Skip to main content
Erschienen in: European Radiology 5/2009

01.05.2009 | Magnetic Resonance

Prospective, intraindividual comparison of MRI versus MDCT for endoleak detection after endovascular repair of abdominal aortic aneurysms

verfasst von: Mario Alerci, Michel Oberson, Antonella Fogliata, Augusto Gallino, Peter Vock, Rolf Wyttenbach

Erschienen in: European Radiology | Ausgabe 5/2009

Einloggen, um Zugang zu erhalten

Abstract

This study compares MRI and MDCT for endoleak detection after endovascular repair of abdominal aortic aneurysms (EVAR). Forty-three patients with previous EVAR underwent both MRI (2D T1-FFE unenhanced and contrast-enhanced; 3D triphasic contrast-enhanced) and 16-slice MDCT (unenhanced and biphasic contrast-enhanced) within 1 week of each other for endoleak detection. MRI was performed by using a high-relaxivity contrast medium (gadobenate dimeglumine, MultiHance®). Two blinded, independent observers evaluated MRI and MDCT separately. Consensus reading of MRI and MDCT studies was defined as reference standard. Sensitivity, specificity, and accuracy were calculated and Cohen’s k statistics were used to estimate agreement between readers. Twenty endoleaks were detected in 18 patients at consensus reading (12 type II and 8 indeterminate endoleaks). Sensitivity, specificity, and accuracy for endoleak detection were 100%, 92%, and 96%, respectively, for reader 1 (95%, 81%, 87% for reader 2) for MRI and 55%, 100%, and 80% for reader 1 (60%, 100%, 82% for reader 2) for MDCT. Interobserver agreement was excellent for MDCT (k = 0.96) and good for MRI (k = 0.81). MRI with the use of a high-relaxivity contrast agent is significantly superior in the detection of endoleaks after EVAR compared with MDCT. MRI may therefore become the preferred technique for patient follow-up after EVAR.
Literatur
1.
Zurück zum Zitat Parodi JC, Palmaz JC, Barone HD (1991) Transfemoral intraluminal graft implantation for abdominal aortic aneurysm. Ann Vasc Surg 5:491–499PubMedCrossRef Parodi JC, Palmaz JC, Barone HD (1991) Transfemoral intraluminal graft implantation for abdominal aortic aneurysm. Ann Vasc Surg 5:491–499PubMedCrossRef
2.
Zurück zum Zitat Zarins CK, Wolf YG, Lee WA et al (2000) Will endovascular repair replace open surgery for abdominal aortic aneurysm repair? Ann Surg 232:501–507PubMedCrossRef Zarins CK, Wolf YG, Lee WA et al (2000) Will endovascular repair replace open surgery for abdominal aortic aneurysm repair? Ann Surg 232:501–507PubMedCrossRef
3.
Zurück zum Zitat Stavropoulos SW, Charagundla SR (2007) Imaging techniques for detection and management of endoleaks after endovascular aortic aneurysm repair. Radiology 243:641–655PubMedCrossRef Stavropoulos SW, Charagundla SR (2007) Imaging techniques for detection and management of endoleaks after endovascular aortic aneurysm repair. Radiology 243:641–655PubMedCrossRef
4.
Zurück zum Zitat Eliason JL, Upchurch GR Jr (2008) Endovascular abdominal aortic aneurysm repair. Circulation 117:1738–1744PubMedCrossRef Eliason JL, Upchurch GR Jr (2008) Endovascular abdominal aortic aneurysm repair. Circulation 117:1738–1744PubMedCrossRef
5.
Zurück zum Zitat Görich J, Rilinger N, Sokiranski R et al (1999) Leakages after endovascular repair of aortic aneurysm: classification based on findings at CT, angiography and radiography. Radiology 213:767–772PubMed Görich J, Rilinger N, Sokiranski R et al (1999) Leakages after endovascular repair of aortic aneurysm: classification based on findings at CT, angiography and radiography. Radiology 213:767–772PubMed
6.
Zurück zum Zitat Rozenblit AM, Patlas M, Rosenbaum AT et al (2003) Detection of endoleaks after endovascular repair of abdominal aortic aneurysm: value of unenhanced and delayed helical CT acquisition. Radiology 227:426–433PubMedCrossRef Rozenblit AM, Patlas M, Rosenbaum AT et al (2003) Detection of endoleaks after endovascular repair of abdominal aortic aneurysm: value of unenhanced and delayed helical CT acquisition. Radiology 227:426–433PubMedCrossRef
7.
Zurück zum Zitat Stavropoulos SW, Clark TWI, Carpenter JP et al (2005) Use of CT angiography to classify endoleaks after endovascular repair of abdominal aortic aneurysm. J Vasc Interv Radiol 16:663–667PubMed Stavropoulos SW, Clark TWI, Carpenter JP et al (2005) Use of CT angiography to classify endoleaks after endovascular repair of abdominal aortic aneurysm. J Vasc Interv Radiol 16:663–667PubMed
8.
Zurück zum Zitat Cherniak V, Rozenblit AM, Patlas M et al (2006) Type II endoleak after endoaortic graft implantation: diagnosis with helical CT angiography. Radiology 240:885–893CrossRef Cherniak V, Rozenblit AM, Patlas M et al (2006) Type II endoleak after endoaortic graft implantation: diagnosis with helical CT angiography. Radiology 240:885–893CrossRef
9.
Zurück zum Zitat Wicky S, Fan CM, Geller SC et al (2003) MR angiography of endoleak with inconclusive concomitant CT angiography. Am J Roentgenol 181:736–738 Wicky S, Fan CM, Geller SC et al (2003) MR angiography of endoleak with inconclusive concomitant CT angiography. Am J Roentgenol 181:736–738
10.
Zurück zum Zitat Pitton MB, Schweitzer H, Herber S et al (2005) MRI versus helical CT for endoleaks detection after endovascular aneurysm repair. Am J Roentgenol 185:1275–1281CrossRef Pitton MB, Schweitzer H, Herber S et al (2005) MRI versus helical CT for endoleaks detection after endovascular aneurysm repair. Am J Roentgenol 185:1275–1281CrossRef
11.
Zurück zum Zitat Van der Laan MJ, Bartels LW, Viergever MA et al (2006) Computed tomography versus magnetic resonance imaging of endoleaks after EVAR. Eur J Vasc Endovasc Surg 32:361–365PubMedCrossRef Van der Laan MJ, Bartels LW, Viergever MA et al (2006) Computed tomography versus magnetic resonance imaging of endoleaks after EVAR. Eur J Vasc Endovasc Surg 32:361–365PubMedCrossRef
12.
Zurück zum Zitat Haulon S, Lions C, Mc Fadden EP et al (2001) Prospective evaluation of magnetic resonance imaging after endovascular treatment of infrarenal aortic aneurysm. Eur J Vasc Endovasc Surg 22:62–69PubMedCrossRef Haulon S, Lions C, Mc Fadden EP et al (2001) Prospective evaluation of magnetic resonance imaging after endovascular treatment of infrarenal aortic aneurysm. Eur J Vasc Endovasc Surg 22:62–69PubMedCrossRef
13.
Zurück zum Zitat Cavagna FM, Maggioni F, Castelli PM et al (1997) Gadolinium chelates with weak binding to serum proteins; a new class of high-efficiency, general purpose contrast agents for magnetic resonance imaging. Invest Radiol 32(12):780–796PubMedCrossRef Cavagna FM, Maggioni F, Castelli PM et al (1997) Gadolinium chelates with weak binding to serum proteins; a new class of high-efficiency, general purpose contrast agents for magnetic resonance imaging. Invest Radiol 32(12):780–796PubMedCrossRef
14.
Zurück zum Zitat Bonvini RF, Alerci M, Antonucci F et al (2003) Preoperative embolization of collateral side branches: a valid means to reduce type II endoleak after endovascular AAA repair. J Endovasc Ther 10:227–232PubMedCrossRef Bonvini RF, Alerci M, Antonucci F et al (2003) Preoperative embolization of collateral side branches: a valid means to reduce type II endoleak after endovascular AAA repair. J Endovasc Ther 10:227–232PubMedCrossRef
15.
Zurück zum Zitat Willinek WA, Gieseke J, Conrad R et al (2002) Randomly segmented central k-space ordering in high-spatial-resolution contrast-enhanced MR angiography of the supraaortic arteries: initial experience. Radiology 225(2):583–588PubMedCrossRef Willinek WA, Gieseke J, Conrad R et al (2002) Randomly segmented central k-space ordering in high-spatial-resolution contrast-enhanced MR angiography of the supraaortic arteries: initial experience. Radiology 225(2):583–588PubMedCrossRef
16.
Zurück zum Zitat Pitton MB, Schmenger PR, Neufang A et al (2002) Endovascular aneurysm repair: magnetic resonance monitoring of histoloigical organization process in the excluded aneurysm. Circulation 105:1995–1999PubMedCrossRef Pitton MB, Schmenger PR, Neufang A et al (2002) Endovascular aneurysm repair: magnetic resonance monitoring of histoloigical organization process in the excluded aneurysm. Circulation 105:1995–1999PubMedCrossRef
17.
Zurück zum Zitat Zarins CK, White RA, Fogaty TJ (2000) Aneurysm rupture after endovascular repair using the AneuRx stent graft. J Vasc Surg 31:960–970PubMedCrossRef Zarins CK, White RA, Fogaty TJ (2000) Aneurysm rupture after endovascular repair using the AneuRx stent graft. J Vasc Surg 31:960–970PubMedCrossRef
18.
Zurück zum Zitat Politz JK, Newman VS, Stewart MT (2000) Late abdominal aortic aneurysm rupture after AneuRX repair: a report of three cases. J Vasc Surg 31:599–606PubMedCrossRef Politz JK, Newman VS, Stewart MT (2000) Late abdominal aortic aneurysm rupture after AneuRX repair: a report of three cases. J Vasc Surg 31:599–606PubMedCrossRef
19.
Zurück zum Zitat White RA, Donayre C, Walot I et al (2000) Abdominal aortic aneurysm rupture following endoluminal graft deployment: report of a predictable event. J Endovasc Ther 7:257–262PubMedCrossRef White RA, Donayre C, Walot I et al (2000) Abdominal aortic aneurysm rupture following endoluminal graft deployment: report of a predictable event. J Endovasc Ther 7:257–262PubMedCrossRef
20.
Zurück zum Zitat Hinchliffe RJ, Singh-Ranger R, Davidson IR et al (2001) Rupture of an aortic aneurysm secondary to type II endoleak. Eur J Vasc Endovas Surg 22:563–565CrossRef Hinchliffe RJ, Singh-Ranger R, Davidson IR et al (2001) Rupture of an aortic aneurysm secondary to type II endoleak. Eur J Vasc Endovas Surg 22:563–565CrossRef
21.
Zurück zum Zitat Cejna M, Loewe C, Schoder M et al (2002) MR angiography vs CT angiography in the follow-up of nitinol stent grafts in endoluminal treated aortic aneurysm. Eur Radiol 12:2443–2450PubMed Cejna M, Loewe C, Schoder M et al (2002) MR angiography vs CT angiography in the follow-up of nitinol stent grafts in endoluminal treated aortic aneurysm. Eur Radiol 12:2443–2450PubMed
22.
Zurück zum Zitat Sato DT, Goff CD, Gregory RT et al (1998) Endoleak after aortic stent repair: diagnosis by color duplex ultrasound scan versus computed tomography scan. J Vasc Surg 28:657–663PubMedCrossRef Sato DT, Goff CD, Gregory RT et al (1998) Endoleak after aortic stent repair: diagnosis by color duplex ultrasound scan versus computed tomography scan. J Vasc Surg 28:657–663PubMedCrossRef
23.
Zurück zum Zitat Napoli V, Bargellini I, Sardella SG et al (2004) Abdominal aortic aneurysm: contrast enhanced US for endoleak after endoluminal repair. Radiology 233:217–225PubMedCrossRef Napoli V, Bargellini I, Sardella SG et al (2004) Abdominal aortic aneurysm: contrast enhanced US for endoleak after endoluminal repair. Radiology 233:217–225PubMedCrossRef
24.
Zurück zum Zitat Pitton MB (2005) Diagnosis and management of endoleaks after endovascular aneurysm repair: role of MRI. Abdom Imaging 31:339–346CrossRef Pitton MB (2005) Diagnosis and management of endoleaks after endovascular aneurysm repair: role of MRI. Abdom Imaging 31:339–346CrossRef
25.
Zurück zum Zitat Engellau L, Larsson EM, Albrachtsson U et al (1998) Magnetic resonance imaging and MR angiography of endoluminal treated abdominal aortic aneurysm. Eur J Vasc Endovasc Surg 15:212–219PubMedCrossRef Engellau L, Larsson EM, Albrachtsson U et al (1998) Magnetic resonance imaging and MR angiography of endoluminal treated abdominal aortic aneurysm. Eur J Vasc Endovasc Surg 15:212–219PubMedCrossRef
26.
Zurück zum Zitat Insko EK, Kulzer LM, Fairman RM et al (2003) MR imaging for detection of endoleaks in recipients of abdominal aortic stent-grafts with low magnetic susceptibility. Acad Radiol 10:509–513PubMedCrossRef Insko EK, Kulzer LM, Fairman RM et al (2003) MR imaging for detection of endoleaks in recipients of abdominal aortic stent-grafts with low magnetic susceptibility. Acad Radiol 10:509–513PubMedCrossRef
27.
Zurück zum Zitat Ayuso JR, de Caralt TM, Pages M et al (2004) MRA is useful as follow-up technique after endovascular repair of aortic aneurysm with nitinol endoprosthesis. J Magn Reson Imaging 20:803–810PubMedCrossRef Ayuso JR, de Caralt TM, Pages M et al (2004) MRA is useful as follow-up technique after endovascular repair of aortic aneurysm with nitinol endoprosthesis. J Magn Reson Imaging 20:803–810PubMedCrossRef
28.
Zurück zum Zitat Brenner DJ, Elliston CD (2004) Estimated radiation risks potentially associated with full-body CT screening. Radiology 232:735–738PubMedCrossRef Brenner DJ, Elliston CD (2004) Estimated radiation risks potentially associated with full-body CT screening. Radiology 232:735–738PubMedCrossRef
29.
Zurück zum Zitat Iezzi R, Cotroneo AR, Filippone A et al (2006) Multidetector CT in abdominal aortic aneurysm treated with endovascular repair: are unenhanced and delayed phase enhanced images effective for endoleak detection. Radiology 241(3):915–921PubMedCrossRef Iezzi R, Cotroneo AR, Filippone A et al (2006) Multidetector CT in abdominal aortic aneurysm treated with endovascular repair: are unenhanced and delayed phase enhanced images effective for endoleak detection. Radiology 241(3):915–921PubMedCrossRef
30.
Zurück zum Zitat Macari M, Chandarana H, Schmidt B et al (2006) Abdominal aortic aneurysm: can the arterial phase at CT evaluation after endovascular repair be eliminated to reduce radiation dose. Radiology 241(3):908–914PubMedCrossRef Macari M, Chandarana H, Schmidt B et al (2006) Abdominal aortic aneurysm: can the arterial phase at CT evaluation after endovascular repair be eliminated to reduce radiation dose. Radiology 241(3):908–914PubMedCrossRef
31.
Zurück zum Zitat De Haen C, Cabrini M, Akhnana L et al (1999) Gd-BOPTA 0.5M solution for injection (MultiHance®): pharmaceutical formulation and physicochemical properties of a new magnetic resonance imaging contrast medium. J Comput Assist Tomogr 23(Suppl 1):S161–S168PubMed De Haen C, Cabrini M, Akhnana L et al (1999) Gd-BOPTA 0.5M solution for injection (MultiHance®): pharmaceutical formulation and physicochemical properties of a new magnetic resonance imaging contrast medium. J Comput Assist Tomogr 23(Suppl 1):S161–S168PubMed
32.
Zurück zum Zitat Wyttenbach R, Gianella S, Alerci M et al (2003) Prospective blinded evaluation of Gd-DOTA- versus Gd-BOPTA-enhanced peripheral MR angiography, as compared with digital subtraction angiography. Radiology 227:261–269PubMedCrossRef Wyttenbach R, Gianella S, Alerci M et al (2003) Prospective blinded evaluation of Gd-DOTA- versus Gd-BOPTA-enhanced peripheral MR angiography, as compared with digital subtraction angiography. Radiology 227:261–269PubMedCrossRef
33.
Zurück zum Zitat Kreitner KF, Kunz RP, Herber S et al (2008) MR angiography of the pedal arteries with gadobenate dimeglumine, a contrast agent with increased relaxivity, and comparison with selective intraarterial DSA. J Magn Reson Imaging 27(1):78–85PubMedCrossRef Kreitner KF, Kunz RP, Herber S et al (2008) MR angiography of the pedal arteries with gadobenate dimeglumine, a contrast agent with increased relaxivity, and comparison with selective intraarterial DSA. J Magn Reson Imaging 27(1):78–85PubMedCrossRef
Metadaten
Titel
Prospective, intraindividual comparison of MRI versus MDCT for endoleak detection after endovascular repair of abdominal aortic aneurysms
verfasst von
Mario Alerci
Michel Oberson
Antonella Fogliata
Augusto Gallino
Peter Vock
Rolf Wyttenbach
Publikationsdatum
01.05.2009
Verlag
Springer-Verlag
Erschienen in
European Radiology / Ausgabe 5/2009
Print ISSN: 0938-7994
Elektronische ISSN: 1432-1084
DOI
https://doi.org/10.1007/s00330-008-1253-x

Weitere Artikel der Ausgabe 5/2009

European Radiology 5/2009 Zur Ausgabe

Update Radiologie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.