinka MK, Deren JA, Oleaga L (1993) Shoulder after surgery: MR imaging with surgical validation. Radiology 186:443–447PubMed Owen RS, Iannotti JP, Kneeland JB, Dalinka MK, Deren JA, Oleaga L (1993) Shoulder after surgery: MR imaging with surgical validation. Radiology 186:443–447PubMed
19.
Zurück zum Zitat Gaenslen ES, Satterlee CC, Hinson GW (1996) Magnetic resonance imaging for evaluation of failed repairs of the rotator cuff. J Bone Jt Surg Am 78:1391–1396 Gaenslen ES, Satterlee CC, Hinson GW (1996) Magnetic resonance imaging for evaluation of failed repairs of the rotator cuff. J Bone Jt Surg Am 78:1391–1396
20.
Zurück zum Zitat Suh JS, Jeong EK, Shin KH et al (1998) Minimizing artifacts caused by metallic implants at MR imaging: experimental and clinical studies. AJR Am J Roentgenol 171:1207–1213PubMed Suh JS, Jeong EK, Shin KH et al (1998) Minimizing artifacts caused by metallic implants at MR imaging: experimental and clinical studies. AJR Am J Roentgenol 171:1207–1213PubMed
21.
Zurück zum Zitat Port JD, Pomper MG (2000) Quantification and minimization of magnetic susceptibility artifacts on GRE images. J Comput Assist Tomogr 24:958–964PubMedCrossRef Port JD, Pomper MG (2000) Quantification and minimization of magnetic susceptibility artifacts on GRE images. J Comput Assist Tomogr 24:958–964PubMedCrossRef
22.
Zurück zum Zitat Hilfiker P, Zanetti M, Debatin JF, McKinnon G, Hodler J (1995) Fast spin-echo inversion-recovery imaging versus fast T2-weighted spin-echo imaging in bone marrow abnormalities. Invest Radiol 30:110–114PubMedCrossRef Hilfiker P, Zanetti M, Debatin JF, McKinnon G, Hodler J (1995) Fast spin-echo inversion-recovery imaging versus fast T2-weighted spin-echo imaging in bone marrow abnormalities. Invest Radiol 30:110–114PubMedCrossRef
23.
Zurück zum Zitat Hauger O, Dumont E, Chateil JF, Moinard M, Diard F (2002) Water excitation as an alternative to fat saturation in MR imaging: preliminary results in musculoskeletal imaging. Radiology 224:657–663PubMedCrossRef Hauger O, Dumont E, Chateil JF, Moinard M, Diard F (2002) Water excitation as an alternative to fat saturation in MR imaging: preliminary results in musculoskeletal imaging. Radiology 224:657–663PubMedCrossRef
24.
Zurück zum Zitat Merkle EM, Dale BM, Thomas J, Paulson EK (2006) MR liver imaging and cholangiography in the presence of surgical metallic clips at 1.5 and 3 Tesla. Eur Radiol 16:2309–2316PubMedCrossRef Merkle EM, Dale BM, Thomas J, Paulson EK (2006) MR liver imaging and cholangiography in the presence of surgical metallic clips at 1.5 and 3 Tesla. Eur Radiol 16:2309–2316PubMedCrossRef
25.
Zurück zum Zitat Pauchard Y, Smith MR, Mintchev MP (2005) Improving geometric accuracy in the presence of susceptibility difference artifacts produced by metallic implants in magnetic resonance imaging. IEEE Trans Med Imaging 24:1387–1399PubMedCrossRef Pauchard Y, Smith MR, Mintchev MP (2005) Improving geometric accuracy in the presence of susceptibility difference artifacts produced by metallic implants in magnetic resonance imaging. IEEE Trans Med Imaging 24:1387–1399PubMedCrossRef
26.
Zurück zum Zitat White CB, Sperling JW, Cofield RH, Rowland CM (2003) Ninety-day mortality after shoulder arthroplasty. J Arthroplasty 18:886–888PubMedCrossRef White CB, Sperling JW, Cofield RH, Rowland CM (2003) Ninety-day mortality after shoulder arthroplasty. J Arthroplasty 18:886–888PubMedCrossRef
27.
Zurück zum Zitat Bohsali KI, Wirth MA, Rockwood CA Jr (2006) Complications of total shoulder arthroplasty. J Bone Jt Surg Am 88:2279–2292CrossRef Bohsali KI, Wirth MA, Rockwood CA Jr (2006) Complications of total shoulder arthroplasty. J Bone Jt Surg Am 88:2279–2292CrossRef
28.
Zurück zum Zitat Hasan SS, Leith JM, Smith KL, Matsen FA (2003) The distribution of shoulder replacement among surgeons and hospitals is significantly different than that of hip or knee replacement. J Shoulder Elb Surg 12:164–169CrossRef Hasan SS, Leith JM, Smith KL, Matsen FA (2003) The distribution of shoulder replacement among surgeons and hospitals is significantly different than that of hip or knee replacement. J Shoulder Elb Surg 12:164–169CrossRef
29.
Zurück zum Zitat Hammond JW, Queale WS, Kim TK, McFarland EG (2003) Surgeon experience and clinical and economic outcomes for shoulder arthroplasty. J Bone Jt Surg Am 85-A:2318–2324 Hammond JW, Queale WS, Kim TK, McFarland EG (2003) Surgeon experience and clinical and economic outcomes for shoulder arthroplasty. J Bone Jt Surg Am 85-A:2318–2324
30.
Zurück zum Zitat Deshmukh AV, Koris M, Zurakowski D, Thornhill TS (2005) Total shoulder arthroplasty: long-term survivorship, functional outcome, and quality of life. J Shoulder Elb Surg 14:471–479CrossRef Deshmukh AV, Koris M, Zurakowski D, Thornhill TS (2005) Total shoulder arthroplasty: long-term survivorship, functional outcome, and quality of life. J Shoulder Elb Surg 14:471–479CrossRef
31.
Zurück zum Zitat Wirth MA, Rockwood CA Jr (1996) Complications of total shoulder-replacement arthroplasty. J Bone Joint Surg Am 78:603–616PubMed Wirth MA, Rockwood CA Jr (1996) Complications of total shoulder-replacement arthroplasty. J Bone Joint Surg Am 78:603–616PubMed
32.
Zurück zum Zitat Gruen TA, McNeice GM, Amstutz HC (1979) “Modes of failure” of cemented stem-type femoral components: a radiographic analysis of loosening. Clin Orthop Relat Res 141:17–27PubMed Gruen TA, McNeice GM, Amstutz HC (1979) “Modes of failure” of cemented stem-type femoral components: a radiographic analysis of loosening. Clin Orthop Relat Res 141:17–27PubMed
33.
Zurück zum Zitat Martin SD, Zurakowski D, Thornhill TS (2005) Uncemented glenoid component in total shoulder arthroplasty. Survivorship and outcomes. J Bone Jt Surg Am 87:1284–1292CrossRef Martin SD, Zurakowski D, Thornhill TS (2005) Uncemented glenoid component in total shoulder arthroplasty. Survivorship and outcomes. J Bone Jt Surg Am 87:1284–1292CrossRef
34.
Zurück zum Zitat Sperling JW, Cofield RH, O’Driscoll SW, Torchia ME, Rowland CM (2000) Radiographic assessment of ingrowth total shoulder arthroplasty. J Shoulder Elb Surg 9:507–513CrossRef Sperling JW, Cofield RH, O’Driscoll SW, Torchia ME, Rowland CM (2000) Radiographic assessment of ingrowth total shoulder arthroplasty. J Shoulder Elb Surg 9:507–513CrossRef
35.
Zurück zum Zitat Torrens C, Martinez-Diaz S, Ruiz A, Gines A, Caceres E (2007) Assessment of radiolucent lines in cemented shoulder hemi-arthroplasties: study of concordance and reproducibility. Int Orthop doi:10.1007/s00264-007-0452-4 Torrens C, Martinez-Diaz S, Ruiz A, Gines A, Caceres E (2007) Assessment of radiolucent lines in cemented shoulder hemi-arthroplasties: study of concordance and reproducibility. Int Orthop doi:10.​1007/​s00264-007-0452-4
36.
Zurück zum Zitat Boileau P, Watkinson D, Hatzidakis AM, Hovorka I (2006) Neer Award 2005: The Grammont reverse shoulder prosthesis: results in cuff tear arthritis, fracture sequelae, and revision arthroplasty. J Shoulder Elb Surg 15(5):527–540CrossRef Boileau P, Watkinson D, Hatzidakis AM, Hovorka I (2006) Neer Award 2005: The Grammont reverse shoulder prosthesis: results in cuff tear arthritis, fracture sequelae, and revision arthroplasty. J Shoulder Elb Surg 15(5):527–540CrossRef
37.
Zurück zum Zitat Farron A (2006) Die Schultergelenkprothese. Schweiz Med Forum 6:53–58 Farron A (2006) Die Schultergelenkprothese. Schweiz Med Forum 6:53–58
38.
Zurück zum Zitat Sanchez-Sotelo J, O’Discroll SW, Torchia ME, Cofield RH, Rowland CM (2001) Radiographic assessment of cemented humeral components in shoulder arthroplasty. J Shoulder Elb Surg 10:526–531CrossRef Sanchez-Sotelo J, O’Discroll SW, Torchia ME, Cofield RH, Rowland CM (2001) Radiographic assessment of cemented humeral components in shoulder arthroplasty. J Shoulder Elb Surg 10:526–531CrossRef
39.
Zurück zum Zitat Collins D, Tencer A, Sidles J, Matsen F 3rd (1992) Edge displacement and deformation of glenoid components in response to eccentric loading. The effect of preparation of the glenoid bone. J Bone Jt Surg Am 74:501–507 Collins D, Tencer A, Sidles J, Matsen F 3rd (1992) Edge displacement and deformation of glenoid components in response to eccentric loading. The effect of preparation of the glenoid bone. J Bone Jt Surg Am 74:501–507
40.
Zurück zum Zitat Walch G, Edwards TB, Boulahia A, Boileau P, Mole D, Adeleine P (2002) The influence of glenohumeral prosthetic mismatch on glenoid radiolucent lines: results of a multicenter study. J Bone Jt Surg Am 84-A:2186–2191 Walch G, Edwards TB, Boulahia A, Boileau P, Mole D, Adeleine P (2002) The influence of glenohumeral prosthetic mismatch on glenoid radiolucent lines: results of a multicenter study. J Bone Jt Surg Am 84-A:2186–2191
41.
Zurück zum Zitat Iannotti JP, Gabriel JP, Schneck SL, Evans BG, Misra S (1992) The normal glenohumeral relationships. An anatomical study of one hundred and forty shoulders. J Bone Jt Surg Am 74:491–500 Iannotti JP, Gabriel JP, Schneck SL, Evans BG, Misra S (1992) The normal glenohumeral relationships. An anatomical study of one hundred and forty shoulders. J Bone Jt Surg Am 74:491–500
42.
Zurück zum Zitat Warren RF, Coleman SH, Dines JS (2002) Instability after arthroplasty: the shoulder. J Arthroplasty 17:28–31PubMedCrossRef Warren RF, Coleman SH, Dines JS (2002) Instability after arthroplasty: the shoulder. J Arthroplasty 17:28–31PubMedCrossRef
43.
Zurück zum Zitat Boyd AD Jr, Aliabadi P, Thornhill TS (1991) Postoperative proximal migration in total shoulder arthroplasty. Incidence and significance. J Arthroplasty 6:31–37PubMedCrossRef Boyd AD Jr, Aliabadi P, Thornhill TS (1991) Postoperative proximal migration in total shoulder arthroplasty. Incidence and significance. J Arthroplasty 6:31–37PubMedCrossRef
44.
Zurück zum Zitat McDonough EB, Crosby LA (2005) Periprosthetic fractures of the humerus. Am J orthop 34(12):586–591PubMed McDonough EB, Crosby LA (2005) Periprosthetic fractures of the humerus. Am J orthop 34(12):586–591PubMed
45.
Zurück zum Zitat Groh G, Heckman M, Curtis R et al (1994) Treatment of fractures adjacent to humeral prosthesis. In: Annual meeting of the American Academy of Orthopaedic Surgeons. New Orleans, LA Groh G, Heckman M, Curtis R et al (1994) Treatment of fractures adjacent to humeral prosthesis. In: Annual meeting of the American Academy of Orthopaedic Surgeons. New Orleans, LA
46.
Zurück zum Zitat Campbell JT, Moore RS, Iannotti JP, Norris TR, Williams GR (1998) Periprosthetic humeral fractures: mechanisms of fracture and treatment options. J Shoulder Elb Surg 7:406–413CrossRef Campbell JT, Moore RS, Iannotti JP, Norris TR, Williams GR (1998) Periprosthetic humeral fractures: mechanisms of fracture and treatment options. J Shoulder Elb Surg 7:406–413CrossRef
47.
Zurück zum Zitat Worland RL, Kim DY, Arredondo J (1999) Periprosthetic humeral fractures: management and classification. J Shoulder Elb Surg 8:590–594CrossRef Worland RL, Kim DY, Arredondo J (1999) Periprosthetic humeral fractures: management and classification. J Shoulder Elb Surg 8:590–594CrossRef
48.
Zurück zum Zitat Brems JJ (2002) Complications of shoulder arthroplasty: infections, instability, and loosening. Instr Course Lect 51:29–30PubMed Brems JJ (2002) Complications of shoulder arthroplasty: infections, instability, and loosening. Instr Course Lect 51:29–30PubMed
49.
Zurück zum Zitat Bonutti PM, Hawkins RJ (1992) Fracture of the humeral shaft associated with total replacement arthroplasty of the shoulder. A case report. J Bone Jt Surg Am 74:617–618 Bonutti PM, Hawkins RJ (1992) Fracture of the humeral shaft associated with total replacement arthroplasty of the shoulder. A case report. J Bone Jt Surg Am 74:617–618
50.
Zurück zum Zitat Miller BS, Joseph TA, Noonan TJ, Horan MP, Hawkins RJ (2005) Rupture of the subscapularis tendon after shoulder arthroplasty: diagnosis, treatment, and outcome. J Shoulder Elb Surg 14:492–496CrossRef Miller BS, Joseph TA, Noonan TJ, Horan MP, Hawkins RJ (2005) Rupture of the subscapularis tendon after shoulder arthroplasty: diagnosis, treatment, and outcome. J Shoulder Elb Surg 14:492–496CrossRef
51.
Zurück zum Zitat Gerber C, Pennington SD, Yian EH, Pfirrmann CA, Werner CM, Zumstein MA (2006) Lesser tuberosity osteotomy for total shoulder arthroplasty. Surgical technique. J Bone Jt Surg Am 88(Suppl 1 Pt 2):170–177CrossRef Gerber C, Pennington SD, Yian EH, Pfirrmann CA, Werner CM, Zumstein MA (2006) Lesser tuberosity osteotomy for total shoulder arthroplasty. Surgical technique. J Bone Jt Surg Am 88(Suppl 1 Pt 2):170–177CrossRef
52.
Zurück zum Zitat Wolfe SW, Figgie MP, Inglis AE, Bohn WW, Ranawat CS (1990) Management of infection about total elbow prostheses. J Bone Jt Surg Am 72:198–212 Wolfe SW, Figgie MP, Inglis AE, Bohn WW, Ranawat CS (1990) Management of infection about total elbow prostheses. J Bone Jt Surg Am 72:198–212
53.
Zurück zum Zitat Yamaguchi K, Adams RA, Morrey RF (1998) Infection after total elbow arthroplasty. J Bone Jt Surg Am 80:481–491 Yamaguchi K, Adams RA, Morrey RF (1998) Infection after total elbow arthroplasty. J Bone Jt Surg Am 80:481–491
54.
Zurück zum Zitat Matsen FA 3rd, Rockwood CAJ, Wirth MA, Lippitt SB, Parsons M (2004) Glenohumeral arthritis and its management. In: Rockwood CAJ (ed) The shoulder, 3rd edn. Saunders, Philadelphia, pp 879–1008 Matsen FA 3rd, Rockwood CAJ, Wirth MA, Lippitt SB, Parsons M (2004) Glenohumeral arthritis and its management. In: Rockwood CAJ (ed) The shoulder, 3rd edn. Saunders, Philadelphia, pp 879–1008
55.
Zurück zum Zitat Rosenberg N, Neuann L, Modi A, Mersich IJ, Wallace AW (2007) Improvements in survival of the uncemented Nottingham total shoulder prosthesis: a prospective comparative study. BMC Musculoskelet Disord 8:76PubMedCrossRef Rosenberg N, Neuann L, Modi A, Mersich IJ, Wallace AW (2007) Improvements in survival of the uncemented Nottingham total shoulder prosthesis: a prospective comparative study. BMC Musculoskelet Disord 8:76PubMedCrossRef
56.
Zurück zum Zitat Sperling JW, Kozak TK, Hanssen AD, Cofield RH (2001) Infection after shoulder arthroplasty. Clin Orthop Relat Res 382:206–216PubMedCrossRef Sperling JW, Kozak TK, Hanssen AD, Cofield RH (2001) Infection after shoulder arthroplasty. Clin Orthop Relat Res 382:206–216PubMedCrossRef
57.
Zurück zum Zitat Coste JS, Reig S, Trojani C, Berg M, Walch G, Boileau P (2004) The management of infection in arthroplasty of the shoulder. J Bone Jt Surg Br 86:65–69 Coste JS, Reig S, Trojani C, Berg M, Walch G, Boileau P (2004) The management of infection in arthroplasty of the shoulder. J Bone Jt Surg Br 86:65–69
58.
Zurück zum Zitat Proubasta IR, Itarte JP, Lamas CG, Escriba IU (2005) Permanent articulated antibiotic-impregnated cement spacer in septic shoulder arthroplasty: a case report. J Orthop Trauma 19:666–668PubMedCrossRef Proubasta IR, Itarte JP, Lamas CG, Escriba IU (2005) Permanent articulated antibiotic-impregnated cement spacer in septic shoulder arthroplasty: a case report. J Orthop Trauma 19:666–668PubMedCrossRef
59.
Zurück zum Zitat Ince A, Seemann K, Frommelt L, Katzer A, Loehr JF (2005) One-stage exchange shoulder arthroplasty for periprosthetic infection. J Bone Jt Surg Br 87:814–818CrossRef Ince A, Seemann K, Frommelt L, Katzer A, Loehr JF (2005) One-stage exchange shoulder arthroplasty for periprosthetic infection. J Bone Jt Surg Br 87:814–818CrossRef
60.
Zurück zum Zitat Seitz WH Jr, Damacen H (2002) Staged exchange arthroplasty for shoulder sepsis. J Arthroplasty 17:36–40PubMedCrossRef Seitz WH Jr, Damacen H (2002) Staged exchange arthroplasty for shoulder sepsis. J Arthroplasty 17:36–40PubMedCrossRef
61.
Zurück zum Zitat Ramsey ML, Fenlin JM Jr (1996) Use of an antibiotic-impregnated bone cement block in the revision of an infected shoulder arthroplasty. J Shoulder Elb Surg 5:479–482CrossRef Ramsey ML, Fenlin JM Jr (1996) Use of an antibiotic-impregnated bone cement block in the revision of an infected shoulder arthroplasty. J Shoulder Elb Surg 5:479–482CrossRef
62.
Zurück zum Zitat Loebenberg MI, Zuckerman JD (2004) An articulating interval spacer in the treatment of an infected total shoulder arthroplasty. J Shoulder Elb Surg 13:476–478CrossRef Loebenberg MI, Zuckerman JD (2004) An articulating interval spacer in the treatment of an infected total shoulder arthroplasty. J Shoulder Elb Surg 13:476–478CrossRef
63.
Zurück zum Zitat Sperling JW, Cofield RH, Rowland CM (2000) Heterotopic ossification after total shoulder arthroplasty. J Arthroplasty 15:179–182PubMedCrossRef Sperling JW, Cofield RH, Rowland CM (2000) Heterotopic ossification after total shoulder arthroplasty. J Arthroplasty 15:179–182PubMedCrossRef
64.
Zurück zum Zitat Kjaersgaard-Andersen P, Frich LH, Sojbjerg JO, Sneppen O (1989) Heterotopic bone formation following total shoulder arthroplasty. J Arthroplasty 4:99–104PubMedCrossRef Kjaersgaard-Andersen P, Frich LH, Sojbjerg JO, Sneppen O (1989) Heterotopic bone formation following total shoulder arthroplasty. J Arthroplasty 4:99–104PubMedCrossRef
65.
Zurück zum Zitat Brenner BC, Ferlic DC, Clayton ML, Dennis DA (1989) Survivorship of unconstrained total shoulder arthroplasty. J Bone Jt Surg Am 71:1289–1296 Brenner BC, Ferlic DC, Clayton ML, Dennis DA (1989) Survivorship of unconstrained total shoulder arthroplasty. J Bone Jt Surg Am 71:1289–1296
66.
Zurück zum Zitat Clayton ML, Ferlic DC, Jeffers PD (1982) Prosthetic arthroplasties of the shoulder. Clin Orthop Relat Res 164:184–191PubMed Clayton ML, Ferlic DC, Jeffers PD (1982) Prosthetic arthroplasties of the shoulder. Clin Orthop Relat Res 164:184–191PubMed
67.
Zurück zum Zitat McElwain JP, English E (1987) The early results of porous-coated total shoulder arthroplasty. Clin Orthop Relat Res 218:217–224PubMed McElwain JP, English E (1987) The early results of porous-coated total shoulder arthroplasty. Clin Orthop Relat Res 218:217–224PubMed
68.
Zurück zum Zitat Martin SDSC, Thomas WH, Thornhill TS (1995) Total shoulder arthroplasty with an uncemented glenoid component. Paper presented at the annual meeting of the American Shoulder and Elbow Surgeons, Orlando Martin SDSC, Thomas WH, Thornhill TS (1995) Total shoulder arthroplasty with an uncemented glenoid component. Paper presented at the annual meeting of the American Shoulder and Elbow Surgeons, Orlando
69.
Zurück zum Zitat Cofield RHDP (1992) Total shoulder arthroplasty with a tissue-ingrowth glenoid component. J Shoulder Elb Surg 1:77–85CrossRef Cofield RHDP (1992) Total shoulder arthroplasty with a tissue-ingrowth glenoid component. J Shoulder Elb Surg 1:77–85CrossRef
70.
Zurück zum Zitat Driessnack RP, Ferlic DC, Wiedel JD (1990) Dissociation of the glenoid component in the Macnab/English total shoulder arthroplasty. J Arthroplasty 5:15–18PubMedCrossRef Driessnack RP, Ferlic DC, Wiedel JD (1990) Dissociation of the glenoid component in the Macnab/English total shoulder arthroplasty. J Arthroplasty 5:15–18PubMedCrossRef
Metadaten
Titel
Shoulder arthroplasty
verfasst von
Florian M. Buck
Bernhard Jost
Juerg Hodler
Publikationsdatum
01.12.2008
Verlag
Springer-Verlag
Erschienen in
European Radiology / Ausgabe 12/2008
Print ISSN: 0938-7994
Elektronische ISSN: 1432-1084
DOI
https://doi.org/10.1007/s00330-008-1093-8

Weitere Artikel der Ausgabe 12/2008

European Radiology 12/2008 Zur Ausgabe

Update Radiologie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.