Abstract

The purpose was to compare the findings of multi-detector computed tomography (MDCT) in prosthetic valve disorders using the operative findings as a gold standard. In a 3-year period, we prospectively enrolled 25 patients with 31 prosthetic heart valves. MDCT and transthoracic echocardiography (TTE) were done to evaluate pannus formation, prosthetic valve dysfunction, suture loosening (paravalvular leak) and pseudoaneurysm formation. Patients indicated for surgery received an operation within 1 week. The MDCT findings were compared with the operative findings. One patient with a Björk-Shiley valve could not be evaluated by MDCT due to a severe beam-hardening artifact; thus, the exclusion rate for MDCT was 3.2% (1/31). Prosthetic valve disorders were suspected in 12 patients by either MDCT or TTE. Six patients received an operation that included three redo aortic valve replacements, two redo mitral replacements and one Amplatzer ductal occluder occlusion of a mitral paravalvular leak. The concordance of MDCT for diagnosing and localizing prosthetic valve disorders and the surgical findings was 100%. Except for images impaired by severe beam-hardening artifacts, MDCT provides excellent delineation of prosthetic valve disorders.
Anhänge
Nur mit Berechtigung zugänglich
Literatur
1.
Zurück zum Zitat Lindblom D, Lindblom U, Qvist J, Lundström H (1990) Long-term relative survival rates after heart valve replacement. J Am Coll Cardiol 15:566–573PubMedCrossRef Lindblom D, Lindblom U, Qvist J, Lundström H (1990) Long-term relative survival rates after heart valve replacement. J Am Coll Cardiol 15:566–573PubMedCrossRef
2.
Zurück zum Zitat Groves P (2001) Surgery of valve disease: late results and late complications. Heart 86:715–721PubMedCrossRef Groves P (2001) Surgery of valve disease: late results and late complications. Heart 86:715–721PubMedCrossRef
3.
4.
Zurück zum Zitat Gupta R, Jammula P, Huang MH, Atar S, Ahmad M (2006) An unusual complication after aortic valve replacement. J Clin Ultrasound 34:361–364PubMedCrossRef Gupta R, Jammula P, Huang MH, Atar S, Ahmad M (2006) An unusual complication after aortic valve replacement. J Clin Ultrasound 34:361–364PubMedCrossRef
5.
Zurück zum Zitat Aslam AK, Aslam AF, Vasavada BC, Khan IA (2007) Prosthetic heart valves: types and echocardiographic evaluation. Int J Cardiol 122:99–110PubMedCrossRef Aslam AK, Aslam AF, Vasavada BC, Khan IA (2007) Prosthetic heart valves: types and echocardiographic evaluation. Int J Cardiol 122:99–110PubMedCrossRef
6.
Zurück zum Zitat Muratori M, Montorsi P, Teruzzi G, Celeste F, Doria E, Alamanni F, Pepi M (2006) Feasibility and diagnostic accuracy of quantitative assessment of mechanical prostheses leaflet motion by transthoracic and transesophageal echocardiography in suspected prosthetic valve dysfunction. Am J Cardiol 97:94–100PubMedCrossRef Muratori M, Montorsi P, Teruzzi G, Celeste F, Doria E, Alamanni F, Pepi M (2006) Feasibility and diagnostic accuracy of quantitative assessment of mechanical prostheses leaflet motion by transthoracic and transesophageal echocardiography in suspected prosthetic valve dysfunction. Am J Cardiol 97:94–100PubMedCrossRef
7.
Zurück zum Zitat Sakamoto Y, Hashimoto K, Okuyama H, Ishii S, Shingo T, Kagawa H (2006) Prevalence of pannus formation after aortic valve replacement: clinical aspects and surgical management. J Artif Organs 9:199–202PubMedCrossRef Sakamoto Y, Hashimoto K, Okuyama H, Ishii S, Shingo T, Kagawa H (2006) Prevalence of pannus formation after aortic valve replacement: clinical aspects and surgical management. J Artif Organs 9:199–202PubMedCrossRef
8.
Zurück zum Zitat Tsai IC, Lee T, Chen MC, Fu YC, Jan SL, Wang CC, Chang Y (2007) Visualization of neonatal coronary arteries on multidetector row CT: ECG-gated versus non-ECG-gated technique. Pediatr Radiol 37:818–825PubMedCrossRef Tsai IC, Lee T, Chen MC, Fu YC, Jan SL, Wang CC, Chang Y (2007) Visualization of neonatal coronary arteries on multidetector row CT: ECG-gated versus non-ECG-gated technique. Pediatr Radiol 37:818–825PubMedCrossRef
9.
Zurück zum Zitat Lee T, Tsai IC, Fu YC, Jan SL, Wang CC, Chang Y, Chen MC (2006) Using multidetector-row CT in neonates with complex congenital heart disease to replace diagnostic cardiac catheterization for anatomical investigation: initial experiences in technical and clinical feasibility. Pediatr Radiol 36:1273–1282PubMedCrossRef Lee T, Tsai IC, Fu YC, Jan SL, Wang CC, Chang Y, Chen MC (2006) Using multidetector-row CT in neonates with complex congenital heart disease to replace diagnostic cardiac catheterization for anatomical investigation: initial experiences in technical and clinical feasibility. Pediatr Radiol 36:1273–1282PubMedCrossRef
10.
Zurück zum Zitat Tsai IC, Chen MC, Jan SL, Wang CC, Fu YC, Lin PC, Lee T (2008) Neonatal cardiac multidetector row CT: why and how we do it. Pediatr Radiol 38:438–451PubMedCrossRef Tsai IC, Chen MC, Jan SL, Wang CC, Fu YC, Lin PC, Lee T (2008) Neonatal cardiac multidetector row CT: why and how we do it. Pediatr Radiol 38:438–451PubMedCrossRef
11.
Zurück zum Zitat Lee T, Tsai IC, Fu YC, Jan SL, Wang CC, Chang Y, Chen MC (2007) MDCT evaluation after closure of atrial septal defect with an Amplatzer septal occluder. AJR Am J Roentgenol 188:W431–W439PubMedCrossRef Lee T, Tsai IC, Fu YC, Jan SL, Wang CC, Chang Y, Chen MC (2007) MDCT evaluation after closure of atrial septal defect with an Amplatzer septal occluder. AJR Am J Roentgenol 188:W431–W439PubMedCrossRef
12.
Zurück zum Zitat Leborgne L, Renard C, Tribouilloy C (2006) Usefulness of ECG-gated multi-detector computed tomography for the diagnosis of mechanical prosthetic valve dysfunction. Eur Heart J 27:2537PubMedCrossRef Leborgne L, Renard C, Tribouilloy C (2006) Usefulness of ECG-gated multi-detector computed tomography for the diagnosis of mechanical prosthetic valve dysfunction. Eur Heart J 27:2537PubMedCrossRef
13.
Zurück zum Zitat Teshima H, Aoyagi S, Hayashida N, Shojima T, Takagi K, Arinaga K, Yoshikawa K (2005) Dysfunction of an ATS valve in the aortic position: the first reported case caused by pannus formation. J Artif Organs 8:270–273PubMedCrossRef Teshima H, Aoyagi S, Hayashida N, Shojima T, Takagi K, Arinaga K, Yoshikawa K (2005) Dysfunction of an ATS valve in the aortic position: the first reported case caused by pannus formation. J Artif Organs 8:270–273PubMedCrossRef
14.
Zurück zum Zitat Faletra FF, Alain M, Moccetti T (2007) Blockage of bileaflet mitral valve prosthesis imaged by computed tomography virtual endoscopy. Heart 93:324PubMedCrossRef Faletra FF, Alain M, Moccetti T (2007) Blockage of bileaflet mitral valve prosthesis imaged by computed tomography virtual endoscopy. Heart 93:324PubMedCrossRef
15.
Zurück zum Zitat Numata S, Okada H, Kitahara H, Kawazoe K (2007) Four-dimensional evaluation of implanted mechanical valve with 64-row multi-detector computed tomography. Eur J Cardiothorac Surg 31:934PubMedCrossRef Numata S, Okada H, Kitahara H, Kawazoe K (2007) Four-dimensional evaluation of implanted mechanical valve with 64-row multi-detector computed tomography. Eur J Cardiothorac Surg 31:934PubMedCrossRef
16.
Zurück zum Zitat Teshima H, Hayashida N, Enomoto N, Aoyagi S, Okuda K, Uchida M (2003) Detection of pannus by multidetector-row computed tomography. Ann Thorac Surg 75:1631–1633PubMedCrossRef Teshima H, Hayashida N, Enomoto N, Aoyagi S, Okuda K, Uchida M (2003) Detection of pannus by multidetector-row computed tomography. Ann Thorac Surg 75:1631–1633PubMedCrossRef
17.
Zurück zum Zitat Teshima H, Hayashida N, Fukunaga S, Tayama E, Kawara T, Aoyagi S, Uchida M (2004) Usefulness of a multidetector-row computed tomography scanner for detecting pannus formation. Ann Thorac Surg 77:523–526PubMedCrossRef Teshima H, Hayashida N, Fukunaga S, Tayama E, Kawara T, Aoyagi S, Uchida M (2004) Usefulness of a multidetector-row computed tomography scanner for detecting pannus formation. Ann Thorac Surg 77:523–526PubMedCrossRef
18.
Zurück zum Zitat Tsai IC, Lee T, Lee WL, Tsao CR, Tsai WL, Chen MC, Ting CT (2007) Use of 40-detector row computed tomography before catheter coronary angiography to select early conservative versus early invasive treatment for patients with low-risk acute coronary syndrome. J Comput Assist Tomogr 31:258–264PubMedCrossRef Tsai IC, Lee T, Lee WL, Tsao CR, Tsai WL, Chen MC, Ting CT (2007) Use of 40-detector row computed tomography before catheter coronary angiography to select early conservative versus early invasive treatment for patients with low-risk acute coronary syndrome. J Comput Assist Tomogr 31:258–264PubMedCrossRef
19.
Zurück zum Zitat Tsai IC, Lee T, Chen MC, Tsai WL, Lin PC, Liao WC (2007) Homogeneous enhancement in pediatric thoracic CT aortography using a novel and reproducible method: contrast-covering time. AJR Am J Roentgenol 188:1131–1137PubMedCrossRef Tsai IC, Lee T, Chen MC, Tsai WL, Lin PC, Liao WC (2007) Homogeneous enhancement in pediatric thoracic CT aortography using a novel and reproducible method: contrast-covering time. AJR Am J Roentgenol 188:1131–1137PubMedCrossRef
21.
Zurück zum Zitat Fu YC, Bass J, Amin Z, Radtke W, Cheatham JP, Hellenbrand WE, Balzer D, Cao QL, Hijazi ZM (2006) Transcatheter closure of perimembranous ventricular septal defects using the new Amplatzer membranous VSD occluder: results of the U.S. phase I trial. J Am Coll Cardiol 47:319–325PubMedCrossRef Fu YC, Bass J, Amin Z, Radtke W, Cheatham JP, Hellenbrand WE, Balzer D, Cao QL, Hijazi ZM (2006) Transcatheter closure of perimembranous ventricular septal defects using the new Amplatzer membranous VSD occluder: results of the U.S. phase I trial. J Am Coll Cardiol 47:319–325PubMedCrossRef
22.
Zurück zum Zitat Shapira Y, Hirsch R, Kornowski R, Hasdai D, Assali A, Vaturi M, Sievert H, Hein R, Battler A, Sagie A (2007) Percutaneous closure of perivalvular leaks with Amplatzer occluders: feasibility, safety, and short term results. J Heart Valve Dis 16:305–313PubMed Shapira Y, Hirsch R, Kornowski R, Hasdai D, Assali A, Vaturi M, Sievert H, Hein R, Battler A, Sagie A (2007) Percutaneous closure of perivalvular leaks with Amplatzer occluders: feasibility, safety, and short term results. J Heart Valve Dis 16:305–313PubMed
23.
Zurück zum Zitat McCollough C, Cody D, Edyvean S, et al for the Diagnostic Imaging Council CT Committee (2008) AAPM report no. 96 The Measurement, Reporting, and Management of Radiation Dose in CT. American Association of Physicists in Medicine. Jan 2008 McCollough C, Cody D, Edyvean S, et al for the Diagnostic Imaging Council CT Committee (2008) AAPM report no. 96 The Measurement, Reporting, and Management of Radiation Dose in CT. American Association of Physicists in Medicine. Jan 2008
24.
Zurück zum Zitat Brendzel AM, Rambod E, Jorgensen SM, Reyes DA, Chmelik MS, Ritman EL (2002) Three-dimensional imaging of fractures in outlet struts of Björk-Shiley convexo-concave heart valves by microcomputed tomography in vitro. J Heart Valve Dis 11:114–120PubMed Brendzel AM, Rambod E, Jorgensen SM, Reyes DA, Chmelik MS, Ritman EL (2002) Three-dimensional imaging of fractures in outlet struts of Björk-Shiley convexo-concave heart valves by microcomputed tomography in vitro. J Heart Valve Dis 11:114–120PubMed
Metadaten
Titel
Correctness of multi-detector-row computed tomography for diagnosing mechanical prosthetic heart valve disorders using operative findings as a gold standard
verfasst von
I-Chen Tsai
Yung-Kai Lin
Yen Chang
Yun-Ching Fu
Chung-Chi Wang
Shih-Rong Hsieh
Hao-Ji Wei
Hung-Wen Tsai
Sheng-Ling Jan
Kuo-Yang Wang
Min-Chi Chen
Clayton Chi-Chang Chen
Publikationsdatum
01.04.2009
Verlag
Springer-Verlag
Erschienen in
European Radiology / Ausgabe 4/2009
Print ISSN: 0938-7994
Elektronische ISSN: 1432-1084
DOI
https://doi.org/10.1007/s00330-008-1232-2

Weitere Artikel der Ausgabe 4/2009

European Radiology 4/2009 Zur Ausgabe

Update Radiologie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.